Laserfiche WebLink
1" POOL WATER LEVEL DRAIN <br />BYPASS TO BACKWASH <br />RISER, PROVIDE AIR GAP <br />1- <br />1 <br />/ <br />2 <br />" <br />SUCTION CONNECTION <br /> PUMP <br />VIBRATION ISOLATORS <br />STAINLESS STEEL PLATE <br />DISCHARGE TO FILTER1" BALL VALVE (EPDM SEAL) <br />COMMON NAME CHEMICAL NAME % <br />COMP.CAS #FORM QUANT. <br />STORED <br />OPEN/CLOSED <br />SYSTEM STORAGE HAZ. <br />CLASS SIGNS <br />SODIUM <br />HYPOCHLORITE 7681-52-9 0 GAL.20 GAL.CHEM. ROOM IRRITANT MSDSSODIUM <br />HYPOCHLORITE 12.5% <br />MURIATIC ACID 7647-01-0 LIQUID <br />NOTE: QUANTITIES OF CHEMICALS DO NOT EXCEED THE QUANTITIES LISTED IN IBC TABLES 307.1 (1) & 307.1 (2) <br />20 GAL.CORROSIVEHYDROCHLORIC <br />ACID 25%CHEM. ROOM MSDS0 GAL. <br />CHEMICALS <br />RATING EXPLANATION GUIDE <br />4 <br />3 <br />2 <br />1 <br />0 <br />RATING HEALTH HAZARD FLAMMABILITY HAZARD REACTIVITY HAZARD <br />NOTE: <br />1.CONFORM SIGNAGE WITH LOCAL FIRE MARSHALL AND/OR BUILDING CODES PRIOR TO INSTALLATION <br />SIGNS SHALL CONFORM TO NFPA 704. <br />2.SIGNS SHALL BE SIZED AND COLORED PER CODE & MOUNTED @ 60" ABOVE DOOR IN CHEMICAL ROOM. <br />HEALTH <br />HAZARD <br />(BLUE) <br />FLAMMABILITY <br />HAZARD <br />(RED) <br />REACTIVITY <br />HAZARD <br />(YELLOW) <br />SPECIFIC <br />HAZARD <br />(WHITE) <br />LEGEND <br />CAN BE LETHAL <br />CAN CAUSE SERIOUS <br />OR PERMANENT INJURY <br />CAN CAUSE TEMPORARY <br />INCAPACITATION OR <br />RESIDUAL INJURY <br />NO HAZARD <br />CAN CAUSE <br />SIGNIFICANT IRRITATION <br />WILL NOT BURN STABLE <br />IGNITES AT ABOVE 200° F <br />IGNITES AT ABOVE 100°F, <br />BELOW 200° F <br />IGNITIES AT ABOVE 73° F, <br />BELOW 100° F <br />EXTREMELY IGNITIES <br />73° F, BELOW 100° F <br />MAY EXPLODE AT <br />NORMAL TEMPERATURES <br />& PRESSURES <br />MAY EXPLODE AT HIGH <br />TEMPERATURES OR SHOCK <br />VIOLENT CHEMICAL CHANGE <br />AT HIGH TEMPERATURES OR <br />PRESSURES <br />NORMALLY STABLE, HIGH <br />TEMPERATURES MAKE <br />UNSTABLE <br />LIQUID <br />768mm <br />30 1/4" <br />FLOOR LINE <br />14 3/4" <br />375mm <br />11 1/4" <br />286mm <br />4X Ø 5/16" <br />8mm <br />27 15/16" <br />710mm27" MIN <br />686mm <br />32mm <br />1 1/4" <br />2 <br />(SUPPLIED) <br />1 1/4" IPS <br />WASTE TRAP <br />1/2" IPS <br />(SUPPLIED) <br />TAILPIECE <br />1 1/4" OD <br />STRAINER <br />SUPPLY <br />1 1/4" IPS <br />WASTE <br />(BY OTHERS) <br />(SUPPLIED) <br />1 1/4" IPS(F) ELBOW <br />TRAP MUST BE <br />ACCESSIBLE <br />4 3/8" <br />111mm <br />1 1/2" <br />38mm <br />76mm <br />3" <br />727mm <br />28 5/8" <br />2" <br />51mm <br />23" <br />584mm <br />18 1/2" <br />470mm <br />12 7/8" <br />327mm <br />33" - 53" <br />838 mm - 1346 mm <br />FLOW PATTERN <br />2 <br />36" MAX <br />914mm <br />WARNING NO LIFEGUARD <br />ON DUTY - NO DIVING <br />PERSON HAVING CURRENTLY ACTIVE DIARRHEA OR HAVE HAD ACTIVE DIARRHEA <br />WITHIN THE PREVIOUS 14 DAYS SHALL NOT BE ALLOWED TO ENTER THE POOL WATER <br />NO ONE UNDER THE AGE OF 14 SHALL NOT ENTER THE POOL WITHOUT <br />A PARENT OR ADULT GUARDIAN IN ATTENDANCE <br />POOL HOURS: 9AM-10PM IN CASE OF <br />EMERGENCY DIAL:911 <br />POOL CAPACITY: XXX <br />HOTEL ADDRESS: XXXXXXXXXXXXXXXXXXXXXXXX <br />NEAREST EMEGENCY SERVICE <br />XXX-XXX-XXXX <br />POOL AREA RULES <br />FOR YOUR SAFETY, IT IS REQUIRED THAT <br />YOU OBSERVEE FOLLOWING: <br />·REGISTERED GUESTS ONLY <br />·RUNNING OR HORSEPLAY PROHIBITED <br />·APPROPRIATE SWIM WEAR REQUIRED <br />·DIVING STRICTLY PROHIBITED <br />·GLASSWARE IS NOT PERMITTED WITHIN THE POOL AREA <br />·NOT PETS ALLOWED <br />·ONLY FLEXIBLE SWIM-AIDS ARE PERMITTED <br />·BE AWARE OF DEPTH MARKINGS AT ALL TIMES <br />·REPORT UNSAFE CONDITIONS OR VIOLATIONS TO MANAGEMENT IMMEDIATELY <br />·ALWAYS PRACTICE WATER SAFETY AND COURTESY <br />·SHOWER BEFORE ENTERING THE POOL <br />·CHILDREN WHO ARE NOT TOILET TRAINED MUST WEAR SWIM DIAPERS <br />·INDIVIDUALS ASSUME THE RISK FOR ANY INJURIES SUSTAINED WHILE USING <br />THE POOL FACILITY AND WILL USE CAUTION IN THE POOL AREA <br />·ADA LIFT IS NOT A TOY <br />KEEP POOL GATE CLOSED <br />AT ALL TIMES <br />WARNING! <br />NO DIVING <br />SHALLOW WATER INJURIES MAY RESULT <br />POOL DECK SAFETY <br />EQUIPMENT LOCATION <br />ADA LIFT NOT A TOY <br />WARNING NO LIFEGUARD <br />ON DUTY - NO DIVING <br />PERSON HAVING CURRENTLY ACTIVE DIARRHEA OR HAVE HAD ACTIVE DIARRHEA <br />WITHIN THE PREVIOUS 14 DAYS SHALL NOT BE ALLOWED TO ENTER THE SPA WATER <br />NO ONE UNDER THE AGE OF 14 SHALL NOT ENTER THE SPA WITHOUT A <br />PARENT OR ADULT GUARDIAN IN ATTENDANCE <br />SPA HOURS: 9AM-10PM IN CASE OF <br />EMERGENCY DIAL:911 <br />SPA CAPACITY: XXX <br />HOTEL ADDRESS: XXXXXXXXXXXXXXXXXXXXXXXX <br />NEAREST EMEGENCY SERVICE <br />XXX-XXX-XXXX <br />SPA AREA RULES <br />FOR YOUR SAFETY, IT IS REQUIRED THAT <br />YOU OBSERVEE FOLLOWING: <br />·REGISTERED GUESTS ONLY <br />·RUNNING OR HORSEPLAY PROHIBITED <br />·APPROPRIATE SWIM WEAR REQUIRED <br />·DIVING STRICTLY PROHIBITED <br />·GLASSWARE IS NOT PERMITTED WITHIN THE SPA AREA <br />·NOT PETS ALLOWED <br />·ONLY FLEXIBLE SWIM-AIDS ARE PERMITTED <br />·BE AWARE OF DEPTH MARKINGS AT ALL TIMES <br />·REPORT UNSAFE CONDITIONS OR VIOLATIONS TO MANAGEMENT IMMEDIATELY <br />·ALWAYS PRACTICE WATER SAFETY AND COURTESY <br />·SHOWER BEFORE ENTERING THE SPA <br />·CHILDREN WHO ARE NOT TOILET TRAINED MUST WEAR SWIM DIAPERS <br />·INDIVIDUALS ASSUME THE RISK FOR ANY INJURIES SUSTAINED WHILE USING <br />THE POOL FACILITY AND WILL USE CAUTION IN THE POOL AREA <br />·ADA LIFT IS NOT A TOY <br />EMERGENCY SHUT-OFF <br />SWITCH & 15 MIN. TIMER <br />SPA WARNING <br />ELDERLY PERSONS, PREGNANT WOMEN, INFANTS, AND THOSE <br />WITH HEALTH CONDITIONS REQUIRING MEDICAL CARE SHOULD <br />CONSULT WITH A PHYSICIAN BEFORE ENTERING THE SPA. <br />UNSUPERVISED USE BY CHILDREN UNDER THE AGE OF 14 IS <br />PROHIBITED. WITHOUT AN ADULT. <br />HOT WATER IMMERSION WHILE UNDER THE INFLUENCE OF <br />ALCOHOL, NARCOTICS, DRUGS, OR MEDICINES MAY LEAD TO <br />SERIOUS CONSEQUENCES AND IS NOT RECOMMENDED. <br />DO NOT USE ALONE. <br />LONG EXPOSURE MAY RESULT IN HYPOTHERMIA, NAUSEA, <br />DIZZINESS, OR FAINTING. <br />WARNING! <br />NO DIVING <br />SHALLOW WATER INJURIES MAY RESULT <br />6'-3" <br />DECK LEVEL <br />4' <br />- <br />0 <br />" <br />NOTE: DETAIL IS FOR COORDINATION ONLY <br />FINAL DESIGN & LOCATION PER LANDSCAPE PLANS <br />NOTE: MOUNTING PER GENERAL CONTRACTOR PLACE SAFETY EQUIPMENT IN A VIEWABLE AND EASILY <br />ACCESSIBLE LOCATION ON THE DECK <br />1. SAFETY HOOK & CLEANING BRUSH <br />2. THROW RING & ROPE <br />3. TUBE STEEL SUPPORT STRUCTURE - FINISH PER ARCHITECT <br />4. WELDED METAL HOOKS <br />5. SUPPORT FOOTING FOR STRUCTURE <br />6. DECK & FINISH PER LANDSCAPE PLANS <br />4' <br />- <br />0 <br />" <br />2' <br />- <br />6 <br />" <br />SEE NOTE: #3 <br />SEE NOTE: #5 <br />SEE NOTE: #6 <br />SEE NOTE: #4 <br />SEE NOTE: #1 <br />SEE NOTE: #2 <br />POOL EQUIPMENT FILTER WITH WATER <br />(MAXIMUM WEIGHT = 1050 LBS) <br />INSTALLED PER MANUFACTURES <br />INSTRUCTIONS <br />6" MINIMUM THICKNESS <br />HOUSE KEEPING PAD <br />24" MINIMUM SPACING <br />4' <br />3 <br />" <br /> <br />M <br />A <br />X <br />I <br />M <br />U <br />M <br /> <br />T <br />A <br />N <br />K <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />FOUR (4) SIMPSON STRONG BOLD 38" DIA WEDGE <br />ANCHORS OR EQUAL. 3 78" EMBEDMENT INTO <br />STRUCTURALLY SOUND CONCRETE 1/4” X 1-3/4” S.S. TAPCONBOLT & WASHER (FIELD <br />SUPPLIED)NOTE: USE HOLE CLOSEST TO UNIT <br />WITH WASHER OVERLAPPING EDGE OF HEATER <br />STAINLESS STEEL ANCHOR BOLTS <br />POOL PIPE SIZE AND SPEC <br />PER PLUMBING PLAN <br />STAINLESS STEEL PIPE CLAMPS <br />GALVANIZED STEEL UNI-STRUT <br />PVC SLEEVE ALL CHEMICAL <br />TUBING AS NEEDED <br />38" CHEMICAL TUBING <br />NOTE: <br />1.PIPING & CHEMICAL TUBING <br />COMPONENTS SHALL BE <br />SEISMICALLY BRACED. <br />2.PIPING & TUBING SHALL BE <br />IDENTIFIED TO INDICATE THE <br />MATERIAL CONVEYED. <br />SEE NOTE #3 <br />SEE NOTE: #1 <br />7' <br /> <br />+ <br />/ <br />- <br /> <br />C <br />O <br />O <br />R <br />D <br />I <br />N <br />A <br />T <br />E <br />NOTE: MOUNTING PER GENERAL CONTRACTOR PLACE <br />SIGNS IN A VIEWABLE AND EASILY ACCESSIBLE <br />LOCATION ON THE DECK <br />1.WEATHER PROOF SIGNS PER HEALTH CODE <br />2.ARCHITECTURAL WALL - FINISH PER ARCHITECT <br />3.WALL ANCHORS - PER WALL TYPE <br />4.DECK & FINISH PER LANDSCAPE PLANS <br />SEE NOTE: #1 <br />SEE NOTE: #2 <br />SEE NOTE #4 <br />SEE NOTE: #4 <br />LINE OF SITE CONCRETE EXPANSION ANCHOR 14" X <br />2-3/8" EMBEDMENT IN CONCRETE (4) <br />LOCATIONS PER SUPPORT - COORDINATE <br />PENETRATION WITH WATER-PROOFING <br />6" <br />278" <br />CHEMICAL NOTES: <br />CLOSE CONTAINERS PROPERLY; <br />COVER OPENED OR DAMAGED PACKAGING; <br />STORE CHEMICALS AWAY FROM DOORS AND WINDOWS; ENSURETHAT THERE ARE NO ROOF LEAKS, OPEN OR BROKEN WINDOWS, ORLEAKS FROM WATER PIPES, HOSES, OR THE SPRINKLER SYSTEM; <br />ENSURE THAT FLOORS ARE SLOPED TO KEEP WATERDRAINED AWAY; <br />STORE CHEMICALS ON SHELVES OR PALLETS TO KEEPCONTAINERS OFF THE FLOOR; <br />USE WATERPROOF COVERS ON PACKAGING; <br />EXERCISE PARTICULAR CAUTION TO PREVENT WATERCONTACT WITH STORED CHEMICALS ANY TIME WATER IS USED FORCLEANUP OF FLOOR AREAS NEAR STORED PACKAGES; AND ENSURETHAT WATER WILL NOT BACK UP FROM FAULTY ORCLOGGED FLOOR DRAINS. <br />WARNING: WEAR RUBBER GLOVES AND SAFETY GLASSES WHENCLEANING FILTER SYSTEM. <br />SEPARATE INCOMPATIBLE SUBSTANCES; AVOID STORINGCONTAINERS OF LIQUIDS ABOVE CONTAINERS OF OTHERINCOMPATIBLE SUBSTANCES; <br />DO NOT MIX OLD CHEMICALS WITH FRESH CHEMICAL,EVEN IF THEY ARE THE SAME TYPE; <br />CONSIDER SEPARATE, DESIGNATED TOOLS FOR EACHCHEMICAL. HANDLE ONLY ONE CHEMICAL AT A TIMEAND MAKE SURE THAT TOOLS USED WITH ONE SUBSTANCE ARE NOTUSED WITH ANOTHER UNLESS ALL RESIDUES ARE REMOVED; <br />USE SEPARATE, DESIGNATED CONTAINERS FOR CLEANUP OFSPILLED MATERIALS TO AVOID INADVERTENT MIXING OF SPILLEDSUBSTANCES. CONSULT YOUR LOCAL HAZARDOUS WASTEDISPOSAL FACILITY FOR MORE DETAILED INFORMATION ON PROPERWASTE DISPOSAL; <br />MAKE CHEMICAL STORAGE AREA HOUSEKEEPING APRIORITY. DON’T ALLOW RAGS, TRASH, DEBRIS, OR OTHERMATERIALS TO CLUTTER HAZARDOUS MATERIAL STORAGE AREA <br />KEEP COMBUSTIBLE AND FLAMMABLESUBSTANCES AWAY. <br />CHEMICAL CABINETS SHELL MEET THE FOLLOWING: <br />NFPA REQUIREMENTS <br />OSHA REQUIREMENTS <br />FM APPROVED <br />LOCKABLE <br />CORROSION RESISTANT <br />SIGHT GLASS <br />DISCHARGE TO <br />BACKWASH RISER <br />FL <br />O <br />W <br />SAND FILTER <br />BACKWASH VALVE <br />Scale: NTS <br />PUMP VIBRATION ISOLATORS1 <br />Scale: NTS <br />CHEMICALS LABELS & SAFETY EQUIPMENT10 <br />CHEMICAL ROOM SIGNS & SAFETY EQUIPMENT <br />POOL CHEMICAL SIGNS; PRODUCT OF COMPLIANCY SIGNS: <br />- DANGER - AUTHORIZED PERSONNEL ONLY - #CUSTOM <br />- DANGER - HAZARDOUS POOL CHEMICALS - #ODE-7756 <br />- 704 SIGN - SODIUM HYPOCHLORITE (NaOCl) W/ CAS# - 7681-52-9 <br />- 704 SIGN - MURIATIC ACID ONLY (HCL) W/ CAS# - 7647-01-0 <br />SAFETY EQUIPMENT <br />- RESPIRATOR MASK: U-LINE, 3M HALF-FACE MASK - #H-1081 <br />- SAFETY GLASSES: OTG, CLEAR - #S-17940 <br />- NEOPRENE CHEMICAL RESISTANT APRON: U-LINE - #S-18815 <br />- NEOPRENE CHEMICAL RESISTANT GLOVES: ULINE - #S-11434 <br />Scale: NTS <br />EYEWASH STATION (BY OTHERS)12 DETAIL IS FOR (COORDINATION ONLY)Scale: 3/4"= 1 FT. <br />POOL & SPA SIGNS (SCHEMATIC)9 <br />SIGNAGE NOTES: <br />1.18" THICK PAINTED ALUMINUM BACKER PANEL. <br />2.SILKSCREENED COPY/GRAPHICS WITH SATIN CLEAR COAT. <br />3.14" THICK PAINTED ALUMINUM FACE PANEL WITH SILKSCREENED COPY/GRAPHICS. ATTACH TO 18" THICK PAINTED <br />ALUMINUM BACKER PANEL USING 'VHB' TAPE AND SILICONE ADHESIVE. <br />4. 2" WIDE x 12" THICK PAINTED ALUMINUM SIGN FRAME ADHERED TO 18" THICK PAINTED ALUMINUM BACKER USING <br />'LORDS' ADHESIVE AS REQUIRED. VERTICAL SECTIONS OF FRAME TO BE RECTANGULAR TUBE. FILL AND SAND <br />SEAM ALONG EDGE AND FACE PRIOR TO PAINTING. <br />NOTES: <br />1.COORDINATE SIGNAGE PLACEMENT AND COLOR SCHEME WITH ARCHITECT/OWNER PRIOR TO INSTALLATION. <br />2.CONTRACTOR TO PROVIDE SHOP DRAWINGS OF PROPOSED SIGNAGE FOR REVIEW. <br />REQUIRED SIGNAGE: <br />1.ALL SIGNS SHALL HAVE CLEARLY LEGIBLE LETTERS OR NUMBERS NOT LESS THAN 4 INCHES HIGH, UNLESS <br />OTHERWISE NOTED; AFFIXED TO A WALL, POLE, GATE, OR SIMILAR PERMANENT STRUCTURE IN A LOCATION <br />VISIBLE TO ALL POOL USERS. <br />1.A.POOL USER CAPACITY SIGN: A SIGN SHALL INDICATE THE MAXIMUM NUMBER OF POOL USERS PERMITTED <br />FOR EACH POOL. <br />1.B.NO DIVING SIGN: SIGNS SHALL BE POSTED IN CONSPICUOUS PLACES AND SHALL STATE 'NO DIVING' AT <br />POOLS WITH A MAXIMUM WATER DEPTH OF 6 FEET OR LESS. <br />1.C.NO LIFEGUARD SIGN: WHERE NO LIFEGUARD SERVICE IS PROVIDED, A WARNING SIGN SHALL BE POSTED <br />STATING, "WARNING: NO LIFEGUARD ON DUTY." THE SIGN ALSO SHALL STATE IN LETTERS AT LEAST 1 INCH <br />HIGH, "CHILDREN UNDER THE AGE OF 14 SHALL NOT USE POOL WITHOUT A PARENT OR ADULT GUARDIAN IN <br />ATTENDANCE," <br />1.D.ARTIFICIAL RESPIRATION AND CPR SIGN: AN ILLUSTRATED DIAGRAM WITH TEXT AT LEAST 1/4 INCH HIGH OF <br />ARTIFICIAL RESPIRATION AND CPR PROCEDURES SHALL BE POSTED. <br />1.E.EMERGENCY SIGN: THE EMERGENCY TELEPHONE NUMBER 911, THE NUMBER OF THE NEAREST EMERGENCY <br />SERVICES AND THE NAME AND STREET ADDRESS OF THE POOL FACILITY SHALL BE POSTED. <br />1.F.WARNING SIGN FOR A SPA POOL: A WARNING SIGN FOR THE SPA POOLS SHALL BE POSTED STATING <br />"CAUTION" AND SHALL INCLUDE THE FOLLOWING LANGUAGE IN LETTERS AT LEAST 1 INCH HIGH: <br />1.F.1.ELDERLY PERSONS, PREGNANT WOMEN, INFANT, AND THOSE WITH HEALTH CONDITIONS REQUIRING <br />MEDICAL CARE SHOULD CONSULT WITH A PHYSICIAN BEFORE ENTERING THE SPA. <br />1.F.2.UNSUPERVISED USE BY CHILDREN UNDER THE AGE OF 14 IS PROHIBITED. <br />1.F.3.HOT WATER IMMERSION WHILE UNDER THE INFLUENCE OF ALCOHOL, NARCOTICS, DRUGS, OR <br />MEDICINES MAY LEAD TO SERIOUS CONSEQUENCES AND IS NOT RECOMMENDED. <br />1.F.4.DO NOT USE ALONE. <br />1.F.5.LONG EXPOSURE MAY RESULT IN HYPERTHERMIA, NAUSEA, DIZZINESS, OR FAINTING. <br />1.G.EMERGENCY SHUT OFF: IN LETTERS AT LEAST ONE INCH HIGH A SIGN SHALL BE POSTED AT THE SPA <br />EMERGENCY SHUT OFF SWITCH STATING "EMERGENCY SHUT OFF SWITCH". <br />1.H.NO USE AFTER DARK: WHERE POOLS WERE CONSTRUCTED FOR WHICH LIGHTING WAS NOT REQUIRED A <br />SIGN SHALL BE POSTED AT EACH POOL ENTRANCE ON THE OUTSIDE OF THE GATE(S) STATING, "NO USE OF <br />POOL ALLOWED AFTER DARK". <br />1.I.KEEP CLOSED: A SIGN SHALL BE POSTED ON THE EXTERIOR SIDE OF GATES AND DOORS LEADING INTO THE <br />POOL ENCLOSURE AREA STATING, "KEEP CLOSED". <br />1.J.DIARRHEA: A SIGN IN LETTERS AT LEAST ONE INCH HIGH AND IN A LANGUAGE OR DIAGRAM THAT IS <br />CLEARLY STATED SHALL BE POSTED AT THE ENTRANCE AREA OF A PUBLIC POOL WHICH STATES THAT <br />PERSONS HAVING CURRENTLY ACTIVE DIARRHEA OR WHO HAVE HAD ACTIVE DIARRHEA WITHIN THE <br />PREVIOUS 14 DAYS SHALL NOT BE ALLOWED TO ENTER THE POOL WATER. <br />1.K.FLOW SIGNAGE AND LABELS. <br />1.L.THE DIRECTION OF FLOW FOR THE RECIRCULATION EQUIPMENT SHALL BE LABELED CLEARLY WITH <br />DIRECTIONAL SYMBOLS SUCH AS ARROWS ON ALL PIPING IN THE EQUIPMENT AREA. <br />1.M.WHERE THE RECIRCULATION EQUIPMENT FOR MORE THAN ONE POOL IS LOCATED ON SITE, THE EQUIPMENT <br />SHALL BE MARKED AS TO WHICH POOL THE SYSTEM SERVICES. <br />1.N.VALVES AND PLUMBING LINES SHALL BE LABELED CLEARLY WITH THE SOURCE OR DESTINATION <br />DESCRIPTIONS. <br />POOL SIGNS <br />SPA SIGNS <br />Scale: 1/2"=1' <br />DECK LEVEL SAFETY EQUIPMENT5 <br />Scale: NTS <br />FILTER MOUNTING ANCHORS2 Scale: NTS <br />HEATER ANCHORS (SECTION)3 Scale: NTS <br />POOL PIPE MOUNTING (SCHEMATIC)4 <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />BI <br />M <br /> <br />3 <br />6 <br />0 <br />: <br />/ <br />/ <br />0 <br />0 <br />7 <br />. <br />3 <br />7 <br />5 <br />7 <br />. <br />0 <br />0 <br />0 <br /> <br />- <br /> <br />C <br />a <br />r <br />i <br />b <br />o <br />u <br /> <br />I <br />n <br />d <br />u <br />s <br />t <br />r <br />i <br />e <br />s <br /> <br />- <br /> <br />3 <br />r <br />d <br /> <br />& <br /> <br />B <br />r <br />o <br />a <br />d <br />w <br />a <br />y <br />/ <br />3 <br />R <br />D <br />- <br />B <br />_ <br />A <br />R <br />C <br />H <br />_ <br />W <br />E <br />S <br />T <br />_ <br />R <br />2 <br />0 <br />. <br />r <br />v <br />t <br />07.3757.000 <br />3rd & Broadway <br />301 N. Broadway, Santa Ana, CA <br />09/21/2021 Issue for Plan Check <br />A 12/10/2021 Reissue for Plan Check <br />B 07/11/2022 Reissue for Plan Check <br />C 06/17/2024 REVISION TO PERMIT <br />R1-SP-504 <br />POOL & SPA DETAILS <br />Scale: 1/2"=1' <br />DECK LEVEL SAFETY SIGN (LOCATION)6 NOTE: DETAIL IS FOR COORDINATION ONLY <br />FINAL DESIGN & LOCATION PER LANDSCAPE PLANS <br />Scale: 3"= 1 FT. <br />EQUIPMENT RACK SUPPORT ANCHOR7 <br />Scale: NTS <br />CHEMICAL STORAGE CABINET11 <br />NOTE: DETAIL IS FOR COORDINATION ONLY <br />FINAL DESIGN & LOCATION PER LANDSCAPE PLANS <br />Scale: 1"= 1 FT. <br />FILTER & ANCHOR (SECTION)8 <br />Jun 04, 2024 <br />1/7/25