Laserfiche WebLink
DATUM DATUM <br />DATUM DATUM <br />124 <br />124 <br />124 <br />124 <br />12 4 <br />12 4 <br />12 4 <br />12 4 <br />EXTERIOR PLAN NOTES: <br />1.WINDOWS, DOORS, AND TRIMS WILL BE COMPATIBLE AND MATCHING WITH THE <br />PRIMARY SINGLE-FAMILY RESIDENCE. <br />2. PAINT COLOR SECTION FOR TRIMS EXTERIOR SHALL MATCH THE EXISTING <br />PRIMARY HOUSE. <br />DRAINAGE NOTES: <br />Drainage Notes: <br />a. Provisions shall be made for contributory drainage at all times. <br />b. Owner shall maintain drainage devices and keep free of debris. <br />c. A property line survey, prepared by a California licensed land surveyor may be required by the building official <br /> based upon site conditions in accordance with LACBC Section 108.1. <br />d. No work is allowed within the protected zone of oak tree without an oak tree report and permit. <br />e. Finish floor shall be a minimum of 8 inches above finish grade immediately outside the building. <br />f. Provide a minimum grade fall of 6 inches within the first 10 feet (5%slope) <br />g. Downspouts shall discharge at least 5 feet away from exterior walls & from property lines. <br />h. Cross lot drainage is not permitted. <br />i. An excavation/encroachment permit is required for construction and/or discharge of drainage within public right-of-way. <br />j. All landscaping requires a smart irrigation controller which shall be installed at the time of final inspection and shall <br /> comply with the following: <br />f. Controller shall be weather- or soil moisture-based controllers that automatically adjust irrigation in response to changes <br /> in plants’ need as weather conditions change. <br />g. Weather-based controllers without integral rain sensors or communication system that account for local <br /> rainfall shall have a separate wired or wireless rain sensor which connects or communicates with <br /> the controllers. Soil moisture-based controllers are not required to have a rain sensor input. <br />k. Total proposed landscape area '0' square feet. <br />l. No easements on the property. <br />m. No slopes 3:1 or steeper within 40 feet of the proposed structure. <br />n. No grading is proposed outside of the building footprint. <br />8" MIN. <br />A-3 <br />EXTERIOR ELEVATIONS <br />Job # <br />Sheet No.: <br />Date <br />Ap <br />p <br />l <br />i <br />c <br />a <br />n <br />t <br /> <br />: <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />f <br />o <br />r <br />: <br />Co <br />n <br />t <br />a <br />c <br />t <br />: <br />To <br />n <br />y <br /> <br />V <br />u <br />Ma <br />s <br />t <br />e <br />r <br /> <br />C <br />o <br />n <br />s <br />t <br />r <br />u <br />c <br />t <br />i <br />o <br />n <br />SEAL: <br />SHEET DESCRIPTION : <br />Te <br />l <br />. <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />5 <br />6 <br />8 <br />- <br />5 <br />4 <br />4 <br />4 <br />SCALE: <br />REVISIONS <br />DATENO: REVISIONS <br />AT <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />72 <br />2 <br />1 <br /> <br />G <br />a <br />r <br />d <br />e <br />n <br /> <br />G <br />r <br />o <br />v <br />e <br /> <br />B <br />l <br />v <br />d <br />, <br /> <br />G <br />a <br />r <br />d <br />e <br />n <br /> <br />G <br />r <br />o <br />v <br />e <br />, <br /> <br /># <br />J <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />4 <br />1 <br />Te <br />l <br />. <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />5 <br />6 <br />8 <br />- <br />5 <br />4 <br />4 <br />4 <br />34 <br />1 <br />4 <br /> <br />S <br /> <br />T <br />I <br />M <br />B <br />E <br />R <br /> <br />S <br />T <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br /># <br />2 <br /> <br />( <br />A <br />D <br />U <br />) <br />34 <br />1 <br />4 <br /> <br />S <br /> <br />T <br />I <br />M <br />B <br />E <br />R <br /> <br />S <br />T <br /> <br />( <br />S <br />F <br />R <br />) <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />. <br /> <br />C <br />A <br />. <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />1 LEFT ELEVATION <br />SOUTH VIEW 2 FRONT ELEVATION <br />WEST VIEW <br />3 RIGHT ELEVATION <br />NORTH VIEW 4 BACK ELEVATION <br />EAST VIEW <br />8' <br />ENTRY LEVEL FCE <br />ENTRY LEVEL FFE <br />3'-1" <br />ATTIC LEVEL FCE <br />8"T.O SLAB <br />8' <br />ENTRY LEVEL FCE <br />ENTRY LEVEL FFE <br />2'-3" <br />8"T.O SLAB <br />8' <br />ENTRY LEVEL FCE <br />ENTRY LEVEL FFE <br />5'-6" <br />8"T.O SLAB <br />8' <br />ENTRY LEVEL FCE <br />ENTRY LEVEL FFE <br />5'-6" <br />8"T.O SLAB <br />6'-5" <br />2'-8" <br />6'-8"6'-8" <br />2'-8" <br />6'-8" <br />2'-8" <br />14'-2"14'-2" <br />VENT PIPE <br />VENT PIPE <br />LAUNDRY VENT <br />VENT PIPE <br />ENTRY PORCH <br />ENTRY PORCH <br />VENT PIPE <br />VENT PIPE <br />LAUNDRY VENT <br />14'-2"14'-2" <br />WATER HEATER <br />LOCATION <br />VENT PIPE <br />LAUNDRY VENT <br />6'-8" <br />STUCCO <br /> COLOR MATCH <br />(N) SHINGLE OWENS CORNING ROOFING <br />CLASS A /UL790 <br />FM 4474 ATSM D3462 <br />(MATCH EXISTING) <br />(N) SHINGLE OWENS CORNING ROOFING <br />CLASS A /UL790 <br />FM 4474 ATSM D3462 <br />(MATCH EXISTING) <br />(N) SHNGLE OWENS CORNING ROOFING <br />CLASS A /UL790 <br />FM 4474 ATSM D3462 <br />(MATCH EXISTING) <br />(N) SHINGLE OWENS CORNING ROOFING <br />CLASS A /UL790 <br />FM 4474 ATSM D3462 <br />(MATCH EXISTING) <br />NAVAJO WHITE <br />(MATCH EXISTING) <br />8' <br />- <br />6 <br />" <br />9'-8" <br />2'2'-6" <br />1'-6" <br />Provide one-hour protection on the <br />underside of eave when eaves <br />projected into the 5-ft of fire <br />separation distance, TYP. <br />1 <br />11/24/25 <br />N2308 <br />AS NOTED <br />11.24.251 REVISIONS <br />3' <br />4' <br />EGRESS <br />TEMP GLAZ. <br />TEMP GLAZ. <br />1'-1" <br />2'-8"32 <br />4 TEMP GLAZ. <br />TEMP GLAZ. <br />2'-6" <br />1'-6" <br />4 <br />TEMP GLAZ. <br />1 <br />TEMP GLAZ.EGRESS <br />1 <br /> AC/ MINI SPLIT <br />SYSTEM W/ HEAT <br />CONDENSER <br /> (EFF EER/CEER= <br />20/EFF SEER=18) <br />W/ 4" CONC. PAD <br />REFER TO NOTE <br />#14 <br />THRESHOLD: <br />MAX = 7" / <br />MIN. 1.5" <br />THRESHOLD <br />1 1 <br />NAVAJO WHITE <br />STUCCO <br />(Match Existing SFR)NAVAJO WHITE <br />STUCCO <br />(Match Existing SFR) <br />NAVAJO WHITE <br />STUCCO <br />(Match Existing SFR) <br />NAVAJO WHITE <br />STUCCO <br />(Match Existing SFR) <br />ROOFING: <br />SHINGLE OWENS CORNING ROOFING <br />CLASS A /UL790 <br />FM 4474 ATSM D3462 <br /> Mystic Gray <br />CRCC# 0890-0032 <br /> SOLAR <br />REFLECTANCE 0.22 <br />THERMAL: 0.93 SRI: 23 <br />ROOF SHEATHING NOTES: <br />SHINGLE OWENS CORNING ROOFING WITH <br />30# FELT UNDERLAY OVER 1/2" CDX INDEX 32/16 W/8d NAILS @ <br />6" O.C. PERIMETER, 12" O.C. FIELD. (UL 2218). (ROOF COVERING <br />SHALL BE CLASS A <br /> 44" MAX 44" MAX <br /> 44" MAX <br /> 44" MAX