My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1925 W Deerfield Rd - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Deerefield Rd
>
1925 W Deerefield Rd
>
1925 W Deerfield Rd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:50:34 AM
Creation date
2/24/2026 10:50:24 AM
Metadata
Fields
Template:
Plan
Permit Number
101126280
Full Address
1925 W Deerefield Rd
Street Number
1925
Street Direction
W
Street Name
Deerefield
Street Suffix
Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FACILITY <br />GROUND <br />120/240 VAC <br />SINGLE PHASE <br />SERVICE <br />EXISTING 225A <br />MAIN <br />BREAKER <br />-END FED <br />EXISTING 225A <br />MAIN PANEL <br />225A BUS <br />(E) FACILITY <br />LOADS <br />M <br /> 125A <br />NEW 200A <br />BACKUP GATEWAY 3 <br />(1841000-X1-Y) <br />(N) INTERNAL PANELBOARD <br />WITH(1) 60A PV+ESS BREAKER <br />4 <br />A <br />A <br />NEW 225 A BACKUP <br />LOADS PANEL WITH <br />125 A MAIN BREAKER <br />RELOCATED (E) LOADS <br />4 <br />60A <br />(N) IMO PE69-3020, <br />DISCONNECT <br />SWITCH, 3P, 16A <br />INVERTER: TESLA <br />POWERWALL 3 1707000-XX-Y, <br />ENERGY STORAGE: <br />TESLA:POWERWALL 3 <br />1707000-XX-Y 11500 WATT INVERTER <br />LOAD RATED DC DISCONNECT <br />WITH AFCI RAPID SHUTDOWN COMPLIANT, <br />POWER CONTROL SYSTEM <br />3 <br />J-BOX <br />12 <br />222012-776623 <br />CHARACTERISTICS INCLUDED IN SPEC SHEETS <br />INTERCONNECTION CALCULATIONS <br />(N)TESLA REMOTE METER <br />SITE CURRENT <br />TRANSFORMER <br />13 SILFAB <br />SIL-440QD <br />STRING 1 WITH 13 MODULES <br />WITH 5 MCI COUNT , MODULE <br />LEVEL RAPID SHUTDOWN <br />DEVICES <br />(N) LOCKABLE <br />BLADE TYPE <br />AC DISCONNECT <br />SQUARE D <br />DU222RB <br />3R, 60A, 2P <br />120/240VAC <br />3 <br />5 <br />CONDUIT SCHEDULE <br />TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT <br />1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE)Open Air <br />2 Inverter Input (2) 10 AWG <br />THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT <br />3 Inverter Output (2) 6 AWG <br />THHN/THWN-2 <br />(1) 6 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT <br />4 Backup Panel Feeder (2) 1 AWG <br />THHN/THWN-2 <br />(1) 1 AWG <br />THHN/THWN-2 6 AWG THHN/THWN-2 1 1/4 EMT <br />5 Backup loads <br />(22) 10 AWG <br />THHN/THWN-2 <br />(22) 10 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 <br />2 EMT(2) 10 AWG <br />THHN/THWN-2 <br />(1) 10 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 <br />(4) 8 AWG <br />THHN/THWN-2 <br />(2) 8 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 <br />PAGE <br />REV: A 12/22/2025 <br />TED YAMADA <br />1925 W DEERFIELD RD, SANTA <br />ANA, CA, 92704 <br />PROJECT NUMBER: <br /> 109R-925YAMA PR-3004737100 <br />SHEET <br />DESIGNER: <br />MEGHA S <br />CUSTOMER RESIDENCE: <br />TEL. (714) 550-6636 <br />APN: 412-531-54 <br />(415) 580-6920 ex3 <br />PV-4.0 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />ELECTRICAL <br />MODULE CHARACTERISTICS <br />SILFAB: SIL-440QD 440 W <br />OPEN CIRCUIT VOLTAGE 38.97 V <br />MAX POWER VOLTAGE 33.41 V <br />SHORT CIRCUIT CURRENT 14.29 A <br />INSTALLER MUST CHECK THE CONDITION, <br />INSTALLABILITY AND CODE COMPLIANCE OF <br />EXISTING EQUIPMENT. <br />POWER CONTROL SYSTEM (PCS): <br />DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR SUPPLIED BY THE POWER PRODUCTION <br />SOURCES <br />SHALL COMPLY WITH ARTICLE 705.12. <br /> - 180A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL <br /> - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) <br />General Notes: <br />COLD WATER GAS BOND <br />INTERCONNECTION DEVICE BREAKER CONDUCTORS IN TWO SEPARATE <br />CONDUITS. <br />IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION <br />APPLIES PER 2019 CEC 210.12 <br />ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, <br />GROUPED, AND EQUIPPED WITH A 2-POLE OCPD BREAKER PER CEC <br />210.4(B,D).