© Gensler
<br />Date Description
<br />Project Name
<br />Project Number
<br />Description
<br />Scale
<br />Seal / Signature
<br />2021
<br />Tel 949.863.9434
<br />Fax 949-553-1676
<br />4675 MacArthur Court
<br />Suite 100
<br />Newport Beach, CA
<br />92600
<br />USA
<br />BI
<br />M
<br />
<br />3
<br />6
<br />0
<br />:
<br />/
<br />/
<br />0
<br />0
<br />7
<br />.
<br />3
<br />7
<br />5
<br />7
<br />.
<br />0
<br />0
<br />0
<br />
<br />-
<br />
<br />C
<br />a
<br />r
<br />i
<br />b
<br />o
<br />u
<br />
<br />I
<br />n
<br />d
<br />u
<br />s
<br />t
<br />r
<br />i
<br />e
<br />s
<br />
<br />-
<br />
<br />3
<br />r
<br />d
<br />
<br />&
<br />
<br />B
<br />r
<br />o
<br />a
<br />d
<br />w
<br />a
<br />y
<br />/
<br />3
<br />R
<br />D
<br />-
<br />B
<br />_
<br />A
<br />R
<br />C
<br />H
<br />_
<br />W
<br />E
<br />S
<br />T
<br />_
<br />R
<br />2
<br />0
<br />.
<br />r
<br />v
<br />t
<br />07.3757.000
<br />3rd & Broadway
<br />301 N. Broadway, Santa Ana, CA
<br />09/21/2021 Issue for Plan Check
<br />A 12/10/2021 Reissue for Plan Check
<br />B 07/11/2022 Reissue for Plan Check
<br />C 06/17/2024 REVISION TO PERMIT
<br />R1-SP-102
<br />POOL & SPA EQUIPMENT PLAN
<br />S
<br />CIRCULATION EQUIPMENTC
<br />SANITATION EQUIPMENT
<br />NOTE: PUMP VIBRATION ISOLATORS: SEE: SP-504 DETAIL 1. (QTY. 1 PER PUMP)
<br />C1.CIRCULATION PUMP - POOL (P-1): PENTAIR POOL PRODUCT. MODEL:
<br />WHISPERFLOXF VS, #022035, 5 HP,THREE PHASE, 208V, 13 AMPS, (QTY. 1).
<br />C2.CIRCULATION PUMP - SPA (P-2): PENTAIR POOL PRODUCT. MODEL:
<br />WHISPERFLOXF VS, #022035, 5 HP, THREE PHASE, 208V, 13 AMPS. (QTY. 1)
<br />C3.CIRCULATION FILTERS - POOL: PENTAIR POOL PRODUCT. MODEL: TRITON
<br />SAND, 4.9 SQFT, TR100C, #140315, (QTY. 1) SEE: SP-504 DETAIL 2
<br />C4.CIRCULATION FILTERS - SPA: PENTAIR POOL PRODUCT. MODEL: TRITON
<br />SAND, 7.0 SQFT, TR140C, #140316, (QTY. 1)* FILTER MOUNTING ANCHORS,
<br />SEE: SHEET SP-504 DETAIL 2, BACKWASH VALVE, FULL FLOW XF MODEL
<br />#263010, (QTY. 1)
<br />C5. HEATER - POOL & SPA: PENTAIR POOL PRODUCT - GAS FIRED MODEL ETi 400
<br />#46113, INPUT RATING OF 400,000 BTU/HR, NATURAL GAS. 120V, 4.0 AMPS,
<br />WATER CONNECTION: 2-INCH NPT, GAS: 3/4-INCH NPT. SEE: SHEET SP-503,
<br />DETAIL 5, 11, 12, 16 (QTY. 2)
<br />C6.BOOSTER PUMP - SPA (P-3): PENTAIR POOL PRODUCT. MODEL:
<br />WHISPERFLOXF VS, #022035, 5 HP, 208V, 13 AMPS. (QTY. 1).
<br />S1.CHEMISTRY CONTROLLER - POOL & SPA: PENTAIR; COMMERCIAL
<br />INTELLICHEM, #521357. SEE: SHEET SP-503, DETAIL 1. (QTY. 2)
<br />S2.SECONDARY SANITIZER; API: E-Z POOL PRO & REVIVE PRO: CONTRACTOR
<br />TO SUPPLY THE FOLLOWING: 20 LB. EZP20 WITH 30 GALLON CHEMICAL
<br />TANK AND CHEMICAL FEED PUMP (E), WITH FLANGED MOUNT MIXER PN#
<br />42821. (QTY. 1 EACH) CONTACT DAVE STUART (DAVES@APIWATER.COM)
<br />PH: 561 339 4192. SEE: SHEET SP-503, DETAIL 4. (QTY. 2)
<br />S3.CHLORINE & PH ACID CONTROL PUMPS: PRODUCT OF STENNER PUMP
<br />COMPANY. MODEL #45MPH10, UP TO 10 GALLONS PER DAY. SEE: SP-503
<br />DETAIL 2 & 3 (QTY. 2 - 1 BACKUP)
<br />S4.FEED TANKS: PRODUCT OF ASSMANN, MODEL #IMT 20, 20 GALLON,
<br />DOUBLE WALL, CLOSED TOP, 40 CFR-264.193. SEE: SP-503, DETAIL 2 & 3
<br />(QTY. 2)
<br />S5. CHEMICAL SEPARATION WALL: CONSTRUCTED WITH FIRE RESISTANT
<br />MATERIALS PER DETAIL COORDINATE FINAL SIZE IN EQUIPMENT ROOM,
<br />SEE SHEET SP-503, DETAIL 6.
<br />S6.EYEWASH STATION: HAWS, MODEL# 7460 OR EQUAL PER MEP.SEE SHEET
<br />SP-504, DETAIL 12.
<br />S7. FILTER BACKWASH RISER: CONNECTION TO SEWER PROVIDED BY MEP,
<br />PROVIDE 6" MIN. AIR GAP, SEE: SHEET SP-503, DETAIL 9.
<br />V1.PRESSURE-VACUUM GAUGES: PRODUCT OF SUPER PRO. MODEL
<br />#SPG-06-1001 (PRESSURE) & SPG-06-1008 (PRESSURE) INDUSTRIAL
<br />GAUGE WITH 2" DIAL, 316 S.S CASE, GLYCERIN FILLED. RANGE OF 0-60 PSI
<br />FOR PRESSURE, AND 0-30 INCHES OF MERCURY FOR VACUUM.SEE:
<br />SHEET SP-503, DETAIL 15 (QTY. 6)
<br />V2.DIVERTER VALVES: PENTAIR. 2.5-INCH TO 3-INCH, 2-PORT AND 2.5" TO 3",
<br />3-PORT. MAX PRESSURE OF 50 PSI. (QTY. PER PLAN)
<br />V3.FLOW METER/CHECK VALVE: PRODUCT OF H2FLOW. MODEL #FLOWVIS.
<br />(QTY. 2) SEE: SHEET SP-503 DETAIL 8.
<br />V4.BALL VALVES: ASAHI. MODEL TYPE: TRUE UNION, 1-INCH TO 3-INCH, WITH
<br />VITON SEALS AND TEFLON SEATS. (QTY. AS NEEDED)
<br />V5.BACK-FLOW PREVENTER: RPZ COORDINATED ITEM PROVIDED BY MEP.
<br />ONE FOR EACH AUTO FILL SYSTEM, SEE: SHEET SP-503, DETAIL 8 (QTY. 2)
<br />VALVES & GAUGESV
<br />E1.INTELLICENTER CONTROL: POWER CENTER - #522042, i10D
<br />PERSONALITY KIT - #521915, ESO BUTTON WITH ALARM - #ESO2, SPA
<br />BUTTON - #RCS1, #MODESO ESO PCB. (QTY. 1)
<br />E2.HEATER EM. OFF SWITCH:COORDINATE FINAL LOCATION NEAR DOOR
<br />AS REQUIRED BY THE CMC, SEE HEATER NOTES ON SP-503, DETAIL 5
<br />(QTY. 1)
<br />ELECTRICALE
<br />PIPE ELEMENTSPE
<br />PE1. PIPE MOUNTING: STAINLESS STEEL UNI-STRUT WITH 1/2" S.S. NUT AND
<br />SQUARE WASHERS. SEE: SHEET SP-503, DETAIL 1 & 2. [NOT SHOWN]
<br />PE2. VAULT PENETRATION SEAL: LINK SEAL; COORDINATE PENETRATION SIZE IN
<br />VAULT WITH SEAL TYPE, SEE: SHEET SP-503, DETAIL 3. [NOT SHOWN]
<br />PE3. FLOOR PENETRATION SEAL: FIRE RATED PER FLOOR REQUIREMENTS
<br />COORDINATE, SEE: SHEET SP-505 DETAIL 1. [NOT SHOWN]
<br />Scale: 1/2" = 1'
<br />POOL & SPA PUMP ROOM - 6TH FLOOR - (ENLARGED PLAN)1
<br />CHEMICAL EQUIPMENT:
<br />CE1. POOL EQUIPMENT ROOM SIGNS & SAFETY EQUIPMENT [NOT SHOWN]
<br /> POOL CHEMICAL SIGNS; PRODUCT OF COMPLIANCY SIGNS:
<br /> DANGER - AUTHORIZED PERSONNEL ONLY - #CUSTOM
<br /> DANGER - HAZARDOUS POOL CHEMICALS - #ODE-7756
<br /> 704 SIGN - SODIUM HYPOCHLORITE (NAOCL) W/ CAS# - 7681-52-9
<br /> 704 SIGN - MURIATIC ACID ONLY (HCL) W/ CAS# - 7647-01-0
<br />CE2. EQUIPMENT ROOM SAFETY EQUIPMENT [NOT SHOWN]
<br /> RESPIRATOR MASK: U-LINE, 3M HALF-FACE MASK - #H-1081
<br /> SAFETY GLASSES: OTG, CLEAR - #S-17940
<br /> NEOPRENE CHEMICAL RESISTANT APRON: U-LINE - #S-18815
<br /> NEOPRENE CHEMICAL RESISTANT GLOVES: ULINE - #S-11434
<br /> TESTING KIT; RECREONICS #56-192. TAYLOR COMPLETE 2005
<br />CE
<br />EQUIPMENT NOTES:
<br />1.THE EQUIPMENT SHALL BE SET ON A 6" MIN. CONCRETE HOUSE-KEEPING
<br />PAD THAT POSITIVELY SLOPES TOWARD THE FLOOR DRAINAGE SYSTEM,
<br />PAD INSTALLED BY OTHERS.
<br />2.THE EYE-WASH STATION IS FOR COORDINATION ONLY, INSTALLED AND
<br />PROVIDED BY OTHERS.
<br />3.THE HEATER SHALL BE PROVIDED WITH A SYSTEM THAT DETECTS AND
<br />MONITORS CARBON MONOXIDE IN THE EQUIPMENT ROOM, PROVIDED
<br />AND INSTALLED BY OTHERS.
<br />4.ADDITIONAL ITEMS INSTALLED BY OTHERS: CHEMICAL WALL, BACKWASH
<br />STANDPIPE, BACK-FLOW DEVICE, HEATER VENTING, HEATER PRESSURE
<br />RELIEF DRAIN AND ROUTING. FLOOR DRAIN, CO ALARM.
<br />5.EQUIPMENT 3D ISOMETRIC IS FOR DIAGRAM ONLY. INSTALL MAY VARY
<br />UPON FINAL SITE CONDITIONS.
<br />6.G.C. TO PROVIDE GFCI PROTECTED 110V OUTLETS IN POOL EQUIPMENT
<br />AREA FOR GENERAL MAINTENANCE USE .
<br />7.ACCESSIBILITY. ALL FILTERS, VALVES, PUMPS, STRAINERS AND
<br />EQUIPMENT REQUIRING ADJUSTMENT SHALL BE READILY ACCESSIBLE
<br />FOR REPAIR AND REPLACEMENT.
<br />8.RECIRCULATION PIPING SYSTEM AND COMPONENTS - PIPING SYSTEMS,
<br />INCLUDING ALL PARTS AND FITTINGS OTHER THAN INLET DEVICES OR
<br />VENTURI THROATS, SHALL BE SIZED SO THAT THE FLOW VELOCITY SHALL
<br />NOT EXCEED 10 FEET PER SECOND, EXCEPTING THAT THE FLOW
<br />VELOCITY SHALL NOT EXCEED 8 FEET PER SECOND IN ANY COPPER
<br />PIPING OR IN ANY PUMP SUCTION PIPING.
<br />9.PROVIDE LABELING FOR CHEMICAL LINES, EVERY CHANGE OF
<br />DIRECTION, PENETRATION AND 20' LABEL WITH CHEMICAL MANE AND
<br />DIRECTION OF FLOW.
<br />10.PROVIDE ONE 704 PLACARD ON ENTRY DOOR OF POOL EQUIPMENT ROOM
<br />TO INCLUDE CHEMICALS IN ROOM.
<br />11.CHEMICAL CONTAINERS TO BE LABELED WITH PROPER CHEMICAL NAME
<br />AND CONCENTRATION.
<br />Scale: NTS
<br />POOL & SPA PUMP ROOM - 6TH FLOOR - EQUIPMENT ISO3
<br />Scale: NTS
<br />POOL & SPA PUMP ROOM - 6TH FLOOR - EQUIPMENT ISO2
<br />HEATER VENTING/INTAKE
<br />BY OTHERS
<br />C4
<br />C3
<br />C3
<br />C2
<br />C1
<br />C6
<br />C4
<br />C6
<br />C2
<br />C1
<br />C5
<br />C5
<br />HEATER VENTING/INTAKE
<br />BY OTHERS
<br />S1
<br />S1
<br />S7
<br />V5
<br />S5
<br />S5
<br />S6
<br />S6
<br />S2
<br />C5
<br />C5
<br />S3
<br />S3
<br />S2
<br />V5
<br />V1
<br />V3
<br />E2 E1
<br />S5
<br />FLOOR DRAIN
<br />BY OTHERS
<br />FLOOR SINK BY OTHERS
<br />ELECTRICAL PANEL
<br />& 3FT SETBACK
<br />C