Laserfiche WebLink
CITY OF SANTA ANA <br />Ln <br />U <br />0 <br />W <br />0 <br />z <br />Q <br />w <br />z <br />w <br />0 <br />N <br />0 <br />0 <br />0 <br />N <br />z <br />Q <br />J <br />a- <br />z <br />0 <br />z <br />0 <br />0 <br />J <br />m <br />i <br />w <br />w <br />CD <br />z <br />D <br />0 <br />0 <br />N <br />N <br />0 <br />N <br />0 <br />Q <br />00 <br />w <br />0 <br />J <br />n <br />IIB-505.10.3 BOTTOM EXTENSION AT STAIRS. AT THE BOTTOM <br />OF A STAIR FLIGHT, HANDRA I L5 SHALL EXTEND AT THE <br />SLOPE OF THE STAIR FL 16HT FOR A HORIZONTAL DISTANCE <br />EQUAL TO ONE TREAD DEPTH BEYOND THE LAST RISER <br />NOSING. THE HORIZONTAL EXTENSION OF A HANDRAIL SHALL <br />BE 12 INCHES (305 MM) LONG MINI MUM AND A HEIGHT EQUAL <br />TO THAT OF THE SLOPING PORTION OF THE HANDRAIL AS <br />MEASURED ABOVE THE STAIR NOSING. EXTENSION SHALL <br />RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR <br />SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT <br />STAIR FLIGHT. <br />PLUMB I NG ELEMENT5 AND FAG I L I T I E5 <br />DIVISION 6 <br />II5-603 TOILET AND BATHING ROOMS <br />IIB-603.2 CLEARANCES. CLEARANCES SHALL COMPLY WITH <br />SECTION IIB-603.2. <br />II6-603.2.1 TURNING SPACE. TURNING SPACE COMPLYING WITH <br />SECTION II5-304 SHALL BE PROVIDED WITHIN THE ROOM. <br />15-603.2.2 OVERLAP. REQUIRED CLEAR FLOOR SPACES, <br />CLEARANCE AT FIXTURES, AND TURNING SPACE SHALL BE <br />PERMITTED TO OVERLAP. <br />IIB-603.2.3 DOOR 5WIN6. DOORS SHALL NOT SWING INTO THE <br />CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY <br />FIXTURE. DOORS TO AGGE551BLE WATER CLOSET <br />GOMPARTMENT5 SHALL BE PERMITTED TO ENCROACH INTO <br />THE TURNING SPACE WITHOUT LIMITATION. OTHER THAN DOORS <br />TO ACCESSIBLE WATER CLOSET COMPARTMENTS, A DOOR, IN <br />ANY POSITION, SHALL BE PERMITTED TO ENCROACH INTO THE <br />TURNING SPACE BY 12 INCHES (305 MM) MAXIMUM. <br />II5-603.3 MIRRORS. MIRRORS LOCATED ABOVE LAVATORIES <br />OR GOUNTERTOP5 SHALL BE INSTALLED WITH THE BOTTOM <br />EDGE OF THE REFLECTING SURFACE 40 INCHES (1016 MM) <br />MAXIMUM ABOVE THE FIN15H FLOOR OR GROUND. MIRRORS <br />NOT LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL <br />BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING <br />SURFACE 35 INCHES (881 MM) MAXIMUM ABOVE THE F I N 15H <br />FLOOR OR GROUND. <br />II5-603.5 ACCESSORIES. WHERE TOWEL OR SANITARY NAPKIN <br />DISPENSERS, WASTE REGEPTAGLE5, OR OTHER AGGE55ORIE5 <br />ARE PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF <br />EACH TYPE SHALL BE LOCATED ON AN ACCESSIBLE ROUTE. <br />ALL OPERABLE PARTS, I NGLUD I N6 C01 N SLOTS, SHALL BE 40 <br />INCHES (1016 MM) MAXIMUM ABOVE THE FINISH FLOOR. <br />II6-604 WATER CLOSETS AND TOILET COMPARTMENTS <br />II5-604.2 LOCATION. THE WATER CLOSET SHALL BE <br />POSITIONED WITH A WALL OR PARTITION TO THE REAR AND <br />TO ONE SIDE. THE GENTERLINE OF THE WATER CLOSET SHALL <br />BE 77 INCHES (432 MY) MINIMUM TO 18 INCHES (451 MY) <br />MAXIMUM FROM THE 51DE WALL OR PARTITION, EXCEPT THAT <br />THE WATER CLOSET SHALL BE 11 INCHES (432 MM) MINIMUM <br />AND 11 INCHES (483 MM) MAXIMUM FROM THE 51DE WALL OR <br />PARTITION IN THE AMBULATORY ACCESSIBLE TOILET <br />GOMPART MENT SPECIFIED IN SECTION 115-604.8.2. WATER <br />CLOSETS SHALL BE ARRANGED FOR A LEFT-HAND OR <br />R16HT-HAND APPROACH. <br />II6-604.3 CLEARANCE. CLEARANCES AROUND WATER <br />CLOSETS AND IN TOILET COMPARTMENTS SHALL COMPLY <br />WITH SECTION II5-604.3. <br />II5-604.3.1 SIZE. GLEARANGE AROUND A WATER CLOSET <br />SHALL BE 60 INCHES (1524 MM) MINIMUM MEASURED <br />PERPEND I GUAAR FROM THE SIDE WALL AND 56 INCHES (1422 <br />MM) MINIMUM MEASURED PERPENDICULAR FROM THE REAR <br />WALL. A MINIMUM 60 INCHES (1524 MM) WIDE AND 48 INCHES <br />(12lq MM) DEEP MANEUVERING SPACE SHALL BE PROVIDED IN <br />FRONT OF THE WATER CLOSET. <br />EXCEPTION: IN RESIDENTIAL DWELLING UNITS COMPLYING WITH <br />SECTION II5-233.3.1.1, MANEUVERING SPACE IN FRONT OF THE <br />WATER CLOSET SHALL BE A MINIMUM 60 INCHES (1524 MM) <br />WIDE AND 36 INCHES (q 14 MM) DEEP. <br />II5-604.3.2 OVERLAP. THE REQUIRED CLEARANCE AROUND <br />THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE <br />WATER CLOSET, A550G I ATED GRAB BARS, DISPENSERS, <br />SANITARY NAPKIN DISPOSAL UNITS, GOAT HOOK5, SHELVES, <br />AGGE551 BLE ROUTES, CLEAR FLOOR SPACE AND <br />CLEARANCES REQUIRED AT OTHER FIXTURES, AND THE <br />TURNING SPACE. NO OTHER FIXTURES OR 055TRUGTION5 <br />SHALL BE LOCATED WITHIN THE REQUIRED WATER GL05ET <br />CLEARANCE. <br />IIB-604.4 SEATS. THE SEAT HE16HT OF A WATER CLOSET <br />ABOVE THE F I N I5H FLOOR SHALL BE 11 INCHES (432 MM) <br />MINIMUM AND H INCHES (483 MM) MAXIMUM MEASURED TO THE <br />TOP OF THE SEAT. SEATS SHALL NOT BE SPRUNG TO RETURN <br />TO A LIFTED POSITION. SEATS SHALL BE 2 INCHES (51 MM) <br />H16H MAXIMUM. <br />I5-604.5 GRAB BARS. GRAB BARS FOR WATER CLO5ET5 <br />SHALL GOM PLY WITH 5EGTION II5-601. GRAB BARS SHALL <br />BE PROVIDED ON THE SIDE WALL CLOSEST TO THE WATER <br />CLOSET AND ON THE REAR WALL. WHERE SEPARATE GRAB <br />5AR5 ARE REQUIRED ON ADJACENT WALLS AT A GOMMON <br />MOUNTING HEIGHT, AN L-SHAPED GRAB BAR MEETING THE <br />DIMEN51ONAL REQUIREMENTS OF 5EGTION5 115-604.5.1 AND <br />I5-604.5.2 SHALL BE PERMITTED. <br />II5-604.5.1 51DE WALL. THE 51DE WALL GRAB BAR SHALL BE <br />42 INCHES (1067 MM) LONG MINIMUM, LOCATED 12 INGHE5 (305 <br />MM) MAXIMUM FROM THE REAR WALL AND EXTENDING 54 <br />INCHES (1312 MM) MINIMUM FROM THE REAR WALL WITH THE <br />FRONT END P051TIONED 24 INCHES (610 MM) MINIMUM IN <br />FRONT OF THE WATER CLOSET. <br />IIB-604.5.2 REAR WALL. THE REAR WALL GRAB BAR SHALL <br />BE 36 INCHES (114 MM) LONG MINIMUM AND EXTEND FROM THE <br />GENTERLINE OF THE WATER CLOSET 12 INCHES (305 MM) <br />MINIMUM ON ONE SIDE AND 24 INCHES (610 MM) MINIMUM ON <br />THE OTHER SIDE. <br />II5=604.6 FLUSH GONTROL5. FLUSH GONTROLS SHALL BE <br />HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH <br />GONTROL5 SHALL COMPLY WITH SECTION IIB-30q EXGEPT <br />THEY SHALL BE LOCATED 44 INCHES (1115 MM) MAXIMUM <br />ABOVE THE FLOOR. FLUSH CONTROLS SHALL BE LOCATED ON <br />THE OPEN 51DE OF THE WATER CLOSET EXCEPT IN <br />AMBULATORY ACCESSIBLE COMPARTMENTS COMPLYING WITH <br />SECTION II5-604.8.2. I5-604.1 DISPENSERS AND DISPOSAL <br />UNITS. TOILET PAPER DISPENSERS AND 5AN I TARY NAPKIN <br />DISPOSAL UNITS SHALL COMPLY WITH SECTION 5-604.1. <br />COMBINATION ACCESSORY UNITS ARE NOT PERMITTED TO <br />ENCROACH INTO THE SPACE REQUIRED BY SECTION II5-601.3. <br />II6-604.1.1 DISPENSERS. TOILET PAPER DISPENSERS SHALL <br />COMPLY WITH SECTION II5-301.4 AND SHALL BE 7 INCHES <br />(778 MM) MINIMUM AND q INGHE5 (221 MM) MAXIMUM IN FRONT <br />OF THE WATER CLOSET MEASURED TO THE GENTERLINE OF <br />THE DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE <br />BELOW THE GRAB BAR, 11 INCHES (483 MM) MINIMUM ABOVE <br />THE FINISH FLOOR AND SHALL NOT BE LOCATED BEHIND <br />GRAB BARS. 015PEN5ER5 SHALL NOT BE OF A TYPE THAT <br />CONTROLS DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS <br />PAPER FLOW. <br />II5=604.7.2 DISPOSAL UNITS. SANITARY NAPKIN DISPOSAL <br />UNITS, IF PROVIDED, SHALL COMPLY WITH SECTION IIB-301.4 <br />AND SHALL BE WALL MOUNTED AND LOCATED ON THE <br />51DENALL BETWEEN THE REAR WALL OF THE TOILET AND THE <br />TOILET PAPER DISPENSER, ADJACENT TO THE TOILET PAPER <br />DISPENSER. THE DISPOSAL UNIT SHALL BE LOCATED BELOW <br />THE GRAB BAR WITH THE OPENING OF THE DISPOSAL UNIT I1 <br />INGHE5 MINIMUM (483 MM) ABOVE THE FINISH FLOOR. <br />B-604.8 TOILET GOMPARTMENT5. WHEELGHAIR ACCESSIBLE <br />TOILET COMPARTMENTS SHALL MEET THE REQUIREMENTS OF <br />SECTIONS IIB-604.8.1 AND IIB-604.5.3. COMPARTMENTS <br />CONTAINING MORE THAN ONE PLUMBING FIXTURE SHALL <br />COMPLY WITH SECTION 115-603. AMBULATORY ACCESSIBLE <br />GOMPARTMENT5 SHALL COMPLY WITH 5EGTION5 II5-604.5.2 <br />AND II5-604.8.3. <br />IIB-604.8.1 WHEELGHAIR AGGE55IBLE COMPARTMENTS. <br />WHEELGHAIR ACCESSIBLE COMPARTMENTS SHALL COMPLY <br />WITH SECTION IIB-604.8.1. <br />II6-604.5.1.1 SIZE. WHEELGHAIR ACCESSIBLE COMPARTMENTS <br />SHALL BE 60 INCHES (1524 MM) WIDE MINIMUM MEASURED <br />PERPENDICULAR TO THE 51DE WALL, AND 56 INCHES (1422 MM) <br />DEEP MINIMUM FOR WALL HUNG WATER CLOSETS AND 51 <br />INGHE5 (14g1 MM) DEEP MINIMUM FOR FLOOR MOUNTED WATER <br />CLOSETS MEASURED PERPENDICULAR TO THE REAR WALL. <br />WHEELGHAIR ACCESSIBLE COMPARTMENTS SHALL <br />ADDITIONALLY PROVIDE MANEUVERING SPACE COMPLYING <br />WITH SECTION IIBs604.8.1.I.I, II5-604.8.1.1.21 OR II5-604.8.1.1.3, <br />AS APPLICABLE. WHEELGHAIR ACCESSIBLE COMPARTMENTS <br />FOR GHILDREN5 USE SHALL BE 60 INGHE5 (1524 MM) WIDE <br />MINIMUM MEASURED PERPENDICULAR TO THE SIDE WALL, AND <br />51 INCHES (14gq MM)DEEP MINIMUM FOR WALL HUNG AND <br />FLOOR MOUNTED WATER CLOSETS MEASURED <br />PERPENDICULAR TO THE REAR WALL. <br />115-604.8. I.1.I MANEUVERING SPACE WITH N-5W I N61 N6 DOOR. <br />IN A WHEELGHAIR ACCESSIBLE COMPARTMENT WITH AN <br />IN-5WIN61N6 DOOR, A MINIMUM 60 INCHES (1524 MM) WIDE BY <br />36 INCHES (q14 MM) DEEP MANEUVERING SPACE SHALL BE <br />PROVIDED IN FRONT OF THE GLEARANGE REQUIRED IN <br />SECTION II8-604.8.1.1. SEE FIGURES IIB-604.8.1.1.2 (B) AND <br />IIB-604.8.I.1.3 (B). <br />II5-604.5.1.1.2 MANEUVERING SPACE WITH 51DE-OPENING <br />DOOR. IN A WHEELGHAIR AGCE551 BLE COMPARTMENT WITH A <br />DOOR LOCATED IN THE SIDE WALL OR PARTITION, EITHER <br />IN -SWINGING OR OUT -SWINGING, A MINIMUM 60 INGHE5 (1524 <br />MM) WIDE AND 60 INGHE5 (1524 MM) DEEP MANEUVERING <br />SPACE SHALL BE PROVIDED IN FRONT OF THE WATER <br />CLOSET. SEE FIGURE II5-604.8.1.1.2. <br />II5-604.8.1.1.3 MANEUVERING SPACE WITH END OPENING DOOR. <br />IN A WHEELGHAIR ACCESSIBLE COMPARTMENT WITH A DOOR <br />LOCATED IN THE FRONT WALL OR PARTITION (FAGIN6 THE <br />WATER CLOSET), EITHER N-5W I N61 N6 OR OUT-5W1 W N6, A <br />MINIMUM 60 INGHE5 (1524 MM) WIDE AND 48 INGHE5 (1211 MM) <br />DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT <br />OF THE WATER CLOSET. SEE FIGURE IIB-604.8.1.1.3. <br />IIB-604.8.1.2 DOORS. TOILET COMPARTMENT DOORS, <br />INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION <br />115-404 EXCEPT THAT IF THE APPROACH 15 FROM THE PUSH <br />SIDE OF THE COMPARTMENT DOOR, CLEARANCE BETWEEN THE <br />DOOR SIDE OF THE COMPARTMENT AND ANY OB5TRUGTION <br />SHALL BE 48 INCHES (121 1 MM) MINIMUM MEASURED <br />PERPENDICULAR TO THE COMPARTMENT DOOR IN ITS CLOSED <br />POSITION. DOORS SHALL BE LOCATED IN THE FRONT <br />PARTITION OR IN THE SIDE WALL OR PARTITION FARTHEST <br />FROM THE WATER CLOSET. WHERE LOCATED IN THE FRONT <br />PARTITION, THE DOOR OPENING SHALL BE 4 INCHES (102 MM) <br />MAXIMUM FROM THE 51DE WALL OR PARTITION FARTHEST <br />FROM THE WATER CLOSET. WHERE LOCATED IN THE 51DE <br />WALL OR PARTITION, THE DOOR OPENING SHALL BE 4 INCHES <br />(102 MM) MAXIMUM FROM THE FRONT PARTITION. THE DOOR <br />SHALL BE SELF-GL051N6. A DOOR PULL COMPLYING WITH <br />SECTION II5-404.2.1 SHALL BE PLACED ON BOTH SIDES OF <br />THE DOOR NEAR THE LATCH. DOORS SHALL NOT 5WIN6 INTO <br />THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR <br />ANY FIXTURE. DOORS MAY 5WIN6 INTO THAT PORTION OF <br />MANEUVERING SPACE WHIGH DOES NOT OVERLAP THE <br />CLEARANCE REQUIRED AT A WATER CLOSET. <br />5-604.8.1.3 APPROACH. COMPARTMENTS SHALL BE <br />ARRANGED FOR LEFT-HAND OR R16HT-HAND APPROACH TO <br />THE WATER CLOSET. <br />II5-604.8.1.4 TOE GLEARANGE. AT LEAST ONE 51DE PARTITION <br />SHALL PROVIDE A TOE CLEARANCE OF q INCHES (22q MM) <br />MINIMUM ABOVE THE FINISH FLOOR AND 6 INCHES (152 MM) <br />DEEP MINIMUM BEYOND THE COMPARTMENT- 51DE FACE OF <br />THE PARTITION, EXCLUSIVE OF PARTITION SUPPORT MEMBERS. <br />PARTITION GOMPONENT5 AT TOE CLEARANCES SHALL BE <br />SMOOTH WITHOUT SHARP EDGES OR ABRASIVE SURFACES. <br />COMPARTMENTS FOR GHILDREN5 USE SHALL PROVIDE A TOE <br />CLEARANCE OF 12 INCHES (305 MM) MINIMUM ABOVE THE <br />F I N I5H FLOOR. <br />EXCEPTION: TOE CLEARANCE AT THE 51DE PARTITION 15 NOT <br />REQUIRED IN A COMPARTMENT GREATER THAN 66 INCHES <br />(1616 MM) WIDE. <br />5-604.8.15 GRAB BARS. GRAB BARS SHALL COMPLY WITH <br />SECTION IIB-60q. A SIDE -WALL GRAB BAR GOMPLYIN6 WITH <br />SECTION IIB-604.5.1 SHALL BE PROVIDED AND SHALL BE <br />LOCATED ON THE WALL CLOSEST TO THE WATER CLOSET. IN <br />ADDITION, A REAR -WALL GRAB BAR COMPLYING WITH <br />SECTION IIB-604.5.2 SHALL BE PROVIDED. WHERE SEPARATE <br />GRAB BARS ARE REQUIRED ON ADJACENT WALLS AT A <br />COMMON MOUNTING HEIGHT, AN L-SHAPED GRAB BAR MEETING <br />THE D I MEN51 ONAL REQUIREMENTS OF SECTIONS 118-604.5.1 <br />AND IIB-604.5.2 SHALL BE PERMITTED. <br />II6-604.8.2 AMBULATORY ACCESSIBLE COMPARTMENTS. <br />AMBULATORY ACCESSIBLE COMPARTMENTS SHALL COMPLY <br />WITH SECTION II5-604.8.2. <br />I5-604.8.2.1 SIZE. AMBULATORY ACCESSIBLE GOMPARTMENTS <br />SHALL HAVE A DEPTH OF 60 INCHES fE1524 MM) MINI MUM <br />AND A WIDTH OF 35 INCHES f' 881 MM) MINIMUM AND 37 <br />INCHES (140 MM) MAXIMUM. <br />II6-604.8.2.2 DOORS. TOILET COMPARTMENT DOORS, <br />INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION <br />II6-404, EXCEPT THAT IF THE APPROACH 15 TO THE LATCH <br />SIDE OF THE COMPARTMENT DOOR, CLEARANCE BETWEEN THE <br />DOOR SIDE OF THE COMPARTMENT AND ANY 05STRUGTION <br />SHALL BE 44 INCHES (IIIS MM) MINIMUM. THE DOOR SHALL BE <br />SELF GL051N6. A DOOR PULL COMPLYING WITH SECTION I15- <br />404.2.1 SHALL BE PLACED ON BOTH SIDES OF THE DOOR <br />NEAR THE LATCH. TOILET COMPARTMENT DOORS SHALL NOT <br />SANG INTO THE MINIMUM REQUIRED COMPARTMENT AREA. <br />IS-604.5.2.3 GRAB BARS. GRAB BARS SHALL COMPLY WITH <br />SECTION II5-601. A SIDE -WALL GRAB BAR GOMPLYIN6 WITH <br />SECTION IIB-604.5.1 SHALL BE PROVIDED ON BOTH 51DE5 OF <br />THE COMPARTMENT. <br />115-604.8.3 COAT HOOKS AND SHELVES. GOAT HOOKS <br />SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES <br />SPECIFIED IN SECTION 115-308. SHELVES SHALL BE LOCATED <br />40 INCHES t 1016 MM) MINIMUM AND 48 INCHES (121q MM) <br />MAXIMUM ABOVE THE FINISH FLOOR. <br />II5-604.q WATER CLOSETS AND TOILET COMPARTMENTS FOR <br />GHILDREN'S USE. WATER GL05ET5 AND TOILET <br />COMPARTMENTS FOR GHILDREN'S USE SHALL COMPLY WITH <br />SECTION II5-604.1. WHEN THE EXCEPTION IN SECTION II5-604.1 <br />15 USED, THE 5U66E5TED DIMENSIONS OF TABLE II5-6041 <br />FOR A SINGLE AGE GROUP SHALL BE APPLIED CONSISTENTLY <br />TO THE INSTALLATION OF A WATER CLOSET AND ALL <br />A550GIATED GOMPONENT5. <br />I5-604.q.1 LOCATION. THE WATER CLOSET SHALL BE <br />LOCATED WITH A WALL OR PARTITION TO THE REAR AND TO <br />ONE SIDE. THE GENTERLINE OF THE WATER CLOSET SHALL BE <br />12 INCHES (305 MM) MINIMUM AND 18 INCHES T457 MM) <br />MAXIMUM FROM THE 51DE WALL OR PARTITION, EXCEPT THAT <br />THE WATER GL05ET SHALL BE 11 INGHE5 fE432 MM) MINIMUM <br />AND 11 INCHES t483 MM) MAXIMUM FROM THE 51DE WALL OR <br />PARTITION IN THE AMBULATORY AGGE5515LE TOILET <br />COMPARTMENT SPECIFIED IN SECTION 118-604.8.2. <br />COMPARTMENTS SHALL BE ARRANGED FOR LEFT-HAND OR <br />RIGHT-HAND APPROACH TO THE WATER CL05ET. <br />115-604.1.2 CLEARANCE. CLEARANCE AROUND A WATER <br />GL05ET SHALL COMPLY WITH SECTION IIB-604.3. <br />IIB-604.q.3 HEIGHT. THE HE16HT OF WATER CLOSETS SHALL <br />BE 11 INGHE5 (27q MM) MINIMUM AND 11 INCHES t432 MM) <br />MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS SHALL <br />NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. <br />II6-604.1.4 GRAB BARS. GRAB BARS FOR WATER CLOSETS <br />SHALL COMPLY WITH SECTION II5-604.5. <br />5-604.q.5 FLUSH CONTROLS. FLUSH GONTROLS SHALL BE <br />HAND OPERATED OR AUTOMATIC. HAND OPERATED HUSH <br />CONTROLS SHALL COMPLY WITH SEGTION5 IIB-30q.2 AND <br />15-301.4 AND SHALL BE INSTALLED 36 INGHE5 (114 MM) <br />MAXIMUM ABOVE THE FINISH FLOOR. FLUSH CONTROLS SHALL <br />BE LOCATED ON THE OPEN 51DE OF THE WATER CLOSET <br />EXCEPT IN AMBULATORY ACCESSIBLE COMPARTMENTS <br />COMPLYING WITH SECTION IIB-604.8.2. <br />IIB-604.q.6 DISPENSERS. TOILET PAPER D I5PEN5ER5 SHALL <br />COMPLY WITH 5EGTION II5-301.4 AND SHALL BE 7 INGHE5 (178 <br />MM) MINIMUM AND q INGHE5 (22q MM) MAXIMUM IN FRONT OF <br />THE WATER CLOSET MEASURED TO THE GENTERLINE OF THE <br />DISPENSER, THE OUTLET OF THE DISPENSER SHALL BE 14 <br />INCHES (356 MM) MINIMUM AND I 1 INCHES (483 MM) MAXIMUM <br />ABOVE THE F I N I5H FLOOR. THERE SHALL BE A CLEARANCE <br />OF 1 1/2" INCHES (35 MM) MINIMUM BELOW THE GRAB BAR. <br />DI5PEN5ER5 SHALL NOT BE OF A TYPE THAT CONTROLS <br />DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS PAPER <br />FLOW. <br />IIB-604.q.7 TOILET COMPARTMENTS. TOILET COMPARTMENTS <br />SHALL COMPLY WITH SECTION IIB-604.8. <br />II5-605 URINALS <br />116-605.2 HE16HT AND DEPTH. URINALS SHALL BE THE <br />STALL -TYPE OR THE WALL -HUNG TYPE WITH THE RIM 11 INCHES <br />(432 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. <br />URINALS SHALL BE 13 1/2" INCHES (343 MY) DEEP MINIMUM <br />MEASURED FROM THE OUTER FACE OF THE URINAL RIM TO <br />THE BACK OF THE FIXTURE. <br />II5-605.3 CLEAR FLOOR SPACE. A CLEAR FLOOR OR <br />GROUND SPACE COMPLYING WITH SECTION II5-305 <br />P051TIONED FOR FORWARD APPROACH SHALL BE PROVIDED. <br />IIB-605.4 FLUSH CONTROLS. FLUSH GONTROL5 SHALL BE <br />HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH <br />CONTROLS SHALL COMPLY WITH SECTION II5-301 EXCEPT <br />THAT THE FLUSH CONTROL SHALL BE MOUNTED AT A MAXIMUM <br />HEIGHT OF 44 INCHES (1 118 MM) ABOVE THE FIN 15H FLOOR. <br />II6-606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE <br />COMPLYING WITH SECTION II5-305, P051TIONED FOR A <br />FORWARD APPROACH, AND KNEE AND TOE CLEARANCE <br />COMPLYING WITH SECTION IIB-306 SHALL BE PROVIDED. <br />EXCEPTIONS: <br />1. A PARALLEL APPROACH COMPLYING WITH SECTION II5-305 <br />SHALL BE PERMITTED TO A KITCHEN SINK IN A SPACE WHERE <br />A GOOK TOP OR CONVENTIONAL RANGE 15 NOT PRO VIDED <br />AND TO NET BARS. <br />2. RESERVED. <br />3. IN RESIDENTIAL DWELLING UNITS, GABINETRY SHALL BE <br />PERMITTED UNDER LAVATORIES AND KITCHEN SINKS <br />PROVIDED THAT ALL OF THE FOLLOWING CONDITIONS ARE <br />MET: <br />(A) THE GA51NETRY CAN BE REMOVED WITHOUT REMOVAL OR <br />REPLACEMENT OF THE FIXTURE; <br />(5) THE FINISH FLOOR EXTENDS UNDER THE GABINETRY; AND <br />(G) THE HALLS BEHIND AND SURROUNDING THE CABINETRY <br />ARE FINISHED. <br />4. A KNEE CLEARANCE OF 24 INCHES (610 MM) MINIMUM <br />ABOVE THE FIN 15H FLOOR OR GROUND SHALL BE PERMITTED <br />AT LAVATORIES AND SINKS USED PRIMARILY BY CHILDREN 6 <br />THROUGH 12 YEARS WHERE THE RIM OR COUNTER SURFACE IS <br />31 INGHE5 (787 MM) MAXIMUM ABOVE THE F I N 15H FLOOR OR <br />GROUND. <br />5. A PARALLEL APPROACH COMPLYING WITH SECTION IIB-305 <br />SHALL BE PERMITTED TO LAVATORIES AND SINKS USED <br />PRIMARILY BY CHILDREN 5 YEARS AND YOUNGER. <br />6. THE DIP OF THE OVERFLOW SHALL NOT BE CONSIDERED IN <br />DETERMINING KNEE AND TOE CLEARANCES. <br />7. NO MORE THAN ONE BOWL OF A MULTI BOWL SINK SHALL <br />BE REQUIRED TO PROVIDE KNEE AND TOE CLEARANCE <br />COMPLYING WITH SECTION IIB-306. <br />I I6-606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE <br />INSTALLED WITH THE FRONT OF THE H16HER OF THE RIM OR <br />COUNTER SURFACE 34 INCHES (864 MM) MAXIMUM ABOVE THE <br />F I N I5H FLOOR OR GROUND. <br />EXCEPTIONS: <br />1. RESERVED. <br />2. IN RESIDENTIAL DWELLING UNIT KITCHENS, SINKS THAT ARE <br />ADJUSTABLE TO VARIABLE HEIGHTS, 21 INCHES (131 MM) <br />MINIMUM AND 36 INCHES (q14 MM) MAXIMUM, SHALL BE <br />PERMITTED WHERE ROU6H-IN PLUMBING PERMITS <br />GONNEGTIONS OF SUPPLY AND DRAIN PIPES FOR 51NK5 <br />MOUNTED AT THE HE16HT OF 21 INCHES (731 MM). <br />IIB-606.4 FAUGET5. CONTROLS FOR FAUCETS SHALL COMPLY <br />WITH SECTION IIB-301. HAND -OPERATED METERING FAUCETS <br />SHALL REMAIN OPEN FOR 10 SECONDS MINIMUM. <br />IIB-606.5 EXPOSED PIPES AND SURFACES. WATER SUPPLY <br />AND DRAIN PIPES UNDER LAVATORIES AND 5INK5 SHALL BE <br />INSULATED OR OTHERWISE GONF16URED TO PROTECT AGAINST <br />CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE <br />SURFACES UNDER LAVATORIES AND SINKS. <br />IIB-606.6 ADJAGENT SIDE WALL OR PARTITION. LAVATORIES, <br />WHEN LOCATED ADJACENT TO A 51DE WALL OR PARTITION, <br />SHALL BE A MINI MUM OF 18 INCHES (457 MM) TO THE <br />GENTERLINE OF THE FIXTURE. <br />5-606.1 SINK DEPTH. WHERE A FORWARD APPROACH IS <br />REQUIRED AT A SINK, KNEE AND TOE CLEARANCE SHALL BE <br />PROVIDED IN GOMPLIANGE WITH SECTION II5-306. <br />B-601 BATHTUBS <br />IIB-601.1 GENERAL. BATHTUBS SHALL COMPLY WITH SECTION <br />B-601. <br />116-601.2 CLEARANCE. CLEARANCE IN FRONT OF BATHTUBS <br />SHALL EXTEND THE LENGTH OF THE BATHTUB AND SHALL BE <br />48 INCHES (121q MM) WIDE MINIMUM FOR FORWARD APPROACH <br />AND 30 INCHES (162 MY) WIDE MINIMUM FOR PARALLEL <br />APPROACH. A LAVATORY GOM PLYING WITH 5EGTION IIBa606 <br />SHALL BE PERMITTED AT THE CONTROL END OF THE <br />CLEARANCE. WHERE A PERMANENT SEAT 15 PROVIDED AT <br />THE HEAD END OF THE BATHTUB, THE CLEARANCE SHALL <br />EXTEND 12 INCHES (305 MM) MINIMUM BEYOND THE WALL AT <br />THE HEAD END OF THE BATHTUB. <br />IIB-605 SHOWER COMPARTMENTS <br />IIB-608.1 GENERAL. SHOWER COMPARTMENTS SHALL COMPLY <br />WITH SECTION IIB-608. <br />IIB-608.2 51ZE AND CLEARANCES FOR SHOWER <br />COMPARTMENTS. <br />5HOWER COMPARTMENTS SHALL HAVE 51 ZE5 AND <br />GLEARANGE5 COMPLYING WITH 5EGTION 15=608.2. <br />IIB-608.2.1 TRANSFER TYPE 5HOWER COMPARTMENTS. <br />TRANSFER TYPE SHOWER GOMPARTMENT5 SHALL BE 36 <br />INCHES (114 MM) BY 36 INCHES (q 14 MM) CLEAR INSIDE <br />D I MEN51 ON5 MEASURED AT THE CENTER POINTS OF OPPOSING <br />SIDES AND SHALL HAVE A 36-INGH (114 MY) WIDE MINIMUM <br />ENTRY ON THE FACE OF THE SHOWER COMPARTMENT. <br />CLEARANCE OF 36 INCHES (114 MM) WIDE MINIMUM BY 48 <br />INGHE5 (1211 MM) <br />LONG MINIMUM MEASURED FROM THE CONTROL WALL SHALL <br />BE PROVIDED. TRANSFER TYPE SHOWER COMPARTMENTS <br />SHALL BE PERMITTED IN TRANSIENT LODGING GUEST ROOMS, <br />MULTI BEDROOM HOUSING UNITS IN UNDERGRADUATE STUDENT <br />HOUSING AND RESIDENTIAL DWELL I N6 UNITS; AND SHALL NOT <br />BE PERMITTED AT OTHER LOCATIONS TO MEET THE <br />REQUIREMENTS OF SECTION 11 3-213.3.6. <br />5-608.2.2 STANDARD ROLL -IN TYPE SHOWER <br />COMPARTMENTS. STANDARD ROLL -IN TYPE SHOWER <br />COMPARTMENTS SHALL BE 30 INGHE5 (162 MM) WIDE MINIMUM <br />BY 60 INCHES (1524 MM) DEEP MINIMUM CLEAR I N51 DE <br />DIMENSIONS MEASURED AT CENTER POINTS OF OPP051 N6 <br />SIDES WITH A FULL OPENING WIDTH ON THE LONG SIDE. <br />II5-608.2.2.1 CLEARANCE. A 36 INCH (114 MM) WIDE MINIMUM <br />BY 60 INCH (1524 MM) LONG MINIMUM CLEARANCE SHALL BE <br />PROVIDED ADJACENT TO THE OPEN FAGS OF THE SHOWER <br />COMPARTMENT. <br />I5-605.2.3 ALTERNATE ROLL -IN TYPE SHOWER <br />COMPARTMENTS. ALTERNATE ROLL -IN TYPE SHOWER <br />COMPARTMENTS SHALL BE 36 INCHES (114 MM) WIDE AND 60 <br />INCHES (1524 MM) DEEP MINIMUM CLEAR IN51DE DIMENSIONS <br />MEASURED AT CENTER POINTS, OF OPPOSING SIDES. A 36 <br />NCH (114 MM) WIDE MINIMUM ENTRY SHALL BE PROVIDED AT <br />ONE END OF THE LONG SIDE OF THE COMPARTMENT. <br />IIB-608.3 GRAB BARS. GRAB BARS SHALL COMPLY WITH <br />SECTION IIB-601 AND SHALL BE PROVIDED IN ACCORDANCE <br />WITH SECTION II5-608.3. WHERE MULTIPLE GRAB BARS ARE <br />USED, REQUIRED HORIZONTAL GRAB BARS SHALL BE <br />INSTALLED AT THE SAME HE16HT ABOVE THE FIN 15H FLOOR. <br />WHERE SEPARATE GRAB 5AR5 ARE REQUIRED ON ADJACENT <br />WALL5 AT A COMMON MOUNTING HEIGHT, AN L-SHAPED OR <br />U-SHAPED GRAB BAR MEETING THE DIMENSIONAL <br />REQUIREMENTS OF SECTION IIB-608.3.2 OR II5-608.3.3 SHALL <br />BE PERMITTED. <br />EXCEPTIONS: <br />I. RESERVED. <br />2. IN RE51 DENTI AL DWELL I N6 UNITS, GRAB BARS SHALL NOT <br />BE REQUIRED TO BE INSTALLED IN SHOWERS LOCATED IN <br />BATHING FACILITIES PROVIDED THAT REINFORGEMENT HAS <br />BEEN INSTALLED IN HALLS AND LOCATED 50 A5 TO PERMIT <br />THE INSTALLATION OF GRAB BARS COMPLYING WITH SECTION <br />B-608.3. <br />I5-608.3.1 TRANSFER TYPE SHOWER COMPARTMENTS. IN <br />TRANSFER TYPE COMPARTMENTS, GRAB BARS SHALL BE <br />PROVIDED ACROSS THE CONTROL WALL AND BACK WALL TO <br />A POINT l8 INCHES (451 MM) FROM THE CONTROL WALL. <br />IIB-608.3.2 STANDARD ROLL -IN TYPE SHOWER <br />COMPARTMENTS. GRAB BARS SHALL BE PROVIDED ON THE <br />BACK WALL AND THE 51DE WALL OPPOSITE THE SEAT. GRAB <br />BARS SHALL NOT BE PROVIDED ABOVE THE SEAT. GRAB <br />5AR5 SHALL BE INSTALLED 6 INGHE5 (752 MM) MAXIMUM <br />FROM ADJACENT HALLS. <br />5-608.3.3 ALTERNATE ROLL -IN TYPE SHOWER <br />COMPARTMENTS. IN ALTERNATE ROLL -IN TYPE SHOWER <br />COMPARTMENTS, GRAB BARS SHALL BE PROVIDED ON THE <br />BACK WALL AND THE 51DE WALL FARTHEST FROM THE <br />COMPARTMENT ENTRY. GRAB BARS SHALL NOT BE PROVIDED <br />ABOVE THE SEAT. GRAB BARS SHALL BE INSTALLED 6 <br />INGHE5 (152 MM) MAXIMUM FROM ADJACENT WALLS. <br />IS-608.4 SEATS. A FOLDING SEAT SHALL BE PROVIDED IN <br />ROLL -IN TYPE SHOWERS AND TRANSFER TYPE SHOWER <br />COMPARTMENTS. SEATS SHALL COMPLY WITH SECTION <br />IIB-610. <br />EXCEPTION: IN RE51DENTIAL DWELLING UNITS, SEATS SHALL <br />NOT BE REQUIRED IN SHOWER GOMPARTMENTS PROVIDED <br />THAT REINFORCEMENT HAS BEEN INSTALLED IN WALL5 50 A5 <br />TO PERMIT THE INSTALLATION OF 5EAT5 COMPLYING WITH <br />SECTION IIB-608.4. <br />II6-608.5 CONTROLS. CONTROLS, FAUCETS, AND SHOWER <br />SPRAY UNITS SHALL COMPLY WITH SECTION II6-301.4. <br />CONTROLS AND FAUCETS SHALL ALLOW THE USER TO CLOSE <br />AND OPEN THE WATER SUPPLY. <br />I5-608.5.1 TRANSFER TYPE SHOWER COMPARTMENTS. IN <br />TRANSFER TYPE SHOWER GOMPARTMENT5, THE GONTROL5, <br />FAUCETS, AND SHOWER SPRAY UNIT SHALL BE INSTALLED ON <br />THE SIDE WALL OPPOSITE THE SEAT 38 INCHES (165 MM) <br />MINIMUM AND 48 INCHES (1211 MM) MAXIMUM ABOVE THE <br />5HOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL <br />WALL 15 INCHES (380 MM) MAXIMUM FROM THE GENTERLINE OF <br />THE SEAT TOWARD THE SHOWER OPENING. <br />I5-605.5.2 STANDARD ROLL -IN TYPE SHOWER <br />COMPARTMENTS. IN STANDARD ROLL -IN TYPE SHOWER <br />COMPARTMENTS, OPERABLE PARTS OF CONTROLS AND <br />FAUCETS SHALL BE INSTALLED ON THE BACK WALL OF THE <br />COMPARTMENT ADJACENT TO THE SEAT WALL 11 INCHES (483 <br />MM) MINIMUM AND 21 INGHE5 06 MM) MAXIMUM FROM THE <br />SEAT WALL. AND SHALL BE LOCATED ABOVE THE GRAB BAR, <br />BUT NO H16HER THAN 48 INCHES (1211 MM) ABOVE THE <br />SHOWER FLOOR, WITH THEIR GENTERLINE AT 31 INCHES (qq I <br />MM) TO 41 INCHES (1041 MM) ABOVE THE SHOWER FLOOR. <br />OPERABLE PARTS OF THE SHOWER SPRAY UNIT, I NGLUD I N6 <br />THE HANDLE, SHALL BE INSTALLED ON THE BACK WALL <br />ADJACENT TO THE SEAT WALL 11 INCHES (483 MM) MINIMUM <br />AND 27 INCHES 06 MM) MAXIMUM FROM THE SEAT WALL; <br />AND SHALL BE LOCATED ABOVE THE GRAB BAR, BUT NO <br />H16HER THAN 48 INCHES (1211 MM) ABOVE THE SHOWER <br />FLOOR. <br />IIB-608.5.3 ALTERNATE ROLL -IN TYPE SHOWER <br />COMPARTMENTS. IN ALTERNATE ROLL -IN TYPE 5HOWER <br />COMPARTMENTS, OPERABLE PARTS OF CONTROLS AND <br />FAUCETS SHALL BE INSTALLED ON THE 51DE WALL OF THE <br />COMPARTMENT ADJACENT TO THE SEAT WALL H INCHES <br />(483 MM) MINIMUM AND 21 INGHES (686 MM) MAXIMUM F5Wa <br />THE SEAT WALL; AND SHALL BE LOCATED ABOVE TH GRAB <br />BAR, BUT NO H16HER THAN 48 INCHES (I211 MM) A50 E THE <br />SHOWER FLOOR, WITH THEIR GENTERLINE AT 3q INCHES (qI I <br />MY) TO 41 I NGHE5 (1041 MM) ABOVE THE SHOWER FLC OR. <br />OPERABLE PARTS OF THE SHOWER SPRAY UNIT, INGL DIN6 <br />THE HANDLE, SHALL BE INSTALLED ON THE 51DE HAL OF H <br />COMPARTMENT ADJACENT TO THE SEAT WALL 17 INC 4ES <br />MY) MINI MUM AND I 1 INGHE5 (483 MM) MAXIMUM FR THE <br />SEAT WALL OR ON THE BACK WALL OPPOSITE THE 5 AT 15 <br />INCHES (381 MY) MAXIMUM, LEFT OR RIGHT, OF THE <br />GENTERLINE OF THE SEAT, AND SHALL BE LOCATED BOVE <br />THE GRAB BAR, BUT NO H16HER THAN 48 INCHES (121 "a < <br />ABOVE THE SHOWER FLOOR. <br />5-608.6 SHOWER SPRAY UNIT AND WATER. A SHOW RD a t <br />SPRAY UNIT WITH A HOSE 5q INCHES (14g1 MY) LONG MINIMUM <br />THAT GAN BE USED BOTH A5 A FIXED -POSITION SHOVER <br />HEAD AND A5 A HANDHELD SHOWER SHALL BE PROV1777- <br />THE SHOWER SPRAY UNIT SHALL HAVE AN ON/OFF CONTROL <br />WITH A NON -POSITIVE SHUT-OFF. IF AN ADJU5TABLE-HE16HT <br />5HOWER HEAD ON A VERTICAL BAR 15 USED, THE BAR SHALL <br />BE INSTALLED So AS NOT TO OBSTRUCT THE USE OF GRAB <br />BARS. SHOWER SPRAY UNITS SHALL DELIVER WATER THAT 15 <br />120F (4qC) MAXIMUM. <br />EXCEPTION: WHERE SUBJECT TO EXCESSIVE VANDALISM, TWO <br />FIXED SHOWER HEADS SHALL BE PERMITTED INSTEAD OF A <br />HANDHELD SPRAY UNIT IN FACILITIES THAT ARE NOT MEDIGAI <br />CARE FACILITIES, LON6-TERM CARE FACILITIES, TRANSIENT <br />LODGING GUEST ROOMS, OR RESIDENTIAL DWELLING UNITS. <br />EACH SHOWER HEAD SHALL BE INSTALLED SO IT GAN BE <br />OPERATED INDEPENDENTLY OF THE OTHER AND SHALL HAVE <br />SWIVEL ANGLE ADJUSTMENTS, BOTH VERTICALLY AND <br />HORIZONTALLY. ONE SHOWER HEAD SHALL BE LOCATED AT A <br />HE16HT OF 48 INCHES (1211 MM) MAXIMUM ABOVE THE SHOWEF <br />FIN 15H FLOOR. <br />IIB-608.1 THRESHOLDS. THRESHOLDS IN ROLL -IN TYPE <br />5HOWER COMPARTMENTS SHALL BE 1/2" INCH (12.1 MM) H16H <br />MAXIMUM IN AGGORDANGE WITH SECTION II6-303. IN <br />TRANSFER TYPE SHOWER COMPARTMENTS, THRESHOLDS 1/2" <br />NCH (12.7 MM) H16H MAXIMUM SHALL BE BEVELED, ROUNDED, <br />OR VERTICAL. <br />II6-608.8 SHOWER ENCLOSURES. ENCLOSURES FOR 5HOWER <br />GOMPARTMENT5 SHALL NOT OBSTRUCT GONTROL5, FAUCETS, <br />AND SHOWER SPRAY UNITS OR OBSTRUCT TRANSFER FROM <br />WHEELGHAIR5 ONTO SHOWER SEATS. <br />II5-608.1 SHOWER FLOOR OR GROUND SURFACE. FLOOR OR <br />GROUND SURFACES OF SHOWERS SHALL COMPLY WITH <br />SECTION II5-302.1 AND SHALL BE SLOPED 1:48 MAXIMUM IN <br />ANY DIRECTION. WHERE DRAINS ARE PROVIDED, GRATE <br />OPENIN65 SHALL BE 1/4" INCH (6.4 MM) MAXIMUM AND FLUSH <br />WITH THE FLOOR SURFACE. <br />5=608.10 SOAP DISH. WHERE A SOAP DI5H 15 PROVIDED, IT <br />SHALL BE LOCATED ON THE CONTROL WALL AT 40 INCHES <br />(1016 MY) MAXIMUM ABOVE THE SHOWER FLOOR, ARID WITHIN <br />THE REACH L I M I T5 FROM THE SEAT. <br />II6-601.2 CROSS SECTION. GRAB BARS SHALL HAVE A <br />GRO55 SECTION COMPLYING WITH SECTION I15-60q 2.1 OR <br />115-60q 2.2. <br />IIB-601.2.1 GIRGULAR GRO55 SECTION. GRAB BARS WITH <br />CIRCULAR GROSS SECTIONS SHALL HAVE AN OUT51 DE <br />DIAMETER OF 1/4" INCHES (32 MY) MINIMUM AND 2 INCHES (51 <br />MM) MAXIMUM. <br />II6-601.2.2 NON-GIRGULAR GROSS SECTION. GRAB BARS WIT <br />NON-GIRGULAR GROSS SECTIONS SHALL HAVE A <br />CR055-5EGTION DIMENSION OF 2 INCHES (51 MM) MAXIMUM <br />AND A PERIMETER DIMENSION OF 4 INGHE5 (102 MM) MINIMUM <br />AND 4.8 INCHES (122 MM) MAXIMUM. <br />II6-60q 3 SPACING. THE SPACE BETWEEN THE WALL AND THE <br />GRAB BAR SHALL BE 1/2" INCHES (38 MY). THE SPACE <br />BETWEEN THE GRAB BAR AND PROJECTING OBJECTS BELOW <br />AND AT THE EN05 SHALL BE 1/2" INCHES (38 MM) MINIMUM. <br />THE 5PAGE BETWEEN THE GRAB BAR AND PROJECTING <br />OBJECTS ABOVE SHALL BE 12 INGHE5 (305 MM) MINIMUM. <br />IIB-60gA POSITION OF GRAB BARS. GRAB BARS SHALL BE <br />INSTALLED IN A HORIZONTAL POSITION, 33 INGHE5 (838 MY) <br />MINIMUM AND 36 INCHES (q14 MM) MAXIMUM ABOVE THE FIN& <br />FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE, <br />EXCEPT THAT AT WATER CLOSETS FOR CHILDREN'S USE <br />COMPLYING WITH SECTION II5-604.1, GRAB BARS SHALL BE <br />INSTALLED IN A HORIZONTAL P051 T I ON 18 INCHES (451 MM) <br />MINIMUM AND 27 INCHES (686 MM) MAXIMUM ABOVE THE <br />F I N I5H FLOOR MEASURED TO THE TOP OF THE 6R1 PP I N6 <br />SURFACE. THE HE16HT OF THE LOWER GRAB BAR ON THE <br />BACK WALL OF A BATHTUB SHALL COMPLY WITH SECTION <br />II6-601.4.1.1 OR II8=601.4.2.1. <br />5-601.5 SURFACE HAZARDS. GRAB BARS AND ANY WALL <br />OR OTHER SURFACES ADJACENT TO GRAB BARS SHALL BE <br />FREE OF SHARP OR ABRASIVE ELEMENTS AND SHALL HAVE <br />ROUNDED EDGES. <br />IIB-60q.6 FITTINGS. GRAB BARS SHALL NOT ROTATE WITHIN <br />THEIR FITTINGS. <br />IIB-601.7 INSTALLATION. GRAB BARS SHALL BE INSTALLED I> <br />ANY MANNER THAT PROVIDES A GRIPPING 5URFACE AT THE <br />SPECIFIED LOCATIONS AND THAT DOES NOT OBSTRUCT THE <br />REQUIRED CLEAR FLOOR SPACE. <br />II5-60q.8 5TRUGTURAL STRENGTH. ALLOWABLE STRESSES <br />SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A <br />VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS (1112 N) 15 <br />APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER, <br />MOUNTING DEVICE, OR SUPPORTING STRUCTURE. <br />IIB-601.1 ALTERNATE CONFIGURATION. L-SHAPED OR <br />U-SHAPED GRAB BARS SHALL BE PERMITTED. <br />architecture & planning <br />er4a- MITCHEL_L- N. SUITE 'C' <br />IRVINE, CALIFORNIA 92614 <br />PHONE: (949) <br />FAX: (949) <br />752-1177 <br />rAIP PAKOJI S <br />©KNITTER PARTNERS INTERNATIONAL <br />ALL RIGHTS RESERVED 2025 <br />THIS DOCUMENT IS THE PROPERTY AND COPYRIGHT OF <br />KNITTER PARTNERS INTERNATIONAL, INC. AND SHALL NOT BE <br />USE ON ANY OTHER WORK, BE REPRODUCED OR DISCLOSED TO <br />OTHERS EXCEPT BY WRITTEN AUTHORIZATION FROM KNITTER <br />PARTNERS INTERNATIONAL., INC. <br />1111117ma <br />Oq-16-25 <br />Q <br />Ey <br />0 <br />U <br />C7 <br />a <br />InwvAI6,4E*]al <br />m <br />kn <br />O <br />N <br />m <br />PROJECT INFO <br />GENERAL <br />JOB NUMBER 24077 <br />PROJECT MGR. PB <br />DRAWN BY 5TAFF <br />PLOT DATE: 10-14-2025 <br />SHEET TITLE <br />GENERAL NOTES <br />SHEET NUMBER <br />r� <br />Cy <br />