WD PROJ. #DRAWN BY:CHECKED DATE <br />23411 JA EG/SH <br />WESTGROUP DESIGNS, INC.© <br />ISSUED FOR: <br />REGISTRATION/SIGNATURE: <br />SHEET TITLE: <br />SHEET NUMBER: <br />S1.00 <br />REVISIONS: <br />02/19/25 <br />STRUCTURAL NOTES <br />AND ABBREVIATIONS <br />No.3503 <br />L <br />I <br />GNE <br />L <br />S NO <br />B A <br />LAE <br />A LI OFRNIA <br />N <br />E <br />ER <br />I <br />E <br />ET <br />ORPD <br />F E <br />R IR <br />L.KC <br />E <br />TS <br />AT <br />CFO <br />RE <br />G <br />S <br />I <br />S <br />URALTSRUCTPRO <br />G <br />R <br />E <br />S <br />S <br /> <br />- <br />NO <br />T <br /> <br />F <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br />REV <br />I <br />E <br />W <br />H: <br />\ <br />2 <br />0 <br />2 <br />3 <br />\ <br />2 <br />3 <br />0 <br />2 <br />2 <br />1 <br />\ <br />3 <br />_ <br />D <br />r <br />a <br />w <br />i <br />n <br />g <br />s <br />\ <br />D <br />w <br />g <br />s <br />- <br />0 <br />0 <br />\ <br />2 <br />3 <br />- <br />0 <br />2 <br />2 <br />1 <br />- <br />0 <br />0 <br />_ <br />S <br />1 <br />. <br />0 <br />0 <br /> <br />S <br />T <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br /> <br />N <br />O <br />T <br />E <br />S <br /> <br />A <br />N <br />D <br /> <br />A <br />B <br />B <br />R <br />E <br />V <br />I <br />A <br />T <br />I <br />O <br />N <br />S <br />. <br />d <br />w <br />g <br /> <br /> <br /> <br /> <br />P <br />L <br />O <br />T <br />T <br />E <br />D <br /> <br />B <br />Y <br />: <br /> <br /> <br />Ch <br />a <br />n <br />n <br />o <br />n <br /> <br />S <br />h <br />i <br />d <br />a <br />k <br />i <br /> <br /> <br /> <br /> <br />O <br />N <br />: <br /> <br /> <br />Ma <br />r <br />c <br />h <br /> <br />2 <br />4 <br />, <br /> <br />2 <br />0 <br />2 <br />5 <br />BEWLEY STREET <br />RESIDENCE <br />ILLUMINATION <br />FOUNDATION <br />918 BEWLEY STREET, <br />SANTA ANA, CA 92703 <br />LONG BEACH • SAN DIEGO <br />Project: <br />LONG BEACH OFFICE <br />3900 Cover Street, Long Beach <br />CA 90808 • 562.985.3200 <br />S T R U C T U R A L E N G I N SREE <br />23-0221-00 <br />02/19/251 DELTA 1 <br />02/19/25CITY APPROVAL <br />03/24/252 DELTA 2 <br />STEEL COLUMN STARTING AT THIS LEVEL. WHERE NO <br />COLUMN TYPE IS INDICATED, COLUMN CONTINUES <br />FROM LEVEL BELOW.W8x45 <br />HSS6 <br />x <br />6 <br />x <br />3 <br />/ <br />8 <br />HD1 HOLDOWN ANCHOR TYPE AS NOTEDHD9 <br />SHEAR WALL PANEL, HOLDOWN TYPE, AND <br />MINIMUM LENGTH AT THIS LEVEL PER TYPICAL <br />SHEAR WALL ELEVATION <br />A <br />10' <br />SYMBOL DESCRIPTION <br />PLAN SYMBOLS <br />W12x25 BEAM SIZE AND SPAN <br />B1 BEAM SPAN, SIZE PER SCHEDULE <br />OPENINGS IN FLOOR OR ROOF PER ARCHITECTURAL <br />OR MECHANICAL DRAWINGS <br />2x12 <br />RJ1 <br />WOOD JOIST FRAMING SPAN, SIZE PER PLAN OR <br />APPLICABLE SCHEDULE <br />FJ1 <br />TOP OF PLYWOOD SHEATHING <br />TOS <br />21'-0" <br />SEISMIC/ WIND DRAG STRAP <br />6x6 <br />WOOD POST STARTING AT THIS LEVEL PER POST <br />SCHEDULE <br />WOOD HEADER, SIZE PER SCHEDULE <br />SYMBOL DESCRIPTION <br />PLAN SYMBOLS <br />SYMBOLS <br />#POUND, NUMBER, QUANTITY <br />@ AT <br /><LESS THAN <br />>GREATER THAN <br />±PLUS OR MINUS <br />°DEGREE <br />Ø DIAMETER <br />ABBREVIATIONS <br />AB ANCHOR BOLT <br />ADDL ADDITIONAL <br />ANCH ANCHOR, ANCHORAGE <br />APPROX APPROXIMATE, APPROXIMATELY <br />ARCH ARCHITECT, ARCHITECTURAL <br />BLDG BUILDING <br />BLKG BLOCKING, BLOCK <br />BM BEAM <br />BN BOUNDARY NAIL <br />BOT BOTTOM <br />BS BOUNDARY SCREW <br />CALCS CALCULATIONS <br />CANT CANTILEVER <br />CG CENTER OF GRAVITY <br />CIP CAST IN PLACE <br />CL CENTERLINE <br />CLR CLEAR, CLEARANCE <br />CMU CONCRETE MASONRY UNIT <br />COL COLUMN <br />CONC CONCRETE <br />CONN CONNECT, CONNECTION <br />CONT CONTINUOUS <br />CJP COMPLETE JOINT PENETRATION <br />D PENNY (NAIL SIZE) <br />DBL DOUBLE <br />DET DETAIL <br />DIA DIAMETER <br />DIAG DIAGONAL <br />DIM DIMENSION <br />DIST DISTANCE <br />DO DITTO <br />DWG DRAWING <br />(E)EXISTING <br />EA EACH <br />EF EACH FACE <br />ELEC ELECTRICAL <br />ELEV ELEVATION, ELEVATOR <br />EMB EMBED, EMBEDDED, EMBEDMENT <br />EMBED EMBED, EMBEDDED, EMBEDMENT <br />EN EDGE NAIL <br />EQ EQUAL <br />EQUIP EQUIPMENT <br />ES EDGE SCREW, EACH SIDE <br />EW EACH WAY <br />FDN FOUNDATION <br />FIN FINISH <br />FLR FLOOR <br />FN FIELD NAIL <br />F/O FACE OF <br />FS FIELD SCREW <br />FTG FOOTING <br />GA GAUGE <br />GALV GALVANIZE <br />GLB GLUED-LAMINATED BEAM <br />GR GRADE <br />HD HOLDOWN <br />HDR HEADER <br />HEX HEXAGONAL <br />HT HEIGHT <br />HORIZ HORIZONTAL <br />I/F INSIDE FACE <br />INFO INFORMATION <br />INSP INSPECTION <br />JST JOIST <br />JT JOINT <br />K KIPS (1000#) <br />KB-TZ2 HILTI KWIK BOLT TZ2 (ANCHOR) <br />LBS POUNDS <br />LD DEVELOPMENT LENGTH <br />LDH HOOK DEVELOPMENT LENGTH <br />LLH LONG LEG HORIZONTAL <br />LLV LONG LEG VERTICAL <br />LOCS LOCATIONS <br />LONG LONGITUDINAL <br />LS LAP SPLICE LENGTH <br />LVL LAMINATED VENEER LUMBER <br />LTWT LIGHT-WEIGHT <br />LWT LIGHT-WEIGHT <br />MANUF MANUFACTURER <br />MAX MAXIMUM <br />MECH MECHANICAL <br />MFR MANUFACTURER <br />MHP MHP STRUCTURAL ENGINEERS <br />MIN MINIMUM <br />MISC MISCELLANEOUS <br />(N)NEW <br />N/A NOT APPLICABLE <br />NTS NOT TO SCALE <br />NWT NORMAL-WEIGHT <br />O/F OUTSIDE FACE <br />OC ON CENTER <br />OH OPPOSITE HAND <br />OP OPERATING <br />OPER OPERATING <br />OPP OPPOSITE, OPPOSITE HAND <br />PARA PARALLEL <br />PERP PERPENDICULAR <br />PL PLATE, PROPERTY LINE <br />PLY PLYWOOD <br />PJP PARTIAL JOINT PENETRATION <br />PSL PARALLAM <br />PT POST-TENSIONED (CONCRETE) <br />PT PRESSURE-TREATED (WOOD) <br />QTY QUANTITY <br />R RADIUS <br />RAD RADIUS <br />REF REFER TO, REFERENCE <br />REINF REINFORCING <br />REQD REQUIRE, REQUIRED <br />SCHED SCHEDULE <br />SECT SECTION <br />SEOR STRUCTURAL ENGINEER OF RECORD <br />SHT SHEET <br />SHTG SHEATHING <br />SIM SIMILAR <br />SIMP SIMPSON STRONG-TIE COMPANY <br />SMS SHEET METAL SCREW <br />SOG SLAB-ON-GRADE <br />SQ SQUARE <br />STAGG STAGGER <br />STD STANDARD <br />STIFF STIFFEN, STIFFENER <br />STIRR STIRRUP <br />STRUC STRUCTURAL <br />SW SHEAR WALL <br />SYM SYMMETRICAL <br />T&B TOP & BOTTOM <br />TBD TO BE DETERMINED <br />THK THICK, THICKNESS <br />THRU THROUGH <br />TN TOE NAIL <br />T/O TOP OF <br />TRANS TRANSVERSE <br />TS TUBE STEEL <br />TYP TYPICAL <br />UNO UNLESS NOTED OTHERWISE <br />VERT VERTICAL <br />VIF VERIFY IN FIELD <br />W/WITH <br />W/O WITHOUT <br />WP WORK POINT <br />WT WEIGHT <br />STRUCTURAL STEEL SHAPES <br />CX STANDARD CHANNEL <br />HSS HOLLOW STRUCTURAL SECTIONS <br />LX ANGLE <br />MCX MISCELLANEOUS CHANNEL <br />STD PIPE STANDARD PIPE (SCHED 40) <br />WTX, STX STRUCTURAL TEES <br />WX W SHAPES <br />X-STRG EXTRA STRONG PIPE <br />XX-STRG DBL EXTRA STRONG PIPE <br />ABBREVIATIONS: <br />CODES/INSTITUTIONS/ASSOCIATIONS <br />ACI AMERICAN CONCRETE INSTITUTE <br />AF&PA (NDS) AMERICAN FOREST & PAPER ASSOCIATION (NDS) <br />AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION <br />AISI AMERICAN IRON AND STEEL INSTITUTE <br />APA-EWA APA-ENGINEERED WOOD ASSOCIATION <br />ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS <br />ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS <br />AWS AMERICAN WELDING SOCIETY <br />CBC CALIFORNIA BUILDING CODE <br />CRSI CONCRETE REINFORCING STEEL INSTITUTE <br />DSA DIVISION OF THE STATE ARCHITECT <br />HCAI DEPARTMENT OF HEALTH CARE ACCESS AND INFORMATION <br />IBC INTERNATIONAL BUILDING CODE <br />NDS NATIONAL DESIGN SPECIFICATIONS <br />SDI STEEL DECK INSTITUTE <br />SJI STEEL JOIST INSTITUTE <br />SSMA STEEL STUD MANUFACTURERS ASSOCIATION <br />GENERAL STRUCTURAL NOTES: <br />1.DESIGN CRITERIA: THE FOLLOWING DESIGN PARAMETERS HAVE BEEN USED IN THE DESIGN OF THE STRUCTURAL, AND <br />WHERE APPLICABLE, NON-STRUCTURAL SYSTEMS REPRESENTED IN THESE STRUCTURAL DRAWINGS. <br />A.CODE OF RECORD: 2022 EDITION, CALIFORNIA BUILDING CODE <br />B.AUTHORITY HAVING JURISDICTION:CITY OF ORANGE <br />(REFERENCE TO THE “AUTHORITY HAVING JURISDICTION” OR “GOVERNING AGENCY” THROUGHOUT THESE <br />STRUCTURAL DRAWINGS SHALL BE CONSIDERED TO BE THE AUTHORITY LISTED ABOVE.) <br />C.DESIGN LOADS (VERTICAL/GRAVITY): <br />·ROOF:DL: 15 PSF LL: 20 PSF <br />·STAIR:DL: 10 PSF LL: 60 PSF <br />THESE LOAD VALUES REPRESENT THE ANTICIPATED DEAD LOADS AND ALLOWABLE SUPERIMPOSED LIVE LOADS <br />FOR WHICH THE STRUCTURE HAS BEEN DESIGNED, ASSUMING THE NOTED MATERIALS STRENGTHS ARE ACHIEVED <br />AND THE STRUCTURE HAS BEEN FULLY ERECTED AND SECURED. MINOR ADJUSTMENTS MAY HAVE BEEN USED FOR <br />SPECIAL DESIGN CASES WHERE MORE REFINED VALUES ARE REQUIRED. <br />D.BUILDING RISK CATEGORY: <br />·MAIN BUILDING: II <br />E.WIND DESIGN PARAMETERS: <br />·ULTIMATE (LFRD) DESIGN WIND SPEED (V 3 SEC. GUST):95 MPH <br />·WIND DIRECTIONALITY FACTOR, (KD):1.0 <br />·EXPOSURE CATEGORY:B <br />·TOPOGRAPHIC FACTOR, (KZT):1.0 <br />·GUST EFFECT FACTOR:0.85 <br />·ENCLOSURE CLASSIFICATION:ENCLOSED <br />·INTERNAL PRESSURE COEFFICIENT, (GCPI):+/- 0.18 <br />·ULTIMATE DESIGN WIND PRESSURE: <br />§MWFRS: 18 PSF <br />F.SEISMIC DESIGN PARAMETERS: <br />·SEISMIC SITE CLASS:D (DEFAULT) <br />·SITE COEFFICIENTS, SPECTRAL ACCELERATION PARAMETERS: <br />§SS: 1.324 <br />§S1: 0.471 <br />·DESIGN SPECTRAL ACCELERATION PARAMETERS: <br />§SDS: 1.059 <br />§SD1: 0.574 <br />·SEISMIC IMPORTANCE FACTOR:1.0 <br />·SEISMIC DESIGN CATEGORY:D <br />MAIN BUILDING <br />G.SEISMIC DESIGN PARAMETERS: <br />·BASIC SEISMIC FORCE-RESISTING SYSTEM:LIGHT-FRAME SHEARWALLS WITH STRUCTURAL <br />RATED PLYWOOD PANELS <br />·RESPONSE MODIFICATION COEFFICIENT, (R):6.5 <br />·OVER-STRENGTH FACTOR, (Ω0):3 <br />·DEFLECTION AMPLIFICATION FACTOR, (CD): 4 <br />·ANALYSIS PROCEDURE:EQUIVALENT LATERAL FORCE <br />·SEISMIC BASE SHEAR COEFFICIENT, (CS, I.E. %G):0.163 <br />2.ASTM DESIGNATIONS, ICC REPORT REFERENCES, AND ALL STANDARDS AND REFERENCED DOCUMENTS SHALL REFER TO <br />THE LATEST EDITIONS AND/OR AMENDMENTS AS ADOPTED BY THE CODE OF RECORD. <br />3.GENERAL NOTES AND TYPICAL DETAILS SHALL APPLY TO ALL PARTS OF THE PROJECT. WHERE SPECIFIC DETAILS ARE <br />NOT PROVIDED, THE GENERAL NOTES AND TYPICAL DETAILS SHALL GOVERN. HOWEVER, WHEN A SPECIFIC DETAIL OR <br />NOTE HAS BEEN PROVIDED, REFERENCED OR CALLED OUT ON PLAN, THAT DETAIL OR NOTE SHALL GOVERN FOR THE <br />SPECIFIC CASE. IN ADDITION, WHEN A DETAIL IS REFERENCED AS SIMILAR (SIM) TO A SPECIFIC DETAIL, OR WHEN IT CAN <br />BE REASONABLY INFERRED THAT A SITUATION IS SIMILAR TO A SPECIFIC DETAIL, THAT SPECIFIC DETAIL SHALL BE <br />ASSUMED TO APPLY UNTIL OTHERWISE DIRECTED BY THE ENGINEER OF RECORD. <br />4.THESE STRUCTURAL DRAWINGS ARE AN INTEGRAL PART OF, AND RELIANT ON, INFORMATION CONTAINED WITHIN THE <br />ENTIRE SET OF CONSTRUCTION DOCUMENTS PREPARED FOR THE PROJECT. AS SUCH, IT SHALL BE THE RESPONSIBILITY <br />OF THE CONTRACTOR AND SUBCONTRACTORS TO REVIEW AND COORDINATE INFORMATION CONTAINED IN THE <br />CIVIL/ARCH/M/E/P AND SPECIALTY CONSULTANT DRAWINGS AND SPECIFICATIONS TO ENSURE A FULL UNDERSTANDING <br />OF THE PROJECT REQUIREMENTS. ANY OMISSIONS AND/OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE <br />WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT <br />AND STRUCTURAL ENGINEER AND THE CONTRACTOR SHALL NOT PROCEED WITH THE AFFECTED WORK UNTIL <br />CLARIFICATION AND/OR DIRECTION HAS BEEN GIVEN. <br />5.PRIOR TO STARTING WORK ON THE PROJECT AND/OR ON A SPECIFIC AREA OF THE PROJECT, THE CONTRACTOR SHALL <br />CHECK ALL DIMENSIONS. DIMENSIONS NOT SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE COORDINATED FROM THE <br />ARCHITECTURAL AND OTHER CONSULTANT DRAWINGS. WHERE DIMENSIONS DIFFER BETWEEN PLANS, THE ARCHITECT <br />AND STRUCTURAL ENGINEER SHALL BE NOTIFIED AND THE CONTRACTOR SHALL NOT PROCEED WITH THE AFFECTED <br />WORK UNTIL DIRECTION HAS BEEN PROVIDED. WRITTEN DIMENSIONS SHALL GOVERN OVER SCALES SHOWN ON THE <br />PLANS. <br />6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES. THE ARCHITECTURAL AND <br />MEP DRAWINGS SHALL BE USED FOR THE SIZE AND LOCATION OF ALL OPENINGS (EXCEPT AS SPECIFICALLY <br />CONTROLLED BY THE STRUCTURAL DRAWINGS), INTERIOR NON-BEARING PARTITIONS, CONCRETE CURBS, SLOPES, <br />DEPRESSIONS, CHANGES IN LEVEL, FINISHES, CHAMFERS OR GROOVES, FLOOR AND ROOF DRAINS, INSERTS, SLEEVES, <br />PIPES, CONDUITS AND OTHER NON-STRUCTURAL ITEMS. <br />7.UNLESS SPECIFICALLY NOTED ON THE STRUCTURAL PLANS OR REFERENCED DETAILS, DO NOT PLACE MECHANICAL, <br />ELECTRICAL (INCLUDING LOW-VOLTAGE AV), AND PLUMBING (MEP) SLEEVES, PIPES, INSERTS OR CONDUIT IN OR <br />THROUGH STRUCTURAL MEMBERS, REGARDLESS OF MATERIAL, WITHOUT PRIOR APPROVAL AND DIRECTION BY THE <br />STRUCTURAL ENGINEER. EXCEPT AS SPECIFICALLY SHOWN ON PLAN, NO STRUCTURAL MEMBER (BEAM, COLUMN, SHEAR <br />WALL, STRUCTURAL SLAB, GRADE BEAM, BRACE, ETC.) SHALL BE CUT, DRILLED, OR NOTCHED WITHOUT PRIOR <br />AUTHORIZATION AND DIRECTION FROM THE STRUCTURAL ENGINEER AND AUTHORITY HAVING JURISDICTION. <br />8.ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST CURRENT <br />KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. WHERE THE ACTUAL CONDITIONS VARY FROM THAT SHOWN IN <br />THESE DRAWINGS, THEY SHALL BE REPORTED TO THE ARCHITECT AND STRUCTURAL ENGINEER SO THAT PROPER <br />CLARIFICATION OR REVISION MAY BE MADE. THE CONTRACTOR SHALL NOT PROCEED WITH THE AFFECTED WORK UNTIL <br />CLARIFICATION AND/OR DIRECTION HAS BEEN GIVEN. <br />9.THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE <br />METHOD OR SEQUENCE OF CONSTRUCTION, UNLESS SPECIFICALLY NOTED OTHERWISE. THE CONTRACTOR SHALL <br />SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, <br />TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING BUT NOT LIMITED TO BRACING, SHORING, AND LAY DOWN OF <br />MATERIALS. <br />10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DETERMINATION OF LOADS AND EVALUATION OF THE LOADING <br />EFFECTS ON THE STRUCTURE FROM TEMPORARY CONSTRUCTION CONDITIONS, INCLUDING FROM EQUIPMENT SUCH AS <br />SKIP LOADERS, SCISSOR LIFTS, ETC., FROM HORIZONTAL WIND AND SEISMIC FORCES IMPOSED DURING THE <br />CONSTRUCTION SCHEDULE, ALONG THE PATH-OF-TRAVEL FOR MOVING PERMANENT EQUIPMENT TO ITS FINAL LOCATION, <br />AND FROM TEMPORARY LOADING THAT MAY OCCUR DURING EQUIPMENT INSTALLATION. THE CONTRACTOR MAY USE THE <br />“DESIGN LOADS” INFORMATION PROVIDED IN NOTE #1 ABOVE WHEN CONSIDERING TEMPORARY CONSTRUCTION LOADING <br />CONDITIONS ON A COMPLETED RAISED FLOOR OR ROOF SYSTEM. <br />11.OBSERVATION VISITS TO THE SITE BY REPRESENTATIVES OF THE STRUCTURAL ENGINEER SHALL NOT BE DEEMED TO <br />INCLUDE INSPECTIONS OF THE PROTECTIVE MEASURES OR OF THE CONSTRUCTION PROCEDURES. OBSERVATION VISITS <br />AND CONSTRUCTION SUPPORT SERVICES ARE PROVIDED BY THE STRUCTURAL ENGINEER OR HIS/HER REPRESENTATIVE <br />SOLELY FOR THE PURPOSE OF ASSISTING THE OWNER IN QUALITY CONTROL AND IN ACHIEVING CONFORMANCE WITH <br />THE CONTRACT DOCUMENTS. THESE SUPPORT SERVICES SHALL NOT BE DEEMED TO PROVIDE A GUARANTEE OF THE <br />CONTRACTOR'S PERFORMANCE AND SHALL NOT BE CONSTRUCTED AS ACCEPTANCE OR SUPERVISION OF <br />CONSTRUCTION. <br />12.SUBMITTALS: <br />A.SHOP DRAWINGS AND SUBMITTALS, INCLUDING CONCRETE MIX DESIGNS, REQUIRED BY THE SPECIFICATIONS <br />AND/OR THESE DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW PRIOR TO <br />FABRICATION OR USE. A SCHEDULE FOR THE RELEASE OF SHOP DRAWINGS AND SUBMITTALS SHALL BE PREPARED <br />BY THE CONTRACTOR AND SUBMITTED TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO <br />THE FIRST SUBMITTAL. THIS SUBMITTAL SCHEDULE SHALL PROPORTION THE NUMBER OF SHOP DRAWINGS TO BE <br />REVIEWED IN EACH SUBMITTAL TO ALLOW SUFFICIENT TIME AS DEEMED REASONABLE IN THE PROFESSIONAL <br />JUDGMENT OF THE ARCHITECT AND STRUCTURAL ENGINEER TO PERMIT ADEQUATE REVIEW. MHP WILL <br />COORDINATE WITH THE ARCHITECT AND/OR CONTRACTOR TO ENSURE THAT THE SUBMITTAL SCHEDULE <br />PRIORITIZES THE REVIEW IN A MANNER CONSISTENT WITH THE ANTICIPATED CONSTRUCTION SEQUENCE. SHOP <br />DRAWINGS AND SUBMITTALS SHALL REFERENCE THE LATEST REVISION OF EACH STRUCTURAL DESIGN DRAWING <br />USED FROM WHICH TO DETAIL. SHOP DRAWINGS AND/OR SUBMITTALS THAT DO NOT IDENTIFY THE LATEST REVISION <br />OF THE STRUCTURAL DRAWINGS AND/OR DO NOT REFERENCE THE AGENCY APPROVED CONSTRUCTION <br />DOCUMENTS SHALL BE RETURNED FOR THE DETAILER TO UPDATE AND RESUBMIT. PARTIALLY COMPLETE SHOP <br />DRAWINGS AND SHOP DRAWINGS COMPLETED WITHOUT INCORPORATING THE INFORMATION PROVIDED IN <br />RESPONSE TO REQUESTS FOR INFORMATION (RFI/RFC) MAY BE RETURNED (AT MHP'S SOLE DISCRETION) FOR <br />UPDATING IF IT IS DETERMINED THAT SUCH INFORMATION WAS PROVIDED IN A TIMELY MANNER PRIOR TO THE <br />RELEASE OF THE SHOP DRAWING SUBMITTAL. IF A SUBMITTAL MUST BE REVISED, IT SHALL IDENTIFY EACH REVISION <br />AND/OR ADDITION TO EACH SHOP DRAWING BY CLOUDING OR OTHER MEANS. <br />B.SUBMITTALS, INCLUDING SHOP DRAWINGS, DEFERRED APPROVAL ITEMS, AND RFI/RFCS, WILL NOT BE ACCEPTED BY <br />MHP DIRECTLY FROM THE PROJECT SUB-CONTRACTORS. SUBMITTALS WILL BE ACCEPTED FROM THE OWNER'S <br />AUTHORIZED CONTRACT ADMINISTRATOR (I.E. GENERAL CONTRACTOR, CONSTRUCTION MANAGER, OR ARCHITECT) <br />ONLY AFTER THEY HAVE BEEN CONFIRMED TO COMPLY WITH CONTRACT SUBMITTAL REQUIREMENTS AND THE <br />REQUIREMENTS OF THE CONTRACT DOCUMENTS. THE OWNER'S AUTHORIZED CONTRACT ADMINISTRATOR SHALL <br />COORDINATE AND VERIFY COMPLIANCE WITH THE REQUIREMENTS OF THE PROJECT SPECIFICATIONS REGARDING <br />DISTRIBUTION OF THE SUBMITTALS TO AND THROUGH THE ARCHITECT'S OFFICE. <br />C.SUBMITTALS FOR DEFERRED APPROVAL ITEMS, SUCH AS (BUT NOT LIMITED TO) ELEVATORS AND CURTAIN WALLS, <br />SHALL INCLUDE CALCULATIONS, DETAILED PLANS AND SPECIFICATIONS FOR ALL ELEMENTS OF THE DEFERRED <br />SYSTEM INCLUDING, BUT NOT LIMITED TO, MEMBERS, SUPPORTING BRACKETS OR ATTACHMENTS, AND <br />ANCHORAGE. DEFERRED APPROVAL ITEM SUBMITTALS SHALL BE ISSUED TO THE ARCHITECT AND STRUCTURAL <br />ENGINEER OF RECORD FOR REVIEW AND VERIFICATION THAT THE PROPOSED SYSTEM DOES NOT NEGATIVELY <br />IMPACT NOR SUBSTANTIALLY CHANGE THE STRUCTURAL LOADS AND SUPPORT CONDITIONS FOR WHICH THE BASE <br />STRUCTURE WAS DESIGNED WITH ADEQUATE TIME TO ALLOW ANY REQUIRED CHANGES TO BE MADE BEFORE <br />FORMAL SUBMITTAL TO THE GOVERNING AGENCY. FOLLOWING VERIFICATION BY THE SEOR AND ARCHITECT, THE <br />MANUFACTURER OR CONTRACTOR SHALL SUBMIT THE CALCULATIONS, DETAILED PLANS, AND SPECIFICATIONS, <br />STAMPED AND SIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE PROJECT STATE, TO THE GOVERNING <br />AGENCY FOR APPROVAL. INSTALLATION OF DEFERRED ITEM ELEMENTS, SUCH AS GUIDE RAILS, MULLIONS, <br />SUPPORTING BRACKETS, AND/OR ITEMS CONTINGENT ON THE DEFERRED SUBMITTAL SHALL NOT BE STARTED UNTIL <br />THE DETAILED PLANS AND SPECIFICATIONS HAVE BEEN APPROVED BY THE GOVERNING AGENCY. <br />D.WHEN THE ALLOWANCE FOR SUBSTITUTION OF A SPECIFIED MATERIAL OR PRODUCT DESIGNATION IS IMPLIED <br />WITHIN THE CONSTRUCTION DOCUMENTS BY THE USE OF THE WORDS “ACCEPTED ALTERNATES”, “ALTERNATIVE <br />PRODUCTS/SUPPLIERS”, ETC. OR “OR APPROVED EQUAL”, A FORMAL SUBSTITUTION REQUEST SHALL BE SUBMITTED <br />BY THE GENERAL CONTRACTOR. THE FORMAL SUBSTITUTION REQUEST SHALL CLEARLY IDENTIFY THE ORIGINAL <br />PRODUCT AND THE REQUESTED SUBSTITUTE PRODUCT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING <br />THAT THE REQUESTED SUBSTITUTION IS “EQUAL” TO, OR BETTER THAN, THE ORIGINAL PRODUCT FOR ALL <br />CONSIDERATIONS SUCH AS, BUT NOT NECESSARILY LIMITED TO, STRENGTH, PERFORMANCE, AND INSTALLATION <br />VARIABLES, INCLUDING SCHEDULE. SUCH VERIFICATION SHALL BE CLEARLY OUTLINED IN THE FORMAL SUBMITTAL <br />AS A TABULAR COMPARISON BETWEEN THE ORIGINAL PRODUCT CRITERIA AND THE REQUESTED SUBSTITUTE'S <br />PRODUCT CRITERIA. APPROVAL OF THE SUBSTITUTION REQUEST SHALL BE OBTAINED FROM THE ARCHITECT, <br />STRUCTURAL ENGINEER OF RECORD AND, IF NECESSARY, THE GOVERNING AGENCY, PRIOR TO FABRICATION OR <br />INSTALLATION OF THE SUBSTITUTED MATERIAL OR PRODUCT. <br />FOUNDATIONS: <br />1.PRESUMPTIVE LOAD BEARING VALUES PER CBC TABLE 1806.2 WERE USED FOR THE STRUCTURAL DESIGN OF <br />FOUNDATIONS AND EARTH RETAINING ELEMENTS CONTAINED HEREIN. IF IT IS DETERMINED THAT ANY OF THE CODE <br />REQUIREMENTS ON WHICH THESE PRESUMPTIVE VALUES ARE BASED WILL NOT BE FOLLOWED DURING CONSTRUCTION, <br />A FORMAL CHANGE ORDER SHALL BE PREPARED WITH ADEQUATE TIME FOR PROCESSING APPROVAL BY THE SEOR AND <br />THE GOVERNING AGENCY. MHP, INC. ASSUMES NO RESPONSIBILITY FOR THE ACCURACY OR ADEQUACY OF THE <br />PRESUMPTIVE VALUES. <br />2.THE FOLLOWING DESIGN PARAMETERS WERE USED AS THE BASIS FOR ALLOWABLE FOUNDATION LOADS AND SOIL <br />PRESSURES: <br />A.ALLOWABLE SOIL BEARING PRESSURES: <br />§SPREAD/ISOLATED FOOTINGS: 1,500 PSF <br />§CONTINUOUS FOOTINGS: 1,500 PSF <br />§FOR LOAD COMBINATIONS INCLUDING WIND OR SEISMIC, ONE-THIRD (1/3) INCREASE IS ALLOWED. <br />B.RETAINED EARTH PRESSURES: <br />§EQUIVALENT FLUID PRESSURE (ACTIVE):45 PCF <br />§EQUIVALENT FLUID PRESSURE (AT REST):45 PCF <br />C.RESISTANCE TO SLIDING: <br />§FRICTION COEFFICIENT:0.25 X DEAD LOAD <br />§COHESION:130 PCF <br />§PASSIVE PRESSURE:100 PCF <br />§FOR LOAD COMBINATIONS INCLUDING WIND OR SEISMIC, ONE-THIRD (1/3) INCREASE ON PASSIVE PRESSURE IS <br />ALLOWED. <br />3.ALL SITE FILL AND BACKFILL SHALL BE COMPACTED TO 90% OF MAXIMUM DENSITY IN ACCORDANCE WITH THE PROJECT <br />SPECIFICATIONS, IF APPLICABLE AND ASTM TEST METHOD D-1557. FLOODING IS NOT PERMITTED AND SHALL NOT BE <br />USED FOR COMPACTION PURPOSES. <br />4.SPECIAL INSPECTION SHALL BE PERFORMED BY A SPECIAL INSPECTOR WITH THE APPROPRIATE REGIONAL EXPERIENCE <br />AND BACKGROUND KNOWLEDGE TO CONFIRM ADEQUATE PREPARATION AND COMPACTION OF THE UNDERLYING SOILS <br />HAS BEEN COMPLETED. THE SPECIAL INSPECTION SHALL TAKE PLACE PRIOR TO INSTALLATION OF REINFORCING OR <br />OTHER ELEMENTS WHICH MAKE THE EXCAVATIONS INACCESSIBLE FOR ANY CORRECTIVE WORK DEEMED NECESSARY <br />FOR APPROVAL. A COPY OF THE INSPECTION REPORT SHALL BE SUBMITTED TO THE SEOR PRIOR TO POURING <br />CONCRETE. IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION MAY BE REQUIRED. <br />5.WATER SHALL BE REMOVED FROM FOUNDATION EXCAVATION PRIOR TO PLACING OF CONCRETE. CARE SHALL BE TAKEN <br />TO AVOID DRYING OUT UNDERLYING NATURAL SOILS. <br />6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SEQUENCING AND SHORING, ETC., NECESSARY TO SUPPORT CUT <br />AND/OR FILL BANKS DURING EXCAVATION AND FORMING AND PLACEMENT OF CONCRETE. CARE SHALL BE TAKEN TO <br />AVOID DISTURBING SOILS AROUND AND/OR SUPPORTING EXISTING FOUNDATIONS AND UTILITIES. <br />7.SEE SPECIAL INSPECTION GENERAL NOTES FOR INSPECTION REQUIREMENTS. <br />REINFORCING STEEL: <br />1.DETAILING, FABRICATION AND PLACING OF REINFORCING STEEL SHALL CONFORM TO STANDARDS AND <br />RECOMMENDATIONS CONTAINED WITHIN THE CRSI “MANUAL OF STANDARD PRACTICE”. DETAILING FABRICATION AND <br />PLACING OF WELDED WIRE REINFORCING SHALL CONFORM TO THE STANDARDS AND RECOMMENDATIONS CONTAINED <br />WITHIN THE WRI “MANUAL OF STANDARD PRACTICE - STRUCTURAL WELDED WIRE REINFORCEMENT”. <br />2.REINFORCING BARS (REBAR), STEEL WELDED WIRE REINFORCING (WWR), AND TIE WIRE USED TO SECURE REBAR AND <br />WWR SHALL CONFORM TO THE FOLLOWING ASTM SPECIFICATIONS, UNO: <br />A.REINFORCING, (ALL BAR SIZES, UNO):ASTM A-615, GR 60 <br />B.REINFORCING BARS TO BE WELDED (ALL BAR SIZES UNO):ASTM A-706, GR 60 <br />C.WELD WIRE REINFORCING: ASTM A-1064 <br />D.TIE WIRE: ASTM A-82 <br />3.ALL REINFORCING STEEL SHALL BE BENT COLD. GRADE 60 BARS MAY ONLY BE BENT ONCE, STRAIGHTENING AND/OR <br />RE-BENDING IS NOT ALLOWED. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SEQUENCE PLACEMENT OF <br />REINFORCING SUCH THAT INCIDENTAL BENDING DOES NOT OCCUR. <br />4.PRIOR TO PLACING CONCRETE; REINFORCING STEEL, INCLUDING WWR, AND OTHER EMBEDDED ITEMS SHALL BE <br />WELL-SECURED IN POSITION AND SHALL BE CLEAN OF RUST, GREASE OR OTHER MATERIAL LIKELY TO IMPAIR BOND. <br />WHERE TWO LAYERS OF REINFORCING STEEL ARE REQUIRED (I.E. FOOTING PADS OR SLABS) PROVIDE APPROPRIATE <br />CHAIRS TIED TO AND SUPPORTED BY LOWER MAT OF REINFORCING TO SUPPORT THE UPPER MAT OF REINFORCING. <br />“HOOK AND PULL” METHODS SHALL NOT BE ALLOWED. <br />5.CONCRETE PROTECTION FOR REINFORCING BARS SHALL BE AT LEAST EQUAL TO THE DIAMETER OF THE BAR. MINIMUM <br />COVER FOR CAST IN PLACE CONCRETE SHALL BE AS FOLLOWS: <br />A.CAST AGAINST AND PERMANENTLY IN CONTACT WITH GROUND: <br />·ALL MEMBERS, ALL REINFORCEMENT: 3” <br />B.EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: <br />·ALL MEMBERS, #6 THROUGH #18 BARS: 2” <br />·ALL MEMBERS, #5, W31 OR D31 WIRE AND SMALLER 1 1/2” <br />C.NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: <br />·SLABS, JOISTS, WALLS; #14 AND #18 BARS:1 1/2” <br />·SLABS, JOISTS, WALLS; #11 BARS AND SMALLER: 3/4” <br />·BEAMS, COLUMNS; <br />PRIMARY REINF, STIRRUPS, TIES, SPIRALS AND HOOPS:1 1/2” <br />6.MINIMUM CLEAR SPACING BETWEEN PARALLEL BARS IN A SINGLE LAYER SHALL NOT BE LESS THAN 1 1/2”, 4/3 TIMES <br />LARGEST AGGREGATE, 1 1/2 TIMES DIAMETER OF THE LARGER BAR, WHICHEVER IS GREATER. WHERE PARALLEL <br />REINFORCING IS PLACED IN TWO OR MORE LAYERS, BARS IN THE UPPER LAYERS SHALL BE PLACED DIRECTLY ABOVE <br />THE BARS IN LOWER LAYERS WITH NOT LESS THAN 1” CLEAR SPACE BETWEEN LAYERS. <br />7.DEVELOPMENT AND LAP SPLICE LENGTHS FOR REINFORCING STEEL AND WELDED WIRE REINFORCING SHALL BE AS <br />NOTED ON PLANS AND DETAILS CONTAINED THEREIN. WHERE SPLICE LOCATIONS ARE NOT SPECIFICALLY INDICATED, <br />SPLICES SHALL BE STAGGERED A MINIMUM OF ONE (1) LAP LENGTH. WHERE SPECIFIC LAP LENGTH REQUIREMENTS ARE <br />NOT SPECIFICALLY SHOW ON PLANS, THE FOLLOWING MINIMUM LENGTHS SHALL BE USED: <br />A.REBAR IN CONCRETE: SEE TYPICAL DETAILS <br />B.REBAR IN MASONRY: SEE TYPICAL DETAILS <br />C.WWR IN CONCRETE: 1 1/2 X WIRE GRID SPACES (9” MIN) <br />8.COMPLETE REINFORCING PLACEMENT DRAWINGS (SHOP DRAWINGS) SHALL BE PREPARED IN ACCORDANCE WITH ACI 315 <br />AND SHALL BE SUBMITTED TO THE SEOR FOR REVIEW PRIOR TO FABRICATION. APPROVED SHOP DRAWINGS SHALL BE <br />MADE AVAILABLE ON THE JOB SITE PRIOR TO PLACING OF CONCRETE. SEE SUBMITTALS SECTION OF THE STRUCTURAL <br />NOTES FOR ADDITIONAL INFORMATION AND REQUIREMENTS. <br />9.CONTRACTOR SHALL SCHEDULE SPECIAL INSPECTIONS SO THAT BAR SIZE, SPACING, LAP SPLICE AND EMBEDMENT <br />LENGTH OF REINFORCING BARS, AND THE LOCATION OF CONDUIT, SLEEVES AND EMBEDDED ITEMS, MAY BE CORRECTED, <br />IF NECESSARY, PRIOR TO PLACEMENT OF OVERLYING GRIDS OF REINFORCING STEEL AND/OR PLACEMENT OF <br />CONCRETE. <br />CONCRETE: <br />1.ALL CONCRETE WORK SHALL CONFORM TO THE STANDARDS OF THE AMERICAN CONCRETE INSTITUTE (ACI), “ACI MANUAL <br />OF CONCRETE PRACTICE” CURRENT EDITION, “SPECIFICATIONS FOR STRUCTURAL CONCRETE” (ACI 301), AND BUILDING <br />CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318). <br />2.WHEN SPECIFIED FOR USE, NORMAL WEIGHT (NWT) CONCRETE SHALL HAVE A DRY UNIT WEIGHT OF 150 ± 3 PCF. <br />AGGREGATES FOR NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C33. <br />3.CEMENT SHALL CONFORM TO PORTLAND CEMENT ASTM C-150 (TYPE II) UNLESS NOTED OTHERWISE. WHEN USED IN THE <br />CONCRETE MIX, FLY ASH SHALL CONFORM TO ASTM C618 CLASS F OR N. <br />4.MIXING WATER SHALL CONFORM TO ASTM C1602. <br />5.ADMIXTURES SHALL CONFORM TO THE FOLLOWING: <br />A.WATER REDUCTION AND SETTING TIME MODIFICATION:ASTM C494 <br />B.PRODUCING FLOWING CONCRETE:ASTM C1017 <br />C.AIR ENTRAINMENT:ASTM C260 <br />D.INHIBITING CHLORIDE-INDUCED CORROSION:ASTM C1582 <br />6.ALL NON-SHRINK GROUT SHALL CONFORM TO ASTM C1107/C1107M AND SHALL BE PRE-MIXED COMPOUND CONSISTING OF <br />NON-METALLIC AGGREGATE, CEMENT AND WATER-REDUCING AND PLASTICIZING AGENTS. <br />A.MINIMUM COMPRESSIVE STRENGTH AT 48 HOURS: 2,000 PSI <br />B.MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS: 7,000 PSI <br />7.CONCRETE SHALL ATTAIN THE FOLLOWING MINIMUM COMPRESSIVE STRENGTH (F'C) AT 28 DAYS AND SHALL MEET THE <br />OTHER REQUIREMENTS INDICATED BELOW: <br />A.FOOTINGS:3,000 PSI, NWT, 1 1/2” AGGREGATE, 0.45 W/C <br />B.SLABS ON GRADE:3,000 PSI, NWT, 1” AGGREGATE, 0.45 W/C <br />C.ALL OTHER CONCRETE:3,000 PSI, NWT, 1” AGGREGATE, 0.45 W/C <br />8.MAXIMUM SLUMP FOR CONCRETE MIXES SHALL BE 5” TYPICALLY AND 4” FOR ALL FLATWORK, WHETHER ON GRADE OR <br />ELEVATED, EXCEPT WHEN A HIGH RANGE WATER REDUCING ADMIXTURE IS SPECIFIED FOR USE IN THE CONCRETE MIX <br />DESIGN, SLUMP SHALL BE A MAXIMUM OF 9”. <br />9.CONCRETE MIX DESIGN SHALL BE PREPARED BY AN APPROVED TESTING LAB AND A REGISTERED CIVIL ENGINEER AND <br />SUBMITTED TO THE STRUCTURAL ENGINEER OF RECORD (SEOR) FOR REVIEW. CONCRETE MIX DESIGN SUBMITTALS <br />SHALL BE STAMPED AND SIGNED BY THE LICENSED ENGINEER RESPONSIBLE FOR THE MIX DESIGN. <br />10.WHEN USED, AIR ENTRAINMENT SHALL NOT BE MORE THAN 5%. <br />11.ALL FURNISHED CONCRETE MIX DESIGNS SHALL REFLECT PROVEN CONCRETE SHRINKAGE CHARACTERISTICS OF 0.0004 <br />IN/IN (0.04%) FINAL SHRINKAGE STRAIN OR LESS AT ALL SLABS (INCLUDING TOPPING SLABS WHERE THEY OCCUR), AND <br />0.0006 IN/IN (0.06%) FINAL SHRINKAGE STRAIN OR LESS AT OTHER CONCRETE ELEMENTS, AS DETERMINED IN <br />ACCORDANCE WITH ASTM C157. <br />12.CONCRETE SHALL BE CONVEYED TO FINAL LOCATION BY METHODS THAT PREVENT SEGREGATION OR LOSS OF <br />CONSTITUENTS AND ENSURE THE REQUIRED CONCRETE QUALITY. <br />13.WATER SHALL NOT BE ADDED TO CONCRETE AT THE SITE. <br />14.LOCATE CONSTRUCTION AND/OR CONTROL JOINTS AS INDICATED IN CONTRACT DOCUMENTS AND/OR SUBMIT <br />INFORMATION FOR ACCEPTANCE OF PROPOSED LOCATION AND TREATMENT OF JOINTS NOT INDICATED IN CONTRACT <br />DOCUMENTS. <br />15.ALL CONSTRUCTION JOINTS SHALL BE ROUGHENED TO 1/4” AMPLITUDE, THOROUGHLY CLEANED AND ALL LAITANCE <br />REMOVED. LONGITUDINAL KEYWAYS, 1 1/2” DEEP, SHALL BE USED WHERE INDICATED IN THE CONTRACT DOCUMENTS. ALL <br />JOINTS SHALL BE THOROUGHLY DAMPENED, BUT WITHOUT STANDING WATER, IMMEDIATELY BEFORE PLACING NEW <br />CONCRETE. <br />16.THE CONTRACTOR(S) SHALL BE RESPONSIBLE FOR COORDINATING WITH ALL TRADES TO VERIFY THE LOCATION OF ALL <br />ITEMS SUCH AS, BUT NOT LIMITED TO, SLEEVES, ANCHORS, ANCHOR BOLTS, CONDUITS, EMBED PLATES ETC. TO BE <br />INSTALLED WITHIN CONCRETE ELEMENTS. EMBEDDED ITEMS NOT SPECIFICALLY SHOWN IN THE STRUCTURAL DRAWINGS <br />SHALL BE LOCATED BY THE TRADES/SUB-CONTRACTORS INVOLVED, AND SHALL BE REVIEWED BY THE SEOR PRIOR TO <br />PLACEMENT OF CONCRETE. IN COORDINATING THE LOCATION OF EMBEDDED ITEMS NOT OTHERWISE LOCATED IN THE <br />STRUCTURAL DRAWINGS, PRIORITY SHALL BE GIVEN TO MAINTAIN SPACING AND CONTINUITY OF ALL REINFORCING. <br />EMBEDDED ITEMS SHALL BE WELL DISTRIBUTED TO AVOID CLUSTERING IN SUCH A MANNER AS TO REQUIRE CUTTING OR <br />RELOCATION OF REINFORCING STEEL. <br />17.UNLESS OTHERWISE NOTED, BOLTS EMBEDDED IN CONCRETE SHALL BE ASTM F-1554 GR 36. ALL EMBEDDED ANCHOR <br />BOLTS SHALL BE HEADED-TYPE. DO NOT USE J-TYPE BOLTS. <br />18.UNLESS OTHERWISE NOTED, A 3/4” CHAMFER SHALL BE PROVIDED AT EXPOSED EDGES OF CONCRETE BEAMS AND <br />COLUMNS. <br />19.PRIOR TO PLACING CONCRETE, ALL EMBEDDED ITEMS, INCLUDING REINFORCING STEEL, SHALL BE WELL SECURED IN <br />POSITION. CONCRETE SHALL NOT BE POURED UNTIL ALL FORMS AND REINFORCING HAVE BEEN INSPECTED, ALL <br />PREPARATIONS FOR THE PLACEMENT HAVE BEEN COMPLETED, AND THE PREPARATIONS HAVE BEEN REVIEWED BY THE <br />PROJECT INSPECTOR. <br />20.ONLY ONE GRADE OF CONCRETE SHALL BE ALLOWED AT THE JOB SITE AT ANY ONE TIME. <br />21.CONCRETE TO BE PLACED DURING COLD WEATHER SHALL COMPLY WITH ACI 306R, “GUIDE TO COLD WEATHER <br />CONCRETING” AND ACI 306.1, “STANDARD SPECIFICATION FOR COLD WEATHER CONCRETING”. <br />22.CONCRETE TO BE PLACED DURING HOT WEATHER SHALL COMPLY WITH ACI 305R, “GUIDE TO HOT WEATHER <br />CONCRETING” AND ACI 305.1, “STANDARD SPECIFICATION FOR HOT WEATHER CONCRETING”. <br />23.CONCRETE SHALL BE MAINTAINED IN A CONTINUOUSLY MOIST CONDITION ABOVE 50F FOR A MINIMUM OF SEVEN (7) DAYS <br />AFTER PLACEMENT. THE 7-DAY REQUIREMENT MAY BE REDUCED TO 3 DAYS FOR HIGH-EARLY-STRENGTH CONCRETE. <br />ALTERNATE ACCELERATED CURING METHODS MAY BE APPROVED BY THE SEOR IF SATISFACTORY PERFORMANCE CAN <br />BE ASSURED. <br />24.THE CONTRACTOR SHALL DEVELOP A PROCEDURE AND SCHEDULE FOR REMOVAL OF SHORES AND INSTALLATION OF <br />RE-SHORES, AS REQUIRED. NO CONSTRUCTION LOADS SHALL BE SUPPORTED ON, NOR ANY SHORING REMOVED FROM, <br />ANY PART OF THE ELEVATED STRUCTURE UNDER CONSTRUCTION EXCEPT WHEN THE CONTRACTOR'S ANALYSIS, <br />PROCEDURES AND SCHEDULE INDICATE THAT THE SUBJECT PART OF THE STRUCTURE HAS SUFFICIENT STRENGTH AND <br />STIFFNESS TO SUPPORT ITS WEIGHT AND LOAD PLACED THEREON WITHOUT ADVERSE EFFECT. AT A MINIMUM, ALL <br />ELEVATED STRUCTURAL MEMBERS SHALL BE SHORED UNTIL CONCRETE HAS REACHED DESIGN STRENGTH AND <br />ORIGINAL SHORING OR RE-SHORING SHALL REMAIN IN PLACE FOR A MINIMUM OF 28 DAYS. <br />25.FOOTINGS SUPPORTING BUILDING LOADS, CONSISTING OF COLUMN OR WALL SELF-WEIGHT, FORMWORK AND/OR <br />REINFORCING STEEL, SHALL NOT BE FURTHER LOADED UNTIL THE FOOTING CONCRETE REACHES DESIGN STRENGTH <br />AND THE CONCRETE HAS CURED FOR A MINIMUM OF 7 DAYS. <br />26.ALL CONCRETE SHALL BE TESTED AND INSPECTED AS REQUIRED PER THE SPECIAL INSPECTION SECTION OF THESE <br />GENERAL NOTES. <br />STRUCTURAL AND MISCELLANEOUS STEEL: <br />1.ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC <br />SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS (AISC 360), <br />LATEST EDITION, AND SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS (AISC 341) LATEST EDITION. <br />2.ALL WELDING SHALL COMPLY WITH AWS SPECIFICATION D1.1/D1.1M. WELDING ON PARTS OF THE SEISMIC FORCE <br />RESISTING SYSTEM (SFRS) SHALL ALSO CONFORM TO AWS D1.8/D1.8M. WELDING SHALL BE PERFORMED BY WELDERS <br />CERTIFIED FOR THE TYPE OF WELDING TO BE PERFORMED. <br />3.WELDING PROCEDURE SPECIFICATIONS (WPS) SHALL BE SUBMITTED FOR REVIEW FOR EACH WELD TYPE, WELDING <br />PROCESS, WELDING ELECTRODE CLASSIFICATION AND/OR BASE MATERIAL (WHERE ASTM GRADE OR ALLOY VARIES) <br />SHOWN ON THE DRAWINGS IN CONFORMANCE WITH AWS D1.1/D1.1M, D1.4/D1.4M AND D1.8/D1.8M AS APPLICABLE. EACH <br />WPS SHALL BE RECORDED ON FORMS RECOMMENDED BY THE APPLICABLE AWS STANDARD AND SHALL BE REVIEWED BY <br />AN AWS SCWI CERTIFIED INSPECTOR AND SUBMITTED TO THE SEOR AND, IF THE PROJECT IS GOVERNED BY DSA OR <br />OSHPD, THE INSPECTOR OF RECORD (IOR) FOR REVIEW. IF A WELD ASSEMBLY NOTED ON PLANS DOES NOT FALL WITHIN <br />THE PREQUALIFIED CRITERIA, CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A WELDING PROCEDURE <br />QUALIFICATION RECORD FOR THE SPECIFIED WELD AS PART OF THE WPS SUBMITTAL. <br />4.ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL CONFORM TO THE FOLLOWING SPECIFICATION (UNLESS NOTED <br />OTHERWISE): <br />A.WIDE FLANGE SECTIONS (W,WT)ASTM A-992 FY=50KSI <br />B.CHANNELS AND MISC SHAPES (C,MC,S,M)ASTM A-36 FY=36KSI <br />C.ANGLES AND PLATES ASTM A-36 FY=36KSI <br />D.PIPE (STD,X-STRG,XX-STRG)ASTM A-53 TYPE E, GR B FY=35KSI <br />E.HSS TUBE (SQ,RECTANG)}ASTM A-500, GR C FY=50KSI <br />SULFUR CONTENT SHALL BE LESS THAN OR EQUAL TO 0.05% <br />F.HSS TUBE (ROUND)ASTM A-500, GR C FY=46KSI <br />SULFUR CONTENT SHALL BE LESS THAN OR EQUAL TO 0.05% <br />5.STRUCTURAL STEEL SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND SEOR FOR REVIEW PRIOR TO <br />FABRICATION AND ERECTION, IN ACCORDANCE WITH NOTE 12 OF GENERAL STRUCTURAL NOTES. <br />6.WHEN FABRICATING BEAMS PLACE NATURAL CAMBER UP. A TOLERANCE OF + 0, -1/4 INCH MAY BE APPLIED TO ALL <br />SPECIFIED CAMBERS. <br />7.AFTER FABRICATION, ALL STEEL SHALL BE CLEANED FREE OF RUST, LOOSE MILL SCALE, AND OIL. <br />8.ALL STEEL EXPOSED TO MOISTURE OR WEATHER SHALL BE HOT-DIPPED GALVANIZED, UNLESS NOTED OTHERWISE. <br />GALVANIZING SHALL BE IN CONFORMANCE WITH ASTM A123 AND A153. REPAIR GALVANIZING AFTER WELDING SHALL BE IN <br />ACCORDANCE WITH ASTM A780. <br />9.HOT-DIP GALVANIZE OR PROVIDE THREE-INCH (3") MINIMUM CONCRETE COVER AROUND ALL STRUCTURAL STEEL BELOW <br />GRADE. <br />10.SEE ARCHITECTURAL DRAWINGS FOR PAINTING OF STRUCTURAL STEEL. STRUCTURAL STEEL EMBEDDED IN CONCRETE <br />OR MASONRY SHALL BE UNPAINTED. <br />11.WHERE CARBON STEEL IS IN CONTACT WITH STAINLESS STEEL OR WHERE EITHER CARBON OR STAINLESS STEEL IS IN <br />CONTACT WITH ALUMINUM, PHENOLIC SHIM OR BREAK SHALL BE INSTALLED TO SEPARATE DISSIMILAR METALS. <br />12.BOLTS, THREADED RODS, AND WASHERS SHALL CONFORM TO THE FOLLOWING, UNO: <br />A.MACHINE BOLTS ASTM A-307 <br />B.HIGH STRENGTH BOLTS ASTM A-325-N OR A-490 <br />C.THREADED RODS, UNO ASTM F1554 GR36 <br />D.WELDED HEADED STUDS ASTM A-108, GRADE 1010-1020 <br />E.WASHERS ASTM F-436 <br />F.WASHERS AT NON-SEISMIC/WIND-RESISTING-FRAME COLUMNS WHERE <br />HOLES AT COLUMN BASE PLATE ARE OVER-SIZED, ONLY WHEN REQUESTED <br />BY CONTRACTOR AND APPROVED BY SEOR:ASTM F-436 5/16” THICK <br />G.ANCHOR BOLTS IN CONCRETE OR MASONRY ASTM F-1554, GR 36 <br />H.HIGH STRENGTH ANCHOR BOLTS IN CONCRETE STM F-1554, GR 105 <br />13.ANCHOR BOLTS SHALL BE HEADED. J-BOLTS SHALL NOT BE USED. <br />14.BOLTED CONNECTIONS SHALL HAVE A MINIMUM OF TWO 3/4” DIAMETER BOLTS UNLESS SHOWN OTHERWISE. <br />15.UNLESS NOTED OTHERWISE, BOLTS SHALL BE INSTALLED "SNUG TIGHT". THE SNUG TIGHT CONDITION IS DEFINED AS THE <br />TIGHTNESS THAT EXISTS WHEN ALL PLIES OF THE JOINT ARE IN FIRM CONTACT. BOLTS OF SLOTTED CONNECTIONS <br />SHALL BE INSTALLED "HAND TIGHT" ONLY, WITH THREADS SPOILED. THE HAND TIGHT CONDITION IS DEFINED AS THE <br />TIGHTNESS THAT EXISTS WHEN THE WASHER AND BOLT HEAD ARE BROUGHT INTO FULL CONTACT WITH WEB OR SHEAR <br />TAB WITH A SPUD WRENCH AND THE NUT IS THEN BACKED OFF ONE QUARTER OF A TURN. WHERE SLOTTED <br />CONNECTIONS ARE INDICATED, THE WASHER SHALL BE PLACED OVER THE SLOTTED HOLE. BOLTS INDICATED AS <br />SLIP-CRITICAL SHALL BE PRE-TENSIONED PER SECTION 8.2 OF SPECIFICATION FOR STRUCTURAL JOINTS USING <br />HIGH-STRENGTH BOLTS. <br />16.HOLES FOR BOLTED CONNECTIONS AND ANCHOR BOLTS SHALL BE AISC “STANDARD” HOLES LIMITED TO 1/16-INCH <br />LARGER IN DIAMETER THAN NOMINAL BOLT DIAMETER FOR 7/8-INCH DIAMETER BOLTS AND SMALLER, AND 1/8-INCH <br />LARGER IN DIAMETER THAN NOMINAL BOLT DIAMETER FOR 1-INCH AND LARGER BOLTS, UNLESS NOTED OTHERWISE. <br />OVERSIZED AND SLOTTED HOLES REQUIRE THE APPROVAL OF THE SEOR, UNLESS SPECIFICALLY DETAILED ON THE <br />APPROVED DRAWINGS. <br />17.PROVIDE BEVELED WASHERS WHERE JOINT FACE SLOPE IS GREATER THAN 1:20. <br />18.SEE CONCRETE GENERAL NOTES FOR NON-SHRINK GROUT SPECIFICATIONS. <br />19.FLANGE STIFFENER PLATES SHALL BE ORIENTED SO THAT ROLLING DIRECTION OF PLATE IS PARALLEL WITH DIRECTION <br />OF PRINCIPLE STRESS. <br />20.ALL STRUCTURAL STEEL WELDING SHALL BE PERFORMED WITH E70XX ELECTRODES. <br />21.WHERE FILLET WELD SYMBOL IS SHOWN WITHOUT INDICATION OF THROAT SIZE, USE MINIMUM SIZE WELDS AS SPECIFIED <br />BELOW: <br />22.WHERE LENGTH OF WELD IS NOT INDICATED, WELD SHALL BE FULL LENGTH OF JOINT. <br />23.ALL COMPLETE- AND PARTIAL-JOINT-PENETRATION GROOVE WELDS SHALL BE PERFORMED USING "INNERSHIELD" AND <br />"ML-2" SEMI-AUTOMATIC EQUIPMENT. <br />24.SEE SPECIAL INSPECTION AND TESTING NOTES FOR INSPECTION AND TESTING REQUIREMENTS. <br />TABLE J2.4 <br />MINIMUM SIZE OF FILLET WELDS <br />MATERIAL THICKNESS OF <br />THINNER PART JOINED <br />MINIMUM SIZE OF <br />FILLET WELD <br />TO 1/4" (6MM) INCLUSIVE 1/8" (3MM) <br />OVER 1/4" (6MM) TO 1/2" (13MM)3/16" (5MM) <br />OVER 1/2" (13MM) TO 3/4" (19MM)1/4" (6MM) <br />OVER 3/4" (19MM)5/16" (8MM) <br />No.3503 <br />L <br />I <br />GNE <br />L <br />S NO <br />B A <br />LAE <br />A L I OFRNIA <br />N <br />E <br />ER <br />I <br />E <br />ET <br />ORPD <br />F E <br />R IR <br />L.KC <br />E <br />TS <br />AT <br />CFO <br />RE <br />G <br />S <br />I <br />S <br />URALTSRUCT <br /> <br />Renewal Date <br />LICENSED ARCHITECT <br />STATE OF C A L I FORNI <br />A <br />J <br />C32284 <br />HOSHUAJAMESSMIT <br />05/31/25 <br />03/24/25 <br />914-918 N Bewley <br />St5/8/2025