My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3414 S Timber St & Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Timber St
>
3414 S Timber St Unit# 2
>
3414 S Timber St & Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:50:34 AM
Creation date
2/24/2026 10:50:24 AM
Metadata
Fields
Template:
Plan
Permit Number
101125316
Full Address
3414 S Timber St Unit# 2
Street Number
3414
Street Direction
S
Street Name
Timber
Street Suffix
St
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATUM EAST <br />DATUM EAST <br />EXTERIOR PLAN NOTES: <br />1.WINDOWS, DOORS, AND TRIMS WILL BE COMPATIBLE AND MATCHING WITH THE <br />PRIMARY SINGLE-FAMILY RESIDENCE. <br />2. PAINT COLOR SECTION FOR TRIMS EXTERIOR SHALL MATCH THE EXISTING <br />PRIMARY HOUSE. <br />DRAINAGE NOTES: <br />Drainage Notes: <br />a. Provisions shall be made for contributory drainage at all times. <br />b. Owner shall maintain drainage devices and keep free of debris. <br />c. A property line survey, prepared by a California licensed land surveyor may be required by the building official <br /> based upon site conditions in accordance with LACBC Section 108.1. <br />d. No work is allowed within the protected zone of oak tree without an oak tree report and permit. <br />e. Finish floor shall be a minimum of 8 inches above finish grade immediately outside the building. <br />f. Provide a minimum grade fall of 6 inches within the first 10 feet (5%slope) <br />g. Downspouts shall discharge at least 5 feet away from exterior walls & from property lines. <br />h. Cross lot drainage is not permitted. <br />i. An excavation/encroachment permit is required for construction and/or discharge of drainage within public right-of-way. <br />j. All landscaping requires a smart irrigation controller which shall be installed at the time of final inspection and shall <br /> comply with the following: <br />f. Controller shall be weather- or soil moisture-based controllers that automatically adjust irrigation in response to changes <br /> in plants’ need as weather conditions change. <br />g. Weather-based controllers without integral rain sensors or communication system that account for local <br /> rainfall shall have a separate wired or wireless rain sensor which connects or communicates with <br /> the controllers. Soil moisture-based controllers are not required to have a rain sensor input. <br />k. Total proposed landscape area '0' square feet. <br />l. No easements on the property. <br />m. No slopes 3:1 or steeper within 40 feet of the proposed structure. <br />n. No grading is proposed outside of the building footprint.A-4 <br />EXTERIOR ELEVATIONS <br />Job # <br />Sheet No.: <br />Date <br />Ap <br />p <br />l <br />i <br />c <br />a <br />n <br />t <br /> <br />: <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />f <br />o <br />r <br />: <br />Co <br />n <br />t <br />a <br />c <br />t <br />: <br />To <br />n <br />y <br /> <br />V <br />u <br />Ma <br />s <br />t <br />e <br />r <br /> <br />C <br />o <br />n <br />s <br />t <br />r <br />u <br />c <br />t <br />i <br />o <br />n <br />SEAL: <br />SHEET DESCRIPTION : <br />Te <br />l <br />. <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />5 <br />6 <br />8 <br />- <br />5 <br />4 <br />4 <br />4 <br />SCALE: <br />REVISIONS <br />DATENO: REVISIONS <br />AT <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />34 <br />1 <br />4 <br /> <br />S <br /> <br />T <br />I <br />M <br />B <br />E <br />R <br /> <br />S <br />T <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br /># <br />2 <br /> <br />( <br />A <br />D <br />U <br />) <br />34 <br />1 <br />4 <br /> <br />S <br /> <br />T <br />I <br />M <br />B <br />E <br />R <br /> <br />S <br />T <br /> <br />( <br />S <br />F <br />R <br />) <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />. <br /> <br />C <br />A <br />. <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />1 EXISTING FRONT ELEVATION <br />SOUTH VIEW <br />8' <br />ENTRY LEVEL FCE <br />ENTRY LEVEL FFE <br />8'-2" <br />T.O SLAB <br />16'-11" <br />18'-2" <br />8' <br />ENTRY LEVEL FCE <br />ENTRY LEVEL FFE <br />5'-6" <br />T.O SLAB <br />16'-11" <br />2 EXISTING LEFT ELEVATION <br />WEST VIEW <br />(E) SHINGLE OWENS CORNING ROOFING <br />CLASS A /UL790 <br />FM 4474 ATSM D3462 <br />(E) SHINGLE OWENS CORNING ROOFING <br />CLASS A /UL790 <br />FM 4474 ATSM D3462 <br />72 <br />2 <br />1 <br /> <br />G <br />a <br />r <br />d <br />e <br />n <br /> <br />G <br />r <br />o <br />v <br />e <br /> <br />B <br />l <br />v <br />d <br />, <br /> <br />G <br />a <br />r <br />d <br />e <br />n <br /> <br />G <br />r <br />o <br />v <br />e <br />, <br /> <br /># <br />J <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />4 <br />1 <br />Te <br />l <br />. <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />5 <br />6 <br />8 <br />- <br />5 <br />4 <br />4 <br />4 <br />(n) windows <br />min 4" trim <br />NAVAJO WHITE <br />STUCCO <br />(Match Existing) <br />NAVAJO WHITE <br />STUCCONAVAJO WHITE <br />STUCCO <br />11/24/25 <br />N2308 <br />AS NOTED <br />11.24.251 REVISIONS <br />ROOFING: <br />SHINGLE OWENS CORNING ROOFING <br />CLASS A /UL790 <br />FM 4474 ATSM D3462 <br /> Mystic Gray <br />CRCC# 0890-0032 <br /> SOLAR <br />REFLECTANCE 0.22 <br />THERMAL: 0.93 SRI: 23 <br />ROOF SHEATHING NOTES: <br />SHINGLE OWENS CORNING ROOFING WITH <br />30# FELT UNDERLAY OVER 1/2" CDX INDEX 32/16 W/8d NAILS @ <br />6" O.C. PERIMETER, 12" O.C. FIELD. (UL 2218). (ROOF COVERING <br />SHALL BE CLASS A