My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
515 E Dyer Rd-Electrical Equipt - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Dyer Rd
>
515 E Dyer Rd
>
515 E Dyer Rd-Electrical Equipt - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:50:39 AM
Creation date
2/24/2026 10:50:27 AM
Metadata
Fields
Template:
Plan
Permit Number
101124055
Full Address
515 E Dyer Rd
Street Number
515
Street Direction
E
Street Name
Dyer
Street Suffix
Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
J <br />CBCB <br />CB <br />CABCAB <br />E <br />E <br />E 6071150 <br />N 2205450 <br />E <br />J <br />J <br />CBCB <br />J <br />CB <br />CABCAB <br />E <br />E <br />E <br />E 6071150 <br />KEYNOTES: <br />1. PROVIDE ONE 5" CONDUIT WITH PULL STRING FOR PRIMARY <br />CABLES (CABLES FURNISHED AND INSTALLED BY UTILITY). <br />MINIMUM BURIAL DEPTH SHALL BE 48" BELOW FINISHED GRADE. <br />CONDUIT SHALL BE CAPPED BY CONTRACTOR. <br />2. PROPOSED ROUTING OF NEW UNDERGROUND CONDUCTORS. <br />REFER TO ONE-LINE DIAGRAM ON SHEET EV6.01 FOR SIZING AND <br />QUANTITIES. <br />3. PROVIDE ROUGH-IN PROVISIONS FROM MAIN SWITCHGEAR. ONE <br />(1) SIX-INCH CONDUIT FROM EACH SPARE SECTION OF THE <br />SWITCHGEAR. <br />4. LOCATION OF NEW CONDUIT STUB. CONTRACTOR TO STUB OUT 5' <br />HORIZONTALLY FROM EDGE OF NEW EQUIPMENT. <br />5. PROVIDE ROUGH-IN PROVISIONS FROM MAIN SWITCHGEAR. <br />PROVIDE ONE (1) SIX-INCH CONDUIT, WITH PULL STRING, FROM <br />SPARE SECTION OF THE SWITCHGEAR. APPROXIMATE LOCATION OF <br />CONDUIT STUB SHOWN. CONTRACTOR TO CONFIRM FINAL <br />LOCATION WITH THE OWNER DURING CONSTRUCTION. <br />6. BOLLARDS WITHIN EQUIPMENT WORKING SPACE TO BE <br />REMOVABLE TYPE. <br />7. APPROXIMATE LOCATION OF UNDERGROUND SECONDARY FEEDER <br />INTERCEPTION. EXTEND EXISTING CONDUIT FROM INTERCEPTION <br />POINT TO REPLACEMENT TRANSFORMER LOCATION. PROVIDE NEW <br />CONDUCTORS, DO NOT SPLICE. UTILIZE EXISTING CONDUITS AS <br />APPLICABLE. CONTRACTOR TO FIELD VERIFY CONDUIT QUANTITIES <br />AND SIZES. SEE ONE-LINE FOR ADDITIONAL INFORMATION. <br /># <br />GENERAL NOTES: <br />1. THE ELECTRICAL CONTRACTOR COORDINATE EXACT EQUIPMENT <br />LOCATIONS WITH CIVIL AND STRUCTURAL DRAWINGS PRIOR WORK. <br />1 <br />EXISTING <br />WAREHOUSE <br />BUILDING <br />EAST DYER ROAD <br />HA <br />L <br />L <br />A <br />D <br />A <br />Y <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />EV2.00 <br />2 <br />EXISTING <br />PARKING <br />BUILDING <br />'DLX8-MVSG-1' <br />EAST DYER ROAD <br />4 <br />'DLX8-XFMR-BLDG' <br />EXISTING PARKING BUILDING <br />1 <br />ELECTRICAL ROOM -S008 <br />EXISTING EXTERIOR "MSB" PULL SECTION <br />2 <br />3 <br />2 <br />EXISTING DISTRIBUTION <br />BOARD "DB" <br />EXISTING SWITCHBOARD "MMA" <br />EXISTING SWITCHBOARD "MSB" <br />6(TYPICAL) <br />2 <br />US <br />US <br />US <br />UP <br />UTILITY (SCE) PAD MOUNTED <br />EQUIPMENT (P.O.C.) (10'X14' PAD) <br />UNDER SEPERATE PERMIT AND <br />NOT UNDER SCOPE OF WORK. <br />UPUP <br />'DLX8-MV-UMC' <br />EU <br />S <br />EU <br />S <br />US <br />7 <br />5 <br />448 South Hill Street <br />Suite 1001 <br />Los Angeles, CA 90013 <br />Phone: 310-975-2061 <br />NORTH <br />Reviewed By:Proj #: <br />140 Newport Center Drive, <br />Suite 100 <br />Newport Beach, CA 92660 <br />O: 949.478.8800 <br />www.kpff.com <br />KPFF <br />9/ <br />1 <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />2 <br />: <br />0 <br />8 <br />: <br />0 <br />2 <br /> <br />P <br />M <br /> <br />A <br />u <br />t <br />o <br />d <br />e <br />s <br />k <br /> <br />D <br />o <br />c <br />s <br />: <br />/ <br />/ <br />D <br />L <br />X <br />8 <br />/ <br />D <br />L <br />X <br />8 <br />_ <br />M <br />E <br />P <br />. <br />r <br />vt <br />EV2.00 <br />SITE PLAN - <br />ELECTRICAL <br />DLX8_EVSG <br />515 E Dyer Rd, Santa Ana, CA 92707 <br />Owner <br />NM23.0003320.000 <br />1" = 60'-0"EV2.00 <br />1 SITE PLAN - ELECTRICAL <br />1416 NW 46TH Street <br />Suite 105-138 <br />Seattle, WA 98107 <br />WWW.NELSONWORLDWIDE.COM <br />Phone: (206) 408-8501 <br />Nelco Architecture, Inc. <br />0 60' 120'30'15' <br />1" = 20'-0"EV2.00 <br />2 ENLARGED SITE PLAN - ELECTRICAL <br />0 20' 40'10' <br />1" =60'-0" <br />1" =20'-0" <br />Issue: No: Date: <br />CD 30 2023/11/03 <br />CD 50 2024/05/22 <br />CD 90 2025/03/11 <br />Issue for Permit 2025/04/21 <br />Plan Check Repsonse 1 1 2025/09/19 <br />9-24-2025
The URL can be used to link to this page
Your browser does not support the video tag.