Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />0.2512=4x6 <br />=5x6 =4x6 <br />=4x6 =2x4 <br />=5x8 <br />=5x6 <br />=5x8 <br />=4x6 <br />=4x6 =M18AHS 3x10 =4x5 <br />=4x5 <br />=4x629 <br />23 <br />26 22 27 21 28 20 19 30 18 17 31 16 32 15 33 <br />14 <br />1343124211411094083973865374363352341 <br />25 <br />24 <br />0-8-14 <br />18 -5-9 <br />1-2-15 <br />35-8-7 <br />0-5-10 <br />49-1-0 <br />2-6-2 <br />48-7-6 <br />0-5-10 <br />0-5-10 <br />3-1-15 <br />17 -8-12 <br />3-6-9 <br />14-6-13 <br />3-9-4 <br />34-5-9 <br />4-5-9 <br />4-11-3 <br />5-0-14 <br />23 -6-8 <br />5-1-11 <br />40-10-2 <br />5-3-2 <br />46-1-4 <br />6-1-1 <br />11-0-3 <br />7-1-13 <br />30-8-4 <br />0-0-15 <br />14-7-12 <br />5-0-15 <br />38 -2-15 <br />5-2-6 <br />43-5-5 <br />5-4-4 <br />20-0-0 <br />5-7-11 <br />49-1-0 <br />6-1-1 <br />33 -1-15 <br />6-11-5 <br />14-6-13 <br />7-0-15 <br />27-0-15 <br />7-7-7 <br />7-7-7 <br />4-2-0 <br />3-6-0 <br />1-10 <br />-2 <br />1-10 <br />-2 1-0-1 <br />2-10 <br />-2 <br />0-7-14 <br />3-6-0 <br />0-8-0 <br />4-2-0 <br />Scale = 1:83.7 <br />Plate Offsets (X, Y):[1:0-2-15,Edge], [20:0-4-0,0-3-0] <br />Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP <br />TCLL (roof)20.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL)-0.36 16-17 >999 360 MT20 220/195 <br />TCDL 14.0 Lumber DOL 1.25 BC 0.85 Vert(CT)-0.75 16-17 >552 240 M18AHS 169/162 <br />BCLL 0.0 *Rep Stress Incr YES WB 0.80 Horz(CT)0.07 14 n/a n/a <br />BCDL 7.0 Code IBC2021/TPI2014 Matrix-MSH Wind(LL)0.26 16-17 >999 240 Weight: 228 lb FT = 20% <br />LUMBER <br />TOP CHORD 2x4 DF No.2 G *Except* 1-6:2x4 DF 1800F <br />1.6E G or 2x4 DF No.1&Btr G <br />BOT CHORD 2x4 DF No.2 G <br />WEBS 2x4 DF No.2 G or 2x4 DF Std G or 2x4 DF <br />Stud G *Except* 24-23,25-14:2x6 DF No.2 G <br />BRACING <br />TOP CHORD Structural wood sheathing directly applied or <br />2-2-0 oc purlins, except end verticals. <br />BOT CHORD Rigid ceiling directly applied or 3-10-10 oc <br />bracing. <br />REACTIONS (size)14=0-5-8, 21=0-5-8, 23=0-5-8 <br />Max Horiz 23=-162 (LC 8) <br />Max Uplift 14=-47 (LC 9), 21=-129 (LC 13), <br />23=-188 (LC 54) <br />Max Grav 14=1117 (LC 1), 21=2972 (LC 1), <br />23=327 (LC 58) <br />FORCES (lb) - Maximum Compression/Maximum <br />Tension <br />TOP CHORD 1-2=-110/89, 2-3=-226/1275, 3-4=-597/4306, <br />4-5=-599/4305, 5-7=-181/909, <br />7-8=-2374/348, 8-10=-3946/582, <br />10-11=-4042/602, 11-12=-2860/452, <br />12-13=-146/112, 1-23=-431/38, 1-24=0/0, <br />13-14=-412/55, 13-25=0/0 <br />BOT CHORD 22-23=-526/231, 21-22=-2452/415, <br />19-21=-2195/1159, 17-19=-519/3606, <br />16-17=-572/4205, 15-16=-505/3749, <br />14-15=-263/1762 <br />WEBS 4-21=-465/51, 7-20=-2300/374, <br />7-19=-127/1493, 8-19=-1401/261, <br />8-17=-10/666, 10-17=-510/105, <br />10-16=-369/242, 11-15=-1069/207, <br />12-15=-126/1276, 12-14=-1992/304, <br />5-21=-2564/370, 5-20=-195/1790, <br />11-16=-49/564, 2-22=-1051/234, <br />2-23=-190/613, 3-22=-159/1433, <br />3-21=-2213/360 <br />NOTES <br />1)Unbalanced roof live loads have been considered for <br />this design. <br />2)Wind: ASCE 7-16; Vult=96mph (3-second gust) <br />Vasd=76mph; TCDL=8.4psf; BCDL=4.2psf; h=25ft; Cat. <br />II; Exp C; Enclosed; MWFRS (envelope) exterior zone <br />and C-C Corner (3) 0-2-13 to 5-2-13, Exterior (2) 5-2-13 <br />to 43-10-3, Corner (3) 43-10-3 to 48-10-3 zone; <br />cantilever left and right exposed ; end vertical left and <br />right exposed;C-C for members and forces & MWFRS <br />for reactions shown; Lumber DOL=1.60 plate grip <br />DOL=1.60 <br />3)Provide adequate drainage to prevent water ponding. <br />4)All plates are MT20 plates unless otherwise indicated. <br />5)All plates are 3x6 MT20 unless otherwise indicated. <br />6)The Fabrication Tolerance at joint 18 = 16% <br />7)This truss has been designed for a 10.0 psf bottom <br />chord live load nonconcurrent with any other live loads. <br />8)* This truss has been designed for a live load of 20.0psf <br />on the bottom chord in all areas where a rectangle <br />3-06-00 tall by 2-00-00 wide will fit between the bottom <br />chord and any other members. <br />9)A plate rating reduction of 20% has been applied for the <br />green lumber members. <br />10)All bearings are assumed to be DF No.2 crushing <br />capacity of 625 psi. <br />11)Provide mechanical connection (by others) of truss to <br />bearing plate capable of withstanding 129 lb uplift at <br />joint 21, 47 lb uplift at joint 14 and 188 lb uplift at joint <br />23. <br />12)This truss has been designed for a moving concentrated <br />load of 300.0lb live and 80.0lb dead located at all mid <br />panels and at all panel points along the Top Chord and <br />Bottom Chord, nonconcurrent with any other live loads. <br />13)This truss is designed for a creep factor of 2.01, which is <br />used to calculate the Vert(CT) deflection per ANSI/TPI 1. <br />The building designer shall verify that this parameter fits <br />with the intended use of this component. <br />LOAD CASE(S) Standard <br />Job Truss Truss Type Qty Ply M39558- TOMS JR SANTA ANA <br />R80031744AA03Roof Special 4 1M39885- TOMS JR Job Reference (optional) <br />Builders FirstSource (Perris, CA), Perris, CA - 92570,Run: 8.63 S Nov 1 2023 Print: 8.630 S Nov 1 2023 MiTek Industries, Inc. Wed Dec 27 09:55:30 Page: 1 <br />ID:AlOMv3SPX61Th1gVO?vuYZyETtF-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f <br />December 27,2023 <br />1430 E Edinger Ave <br />3/27/2025