Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />0.2512 <br />=3x6 <br />=5x8 <br />=7x10 <br />=2x4 =4x12 <br />=2x6 =4x12 <br />=2x4 =3x10 <br />=M18AHS 8x12 <br />=5x6 <br />=2x4 <br />=4x8 =2x6 <br />=3x10 <br />=4x5 <br />=3x6 <br />=5x8 =3x10 <br />=6x16 <br />37 <br />20 <br />34 19 35 18 36 17 16 38 15 39 14 40 13 41 12 42 11 <br />2223 <br />1033932831763029528274263252241 <br />21 <br />0-5-10 <br />34-8-0 <br />3-1-4 <br />27 -7-8 <br />4-0-7 <br />8-1-15 <br />4-0-8 <br />12-2-7 <br />4-1-2 <br />20-4-10 <br />4-1-2 <br />16-3-9 <br />4-1-10 <br />24-6-4 <br />4-1-8 <br />4-1-8 <br />6-6-14 <br />34-2-6 <br />0-5-10 <br />34-8-0 <br />2-11-11 <br />30 -7-3 <br />3-1-4 <br />27 -7-8 <br />3-7-3 <br />34-2-6 <br />4-0-7 <br />8-1-15 <br />4-0-8 <br />12-2-7 <br />4-1-2 <br />20-4-10 <br />4-1-2 <br />16-3-9 <br />4-1-10 <br />24-6-4 <br />4-1-8 <br />4-1-8 <br />5-6-0 <br />2-6-11 <br />4-8-12 <br />0-9-4 <br />1-10 <br />-2 <br />1-10 <br />-2 <br />3-7-14 <br />5-6-0 <br />Scale = 1:64.7 <br />Plate Offsets (X, Y):[1:0-3-8,0-2-8], [10:0-8-0,0-3-12], [16:0-6-0,0-6-0], [19:0-3-8,0-3-12] <br />Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP <br />TCLL (roof)20.0 Plate Grip DOL 1.25 TC 0.43 Vert(LL)-0.46 15-16 >900 360 MT20 220/195 <br />TCDL 14.0 Lumber DOL 1.25 BC 0.96 Vert(CT)-0.94 15-16 >437 240 M18AHS 169/162 <br />BCLL 0.0 *Rep Stress Incr NO WB 0.81 Horz(CT)0.06 23 n/a n/a <br />BCDL 7.0 Code IBC2021/TPI2014 Matrix-MSH Wind(LL)0.33 15-16 >999 240 Weight: 244 lb FT = 20% <br />LUMBER <br />TOP CHORD 2x6 DF No.2 G <br />BOT CHORD 2x8 DF No.2 G *Except* 16-11:2x8 DF SS G <br />WEBS 2x4 DF No.2 G or 2x4 DF Std G or 2x4 DF <br />Stud G *Except* 22-21:2x6 DF No.2 G, <br />19-1,12-10:2x4 DF No.2 G <br />OTHERS 2x6 DF No.2 G <br />BRACING <br />TOP CHORD Structural wood sheathing directly applied or <br />2-8-8 oc purlins, except end verticals. <br />BOT CHORD Rigid ceiling directly applied or 8-6-10 oc <br />bracing. <br />REACTIONS (size)20=0-5-8, 23=0-5-8 <br />Max Horiz 20=-184 (LC 10) <br />Max Uplift 20=-64 (LC 13), 23=-83 (LC 9) <br />Max Grav 20=1406 (LC 1), 23=1367 (LC 1) <br />FORCES (lb) - Maximum Compression/Maximum <br />Tension <br />TOP CHORD 1-20=-1330/240, 1-2=-2524/413, <br />2-3=-2524/410, 3-4=-6046/1026, <br />4-5=-6047/1023, 5-7=-6971/1247, <br />7-8=-6972/1244, 8-9=-5130/1067, <br />9-10=-3119/740, 11-22=-27/495, <br />10-22=-27/495, 10-21=0/0 <br />BOT CHORD 19-20=-214/186, 18-19=-848/4630, <br />17-18=-848/4630, 15-17=-1123/7040, <br />14-15=-1058/6442, 13-14=-1058/6442, <br />12-13=-903/5127, 11-12=-340/850 <br />WEBS 2-19=-465/91, 1-19=-464/2760, <br />3-19=-2317/411, 3-18=0/414, <br />3-17=-269/1552, 4-17=-445/85, <br />5-17=-1144/223, 5-16=0/443, 5-15=-461/380, <br />7-15=-439/87, 8-15=-166/735, 8-14=0/436, <br />8-13=-1461/270, 9-13=-68/617, <br />9-12=-2234/416, 10-12=-471/2427, <br />10-23=-1598/273 <br />NOTES <br />1)Wind: ASCE 7-16; Vult=96mph (3-second gust) <br />Vasd=76mph; TCDL=8.4psf; BCDL=4.2psf; h=25ft; Cat. <br />II; Exp C; Enclosed; MWFRS (envelope) exterior zone <br />and C-C Corner (3) 0-1-13 to 15-1-13, Exterior (2) <br />15-1-13 to 18-11-9, Corner (3) 18-11-9 to 33-11-9 zone; <br />cantilever left and right exposed ; end vertical left and <br />right exposed;C-C for members and forces & MWFRS <br />for reactions shown; Lumber DOL=1.60 plate grip <br />DOL=1.60 <br />2)Provide adequate drainage to prevent water ponding. <br />3)All plates are MT20 plates unless otherwise indicated. <br />4)This truss has been designed for a 10.0 psf bottom <br />chord live load nonconcurrent with any other live loads. <br />5)* This truss has been designed for a live load of 20.0psf <br />on the bottom chord in all areas where a rectangle <br />3-06-00 tall by 2-00-00 wide will fit between the bottom <br />chord and any other members. <br />6)A plate rating reduction of 20% has been applied for the <br />green lumber members. <br />7)Bearings are assumed to be: Joint 20 DF No.2 crushing <br />capacity of 625 psi, Joint 23 DF No.2 crushing capacity <br />of 625 psi. <br />8)Bearing at joint(s) 23 considers parallel to grain value <br />using ANSI/TPI 1 angle to grain formula. Building <br />designer should verify capacity of bearing surface. <br />9)Provide mechanical connection (by others) of truss to <br />bearing plate capable of withstanding 64 lb uplift at joint <br />20 and 83 lb uplift at joint 23. <br />10)This truss has been designed for a moving concentrated <br />load of 300.0lb live and 80.0lb dead located at all mid <br />panels and at all panel points along the Top Chord and <br />Bottom Chord, nonconcurrent with any other live loads. <br />11)Graphical purlin representation does not depict the size <br />or the orientation of the purlin along the top and/or <br />bottom chord. <br />12)This truss is designed for a creep factor of 2.01, which is <br />used to calculate the Vert(CT) deflection per ANSI/TPI 1. <br />The building designer shall verify that this parameter fits <br />with the intended use of this component. <br />LOAD CASE(S) Standard <br />Job Truss Truss Type Qty Ply M39558- TOMS JR SANTA ANA <br />R80031745AA04Roof Special 1 1M39885- TOMS JR Job Reference (optional) <br />Builders FirstSource (Perris, CA), Perris, CA - 92570,Run: 8.63 S Nov 1 2023 Print: 8.630 S Nov 1 2023 MiTek Industries, Inc. Wed Dec 27 09:55:31 Page: 1 <br />ID:khQzV5pn_07oTNMVNFVsM0yEC6c-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f <br />December 27,2023 <br />1430 E Edinger Ave <br />3/27/2025