Laserfiche WebLink
E <br />E <br />J <br />CBCB <br />CB <br />CABCAB <br />E <br />E <br />E <br />E <br />J <br />J <br />CBCB <br />J <br />CB <br />CABCAB <br />DEMOLITION KEYNOTES: <br />1. EXISTING UNDERGROUND PRIMARY. CONDUCTORS TO BE REMOVED <br />BY UTILITY AND CONDUIT TO BE ABANDONED IN PLACE. <br />CONTRACTOR TO VERIFY AND DEMOLISH ANY CONDUIT WITHIN <br />THE BOUNDS OF NEW EQUIPMENT TO BE INSTALLED. ABANDONED <br />CONDUIT SHALL BE CAPPED BY CONTRACTOR. <br />2. EXISTING UTILITY PAD-MOUNTED TRANSFORMER AND ASSOCIATED <br />CONDUCTORS TO BE REMOVED BY UTILITY. EXISTING PAD TO BE <br />REWORKED BY CONTRACTOR FOR REPLACEMENT TRANSFORMER. <br />3. APPROXIMATE ROUTING OF EXISTING UNDERGROUND SECONDARY <br />CONDUCTORS, TO BE REMOVED BY CONTRACTOR. AREA TO BE <br />REWORKED FOR NEW SECONDARY. <br />4. EXISTING CURRENT TRANSFORMER METER TO BE REMOVED. <br />COORDINATE REMOVAL WITH UTILITY. <br />5. PROVIDE A TAP ALONG THE EXISTING MAIN SWITCHBOARD BUS <br />FOR A TEMPORARY 400-AMPERE CONNECTION. <br />6. PROVIDE A TAP ALONG THE EXISTING MAIN SWITCHBOARD BUS <br />FOR A TEMPORARY 600-AMPERE CONNECTION. <br />7. PROVIDE FEEDER FOR TEMPORARY POWER CONNECTION. REFER TO <br />ONE-LINE DIAGRAM ON SHEET EV6.01 FOR SIZING AND <br />QUANTITIES. PROVIDE PROTECTION AND SUPPORT AS REQUIRED <br />BY CEC 590.4. <br />8. PROVIDE 480-VOLT, 3-PHASE, 4-WIRE, 320-KILOWATT, PORTABLE <br />GENERATOR FOR TEMPORARY POWER. PROVIDE WITH 400-AMPERE <br />OVERCURRENT PROTECTION. PROPOSED LOCATION, COORDINATE <br />EXACT LOCATION WITH OWNER. <br />9. PROVIDE 480-VOLT, 3-PHASE, 4-WIRE, 500-KILOWATT, PORTABLE <br />GENERATOR FOR TEMPORARY POWER. PROVIDE WITH 600-AMPERE <br />OVERCURRENT PROTECTION. PROPOSED LOCATION, COORDINATE <br />EXACT LOCATION WITH OWNER. <br />10. SEE SHEET C1.20 FOR ASSOCIATED WALL DEMOLITION. <br />11. APPROXIMATE LOCATION OF UNDERGROUND SECONDARY FEEDER <br />INTERCEPTION. REMOVE EXISTING CONDUCTORS FROM <br />TRANSFORMER TO ASSOCIATED SWITCHBOARD "MMA". <br />12. CONTRACTOR TO REMOVE EXCESS CONCRETE FROM EXISTING PULL <br />SECTION. REPAIR ENCLOSURE AS REQUIRED. <br />13. PROPOSED LOCATION OF THE REMOTE EMERGENCY STOP SWITCH. <br />FIELD COORDINATE EXACT LOCATION IN FIELD. <br />14. ALL TEMPORARY GENERATORS MUST BE PROVIDED WITH: <br />• A READILY-ACCESSIBLE DISCONNECT FOR THE TEMPORARY <br />CONDUCTORS FEEDING THE BUILDING PER CEC 590.4(E) & <br />702.12(A). <br />• OVERCURRENT PROTECTION AT THE GENERATOR FOR ALL <br />TEMPORARY UNGROUNDED SERVICE CONDUCTORS FEEDING <br />THE BUILDING. NO OVERCURRENT DEVICE SHALL BE INSERTED <br />IN A GROUNDED SERVICE CONDUCTOR EXCEPT A CIRCUIT <br />BREAKER THAT SIMULTANEOUSLY OPENS ALL CONDUCTORS OF <br />THE CIRCUIT PER CEC 230.90. <br />• PROVISIONS TO SHUT DOWN THE PRIME MOVER PER CEC <br />445.18(B). <br />• A REMOTE EMERGENCY SHUTDOWN SWITCH TO SHUT DOWN <br />THE PRIME MOVER PER CEC 445.18(C). <br />• A GROUNDED SYSTEM PER CEC 250.30(A). REFER TO THE <br />GENERATOR GROUNDING DETAIL ON SHEET EV6.00 FOR <br />ADDITIONAL INFORMATION. <br /># <br />DEMOLITION GENERAL NOTES: <br />1. THE ELECTRICAL SUBCONTRACTOR SHALL VERIFY LOCATION AND <br />QUANTITY OF ITEMS TO BE REMOVED. NO ALLOWANCE WILL BE <br />MADE BECAUSE OF THE ELECTRICAL SUBCONTRACTOR’S <br />UNFAMILIARITY WITH THESE DETAILS. <br />2. ALL SALVAGE WILL REMAIN THE PROPERTY OF THE OWNER AND <br />SHALL BE DELIVERED BY THE CONTRACTOR TO A LOCATION AS <br />DIRECTED. ANY SALVAGE NOT DESIRED BY THE OWNER SHALL <br />BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE <br />REMOVED FROM THE PREMISES. <br />3. ALL EQUIPMENT SCHEDULED FOR DEMOLITION SHALL HAVE THEIR <br />CIRCUITRY REMOVED BACK TO THE ASSOCIATED PROTECTIVE <br />DEVICE. THE PROTECTIVE DEVICE SHALL REMAIN AN INTEGRAL PART <br />OF THE PANELBOARD AND BE INDICATED ON THE PANEL DIRECTORY <br />AS A SPARE OR REUSED FOR NEW CIRCUITRY. ASSOCIATED <br />CIRCUITRY IS DEFINED AS ALL WIRE, CONDUIT, JUNCTION BOXES, <br />DEVICE BOXES, WIRING DEVICES, COVER PLATES, ETC. ASSOCIATED <br />WITH THE ITEM SCHEDULED FOR REMOVAL. CONDUIT FOR ITEMS <br />SCHEDULED FOR REMOVAL AND IN INACCESSIBLE AREAS SHALL BE <br />EMPTIED AND SEALED OR OTHERWISE TERMINATED IN A SAFE <br />MANNER ACCEPTABLE TO THE OWNER. <br />4. ELECTRICAL CIRCUITS WITH A PORTION OF THE LOAD REMOVED <br />SHALL HAVE THE REMOVED LOADS AND ASSOCIATED CIRCUITRY <br />TERMINATED IN SUCH A MANNER THAT ANY REMAINING LOAD <br />REMAINS ACTIVE AND IN FIRST-CLASS OPERATING CONDITION. <br />5. HOLES AND DAMAGED AREAS CAUSED BY REMOVAL OF ANY OF THE <br />ABOVE ITEMS AND WHICH ARE NOT CONCEALED BY NEW <br />CONSTRUCTION SHALL BE REPAIRED TO MATCH EXISTING SURFACES. <br />IN ADDITION, OPENINGS CREATED BY THE REMOVAL OF THESE <br />ITEMS THROUGH FIRE RESISTANT RATED WALLS SHALL BE FIRE <br />STOPPED. <br />6. WHERE CONDUIT AND CONDUCTORS ARE INDICATED TO BE <br />REMOVED, CONDUIT SHALL BE REMOVED TO POINT OF <br />CONCEALMENT AND WIRING REMOVED ENTIRELY. PROVIDE BLANK <br />COVERPLATES WHERE REQUIRED. <br />7. BLANK COVERPLATES AND ALL UNUSED OPENINGS IN BOXES, <br />RACEWAYS, AUXILIARY GUTTERS, CABINETS, EQUIPMENT CASES AND <br />HOUSINGS SHALL BE CLOSED TO AFFORD PROTECTION <br />SUBSTANTIALLY EQUIVALENT TO THE WALLS OF THE EQUIPMENT. <br />8. IF A CONDUIT RUN IS EXPOSED OR A SURFACE RACEWAY LEFT <br />WITHOUT A MOUNTING SURFACE DUE TO THE REMOVAL OF A <br />PARTITION, THE CONDUIT SHALL BE REROUTED AS ACCEPTABLE TO <br />THE OWNER. <br />9. ELECTRICAL EQUIPMENT OR DEVICES THAT ARE TO BE RELOCATED <br />BUT WERE DAMAGED WHEN REMOVED SHALL BE REPAIRED, <br />RESTORED OR NEW ONES PURCHASED TO THE APPROVAL OF THE <br />OWNER. THE CONTRACTOR SHALL NOTIFY THE OWNER/ENGINEER OF <br />ANY ELECTRICAL EQUIPMENT OR DEVICES WHICH ARE INDICATED AS <br />RELOCATED BUT ARE FOUND TO BE UNUSABLE. <br />1 <br />EXISTING <br />WAREHOUSE <br />BUILDING <br />EAST DYER ROAD <br />HA <br />L <br />L <br />A <br />D <br />A <br />Y <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />EV1.00 <br />2 <br />EXISTING <br />PARKING <br />BUILDING <br />1 <br />EU <br />S <br />2 <br />3 <br />4 <br />7 <br />DUS <br />3 <br />EXISTING UTILITY <br />(SCE) P.O.C. <br />EAST DYER ROAD <br />DUS <br />4 <br />DUS <br />DU <br />S <br />DUS <br />EXISTING PARKING BUILDING <br />EXISTING EXTERIOR "MSB" PULL SECTION <br />8 <br />9 <br />EXISTING SWITCHBOARD "MMA" <br />EXISTING SWITCHBOARD "MSB"6 <br />5 <br />ELECTRICAL ROOM -S008 <br />EXISTING DISTRIBUTION <br />BOARD "DB" <br />10 <br />EU <br />S <br />11 <br />12 <br />14 <br />14 <br />1 <br />1 <br />13 1 <br />12 <br />448 South Hill Street <br />Suite 1001 <br />Los Angeles, CA 90013 <br />Phone: 310-975-2061 <br />NORTH <br />Reviewed By:Proj #: <br />140 Newport Center Drive, <br />Suite 100 <br />Newport Beach, CA 92660 <br />O: 949.478.8800 <br />www.kpff.com <br />KPFF <br />9/ <br />1 <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />2 <br />: <br />0 <br />9 <br />: <br />4 <br />1 <br /> <br />P <br />M <br /> <br />A <br />u <br />t <br />o <br />d <br />e <br />s <br />k <br /> <br />D <br />o <br />c <br />s <br />: <br />/ <br />/ <br />D <br />L <br />X <br />8 <br />/ <br />D <br />L <br />X <br />8 <br />_ <br />M <br />E <br />P <br />. <br />r <br />vt <br />EV1.00 <br />SITE PLAN - <br />DEMOLITION - <br />ELECTRICAL <br />DLX8_EVSG <br />515 E Dyer Rd, Santa Ana, CA 92707 <br />Owner <br />NM23.0003320.000 <br />1416 NW 46TH Street <br />Suite 105-138 <br />Seattle, WA 98107 <br />WWW.NELSONWORLDWIDE.COM <br />Phone: (206) 408-8501 <br />Nelco Architecture, Inc. <br />0 60' 120'30'15' <br />0 20' 40'10' <br />1" =60'-0" <br />1" =20'-0" <br />1" = 60'-0"EV1.00 <br />1 SITE PLAN - DEMOLITION - ELECTRICAL <br />1" = 20'-0"EV1.00 <br />2 ENLARGED SITE PLAN - DEMOLITION - ELECTRICAL <br />M <br />M <br />NOT TO SCALEEV1.00 <br />3 EXISTING EXTERIOR "MSB" PULL SECTION <br />Issue: No: Date: <br />CD 30 2023/11/03 <br />CD 50 2024/05/22 <br />CD 90 2025/03/11 <br />Issue for Permit 2025/04/21 <br />Plan Check Repsonse 1 1 2025/09/19 <br />9-24-2025