My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5306 W McFadden Ave - Plan
PBA
>
Building
>
ProjectDox
>
M
>
McFadden Ave
>
5306 W McFadden Ave
>
5306 W McFadden Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:50:47 AM
Creation date
2/24/2026 10:50:27 AM
Metadata
Fields
Template:
Plan
Permit Number
101122413
101122414
Full Address
5306 W McFadden Ave
Street Number
5306
Street Direction
W
Street Name
McFadden
Street Suffix
Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ST. BARBARA CATHOLIC SCHOOL TASK 2 75-24272-01 <br />DIOCESE OF ORANGE SEPTEMBER 12TH, 2024 <br />SANTA ANA, CA BID & PERMIT SET <br /> <br />QUALITY REQUIREMENTS 014000 - 2 <br />1. Use of trade-specific terminology in referring to a trade or entity does not require that <br />certain construction activities be performed by accredited or unionized individuals, or <br />that requirements specified apply exclusively to specific trade(s). <br />D. Mockups: Full-size physical assemblies that are constructed on-site either as freestanding <br />temporary built elements or as part of permanent construction. Mockups are constructed to <br />verify selections made under Sample submittals; to demonstrate aesthetic effects and qualities <br />of materials and execution; to review coordination, testing, or operation; to show interface <br />between dissimilar materials; and to demonstrate compliance with specified installation <br />tolerances. Mockups are not Samples. Unless otherwise indicated, approved mockups establish <br />the standard by which the Work will be judged. <br />1. Integrated Exterior Mockups: Mockups of the exterior envelope constructed on-site as <br />freestanding temporary built elements or as part of permanent construction, consisting of <br />multiple products, assemblies, and subassemblies. <br />E. Preconstruction Testing: Tests and inspections performed specifically for Project before <br />products and materials are incorporated into the Work, to verify performance or compliance <br />with specified criteria. <br />F. Product Tests: Tests and inspections that are performed by a nationally recognized testing <br />laboratory (NRTL) according to 29 CFR 1910.7, by a testing agency accredited according to <br />NIST's National Voluntary Laboratory Accreditation Program (NVLAP), or by a testing agency <br />qualified to conduct product testing and acceptable to authorities having jurisdiction, to <br />establish product performance and compliance with specified requirements. <br />G. Source Quality-Control Tests: Tests and inspections that are performed at the source; for <br />example, plant, mill, factory, or shop. <br />H. Testing Agency: An entity engaged to perform specific tests, inspections, or both. Testing <br />laboratory shall mean the same as testing agency. <br />I. Quality-Assurance Services: Activities, actions, and procedures performed before and during <br />execution of the Work to guard against defects and deficiencies and substantiate that proposed <br />construction will comply with requirements. <br />J. Quality-Control Services: Tests, inspections, procedures, and related actions during and after <br />execution of the Work to evaluate that actual products incorporated into the Work and <br />completed construction comply with requirements. Contractor's quality-control services do not <br />include contract administration activities performed by Architect or Construction Manager. <br />1.4 DELEGATED-DESIGN SERVICES <br />A. Performance and Design Criteria: Where professional design services or certifications by a <br />design professional are specifically required of Contractor by the Contract Documents, provide <br />products and systems complying with specific performance and design criteria indicated. <br />1. If criteria indicated are not sufficient to perform services or certification required, submit <br />a written request for additional information to Architect.
The URL can be used to link to this page
Your browser does not support the video tag.