Laserfiche WebLink
C:\USERS\THADDEUS.STEERMAN\DESKTOP\WORKING PROJECTS\2329 - TOWNSEND & RAITT II\7 VC - AHJ COMMENTS 3\2329_TOWNSEND&RAITTII_CAD_VC\TOWNSEND & RAITT II.DWG <br />SITE PLACARDS <br />CONTRACTOR: <br />ENGINEERING APPROVAL: <br />600 CALIFORNIA ST #1800, SAN <br />FRANCISCO, CA 94104 <br />CA CL #750184 <br />UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN <br />PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT <br />LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. <br />TOWNSEND & RAITT II <br />834 S RAITT ST, SANTA ANA, <br />CA 92704, USA <br />APN:109-611-12 <br />DEVELOPER: <br />C&C DEVELOPMENT <br />DESCRIPTION DATE REV <br />0ORIGINAL05/06/2025 <br />CBESS ATTACHMENT DETAILS 10/27/2025 <br />PROJECT DETAILS: <br />PV SYSTEM: <br />·18.86 kW DC <br />·15.2 kW AC <br />·17.57 CEC AC <br />ENERGY STORAGE: <br />·15.2 kW AC <br />·58.2 kWH <br />E810 <br />SHEET SIZE: <br />REVISION: <br />SHEET TITLE: <br />36" X 24" (ARCH D) <br />DESIGNER: <br />FINS_VIS <br />C <br />PROJECT NUMBER: <br /> PROP-002329 <br />ADOWNSIZE & AHJ COMMENTS 08/08/25 <br />BSYSTEM DOWNSIZE 09/22/25 <br />C:\USERS\THADDEUS.STEERMAN\DESKTOP\WORKING PROJECTS\2329 - TOWNSEND & RAITT II\7 VC - AHJ COMMENTS 3\2329_TOWNSEND&RAITTII_CAD_VC\TOWNSEND & RAITT II.DWG <br />#ESTAMP <br />POI-1 <br />DIRECTORY <br />PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF <br />THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC <br />SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION <br />[NEC 690.56(B)] <br />WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A <br />DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV <br />SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND <br />AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF <br />ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. <br />[NEC 690.4(D)] <br />MULTIPLE SOURCES OF POWER <br />CAUTION: <br />834 S RAITT ST, SANTA ANA, CA 92704, USA <br />INVERTER AND BATTERY <br />AC DISCONNECT (EXT.) <br />BESS LOCATION (EXT.) <br />AC DISCONNECT (EXT.) <br />AC DISCONNECT (EXT.) <br />MAIN SERVICE <br />DISCONNECTS (EXT.) <br />PV ARRAY <br />BLDG 834 <br />NGOM <br />M <br />SCE LINE SIDE <br />DISCONNECT <br />GENERATION LOAD <br />SIDE DISCONNECTUTILITY <br />DISTRIBUTION <br />SYSTEM <br />1 <br />3 <br />8 <br />2 <br />7 <br />9 <br />PV <br />GENERATION <br />FACILITY <br />46 <br />5 <br />SCE LINE SIDE DISCONNECT <br />LABEL LOCATION: <br />LINE SIDE DISCONNECT <br />LABEL LOCATION: <br />LOAD SIDE DISCONNECT <br />LABEL LOCATION: <br />IF PANEL MODIFICATIONS ARE MADE <br />APPROPRIATE PLACARDS MUST BE INSTALLED <br />LABELING THE SECTIONS. <br />1 <br />2 <br />7 <br />LABEL LOCATION: <br />THE WIRING SEQUENCE OF <br />FACTORY-INSTALLED TEST-BYPASS BLOCKS, <br />FROM LEFT TO RIGHT, IS LINE-LOAD, <br />LINE-LOAD, LINE-LOAD. THIS WIRING <br />SEQUENCE SHALL BE PERMANENTLY <br />LABELED IN 3/4-INCH BLOCK LETTERS BELOW <br />THE TEST-BYPASS TERMINALS. LINE AND <br />LOAD CONDUCTORS SHALL BE CONNECTED <br />ONLY TO TEST-BYPASS BLOCK TERMINALS <br />DESIGNED AS LINE AND LOAD, <br />RESPECTIVELY. <br />3 <br />LABEL LOCATION: <br />ON THE METER PANEL OR ADJACENT TO THE <br />METER SOCKET. ACCEPTABLE METHODS FOR <br />LABELING CUSTOMER NGO METERING <br />SECTIONS OR PANEL(S) SHALL BE EITHER BY <br />PERMANENTLY ATTACHED <br />MACHINE-ENGRAVED LAMINATED PHENOLIC <br />(OR EQUAL) TAGS OR BY PERMANENT <br />STENCILED PAINT LETTERING. TEXT HEIGHT <br />MIN. 1/4". <br />8 <br />SCE METERING PLACARDS <br />NTS <br />SOLAR INTERCONNECTION <br />TERMINATION SECTION <br />LINE LOAD <br />SCE UTILITY TERMINATION <br />SECTION <br />DISCONNECT 1 OF 2 <br />GENERATION LOAD SIDE <br />DISCONNECT <br />DISCONNECT 2 OF 2 <br />NET GENERATION OUTPUT <br />METERING <br />NOTE: SCE REQUIRES A SAFETY-SOCKET BOX WITH FACTORY-INSTALLED <br />TEST-BYPASS BLOCKS FOR NON-INSTRUMENT RATED (SELF-CONTAINED) <br />NGO METERING. FOR SWITCHBOARDS/SWITCHGEAR, THE CUSTOMER MUST <br />LABEL THE GENERATOR OUTPUT BUS/CABLE DIRECTION (E.G., "TOP <br />GENERATOR FED"). IF NGO AND PCC METERING ARE SEPARATED BY OVER <br />100 FEET OR ON DIFFERENT LEVELS, A PERMANENT SIGN AT THE PCC METER <br />MUST INDICATE THE NGO METER'S LOCATION. <br />CURRENT FLOW <br />LABEL LOCATION: <br />FOR INSTRUMENT TRANSFORMER RATED CT <br />NGOM PANELS, THE ARROW POINTING <br />TOWARDS THE UTILITY SIDE DISCONNECT <br />SHALL BE INSTALLED ON THE INSIDE SIDE <br />WALL OF PANEL OR ON THE OUTSIDE FRONT <br />OF NGOM PANEL. <br />5 <br />SCE LINE SIDE PV LOAD SIDE <br />LABEL LOCATION: <br />PULL SECTIONS <br />4 <br /> GRID GENERATION <br />LABEL LOCATION: <br />GRID AND GENERATION CONDUCTORS <br />6 <br />LABEL LOCATION: <br />PLACE A UNIQUE ADDRESS PLACARD ON THE <br />NGOM THAT MATCHES THE AHJ PERMIT AND <br />THE SCE SERVICE REQUEST ADDRESS. <br />9 <br />123 MAIN ST. SOMAH1 <br />NOTE: IF INTERCONNECTION IS MADE WITHIN A NEW TERMINATION <br />CAN, THE "SOLAR INTERCONNECTION TERMINATION SECTION" <br />PLACARD IS REQUIRED