<br />IIB-505.10.3 BOTTOM EXTENSION AT STAIRS. AT THE BOTTOM
<br />OF A STAIR FLIGHT, HANDRA I L5 SHALL EXTEND AT THE
<br />SLOPE OF THE STAIR FL 16HT FOR A HORIZONTAL DISTANCE
<br />EQUAL TO ONE TREAD DEPTH BEYOND THE LAST RISER
<br />NOSING. THE HORIZONTAL EXTENSION OF A HANDRAIL SHALL
<br />BE 12 INCHES (305 MM) LONG MINI MUM AND A HEIGHT EQUAL
<br />TO THAT OF THE SLOPING PORTION OF THE HANDRAIL AS
<br />MEASURED ABOVE THE STAIR NOSING. EXTENSION SHALL
<br />RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR
<br />SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT
<br />STAIR FLIGHT.
<br />PLUMB I NG ELEMENT5 AND FAG I L I T I E5
<br />DIVISION 6
<br />II5-603 TOILET AND BATHING ROOMS
<br />IIB-603.2 CLEARANCES. CLEARANCES SHALL COMPLY WITH
<br />SECTION IIB-603.2.
<br />II6-603.2.1 TURNING SPACE. TURNING SPACE COMPLYING WITH
<br />SECTION II5-304 SHALL BE PROVIDED WITHIN THE ROOM.
<br />15-603.2.2 OVERLAP. REQUIRED CLEAR FLOOR SPACES,
<br />CLEARANCE AT FIXTURES, AND TURNING SPACE SHALL BE
<br />PERMITTED TO OVERLAP.
<br />IIB-603.2.3 DOOR 5WIN6. DOORS SHALL NOT SWING INTO THE
<br />CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY
<br />FIXTURE. DOORS TO AGGE551BLE WATER CLOSET
<br />GOMPARTMENT5 SHALL BE PERMITTED TO ENCROACH INTO
<br />THE TURNING SPACE WITHOUT LIMITATION. OTHER THAN DOORS
<br />TO ACCESSIBLE WATER CLOSET COMPARTMENTS, A DOOR, IN
<br />ANY POSITION, SHALL BE PERMITTED TO ENCROACH INTO THE
<br />TURNING SPACE BY 12 INCHES (305 MM) MAXIMUM.
<br />II5-603.3 MIRRORS. MIRRORS LOCATED ABOVE LAVATORIES
<br />OR GOUNTERTOP5 SHALL BE INSTALLED WITH THE BOTTOM
<br />EDGE OF THE REFLECTING SURFACE 40 INCHES (1016 MM)
<br />MAXIMUM ABOVE THE FIN15H FLOOR OR GROUND. MIRRORS
<br />NOT LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
<br />BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
<br />SURFACE 35 INCHES (881 MM) MAXIMUM ABOVE THE F I N 15H
<br />FLOOR OR GROUND.
<br />II5-603.5 ACCESSORIES. WHERE TOWEL OR SANITARY NAPKIN
<br />DISPENSERS, WASTE REGEPTAGLE5, OR OTHER AGGE55ORIE5
<br />ARE PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF
<br />EACH TYPE SHALL BE LOCATED ON AN ACCESSIBLE ROUTE.
<br />ALL OPERABLE PARTS, I NGLUD I N6 C01 N SLOTS, SHALL BE 40
<br />INCHES (1016 MM) MAXIMUM ABOVE THE FINISH FLOOR.
<br />II6-604 WATER CLOSETS AND TOILET COMPARTMENTS
<br />II5-604.2 LOCATION. THE WATER CLOSET SHALL BE
<br />POSITIONED WITH A WALL OR PARTITION TO THE REAR AND
<br />TO ONE SIDE. THE GENTERLINE OF THE WATER CLOSET SHALL
<br />BE 77 INCHES (432 MY) MINIMUM TO 18 INCHES (451 MY)
<br />MAXIMUM FROM THE 51DE WALL OR PARTITION, EXCEPT THAT
<br />THE WATER CLOSET SHALL BE 11 INCHES (432 MM) MINIMUM
<br />AND 11 INCHES (483 MM) MAXIMUM FROM THE 51DE WALL OR
<br />PARTITION IN THE AMBULATORY ACCESSIBLE TOILET
<br />GOMPART MENT SPECIFIED IN SECTION 115-604.8.2. WATER
<br />CLOSETS SHALL BE ARRANGED FOR A LEFT-HAND OR
<br />R16HT-HAND APPROACH.
<br />II6-604.3 CLEARANCE. CLEARANCES AROUND WATER
<br />CLOSETS AND IN TOILET COMPARTMENTS SHALL COMPLY
<br />WITH SECTION II5-604.3.
<br />II5-604.3.1 SIZE. GLEARANGE AROUND A WATER CLOSET
<br />SHALL BE 60 INCHES (1524 MM) MINIMUM MEASURED
<br />PERPEND I GUAAR FROM THE SIDE WALL AND 56 INCHES (1422
<br />MM) MINIMUM MEASURED PERPENDICULAR FROM THE REAR
<br />WALL. A MINIMUM 60 INCHES (1524 MM) WIDE AND 48 INCHES
<br />(12lq MM) DEEP MANEUVERING SPACE SHALL BE PROVIDED IN
<br />FRONT OF THE WATER CLOSET.
<br />EXCEPTION: IN RESIDENTIAL DWELLING UNITS COMPLYING WITH
<br />SECTION II5-233.3.1.1, MANEUVERING SPACE IN FRONT OF THE
<br />WATER CLOSET SHALL BE A MINIMUM 60 INCHES (1524 MM)
<br />WIDE AND 36 INCHES (q 14 MM) DEEP.
<br />II5-604.3.2 OVERLAP. THE REQUIRED CLEARANCE AROUND
<br />THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE
<br />WATER CLOSET, A550G I ATED GRAB BARS, DISPENSERS,
<br />SANITARY NAPKIN DISPOSAL UNITS, GOAT HOOK5, SHELVES,
<br />AGGE551 BLE ROUTES, CLEAR FLOOR SPACE AND
<br />CLEARANCES REQUIRED AT OTHER FIXTURES, AND THE
<br />TURNING SPACE. NO OTHER FIXTURES OR 055TRUGTION5
<br />SHALL BE LOCATED WITHIN THE REQUIRED WATER GL05ET
<br />CLEARANCE.
<br />IIB-604.4 SEATS. THE SEAT HE16HT OF A WATER CLOSET
<br />ABOVE THE F I N I5H FLOOR SHALL BE 11 INCHES (432 MM)
<br />MINIMUM AND H INCHES (483 MM) MAXIMUM MEASURED TO THE
<br />TOP OF THE SEAT. SEATS SHALL NOT BE SPRUNG TO RETURN
<br />TO A LIFTED POSITION. SEATS SHALL BE 2 INCHES (51 MM)
<br />H16H MAXIMUM.
<br />I5-604.5 GRAB BARS. GRAB BARS FOR WATER CLO5ET5
<br />SHALL GOM PLY WITH 5EGTION II5-601. GRAB BARS SHALL
<br />BE PROVIDED ON THE SIDE WALL CLOSEST TO THE WATER
<br />CLOSET AND ON THE REAR WALL. WHERE SEPARATE GRAB
<br />5AR5 ARE REQUIRED ON ADJACENT WALLS AT A GOMMON
<br />MOUNTING HEIGHT, AN L-SHAPED GRAB BAR MEETING THE
<br />DIMEN51ONAL REQUIREMENTS OF 5EGTION5 115-604.5.1 AND
<br />I5-604.5.2 SHALL BE PERMITTED.
<br />II5-604.5.1 51DE WALL. THE 51DE WALL GRAB BAR SHALL BE
<br />42 INCHES (1067 MM) LONG MINIMUM, LOCATED 12 INGHE5 (305
<br />MM) MAXIMUM FROM THE REAR WALL AND EXTENDING 54
<br />INCHES (1312 MM) MINIMUM FROM THE REAR WALL WITH THE
<br />FRONT END P051TIONED 24 INCHES (610 MM) MINIMUM IN
<br />FRONT OF THE WATER CLOSET.
<br />IIB-604.5.2 REAR WALL. THE REAR WALL GRAB BAR SHALL
<br />BE 36 INCHES (114 MM) LONG MINIMUM AND EXTEND FROM THE
<br />GENTERLINE OF THE WATER CLOSET 12 INCHES (305 MM)
<br />MINIMUM ON ONE SIDE AND 24 INCHES (610 MM) MINIMUM ON
<br />THE OTHER SIDE.
<br />II5=604.6 FLUSH GONTROL5. FLUSH GONTROLS SHALL BE
<br />HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH
<br />GONTROL5 SHALL COMPLY WITH SECTION IIB-30q EXGEPT
<br />THEY SHALL BE LOCATED 44 INCHES (1115 MM) MAXIMUM
<br />ABOVE THE FLOOR. FLUSH CONTROLS SHALL BE LOCATED ON
<br />THE OPEN 51DE OF THE WATER CLOSET EXCEPT IN
<br />AMBULATORY ACCESSIBLE COMPARTMENTS COMPLYING WITH
<br />SECTION II5-604.8.2. I5-604.1 DISPENSERS AND DISPOSAL
<br />UNITS. TOILET PAPER DISPENSERS AND 5AN I TARY NAPKIN
<br />DISPOSAL UNITS SHALL COMPLY WITH SECTION 5-604.1.
<br />COMBINATION ACCESSORY UNITS ARE NOT PERMITTED TO
<br />ENCROACH INTO THE SPACE REQUIRED BY SECTION II5-601.3.
<br />II6-604.1.1 DISPENSERS. TOILET PAPER DISPENSERS SHALL
<br />COMPLY WITH SECTION II5-301.4 AND SHALL BE 7 INCHES
<br />(778 MM) MINIMUM AND q INGHE5 (221 MM) MAXIMUM IN FRONT
<br />OF THE WATER CLOSET MEASURED TO THE GENTERLINE OF
<br />THE DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE
<br />BELOW THE GRAB BAR, 11 INCHES (483 MM) MINIMUM ABOVE
<br />THE FINISH FLOOR AND SHALL NOT BE LOCATED BEHIND
<br />GRAB BARS. 015PEN5ER5 SHALL NOT BE OF A TYPE THAT
<br />CONTROLS DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS
<br />PAPER FLOW.
<br />II5=604.7.2 DISPOSAL UNITS. SANITARY NAPKIN DISPOSAL
<br />UNITS, IF PROVIDED, SHALL COMPLY WITH SECTION IIB-301.4
<br />AND SHALL BE WALL MOUNTED AND LOCATED ON THE
<br />51DENALL BETWEEN THE REAR WALL OF THE TOILET AND THE
<br />TOILET PAPER DISPENSER, ADJACENT TO THE TOILET PAPER
<br />DISPENSER. THE DISPOSAL UNIT SHALL BE LOCATED BELOW
<br />THE GRAB BAR WITH THE OPENING OF THE DISPOSAL UNIT I1
<br />INGHE5 MINIMUM (483 MM) ABOVE THE FINISH FLOOR.
<br />B-604.8 TOILET GOMPARTMENT5. WHEELGHAIR ACCESSIBLE
<br />TOILET COMPARTMENTS SHALL MEET THE REQUIREMENTS OF
<br />SECTIONS IIB-604.8.1 AND IIB-604.5.3. COMPARTMENTS
<br />CONTAINING MORE THAN ONE PLUMBING FIXTURE SHALL
<br />COMPLY WITH SECTION 115-603. AMBULATORY ACCESSIBLE
<br />GOMPARTMENT5 SHALL COMPLY WITH 5EGTION5 II5-604.5.2
<br />AND II5-604.8.3.
<br />IIB-604.8.1 WHEELGHAIR AGGE55IBLE COMPARTMENTS.
<br />WHEELGHAIR ACCESSIBLE COMPARTMENTS SHALL COMPLY
<br />WITH SECTION IIB-604.8.1.
<br />II6-604.5.1.1 SIZE. WHEELGHAIR ACCESSIBLE COMPARTMENTS
<br />SHALL BE 60 INCHES (1524 MM) WIDE MINIMUM MEASURED
<br />PERPENDICULAR TO THE 51DE WALL, AND 56 INCHES (1422 MM)
<br />DEEP MINIMUM FOR WALL HUNG WATER CLOSETS AND 51
<br />INGHE5 (14g1 MM) DEEP MINIMUM FOR FLOOR MOUNTED WATER
<br />CLOSETS MEASURED PERPENDICULAR TO THE REAR WALL.
<br />WHEELGHAIR ACCESSIBLE COMPARTMENTS SHALL
<br />ADDITIONALLY PROVIDE MANEUVERING SPACE COMPLYING
<br />WITH SECTION IIBs604.8.1.I.I, II5-604.8.1.1.21 OR II5-604.8.1.1.3,
<br />AS APPLICABLE. WHEELGHAIR ACCESSIBLE COMPARTMENTS
<br />FOR GHILDREN5 USE SHALL BE 60 INGHE5 (1524 MM) WIDE
<br />MINIMUM MEASURED PERPENDICULAR TO THE SIDE WALL, AND
<br />51 INCHES (14gq MM)DEEP MINIMUM FOR WALL HUNG AND
<br />FLOOR MOUNTED WATER CLOSETS MEASURED
<br />PERPENDICULAR TO THE REAR WALL.
<br />115-604.8. I.1.I MANEUVERING SPACE WITH N-5W I N61 N6 DOOR.
<br />IN A WHEELGHAIR ACCESSIBLE COMPARTMENT WITH AN
<br />IN-5WIN61N6 DOOR, A MINIMUM 60 INCHES (1524 MM) WIDE BY
<br />36 INCHES (q14 MM) DEEP MANEUVERING SPACE SHALL BE
<br />PROVIDED IN FRONT OF THE GLEARANGE REQUIRED IN
<br />SECTION II8-604.8.1.1. SEE FIGURES IIB-604.8.1.1.2 (B) AND
<br />IIB-604.8.I.1.3 (B).
<br />II5-604.5.1.1.2 MANEUVERING SPACE WITH 51DE-OPENING
<br />DOOR. IN A WHEELGHAIR AGCE551 BLE COMPARTMENT WITH A
<br />DOOR LOCATED IN THE SIDE WALL OR PARTITION, EITHER
<br />IN -SWINGING OR OUT -SWINGING, A MINIMUM 60 INGHE5 (1524
<br />MM) WIDE AND 60 INGHE5 (1524 MM) DEEP MANEUVERING
<br />SPACE SHALL BE PROVIDED IN FRONT OF THE WATER
<br />CLOSET. SEE FIGURE II5-604.8.1.1.2.
<br />II5-604.8.1.1.3 MANEUVERING SPACE WITH END OPENING DOOR.
<br />IN A WHEELGHAIR ACCESSIBLE COMPARTMENT WITH A DOOR
<br />LOCATED IN THE FRONT WALL OR PARTITION (FAGIN6 THE
<br />WATER CLOSET), EITHER N-5W I N61 N6 OR OUT-5W1 W N6, A
<br />MINIMUM 60 INGHE5 (1524 MM) WIDE AND 48 INGHE5 (1211 MM)
<br />DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT
<br />OF THE WATER CLOSET. SEE FIGURE IIB-604.8.1.1.3.
<br />IIB-604.8.1.2 DOORS. TOILET COMPARTMENT DOORS,
<br />INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION
<br />115-404 EXCEPT THAT IF THE APPROACH 15 FROM THE PUSH
<br />SIDE OF THE COMPARTMENT DOOR, CLEARANCE BETWEEN THE
<br />DOOR SIDE OF THE COMPARTMENT AND ANY OB5TRUGTION
<br />SHALL BE 48 INCHES (121 1 MM) MINIMUM MEASURED
<br />PERPENDICULAR TO THE COMPARTMENT DOOR IN ITS CLOSED
<br />POSITION. DOORS SHALL BE LOCATED IN THE FRONT
<br />PARTITION OR IN THE SIDE WALL OR PARTITION FARTHEST
<br />FROM THE WATER CLOSET. WHERE LOCATED IN THE FRONT
<br />PARTITION, THE DOOR OPENING SHALL BE 4 INCHES (102 MM)
<br />MAXIMUM FROM THE 51DE WALL OR PARTITION FARTHEST
<br />FROM THE WATER CLOSET. WHERE LOCATED IN THE 51DE
<br />WALL OR PARTITION, THE DOOR OPENING SHALL BE 4 INCHES
<br />(102 MM) MAXIMUM FROM THE FRONT PARTITION. THE DOOR
<br />SHALL BE SELF-GL051N6. A DOOR PULL COMPLYING WITH
<br />SECTION II5-404.2.1 SHALL BE PLACED ON BOTH SIDES OF
<br />THE DOOR NEAR THE LATCH. DOORS SHALL NOT 5WIN6 INTO
<br />THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR
<br />ANY FIXTURE. DOORS MAY 5WIN6 INTO THAT PORTION OF
<br />MANEUVERING SPACE WHIGH DOES NOT OVERLAP THE
<br />CLEARANCE REQUIRED AT A WATER CLOSET.
<br />5-604.8.1.3 APPROACH. COMPARTMENTS SHALL BE
<br />ARRANGED FOR LEFT-HAND OR R16HT-HAND APPROACH TO
<br />THE WATER CLOSET.
<br />II5-604.8.1.4 TOE GLEARANGE. AT LEAST ONE 51DE PARTITION
<br />SHALL PROVIDE A TOE CLEARANCE OF q INCHES (22q MM)
<br />MINIMUM ABOVE THE FINISH FLOOR AND 6 INCHES (152 MM)
<br />DEEP MINIMUM BEYOND THE COMPARTMENT- 51DE FACE OF
<br />THE PARTITION, EXCLUSIVE OF PARTITION SUPPORT MEMBERS.
<br />PARTITION GOMPONENT5 AT TOE CLEARANCES SHALL BE
<br />SMOOTH WITHOUT SHARP EDGES OR ABRASIVE SURFACES.
<br />COMPARTMENTS FOR GHILDREN5 USE SHALL PROVIDE A TOE
<br />CLEARANCE OF 12 INCHES (305 MM) MINIMUM ABOVE THE
<br />F I N I5H FLOOR.
<br />EXCEPTION: TOE CLEARANCE AT THE 51DE PARTITION 15 NOT
<br />REQUIRED IN A COMPARTMENT GREATER THAN 66 INCHES
<br />(1616 MM) WIDE.
<br />5-604.8.15 GRAB BARS. GRAB BARS SHALL COMPLY WITH
<br />SECTION IIB-60q. A SIDE -WALL GRAB BAR GOMPLYIN6 WITH
<br />SECTION IIB-604.5.1 SHALL BE PROVIDED AND SHALL BE
<br />LOCATED ON THE WALL CLOSEST TO THE WATER CLOSET. IN
<br />ADDITION, A REAR -WALL GRAB BAR COMPLYING WITH
<br />SECTION IIB-604.5.2 SHALL BE PROVIDED. WHERE SEPARATE
<br />GRAB BARS ARE REQUIRED ON ADJACENT WALLS AT A
<br />COMMON MOUNTING HEIGHT, AN L-SHAPED GRAB BAR MEETING
<br />THE D I MEN51 ONAL REQUIREMENTS OF SECTIONS 118-604.5.1
<br />AND IIB-604.5.2 SHALL BE PERMITTED.
<br />II6-604.8.2 AMBULATORY ACCESSIBLE COMPARTMENTS.
<br />AMBULATORY ACCESSIBLE COMPARTMENTS SHALL COMPLY
<br />WITH SECTION II5-604.8.2.
<br />I5-604.8.2.1 SIZE. AMBULATORY ACCESSIBLE GOMPARTMENTS
<br />SHALL HAVE A DEPTH OF 60 INCHES fE1524 MM) MINI MUM
<br />AND A WIDTH OF 35 INCHES f' 881 MM) MINIMUM AND 37
<br />INCHES (140 MM) MAXIMUM.
<br />II6-604.8.2.2 DOORS. TOILET COMPARTMENT DOORS,
<br />INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION
<br />II6-404, EXCEPT THAT IF THE APPROACH 15 TO THE LATCH
<br />SIDE OF THE COMPARTMENT DOOR, CLEARANCE BETWEEN THE
<br />DOOR SIDE OF THE COMPARTMENT AND ANY 05STRUGTION
<br />SHALL BE 44 INCHES (IIIS MM) MINIMUM. THE DOOR SHALL BE
<br />SELF GL051N6. A DOOR PULL COMPLYING WITH SECTION I15-
<br />404.2.1 SHALL BE PLACED ON BOTH SIDES OF THE DOOR
<br />NEAR THE LATCH. TOILET COMPARTMENT DOORS SHALL NOT
<br />SANG INTO THE MINIMUM REQUIRED COMPARTMENT AREA.
<br />IS-604.5.2.3 GRAB BARS. GRAB BARS SHALL COMPLY WITH
<br />SECTION II5-601. A SIDE -WALL GRAB BAR GOMPLYIN6 WITH
<br />SECTION IIB-604.5.1 SHALL BE PROVIDED ON BOTH 51DE5 OF
<br />THE COMPARTMENT.
<br />115-604.8.3 COAT HOOKS AND SHELVES. GOAT HOOKS
<br />SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES
<br />SPECIFIED IN SECTION 115-308. SHELVES SHALL BE LOCATED
<br />40 INCHES t 1016 MM) MINIMUM AND 48 INCHES (121q MM)
<br />MAXIMUM ABOVE THE FINISH FLOOR.
<br />II5-604.q WATER CLOSETS AND TOILET COMPARTMENTS FOR
<br />GHILDREN'S USE. WATER GL05ET5 AND TOILET
<br />COMPARTMENTS FOR GHILDREN'S USE SHALL COMPLY WITH
<br />SECTION II5-604.1. WHEN THE EXCEPTION IN SECTION II5-604.1
<br />15 USED, THE 5U66E5TED DIMENSIONS OF TABLE II5-6041
<br />FOR A SINGLE AGE GROUP SHALL BE APPLIED CONSISTENTLY
<br />TO THE INSTALLATION OF A WATER CLOSET AND ALL
<br />A550GIATED GOMPONENT5.
<br />I5-604.q.1 LOCATION. THE WATER CLOSET SHALL BE
<br />LOCATED WITH A WALL OR PARTITION TO THE REAR AND TO
<br />ONE SIDE. THE GENTERLINE OF THE WATER CLOSET SHALL BE
<br />12 INCHES (305 MM) MINIMUM AND 18 INCHES T457 MM)
<br />MAXIMUM FROM THE 51DE WALL OR PARTITION, EXCEPT THAT
<br />THE WATER GL05ET SHALL BE 11 INGHE5 fE432 MM) MINIMUM
<br />AND 11 INCHES t483 MM) MAXIMUM FROM THE 51DE WALL OR
<br />PARTITION IN THE AMBULATORY AGGE5515LE TOILET
<br />COMPARTMENT SPECIFIED IN SECTION 118-604.8.2.
<br />COMPARTMENTS SHALL BE ARRANGED FOR LEFT-HAND OR
<br />RIGHT-HAND APPROACH TO THE WATER CL05ET.
<br />115-604.1.2 CLEARANCE. CLEARANCE AROUND A WATER
<br />GL05ET SHALL COMPLY WITH SECTION IIB-604.3.
<br />IIB-604.q.3 HEIGHT. THE HE16HT OF WATER CLOSETS SHALL
<br />BE 11 INGHE5 (27q MM) MINIMUM AND 11 INCHES t432 MM)
<br />MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS SHALL
<br />NOT BE SPRUNG TO RETURN TO A LIFTED POSITION.
<br />II6-604.1.4 GRAB BARS. GRAB BARS FOR WATER CLOSETS
<br />SHALL COMPLY WITH SECTION II5-604.5.
<br />5-604.q.5 FLUSH CONTROLS. FLUSH GONTROLS SHALL BE
<br />HAND OPERATED OR AUTOMATIC. HAND OPERATED HUSH
<br />CONTROLS SHALL COMPLY WITH SEGTION5 IIB-30q.2 AND
<br />15-301.4 AND SHALL BE INSTALLED 36 INGHE5 (114 MM)
<br />MAXIMUM ABOVE THE FINISH FLOOR. FLUSH CONTROLS SHALL
<br />BE LOCATED ON THE OPEN 51DE OF THE WATER CLOSET
<br />EXCEPT IN AMBULATORY ACCESSIBLE COMPARTMENTS
<br />COMPLYING WITH SECTION IIB-604.8.2.
<br />IIB-604.q.6 DISPENSERS. TOILET PAPER D I5PEN5ER5 SHALL
<br />COMPLY WITH 5EGTION II5-301.4 AND SHALL BE 7 INGHE5 (178
<br />MM) MINIMUM AND q INGHE5 (22q MM) MAXIMUM IN FRONT OF
<br />THE WATER CLOSET MEASURED TO THE GENTERLINE OF THE
<br />DISPENSER, THE OUTLET OF THE DISPENSER SHALL BE 14
<br />INCHES (356 MM) MINIMUM AND I 1 INCHES (483 MM) MAXIMUM
<br />ABOVE THE F I N I5H FLOOR. THERE SHALL BE A CLEARANCE
<br />OF 1 1/2" INCHES (35 MM) MINIMUM BELOW THE GRAB BAR.
<br />DI5PEN5ER5 SHALL NOT BE OF A TYPE THAT CONTROLS
<br />DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS PAPER
<br />FLOW.
<br />IIB-604.q.7 TOILET COMPARTMENTS. TOILET COMPARTMENTS
<br />SHALL COMPLY WITH SECTION IIB-604.8.
<br />II5-605 URINALS
<br />116-605.2 HE16HT AND DEPTH. URINALS SHALL BE THE
<br />STALL -TYPE OR THE WALL -HUNG TYPE WITH THE RIM 11 INCHES
<br />(432 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
<br />URINALS SHALL BE 13 1/2" INCHES (343 MY) DEEP MINIMUM
<br />MEASURED FROM THE OUTER FACE OF THE URINAL RIM TO
<br />THE BACK OF THE FIXTURE.
<br />II5-605.3 CLEAR FLOOR SPACE. A CLEAR FLOOR OR
<br />GROUND SPACE COMPLYING WITH SECTION II5-305
<br />P051TIONED FOR FORWARD APPROACH SHALL BE PROVIDED.
<br />IIB-605.4 FLUSH CONTROLS. FLUSH GONTROL5 SHALL BE
<br />HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH
<br />CONTROLS SHALL COMPLY WITH SECTION II5-301 EXCEPT
<br />THAT THE FLUSH CONTROL SHALL BE MOUNTED AT A MAXIMUM
<br />HEIGHT OF 44 INCHES (1 118 MM) ABOVE THE FIN 15H FLOOR.
<br />II6-606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE
<br />COMPLYING WITH SECTION II5-305, P051TIONED FOR A
<br />FORWARD APPROACH, AND KNEE AND TOE CLEARANCE
<br />COMPLYING WITH SECTION IIB-306 SHALL BE PROVIDED.
<br />EXCEPTIONS:
<br />1. A PARALLEL APPROACH COMPLYING WITH SECTION II5-305
<br />SHALL BE PERMITTED TO A KITCHEN SINK IN A SPACE WHERE
<br />A GOOK TOP OR CONVENTIONAL RANGE 15 NOT PRO VIDED
<br />AND TO NET BARS.
<br />2. RESERVED.
<br />3. IN RESIDENTIAL DWELLING UNITS, GABINETRY SHALL BE
<br />PERMITTED UNDER LAVATORIES AND KITCHEN SINKS
<br />PROVIDED THAT ALL OF THE FOLLOWING CONDITIONS ARE
<br />MET:
<br />(A) THE GA51NETRY CAN BE REMOVED WITHOUT REMOVAL OR
<br />REPLACEMENT OF THE FIXTURE;
<br />(5) THE FINISH FLOOR EXTENDS UNDER THE GABINETRY; AND
<br />(G) THE HALLS BEHIND AND SURROUNDING THE CABINETRY
<br />ARE FINISHED.
<br />4. A KNEE CLEARANCE OF 24 INCHES (610 MM) MINIMUM
<br />ABOVE THE FIN 15H FLOOR OR GROUND SHALL BE PERMITTED
<br />AT LAVATORIES AND SINKS USED PRIMARILY BY CHILDREN 6
<br />THROUGH 12 YEARS WHERE THE RIM OR COUNTER SURFACE IS
<br />31 INGHE5 (787 MM) MAXIMUM ABOVE THE F I N 15H FLOOR OR
<br />GROUND.
<br />5. A PARALLEL APPROACH COMPLYING WITH SECTION IIB-305
<br />SHALL BE PERMITTED TO LAVATORIES AND SINKS USED
<br />PRIMARILY BY CHILDREN 5 YEARS AND YOUNGER.
<br />6. THE DIP OF THE OVERFLOW SHALL NOT BE CONSIDERED IN
<br />DETERMINING KNEE AND TOE CLEARANCES.
<br />7. NO MORE THAN ONE BOWL OF A MULTI BOWL SINK SHALL
<br />BE REQUIRED TO PROVIDE KNEE AND TOE CLEARANCE
<br />COMPLYING WITH SECTION IIB-306.
<br />I I6-606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE
<br />INSTALLED WITH THE FRONT OF THE H16HER OF THE RIM OR
<br />COUNTER SURFACE 34 INCHES (864 MM) MAXIMUM ABOVE THE
<br />F I N I5H FLOOR OR GROUND.
<br />EXCEPTIONS:
<br />1. RESERVED.
<br />2. IN RESIDENTIAL DWELLING UNIT KITCHENS, SINKS THAT ARE
<br />ADJUSTABLE TO VARIABLE HEIGHTS, 21 INCHES (131 MM)
<br />MINIMUM AND 36 INCHES (q14 MM) MAXIMUM, SHALL BE
<br />PERMITTED WHERE ROU6H-IN PLUMBING PERMITS
<br />GONNEGTIONS OF SUPPLY AND DRAIN PIPES FOR 51NK5
<br />MOUNTED AT THE HE16HT OF 21 INCHES (731 MM).
<br />IIB-606.4 FAUGET5. CONTROLS FOR FAUCETS SHALL COMPLY
<br />WITH SECTION IIB-301. HAND -OPERATED METERING FAUCETS
<br />SHALL REMAIN OPEN FOR 10 SECONDS MINIMUM.
<br />IIB-606.5 EXPOSED PIPES AND SURFACES. WATER SUPPLY
<br />AND DRAIN PIPES UNDER LAVATORIES AND 5INK5 SHALL BE
<br />INSULATED OR OTHERWISE GONF16URED TO PROTECT AGAINST
<br />CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE
<br />SURFACES UNDER LAVATORIES AND SINKS.
<br />IIB-606.6 ADJAGENT SIDE WALL OR PARTITION. LAVATORIES,
<br />WHEN LOCATED ADJACENT TO A 51DE WALL OR PARTITION,
<br />SHALL BE A MINI MUM OF 18 INCHES (457 MM) TO THE
<br />GENTERLINE OF THE FIXTURE.
<br />5-606.1 SINK DEPTH. WHERE A FORWARD APPROACH IS
<br />REQUIRED AT A SINK, KNEE AND TOE CLEARANCE SHALL BE
<br />PROVIDED IN GOMPLIANGE WITH SECTION II5-306.
<br />B-601 BATHTUBS
<br />IIB-601.1 GENERAL. BATHTUBS SHALL COMPLY WITH SECTION
<br />B-601.
<br />116-601.2 CLEARANCE. CLEARANCE IN FRONT OF BATHTUBS
<br />SHALL EXTEND THE LENGTH OF THE BATHTUB AND SHALL BE
<br />48 INCHES (121q MM) WIDE MINIMUM FOR FORWARD APPROACH
<br />AND 30 INCHES (162 MY) WIDE MINIMUM FOR PARALLEL
<br />APPROACH. A LAVATORY GOM PLYING WITH 5EGTION IIBa606
<br />SHALL BE PERMITTED AT THE CONTROL END OF THE
<br />CLEARANCE. WHERE A PERMANENT SEAT 15 PROVIDED AT
<br />THE HEAD END OF THE BATHTUB, THE CLEARANCE SHALL
<br />EXTEND 12 INCHES (305 MM) MINIMUM BEYOND THE WALL AT
<br />THE HEAD END OF THE BATHTUB.
<br />IIB-605 SHOWER COMPARTMENTS
<br />IIB-608.1 GENERAL. SHOWER COMPARTMENTS SHALL COMPLY
<br />WITH SECTION IIB-608.
<br />IIB-608.2 51ZE AND CLEARANCES FOR SHOWER
<br />COMPARTMENTS.
<br />5HOWER COMPARTMENTS SHALL HAVE 51 ZE5 AND
<br />GLEARANGE5 COMPLYING WITH 5EGTION 15=608.2.
<br />IIB-608.2.1 TRANSFER TYPE 5HOWER COMPARTMENTS.
<br />TRANSFER TYPE SHOWER GOMPARTMENT5 SHALL BE 36
<br />INCHES (114 MM) BY 36 INCHES (q 14 MM) CLEAR INSIDE
<br />D I MEN51 ON5 MEASURED AT THE CENTER POINTS OF OPPOSING
<br />SIDES AND SHALL HAVE A 36-INGH (114 MY) WIDE MINIMUM
<br />ENTRY ON THE FACE OF THE SHOWER COMPARTMENT.
<br />CLEARANCE OF 36 INCHES (114 MM) WIDE MINIMUM BY 48
<br />INGHE5 (1211 MM)
<br />LONG MINIMUM MEASURED FROM THE CONTROL WALL SHALL
<br />BE PROVIDED. TRANSFER TYPE SHOWER COMPARTMENTS
<br />SHALL BE PERMITTED IN TRANSIENT LODGING GUEST ROOMS,
<br />MULTI BEDROOM HOUSING UNITS IN UNDERGRADUATE STUDENT
<br />HOUSING AND RESIDENTIAL DWELL I N6 UNITS; AND SHALL NOT
<br />BE PERMITTED AT OTHER LOCATIONS TO MEET THE
<br />REQUIREMENTS OF SECTION 11 3-213.3.6.
<br />5-608.2.2 STANDARD ROLL -IN TYPE SHOWER
<br />COMPARTMENTS. STANDARD ROLL -IN TYPE SHOWER
<br />COMPARTMENTS SHALL BE 30 INGHE5 (162 MM) WIDE MINIMUM
<br />BY 60 INCHES (1524 MM) DEEP MINIMUM CLEAR I N51 DE
<br />DIMENSIONS MEASURED AT CENTER POINTS OF OPP051 N6
<br />SIDES WITH A FULL OPENING WIDTH ON THE LONG SIDE.
<br />II5-608.2.2.1 CLEARANCE. A 36 INCH (114 MM) WIDE MINIMUM
<br />BY 60 INCH (1524 MM) LONG MINIMUM CLEARANCE SHALL BE
<br />PROVIDED ADJACENT TO THE OPEN FAGS OF THE SHOWER
<br />COMPARTMENT.
<br />I5-605.2.3 ALTERNATE ROLL -IN TYPE SHOWER
<br />COMPARTMENTS. ALTERNATE ROLL -IN TYPE SHOWER
<br />COMPARTMENTS SHALL BE 36 INCHES (114 MM) WIDE AND 60
<br />INCHES (1524 MM) DEEP MINIMUM CLEAR IN51DE DIMENSIONS
<br />MEASURED AT CENTER POINTS, OF OPPOSING SIDES. A 36
<br />NCH (114 MM) WIDE MINIMUM ENTRY SHALL BE PROVIDED AT
<br />ONE END OF THE LONG SIDE OF THE COMPARTMENT.
<br />IIB-608.3 GRAB BARS. GRAB BARS SHALL COMPLY WITH
<br />SECTION IIB-601 AND SHALL BE PROVIDED IN ACCORDANCE
<br />WITH SECTION II5-608.3. WHERE MULTIPLE GRAB BARS ARE
<br />USED, REQUIRED HORIZONTAL GRAB BARS SHALL BE
<br />INSTALLED AT THE SAME HE16HT ABOVE THE FIN 15H FLOOR.
<br />WHERE SEPARATE GRAB 5AR5 ARE REQUIRED ON ADJACENT
<br />WALL5 AT A COMMON MOUNTING HEIGHT, AN L-SHAPED OR
<br />U-SHAPED GRAB BAR MEETING THE DIMENSIONAL
<br />REQUIREMENTS OF SECTION IIB-608.3.2 OR II5-608.3.3 SHALL
<br />BE PERMITTED.
<br />EXCEPTIONS:
<br />I. RESERVED.
<br />2. IN RE51 DENTI AL DWELL I N6 UNITS, GRAB BARS SHALL NOT
<br />BE REQUIRED TO BE INSTALLED IN SHOWERS LOCATED IN
<br />BATHING FACILITIES PROVIDED THAT REINFORGEMENT HAS
<br />BEEN INSTALLED IN HALLS AND LOCATED 50 A5 TO PERMIT
<br />THE INSTALLATION OF GRAB BARS COMPLYING WITH SECTION
<br />B-608.3.
<br />I5-608.3.1 TRANSFER TYPE SHOWER COMPARTMENTS. IN
<br />TRANSFER TYPE COMPARTMENTS, GRAB BARS SHALL BE
<br />PROVIDED ACROSS THE CONTROL WALL AND BACK WALL TO
<br />A POINT l8 INCHES (451 MM) FROM THE CONTROL WALL.
<br />IIB-608.3.2 STANDARD ROLL -IN TYPE SHOWER
<br />COMPARTMENTS. GRAB BARS SHALL BE PROVIDED ON THE
<br />BACK WALL AND THE 51DE WALL OPPOSITE THE SEAT. GRAB
<br />BARS SHALL NOT BE PROVIDED ABOVE THE SEAT. GRAB
<br />5AR5 SHALL BE INSTALLED 6 INGHE5 (752 MM) MAXIMUM
<br />FROM ADJACENT HALLS.
<br />5-608.3.3 ALTERNATE ROLL -IN TYPE SHOWER
<br />COMPARTMENTS. IN ALTERNATE ROLL -IN TYPE SHOWER
<br />COMPARTMENTS, GRAB BARS SHALL BE PROVIDED ON THE
<br />BACK WALL AND THE 51DE WALL FARTHEST FROM THE
<br />COMPARTMENT ENTRY. GRAB BARS SHALL NOT BE PROVIDED
<br />ABOVE THE SEAT. GRAB BARS SHALL BE INSTALLED 6
<br />INGHE5 (152 MM) MAXIMUM FROM ADJACENT WALLS.
<br />IS-608.4 SEATS. A FOLDING SEAT SHALL BE PROVIDED IN
<br />ROLL -IN TYPE SHOWERS AND TRANSFER TYPE SHOWER
<br />COMPARTMENTS. SEATS SHALL COMPLY WITH SECTION
<br />IIB-610.
<br />EXCEPTION: IN RE51DENTIAL DWELLING UNITS, SEATS SHALL
<br />NOT BE REQUIRED IN SHOWER GOMPARTMENTS PROVIDED
<br />THAT REINFORCEMENT HAS BEEN INSTALLED IN WALL5 50 A5
<br />TO PERMIT THE INSTALLATION OF 5EAT5 COMPLYING WITH
<br />SECTION IIB-608.4.
<br />II6-608.5 CONTROLS. CONTROLS, FAUCETS, AND SHOWER
<br />SPRAY UNITS SHALL COMPLY WITH SECTION II6-301.4.
<br />CONTROLS AND FAUCETS SHALL ALLOW THE USER TO CLOSE
<br />AND OPEN THE WATER SUPPLY.
<br />I5-608.5.1 TRANSFER TYPE SHOWER COMPARTMENTS. IN
<br />TRANSFER TYPE SHOWER GOMPARTMENT5, THE GONTROL5,
<br />FAUCETS, AND SHOWER SPRAY UNIT SHALL BE INSTALLED ON
<br />THE SIDE WALL OPPOSITE THE SEAT 38 INCHES (165 MM)
<br />MINIMUM AND 48 INCHES (1211 MM) MAXIMUM ABOVE THE
<br />5HOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL
<br />WALL 15 INCHES (380 MM) MAXIMUM FROM THE GENTERLINE OF
<br />THE SEAT TOWARD THE SHOWER OPENING.
<br />I5-605.5.2 STANDARD ROLL -IN TYPE SHOWER
<br />COMPARTMENTS. IN STANDARD ROLL -IN TYPE SHOWER
<br />COMPARTMENTS, OPERABLE PARTS OF CONTROLS AND
<br />FAUCETS SHALL BE INSTALLED ON THE BACK WALL OF THE
<br />COMPARTMENT ADJACENT TO THE SEAT WALL 11 INCHES (483
<br />MM) MINIMUM AND 21 INGHE5 06 MM) MAXIMUM FROM THE
<br />SEAT WALL. AND SHALL BE LOCATED ABOVE THE GRAB BAR,
<br />BUT NO H16HER THAN 48 INCHES (1211 MM) ABOVE THE
<br />SHOWER FLOOR, WITH THEIR GENTERLINE AT 31 INCHES (qq I
<br />MM) TO 41 INCHES (1041 MM) ABOVE THE SHOWER FLOOR.
<br />OPERABLE PARTS OF THE SHOWER SPRAY UNIT, I NGLUD I N6
<br />THE HANDLE, SHALL BE INSTALLED ON THE BACK WALL
<br />ADJACENT TO THE SEAT WALL 11 INCHES (483 MM) MINIMUM
<br />AND 27 INCHES 06 MM) MAXIMUM FROM THE SEAT WALL;
<br />AND SHALL BE LOCATED ABOVE THE GRAB BAR, BUT NO
<br />H16HER THAN 48 INCHES (1211 MM) ABOVE THE SHOWER
<br />FLOOR.
<br />IIB-608.5.3 ALTERNATE ROLL -IN TYPE SHOWER
<br />COMPARTMENTS. IN ALTERNATE ROLL -IN TYPE 5HOWER
<br />COMPARTMENTS, OPERABLE PARTS OF CONTROLS AND
<br />FAUCETS SHALL BE INSTALLED ON THE 51DE WALL OF THE
<br />COMPARTMENT ADJACENT TO THE SEAT WALL H INCHES
<br />(483 MM) MINIMUM AND 21 INGHES (686 MM) MAXIMUM F5Wa
<br />THE SEAT WALL; AND SHALL BE LOCATED ABOVE TH GRAB
<br />BAR, BUT NO H16HER THAN 48 INCHES (I211 MM) A50 E THE
<br />SHOWER FLOOR, WITH THEIR GENTERLINE AT 3q INCHES (qI I
<br />MY) TO 41 I NGHE5 (1041 MM) ABOVE THE SHOWER FLC OR.
<br />OPERABLE PARTS OF THE SHOWER SPRAY UNIT, INGL DIN6
<br />THE HANDLE, SHALL BE INSTALLED ON THE 51DE HAL OF H
<br />COMPARTMENT ADJACENT TO THE SEAT WALL 17 INC 4ES
<br />MY) MINI MUM AND I 1 INGHE5 (483 MM) MAXIMUM FR THE
<br />SEAT WALL OR ON THE BACK WALL OPPOSITE THE 5 AT 15
<br />INCHES (381 MY) MAXIMUM, LEFT OR RIGHT, OF THE
<br />GENTERLINE OF THE SEAT, AND SHALL BE LOCATED BOVE
<br />THE GRAB BAR, BUT NO H16HER THAN 48 INCHES (121 "a <
<br />ABOVE THE SHOWER FLOOR.
<br />5-608.6 SHOWER SPRAY UNIT AND WATER. A SHOW RD a t
<br />SPRAY UNIT WITH A HOSE 5q INCHES (14g1 MY) LONG MINIMUM
<br />THAT GAN BE USED BOTH A5 A FIXED -POSITION SHOVER
<br />HEAD AND A5 A HANDHELD SHOWER SHALL BE PROV1777-
<br />THE SHOWER SPRAY UNIT SHALL HAVE AN ON/OFF CONTROL
<br />WITH A NON -POSITIVE SHUT-OFF. IF AN ADJU5TABLE-HE16HT
<br />5HOWER HEAD ON A VERTICAL BAR 15 USED, THE BAR SHALL
<br />BE INSTALLED So AS NOT TO OBSTRUCT THE USE OF GRAB
<br />BARS. SHOWER SPRAY UNITS SHALL DELIVER WATER THAT 15
<br />120F (4qC) MAXIMUM.
<br />EXCEPTION: WHERE SUBJECT TO EXCESSIVE VANDALISM, TWO
<br />FIXED SHOWER HEADS SHALL BE PERMITTED INSTEAD OF A
<br />HANDHELD SPRAY UNIT IN FACILITIES THAT ARE NOT MEDIGAI
<br />CARE FACILITIES, LON6-TERM CARE FACILITIES, TRANSIENT
<br />LODGING GUEST ROOMS, OR RESIDENTIAL DWELLING UNITS.
<br />EACH SHOWER HEAD SHALL BE INSTALLED SO IT GAN BE
<br />OPERATED INDEPENDENTLY OF THE OTHER AND SHALL HAVE
<br />SWIVEL ANGLE ADJUSTMENTS, BOTH VERTICALLY AND
<br />HORIZONTALLY. ONE SHOWER HEAD SHALL BE LOCATED AT A
<br />HE16HT OF 48 INCHES (1211 MM) MAXIMUM ABOVE THE SHOWEF
<br />FIN 15H FLOOR.
<br />IIB-608.1 THRESHOLDS. THRESHOLDS IN ROLL -IN TYPE
<br />5HOWER COMPARTMENTS SHALL BE 1/2" INCH (12.1 MM) H16H
<br />MAXIMUM IN AGGORDANGE WITH SECTION II6-303. IN
<br />TRANSFER TYPE SHOWER COMPARTMENTS, THRESHOLDS 1/2"
<br />NCH (12.7 MM) H16H MAXIMUM SHALL BE BEVELED, ROUNDED,
<br />OR VERTICAL.
<br />II6-608.8 SHOWER ENCLOSURES. ENCLOSURES FOR 5HOWER
<br />GOMPARTMENT5 SHALL NOT OBSTRUCT GONTROL5, FAUCETS,
<br />AND SHOWER SPRAY UNITS OR OBSTRUCT TRANSFER FROM
<br />WHEELGHAIR5 ONTO SHOWER SEATS.
<br />II5-608.1 SHOWER FLOOR OR GROUND SURFACE. FLOOR OR
<br />GROUND SURFACES OF SHOWERS SHALL COMPLY WITH
<br />SECTION II5-302.1 AND SHALL BE SLOPED 1:48 MAXIMUM IN
<br />ANY DIRECTION. WHERE DRAINS ARE PROVIDED, GRATE
<br />OPENIN65 SHALL BE 1/4" INCH (6.4 MM) MAXIMUM AND FLUSH
<br />WITH THE FLOOR SURFACE.
<br />5=608.10 SOAP DISH. WHERE A SOAP DI5H 15 PROVIDED, IT
<br />SHALL BE LOCATED ON THE CONTROL WALL AT 40 INCHES
<br />(1016 MY) MAXIMUM ABOVE THE SHOWER FLOOR, ARID WITHIN
<br />THE REACH L I M I T5 FROM THE SEAT.
<br />II6-601.2 CROSS SECTION. GRAB BARS SHALL HAVE A
<br />GRO55 SECTION COMPLYING WITH SECTION I15-60q 2.1 OR
<br />115-60q 2.2.
<br />IIB-601.2.1 GIRGULAR GRO55 SECTION. GRAB BARS WITH
<br />CIRCULAR GROSS SECTIONS SHALL HAVE AN OUT51 DE
<br />DIAMETER OF 1/4" INCHES (32 MY) MINIMUM AND 2 INCHES (51
<br />MM) MAXIMUM.
<br />II6-601.2.2 NON-GIRGULAR GROSS SECTION. GRAB BARS WIT
<br />NON-GIRGULAR GROSS SECTIONS SHALL HAVE A
<br />CR055-5EGTION DIMENSION OF 2 INCHES (51 MM) MAXIMUM
<br />AND A PERIMETER DIMENSION OF 4 INGHE5 (102 MM) MINIMUM
<br />AND 4.8 INCHES (122 MM) MAXIMUM.
<br />II6-60q 3 SPACING. THE SPACE BETWEEN THE WALL AND THE
<br />GRAB BAR SHALL BE 1/2" INCHES (38 MY). THE SPACE
<br />BETWEEN THE GRAB BAR AND PROJECTING OBJECTS BELOW
<br />AND AT THE EN05 SHALL BE 1/2" INCHES (38 MM) MINIMUM.
<br />THE 5PAGE BETWEEN THE GRAB BAR AND PROJECTING
<br />OBJECTS ABOVE SHALL BE 12 INGHE5 (305 MM) MINIMUM.
<br />IIB-60gA POSITION OF GRAB BARS. GRAB BARS SHALL BE
<br />INSTALLED IN A HORIZONTAL POSITION, 33 INGHE5 (838 MY)
<br />MINIMUM AND 36 INCHES (q14 MM) MAXIMUM ABOVE THE FIN&
<br />FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE,
<br />EXCEPT THAT AT WATER CLOSETS FOR CHILDREN'S USE
<br />COMPLYING WITH SECTION II5-604.1, GRAB BARS SHALL BE
<br />INSTALLED IN A HORIZONTAL P051 T I ON 18 INCHES (451 MM)
<br />MINIMUM AND 27 INCHES (686 MM) MAXIMUM ABOVE THE
<br />F I N I5H FLOOR MEASURED TO THE TOP OF THE 6R1 PP I N6
<br />SURFACE. THE HE16HT OF THE LOWER GRAB BAR ON THE
<br />BACK WALL OF A BATHTUB SHALL COMPLY WITH SECTION
<br />II6-601.4.1.1 OR II8=601.4.2.1.
<br />5-601.5 SURFACE HAZARDS. GRAB BARS AND ANY WALL
<br />OR OTHER SURFACES ADJACENT TO GRAB BARS SHALL BE
<br />FREE OF SHARP OR ABRASIVE ELEMENTS AND SHALL HAVE
<br />ROUNDED EDGES.
<br />IIB-60q.6 FITTINGS. GRAB BARS SHALL NOT ROTATE WITHIN
<br />THEIR FITTINGS.
<br />IIB-601.7 INSTALLATION. GRAB BARS SHALL BE INSTALLED I>
<br />ANY MANNER THAT PROVIDES A GRIPPING 5URFACE AT THE
<br />SPECIFIED LOCATIONS AND THAT DOES NOT OBSTRUCT THE
<br />REQUIRED CLEAR FLOOR SPACE.
<br />II5-60q.8 5TRUGTURAL STRENGTH. ALLOWABLE STRESSES
<br />SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A
<br />VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS (1112 N) 15
<br />APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER,
<br />MOUNTING DEVICE, OR SUPPORTING STRUCTURE.
<br />IIB-601.1 ALTERNATE CONFIGURATION. L-SHAPED OR
<br />U-SHAPED GRAB BARS SHALL BE PERMITTED.
<br />architecture & planning
<br />er4a- MITCHEL_L- N. SUITE 'C'
<br />IRVINE, CALIFORNIA 92614
<br />PHONE: (949)
<br />FAX: (949)
<br />752-1177
<br />rAIP PAKOJI S
<br />©KNITTER PARTNERS INTERNATIONAL
<br />ALL RIGHTS RESERVED 2025
<br />THIS DOCUMENT IS THE PROPERTY AND COPYRIGHT OF
<br />KNITTER PARTNERS INTERNATIONAL, INC. AND SHALL NOT BE
<br />USE ON ANY OTHER WORK, BE REPRODUCED OR DISCLOSED TO
<br />OTHERS EXCEPT BY WRITTEN AUTHORIZATION FROM KNITTER
<br />PARTNERS INTERNATIONAL., INC.
<br />1111117ma
<br />Oq-16-25
<br />Q
<br />Ey
<br />0
<br />U
<br />C7
<br />a
<br />InwvAI6,4E*]al
<br />m
<br />kn
<br />O
<br />N
<br />m
<br />PROJECT INFO
<br />GENERAL
<br />JOB NUMBER 24077
<br />PROJECT MGR. PB
<br />DRAWN BY 5TAFF
<br />PLOT DATE: 10-14-2025
<br />SHEET TITLE
<br />GENERAL NOTES
<br />SHEET NUMBER
<br />r�
<br />Cy
<br />
|