Laserfiche WebLink
2 <br />2 1 <br />- <br />2 NFPA 704 SIGNAGE - SEDG ENERGY BANK BESS <br />Scale NTS <br />15" <br />15" <br />6" <br />7-1/2"7-1/2" <br />LABEL LOCATION: <br />SIGNS SHOULD BE PLACED <br />WHERE THEY ARE EASILY VISIBLE <br />IN CASE OF AN EMERGENCY, <br />SUCH AS ON EXTERIOR WALLS OF <br />BUILDINGS, ENTRANCES TO <br />ROOMS OR AREAS, AND <br />PRINCIPAL ACCESS POINTS TO <br />EXTERIOR STORAGE AREAS. <br />1 ESS AC DISCONNECT <br />Scale NTS <br />LABEL LOCATION: <br />ON OR NEAR THE ESS DISCONNECTING MEANS I.E <br />INVERTERS FOR DC-COUPLED ESS <br />ENERGY STORAGE SYSTEM <br />AC DISCONNECT <br />NOTES AND SPECIFICATIONS: <br />·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE <br />110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF <br />REQUESTED BY THE LOCAL AHJ. <br />·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE <br />WORDS, COLORS AND SYMBOLS. <br />·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD <br />AND SHALL NOT BE HAND WRITTEN. <br />·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT <br />INVOLVED. <br />·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS <br />AND LABELS, UNLESS OTHERWISE SPECIFIED. <br />·DO NOT COVER EXISTING MANUFACTURER LABELS. <br />ENERGY STORAGE SYSTEM DISCONNECT <br />ARC FLASH AND SHOCK HAZARD <br />WARNING! <br />APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT <br />REFER TO NFPA 70 E. <br />LABEL LOCATION: <br />ESS AC DISCONNECT(S), AC <br />COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): NEC 2020 706.15(C)(4) <br />3 1/2" <br />5" <br />NOMINAL ESS AC VOLTAGE: <br />MAXIMUM ESS DC VOLTAGE: <br />AVAILABLE FAULT CURRENT <br />DERIVED FROM THE ESS: <br />DATE CALCULATION PREFORMED: <br />240 VAC <br />450 VDC <br />#### A <br />4/18/25 <br />3 POI-1 ESS ARC FLASH AND SHOCK HAZARD <br />Scale NTS <br />C:\USERS\THADDEUS.STEERMAN\DESKTOP\WORKING PROJECTS\2329 - TOWNSEND & RAITT II\7 VC - AHJ COMMENTS 3\2329_TOWNSEND&RAITTII_CAD_VC\TOWNSEND & RAITT II.DWG <br />WARNING LABELS <br />CONTRACTOR: <br />ENGINEERING APPROVAL: <br />600 CALIFORNIA ST #1800, SAN <br />FRANCISCO, CA 94104 <br />CA CL #750184 <br />UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN <br />PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT <br />LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. <br />TOWNSEND & RAITT II <br />834 S RAITT ST, SANTA ANA, <br />CA 92704, USA <br />APN:109-611-12 <br />DEVELOPER: <br />C&C DEVELOPMENT <br />DESCRIPTION DATE REV <br />0ORIGINAL05/06/2025 <br />CBESS ATTACHMENT DETAILS 10/27/2025 <br />PROJECT DETAILS: <br />PV SYSTEM: <br />·18.86 kW DC <br />·15.2 kW AC <br />·17.57 CEC AC <br />ENERGY STORAGE: <br />·15.2 kW AC <br />·58.2 kWH <br />E801 <br />SHEET SIZE: <br />REVISION: <br />SHEET TITLE: <br />36" X 24" (ARCH D) <br />DESIGNER: <br />FINS_VIS <br />C <br />PROJECT NUMBER: <br /> PROP-002329 <br />ADOWNSIZE & AHJ COMMENTS 08/08/25 <br />BSYSTEM DOWNSIZE 09/22/25 <br />#ESTAMP