My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
515 E Dyer Rd-Electrical Equipt - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Dyer Rd
>
515 E Dyer Rd
>
515 E Dyer Rd-Electrical Equipt - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:50:39 AM
Creation date
2/24/2026 10:50:27 AM
Metadata
Fields
Template:
Plan
Permit Number
101124055
Full Address
515 E Dyer Rd
Street Number
515
Street Direction
E
Street Name
Dyer
Street Suffix
Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
AMPERES <br />ABOVE <br />AIR CONDITIONING <br />ABOVE COUNTER TOP <br />ABOVE FINISHED FLOOR <br />ABOVE FINISHED GRADE <br />ALUMINUM <br />ARCHITECT <br />ABOVE SPLASH BLOCK <br />ABOVE SUSPENDED CEILING <br />ADJUSTABLE SPEED DRIVE <br />AUTOMATIC <br />AUXILIARY <br />AUTOMATIC TRANSFER SWITCH <br />AMERICAN WIRE GAUGE <br />BELOW FINISH FLOOR <br />BUILDING <br />BELOW FINISHED GRADE <br />CONDUIT <br />CIRCUIT BREAKER <br />CLOSED CIRCUIT TELEVISION <br />CIRCUIT <br />CEILING <br />COLUMN <br />COMBINATION <br />CONCRETE <br />CONSTRUCTION <br />DOWN FROM CEILING <br />DIAMETER <br />DOWN <br />DRAWING <br />EACH <br />ELECTRICAL CONTRACTOR <br />EXHAUST FAN <br />ELECTRIC / ELECTRICAL <br />EMERGENCY <br />ELECTRICAL METALLIC TUBING <br />EMERGENCY POWER OFF <br />EQUIPMENT <br />ELECTRIC WATER COOLER <br />EXISTING <br />EXTERIOR <br />FIRE ALARM <br />FIRE ALARM CONTROL PANEL <br />FLOOR/FLOORING <br />FIXTURE <br />GROUND <br />GENERAL CONTRACTOR <br />GENERAL DUTY <br />GENERATOR <br />GROUND FAULT INTERRUPT <br />HEAVY DUTY <br />HORSEPOWER <br />HEIGHT <br />HEATING/VENTILATING/AIR <br />CONDITIONING <br />HOT WATER <br />INSIDE DIAMETER <br />ISOLATED GROUND <br />INTERMEDIATE METAL <br />JUNCTION BOX <br />KILOVOLT-AMPERES <br />KILOWATTS <br />A <br />ABV <br />A/C <br />ACT <br />AFF <br />AFG <br />AL <br />ARCH <br />ASB <br />ASC <br />ASD <br />AUTO <br />AUX <br />ATS <br />AWG <br />BFF <br />BLDG <br />BFG <br />C <br />C/B <br />CCTV <br />CCT <br />CLG <br />COL <br />COMB <br />CONC <br />CONST <br />DFC <br />DIA <br />DN <br />DWG <br />EA <br />EC <br />EF <br />ELEC <br />EMER <br />EMT <br />EPO <br />EQUIP <br />EWC <br />EX <br />EXT <br />FA <br />FACP <br />FLR <br />FXTR <br />G <br />GC <br />GD <br />GEN <br />GFI <br />HD <br />HP <br />HT <br />HVAC <br />HW <br />ID <br />IG <br />IMT <br />J <br />KVA <br />KW <br />LTG <br />M <br />MC <br />MCB <br />MCC <br />MCM <br />MDP <br />MECH <br />MH <br />MIN <br />MISC <br />MLO <br />MSB <br />MTD <br />NEC <br />NEMA <br />NEUT <br />NF <br />NIC <br />NL <br />N.O. <br />N.C. <br />NO. <br />NTS <br />LIGHTING <br />METER <br />MECHANICAL CONTRACTOR <br />MAIN CIRCUIT BREAKER <br />MOTOR CONTROL CENTER <br />THOUSAND CIRCULAR MILS <br />MAIN DISTRIBUTION PANEL <br />MECHANICAL <br />MANHOLE <br />MINIMUM <br />MISCELLANEOUS <br />MAIN LUG ONLY <br />MAIN SWITCHBOARD <br />MOUNTED <br />NATIONAL ELECTRICAL CODE <br />NATIONAL ELECTRICAL <br />MANUFACTURERS ASSOCIATION <br />NEUTRAL <br />NON FUSED <br />NOT IN CONTRACT <br />NIGHT LIGHT <br />NORMALLY OPEN <br />NORMALLY CLOSED <br />NUMBER <br />NOT TO SCALE <br />ELECTRICAL ABBREVIATIONS <br />THOUSAND CIRCULAR MILSKCMIL <br />AMP FUSEDAF <br />OD <br />OFCI <br />OH <br />OUTSIDE DIAMETER <br />OWNER FURNISHED CONTRACTOR <br />INSTALLED <br />OVERHEAD <br />UNDERWRITER'S LABORATORIES <br />PVC <br />RECPT <br />RE: <br />REQD <br />RGS <br />RM <br />SCH <br />SPEC <br />SVC <br />TEL <br />TS <br />TYP <br />TTB <br />UG <br />UL <br />UNO <br />XFMR <br />POLYVINYL CHLORIDE <br />RECEPTACLE <br />REFERENCE/REFER TO <br />REQUIRED <br />RIGID GALVANIZED STEEL <br />ROOM <br />SCHEDULE <br />SPECIFICATIONS <br />SERVICE <br />TELEPHONE <br />TRANSFER SWITCH <br />TYPICAL <br />TELEPHONE TERMINAL BOARD <br />UNDERGROUND <br />UNLESS NOTED OTHERWISE <br />TRANSFORMER <br />TR TAMPER RESISTANT <br />W <br />W/ <br />W/O <br />WP <br />WATTS <br />WITH <br />WITHOUT <br />WEATHER PROOF <br />WR WEATHER RESISTANT <br />UP UNDERGROUND PRIMARY <br />V <br />VA <br />VOLTS <br />VOLT - AMPERES <br />US UNDERGROUND SECONDARY <br />PNL PANEL <br />POC POINT OF CONNECTION <br />PF <br />PH <br />PL <br />POWER FACTOR <br />PHASE <br />PROPERTY LINE <br />PM PRIMARY METER <br />PME PAD-MOUNTED ENCLOSURE <br />REMARKS <br />POWER DISTRIBUTION SYMBOL SCHEDULE <br />ALL SYMBOLS DO NOT NECESSARILY APPEAR ON THESE DRAW INGS <br />DESCRIPTIONSYMBOL <br />HOMERUN - TO CIRCUIT NO. 1,3,5 ON PANEL 'A' <br />BRANCH CIRCUIT OR CONDUIT UNDER FLOOR <br />BRANCH CIRCUIT OR CONDUIT EXPOSED AND/OR SURFACE MOUNTED <br />A-1,3,5 <br />FEEDER TAG. RE: ELECTRICAL FEEDER SCHEDULE FOR CONDUIT AND WIRE SIZE.B100 <br />JUNCTION BOX <br />FUSE <br />DISCONNECT SWITCH <br />ABOVE GROUND JUNCTION BOX <br />SWITCHBOARD / DISTRIBUTION PANELBOARD, REFER TO SWITCHBOARD <br />SCHEDULE OR RISER DIAGRAM <br />J <br />MOTOR <br />SPD SURGE PROTECTIVE DEVICE. <br />EXISTING TO REMAIN BRANCH CIRCUIT OR CONDUIT UNDER FLOOR <br />ALL BRANCH CIRCUITS WITH AN OVERALL LENGTH IN EXCESS OF 75 FEET SHALL BE INCREASED IN <br />WIRE SIZE TO ACCOMMODATE VOLTAGE DROP, INCLUDING EQUIPMENT GROUNDING CONDUCTOR. <br />ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO OWNER PROVIDED EQUIPMENT. <br />ALL JUNCTION BOXES SHALL BE ACCESSIBLE FOR FUTURE SERVICE PER CEC. <br />CONTRACTOR SHALL VISIT SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS, DETERMINE <br />THE EXTENT OF DEMOLITION REQUIRED TO FACILITATE NEW CONSTRUCTION AND INCLUDE ALL SUCH <br />WORK IN HIS BID. NO ADDITIONAL FUNDS WILL BE AUTHORIZED FOR ANY EXTRA WORK OR MATERIAL <br />NECESSARY DUE TO THE FAILURE OF THE CONTRACTOR TO FAMILIARIZE THEMSELVES WITH THE <br />EXISTING CONDITIONS OR FOR LACK OF COORDINATION BETWEEN TRADES. <br />PVC CONDUIT SHALL ONLY BE USED UNDERGROUND WITH PLASTIC COATED OR WRAPPED RIGID STEEL <br />CONDUIT ELBOWS. <br />DRAWINGS ARE SCHEMATIC IN NATURE AND MAY NOT BE DRAWN EXACTLY TO SCALE. CONTRACTOR <br />IS RESPONSIBLE FOR COORDINATING EXACT ROUTING OF ALL SERVICES WITH EXISTING CONDITIONS <br />AND ALL OTHER TRADES TO AVOID SPACING OR ROUTING PROBLEMS. <br />ALL CIRCUITS SHALL INCLUDE A GREEN GROUND CONDUCTOR SIZED IN ACCORDANCE WITH CEC <br />250.122, UNLESS NOTED OTHERWISE. <br />CONTRACTOR SHALL PROVIDE ACCURATE PANEL SCHEDULES. SCHEDULES SHALL INDICATE <br />DEVICES AND/OR EQUIPMENT SERVED, LOCATION AND/OR ROOM NUMBERS. <br />ELECTRICAL CONTRACTOR SHALL COMPLY WITH 2022 EDITION OF THE CALIFORNIA ELECTRICAL CODE <br />AND LOCAL CODES. <br />ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO MINIMIZE CONFLICTS. <br />ALL WIRE AND CABLE SIZES ARE FOR COPPER, UNLESS NOTED OTHERWISE AS ALUMINUM. <br />NO CONDUCTOR SHALL BE LOADED BEYOND ITS ALLOWABLE AMPACITY. <br />CONFIRM WITH LOCAL CODES, MECHANICAL CONTRACTOR AND EQUIPMENT VENDORS ON THE <br />LOCATION AND MOUNTING METHOD FOR DISCONNECT SWITCHES, MANUAL MOTOR STARTERS, <br />COMBINATION STARTER/DISCONNECTS, ETC. PRIOR TO ELECTRICAL ROUGH-IN AND INSTALLATION. <br />ELECTRICAL CONTRACTOR SHALL DOUBLE CHECK ALL FEEDER CONDUCTOR AND CONDUIT SIZES <br />WITH CEC AND LOCAL CODES PRIOR TO BID, ORDERING OR CUTTING CONDUCTORS. <br />UNLESS NOTED OTHERWISE, BRANCH CIRCUIT CONDUCTORS FOR CIRCUITS LESS THAN 600V SHALL BE <br />COPPER (XHHW OR EQUAL) SIZED AS FOLLOWS: <br />GENERAL ELECTRICAL NOTES <br />12. <br />13. <br />11. <br />9 <br />10. <br />8. <br />6. <br />7. <br />5. <br />4. <br />3. <br />2. <br />1. <br />14. <br />BREAKER RATING WIRE SIZE BREAKER RATING WIRE SIZE <br />15 AMP <br />20 AMP <br />30 AMP <br />40 AMP <br />50 AMP <br />60 AMP <br />70 AMP <br />80 AMP <br />90 AMP <br />100 AMP <br />#12 AWG <br />#12 AWG <br />#10 AWG <br />#8 AWG <br />#6 AWG <br />#4 AWG <br />#4 AWG <br />#3 AWG <br />#2 AWG <br />#1 AWG <br />WHERE TIGHTENING TORQUE IS INDICATED AS A NUMERIC VALUE OR IN INSTALLATION INSTRUCTIONS <br />PROVIDED BY THE MANUFACTURER, A CALIBRATED TORQUE TOOL SHALL BE USED TO ACHIEVE THE <br />INDICATED VALUE, UNLESS THE EQUIPMENT MANUFACTURER HAS PROVIDED INSTALLATION <br />INSTRUCTIONS FOR AN ALTERNATIVE METHOD OF ACHIEVING THE REQUIRED TORQUE. CONTRACTOR <br />SHALL PROVIDE A LETTER TO THE ELECTRICAL INSPECTOR STATING THAT ALL ELECTRICAL EQUIPMENT <br />HAS BEEN TORQUED ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS. <br />15. <br />CONTRACTOR SHALL COORDINATE AND RECEIVE APPROVAL FROM THE ORANGE COUNTY FIRE <br />AUTHORITY (OCFA) FOR GENERATOR FUEL STORAGE AND REFUELING PRIOR TO ORDERING. <br />16. <br />1 <br />1 <br />CONDUCTOR SPLICING IS STRICTLY PROHIBITED, NO EXCEPTIONS.17. <br />SITE UTILITY SYMBOLS SCHEDULE <br />DESCRIPTION REMARKSSYMBOL <br />PAD MOUNT TRANSFORMER <br />EXISTING UTILITY COMPANY PAD MOUNT TRANSFORMER <br />UTILITY COMPANY PAD MOUNT SWITCHGEAR <br />EXISTING UTILITY COMPANY PAD MOUNT <br />SWITCHGEAR <br />UTILITY COMPANY OVERHEAD LINE POLE <br />EXISTING UTILITY COMPANY OVERHEAD LINE POLE <br />UNDERGROUND UTILITY MANHOLE <br />EXISTING UNDERGROUND UTILITY MANHOLE <br />UNDERGROUND PRIMARY DUCTBANK.UP <br />UNDERGROUND SECONDARY DUCTBANK.US <br />UNDERGROUND COMMUNICATIONS DUCTBANK.UC <br />EXISTING UNDERGROUND PRIMARY DUCTBANK.EUP <br />EXISTING UNDERGROUND SECONDARY DUCTBANK.EUS <br />EXISTING UNDERGROUND COMMUNICATIONS DUCTBANK.EUC <br />REMOVE UNDERGROUND PRIMARY DUCTBANK.DUP <br />REMOVE UNDERGROUND SECONDARY DUCTBANK.DUS <br />REMOVE UNDERGROUND COMMUNICATIONS DUCTBANK.DUC <br />ALL SYMBOLS DO NOT NECESSARILY APPEAR ON THESE DRAWINGS <br />THE GROUND FAULT PROTECTION SYSTEM SHALL BE PERFORMANCE TESTED WHEN INSTALLED ON SITE. TEST <br />SHALL BE CONDUCTED IN ACCORDANCE WITH INSTRUCTIONS PROVIDED AND ALL APPLICABLE LOCAL CODES. <br />A WRITTEN RECORD OF TEST SHALL BE MADE AVAILABLE TO ENGINEER, OWNER AND AHJ. <br />GROUND FAULT PROTECTION <br />PROJECTS <br />EV CHARGERS - NOT IN SCOPE OF WORK <br />FULL DESIGN <br />EVSG (SWITCHGEAR ONLY) - <br />CURRENT SCOPE OF WORK <br />EV CHARGER DATA <br />L2 CHARGERS <br />00 <br />119 2119 <br />119 119 2 <br />L2 STALLS L3 CHARGERS <br />0 0 <br />4 <br />4 <br />L3 STALLS <br />448 South Hill Street <br />Suite 1001 <br />Los Angeles, CA 90013 <br />Phone: 310-975-2061 <br />Reviewed By:Proj #: <br />140 Newport Center Drive, <br />Suite 100 <br />Newport Beach, CA 92660 <br />O: 949.478.8800 <br />www.kpff.com <br />KPFF <br />9/ <br />1 <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />2 <br />: <br />0 <br />8 <br />: <br />0 <br />0 <br /> <br />P <br />M <br /> <br />A <br />u <br />t <br />o <br />d <br />e <br />s <br />k <br /> <br />D <br />o <br />c <br />s <br />: <br />/ <br />/ <br />D <br />L <br />X <br />8 <br />/ <br />D <br />L <br />X <br />8 <br />_ <br />M <br />E <br />P <br />. <br />r <br />vt <br />EV0.01 <br />SYMBOLS, LEGENDS, <br />AND ABBREVIATIONS - <br />ELECTRICAL <br />DLX8_EVSG <br />515 E Dyer Rd, Santa Ana, CA 92707 <br />Owner <br />NM23.0003320.000 <br />1416 NW 46TH Street <br />Suite 105-138 <br />Seattle, WA 98107 <br />WWW.NELSONWORLDWIDE.COM <br />Phone: (206) 408-8501 <br />Nelco Architecture, Inc. <br />ELECTRICAL SHEET SCHEDULE <br />EV0.01 SYMBOLS, LEGENDS, AND ABBREVIATIONS - ELECTRICAL <br />EV1.00 SITE PLAN - DEMOLITION - ELECTRICAL <br />EV2.00 SITE PLAN - ELECTRICAL <br />EV6.00 DIAGRAMS & DETAILS - ELECTRICAL <br />EV6.01 ONE-LINE DIAGRAM - ELECTRICAL <br />EV7.00 SCHEDULES - ELECTRICAL <br />EV9.00 SPECIFICATIONS - ELECTRICAL <br />EV9.01 SPECIFICATIONS - ELECTRICAL <br />EV9.02 SPECIFICATIONS - ELECTRICAL <br />EV9.03 SPECIFICATIONS - ELECTRICAL <br />Issue: No: Date: <br />CD 30 2023/11/03 <br />CD 50 2024/05/22 <br />CD 90 2025/03/11 <br />Issue for Permit 2025/04/21 <br />Plan Check Repsonse 1 1 2025/09/19 <br />1 <br />9-24-2025
The URL can be used to link to this page
Your browser does not support the video tag.