My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1925 W Deerfield Rd - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Deerefield Rd
>
1925 W Deerefield Rd
>
1925 W Deerfield Rd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:50:34 AM
Creation date
2/24/2026 10:50:24 AM
Metadata
Fields
Template:
Plan
Permit Number
101126280
Full Address
1925 W Deerefield Rd
Street Number
1925
Street Direction
W
Street Name
Deerefield
Street Suffix
Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
INVERTER CALCULATIONS <br />EACH INVERTER HAS THE FOLLOWING VALUES WHICH ARE CALCULATED FOLLOWING THESE FORMULAS: <br />INVERTER X: <br />{[((TEMP COEF VOC) X (VOC)) / 100] X (LOW TEMP - STC TEMP) + VOC} * (# <br />MODULES / STRING) <br />INVERTER POWERWALL 3 1707000-XX-Y <br />ALLOWABLE BACKFEED: <br /> MAX ALLOWED TOTAL GENERATION BACKFEED OCPD = <br /> MAIN BREAKER RATING = 225 A <br /> 125 A ≤ 225 A INTERCONNECTION <br /> MEETS CEC 2022 705.13 REQUIREMENTSWIRE CALCULATIONS <br />WIRE AMPACITY CALCULATED FROM CEC 310.16/310.17 AS APPROPRIATE WITH AMBIENT TEMPERATURE <br />CALCULATIONS FROM CEC 310.15(B)(1) AND RACEWAY FILL ADJUSTMENTS FROM CEC 310.15(C)(1). CONDUIT <br />ON THE ROOF SHALL BE INSTALLED NO LESS THAN 1" ABOVE THE ROOF DECK. PV CIRCUIT CONDUCTOR <br />AMPACITY IS CONSTRAINED USING THE 75°C COLUMN WITH THE CONTINUOUS DUTY UPRATING OR THE 90°C <br />COLUMN WITH THE RELEVANT AMBIENT TEMPERATURE AND RACEWAY FILL ADJUSTMENTS WITHOUT THE <br />CONTINUOUS DUTY UPRATING PER 690.8(B), WHICHEVER IS THE LOWER VALUE WILL GOVERN CONDUCTOR <br />SIZING. NON-PV CIRCUIT CONDUCTORS USE THE AMPACITY IN THE 75°C COLUMN OR THE 90°C COLUMN WITH <br />THE RELEVANT AMBIENT TEMPERATURE AND RACEWAY FILL ADJUSTMENTS, WHICHEVER IS LESS (110.14(C) & <br />310.15(A)(2)). THE RATING OF THE CONDUCTOR AFTER ADJUSTMENTS SHALL BE GREATER THAN, OR EQUAL <br />TO, THE CONTINUOUS DUTY UPRATED CURRENT. <br />CALC EX: WIRE AMPACITY X AMBIENT TEMP. CORR. FACTOR X CONDUIT FILL ADJ. FACTOR >= OUTPUT <br />CURRENT <br />PAGE <br />REV: A 12/22/2025 <br />TED YAMADA <br />1925 W DEERFIELD RD, SANTA <br />ANA, CA, 92704 <br />PROJECT NUMBER: <br /> 109R-925YAMA PR-3004737100 <br />SHEET <br />DESIGNER: <br />MEGHA S <br />CUSTOMER RESIDENCE: <br />TEL. (714) 550-6636 <br />APN: 412-531-54 <br />(415) 580-6920 ex3 <br />PV-4.1 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />ELECTRICAL CALCS
The URL can be used to link to this page
Your browser does not support the video tag.