My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1925 W Deerfield Rd - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Deerefield Rd
>
1925 W Deerefield Rd
>
1925 W Deerfield Rd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:50:34 AM
Creation date
2/24/2026 10:50:24 AM
Metadata
Fields
Template:
Plan
Permit Number
101126280
Full Address
1925 W Deerefield Rd
Street Number
1925
Street Direction
W
Street Name
Deerefield
Street Suffix
Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
BACKUP LOADS <br />LOAD BREAKER RATING <br />(AMPS)LABEL DEMAND <br />LOAD <br />1 15A-1P SEC 1440 W <br />2 20A-1P SEC 1500 W <br />3 20A-1P GDO 1500 W <br />4 20A-1P KIT 1500 W <br />5 20A-1P DW 1500 W <br />6 20A-1P KIT 1500 W <br />7 20A-1P MICRO 1500 W <br />8 20A-1P GD 1500 W <br />9 20A-1P REFRI 1500 W <br />10 20A-1P LAUNDRY 1500 W <br />11 20A-1P GFI 1500 W <br />12 20A-1P HOOD 1500 W <br />13 20A-1P D/R 1500 W <br />14 20A-1P SPA 1500 W <br />15 20A-1P GFI 1500 W <br />16 20A-1P FAU 1920 W <br />17 20A-1P FAU 1920 W <br />18 20A-1P GFI 1500 W <br />19 20A-1P LIGHTS/RECEPTABLES 1500 W <br />20 20A-1P GFI 1500 W <br />21 20A-1P REFRI 1500 W <br />22 20A-2P LIGHTS/RECEPTABLES 86 W <br />23 40A-2P RANGE 86 W <br />24 40A-2P AC 86 W <br />25 30A-2P OVEN 5760 W <br />ELECTRICAL CALCULATIONS FOR BACKED UP LOADS <br />ALL BACKED UP LOADS ABOVE IN THE BACKED UP LOADS PANEL ARE RELOCATED FROM THE MAIN SERVICE PANEL. <br />BACKED UP LOADS CALCULATION: <br />(7680 VA)/ 240V = 32 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15. <br />THE MAXIMUM CURRENT FOR ALL SMALL APPLIANCES LOADS IS 32 A. <br />(MAX LOADS OUTPUT) X (CONTINUOUS LOADS) = <br />32A X 1.25 = 40 A; <br />BACKED UP LOADS PANEL BREAKER = 125 A <br />40 A < 125 A. <br />THEREFORE, THE AMPERAGE OF THE BACKED UP LOADS IS LESS THAN THAT OF THE OCPD. <br />AC WIRE SIZING FOR BACKED UP LOADS PANEL: <br />MAX AC OUTPUT CURRENT = (MAX BACKUP LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = <br />32A X 1.25 = 40A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X <br />(CONDUCTOR AMPACITY)[TABLE 310.16] = <br />0.91 X 0.45 X 55A =22.5225A <br />TERMINAL RATING[110.14(C)] = <br />8 AWG, , 75°C RATED = 50A <br />40A < 50A → TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />22.5225A < 40A → 8AWG AMPACITY OK <br />THEREFORE 8 AWG IS SUFFICIENT. <br />CONDUIT LENGTH OF THE BACKED UP LOADS CONDUIT. <br /> <br /> <br />PAGE <br />REV: A 12/22/2025 <br />TED YAMADA <br />1925 W DEERFIELD RD, SANTA <br />ANA, CA, 92704 <br />PROJECT NUMBER: <br /> 109R-925YAMA <br />SHEET <br />DESIGNER: <br />MEGHA S <br />CUSTOMER RESIDENCE: <br />TEL. (714) 550-6636 <br />APN: 412-531-54 <br />(415) 580-6920 ex3 <br />PV-4.2 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />BACKUP LOAD CALCS