My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5306 W McFadden Ave - Plan
PBA
>
Building
>
ProjectDox
>
M
>
McFadden Ave
>
5306 W McFadden Ave
>
5306 W McFadden Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:50:47 AM
Creation date
2/24/2026 10:50:27 AM
Metadata
Fields
Template:
Plan
Permit Number
101122413
101122414
Full Address
5306 W McFadden Ave
Street Number
5306
Street Direction
W
Street Name
McFadden
Street Suffix
Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ST. BARBARA CATHOLIC SCHOOL TASK 2 75-24272-01 <br />DIOCESE OF ORANGE SEPTEMBER 12TH, 2024 <br />SANTA ANA, CA BID & PERMIT SET <br /> <br />BASIC ELECTRICAL REQUIREMENTS 260100 - 6 <br />M. Excavation, Cutting and Patching: <br />1. Excavating, trenching and backfilling required for the work of this Division in <br />accordance with the applicable requirements of Division 31. Excavating and backfilling <br />connected with electrical work, repaving cuts and providing and maintaining protective <br />measures for the electrical work excavation required by the governing authorities having <br />jurisdiction shall be performed as a part of the work of this Division. <br />2. Verify openings indicated on the drawings. Provide all cutting, patching and <br />reinforcement of the construction of the building as required to install electrical work. <br />N. Tests <br />1. Equipment and systems for which the National Electrical Testing Association (NETA) <br />has an approved or recommended procedure, shall be tested in accordance with that <br />procedure. Test values shall equal values recommended by NETA. Copies of test reports <br />shall be submitted as required under shop drawing submittals. <br />2. Resistance to ground tests shall be accomplished by a qualified independent testing firm <br />to measure resistance to ground at grounding electrodes. Make tests before slabs or <br />affected areas are poured in order that corrective measures, if required, may be taken. <br />Submit a report showing the results of these measurements. If the resistances exceed <br />values specified elsewhere or NETA test procedure recommendations, perform corrective <br />measures required to reduce resistance to acceptable values. <br />3. Prior to energizing any motor, measure the service voltage for phase balance and report if <br />unbalance exceeds 1% from mean. <br />4. Measure the three-phase voltage at no load and at maximum load conditions and submit <br />to the engineer a report showing the results of these measurements. <br />5. Upon completion of the work and adjustment of all equipment, conduct an operating test. <br />Conduct the test in the presence of an authorized representative of the Architect. <br />Demonstrate system and equipment to operate in accordance with requirements of the <br />Contract Documents and to be free from electrical and mechanical defects. Provide <br />systems free from short circuits and grounds and show an insulation resistance between <br />phase conductors and ground not less than the requirements of the governing electric <br />code. Test circuits for proper neutral connection. <br />6. Complete tests prior to final inspection of project, including corrective work based on the <br />results of the tests. <br />7. Perform special tests on systems and equipment as specified herein using personnel <br />qualified to perform such tests. <br />O. Protection: Protect finish parts of the materials and equipment against damage during the <br />progress of the work and until final completion and acceptance. Cover materials and <br />equipment in storage and during construction in such a manner that no finished surfaces will be <br />damaged or marred. Keep moving parts clean, dry and lubricated. <br />P. Cleaning Up: <br />1. Upon completion of the work and at various time during the progress of the work, <br />remove from the building all surplus materials, rubbish and debris resulting from the <br />work of this Division. <br />2. Thoroughly clean switchgear including busses, apparatus, exposed conduit, metal work <br />including the exterior and interior, and accessories for the work of this Division, of
The URL can be used to link to this page
Your browser does not support the video tag.