Laserfiche WebLink
1. COMPLY WITH THE REQUIREMENTS IN CHAPTER 23 OF THE CODE AND AF&PA'S WCD 1, "DETAILS FOR CONVENTIONAL <br />WOOD FRAME CONSTRUCTION," UNLESS OTHERWISE INDICATED. <br />2. NOT USED. <br />3. DIMENSIONAL LUMBER FRAMING: <br />A. SPECIES, GRADE, AND MOISTURE CONTENT NOTED BELOW: <br />4. GLUE-LAMINATED LUMBER: <br />A. THE FABRICATION OF STRUCTURAL GLUE-LAMINATED TIMBER SHALL COMPLY WITH THE REQUIREMENTS OF THE <br />NATIONAL DESIGN SPECIFICATION (NDS), LATEST EDITION, AS MODIFIED BY DIV III, CHAPTER 23 OF THE CODE. ALL <br />FABRICATION AND WORKMANSHIP SHALL BE IN CONFORMANCE WITH THE <br />CURRENT EDITION OF THE "STANDARD SPECIFICATIONS FOR STRUCTURAL GLUE-LAMINATED DOUGLAS FIR (COAST <br />REGION) LUMBER" BY THE WEST COAST LUMBERMAN'S ASSOCATION, AND THE CURRENT EDITION OF "TIMBER <br />CONSTRUCTION STANDARDS" BY THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (A.I.T.C.). <br />B. ALL GLUE-LAMINATED MEMBERS SHALL BE DOUGLAS FIR 24F-V8. ALLOWABLE STRESS REQUIREMENTS ARE AS <br />FOLLOWS: <br />Fbxx = 2400 PSI TENSION IN TENSION ZONE <br /> = 2400 PSI TENSION IN COMPRESSION ZONE <br />COMPRESSION, Fcxx = 650 PSI <br />SHEAR, Fvxx = 190 PSI <br />Exx = 1.8x106 PSI <br />C. THE MANUFACTURER SHALL SUBMIT COMPLETE SHOP DRAWINGS TO THE ARCHITECT/ENGINEER FOR APPROVAL <br />PRIOR TO ANY FABRICATION. <br />D. PROVIDE CAMBERS AS NOTED ON THE DRAWINGS. <br />E. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS AND INFORMATION. <br />5. FASTENERS: <br />A. WHERE ROUGH CARPENTRY IS EXPOSED TO WEATHER, IN GROUND CONTACT, PRESERVATIVE TREATED, FIRE <br />RETARDANT TREATED, OR IN AREA OF HIGH RELATIVE HUMIDITY, PROVIDE FASTENERS WITH HOT-DIP ZINC COATING <br />COMPLYING WITH ASTM A 153. <br />B. NAILS: ASTM F1667, COMMON TYPE. <br />6. WOOD CONNECTORS: <br />A. PROVIDED BASIS OF DESIGN HANGERS, STRAPS, TIES, HOLD DOWNS, ETC, AS INDICATED ON THE DRAWINGS. <br />B. WHERE CONNECTORS ARE IN EXPOSED, EXTERIOR APPLICATIONS OR IN CONTACT WITH PRESERVATIVE TREATED <br />LUMBER, PROVIDE HOT-DIP GALVANIZED OR STAINLESS STEEL CONNECTORS. <br />7. ALL LUMBER IN 2 HOUR FIRE RATED WALLS AND 3 HOUR FIRE SEPARATION WALLS SHALL USE FIRE RETARDANT <br />TREATED WOOD PER CBC SECTION 2303.2. SEE ARCHITECTURAL DRAWINGS FOR FIRE RATED WALL LOCATIONS AND <br />DETAILS. <br />8. WHERE POSTS OR MULTIPLE STUDS UNDER BEAMS OR HEADERS ARE CALLED FOR ON DRAWINGS THOSE POSTS OR <br />MULTIPLE STUDS SHALL BE CARRIED TO THE FOUNDATION/PODIUM LEVEL U.N.O. <br />9. JOIST BLOCKING AND BRIDGING: <br />A. PROVIDE FULL DEPTH SOLID BLOCKING BETWEEN JOISTS OVER SUPPORT AND BELOW PARTITION WALLS. <br />B. PROVIDE FULL DEPTH BRIDGING AT 8'-0" O.C. MAX, NOT MORE THAN 8'-0" FROM SUPPORT. <br />10. PROVIDE DOUBLE JOISTS UNDER NON-BEARING WALLS RUNNING PARALLEL TO JOISTS. <br />11. PROVIDE REQUIRED FIRE STOPPING, BACKING FOR INTERIOR FINISHES, NONBEARING WALLS, AND OTHER NON- <br />STRUCTURAL FRAMING THAT ARE NOT SHOWN ON STRUCTURAL DRAWINGS. <br />12. ALL STRUCTURAL PLYWOOD SHEATHING SHALL BE DOUGLAS FIR STANDARD GRADE STRUCTURAL I WITH EXTERIOR <br />GLUE CONFORMING TO THE LATEST EDITION OF PS1-09. ALL PANELS SHALL BEAR LEGIBLE DFPA STAMPS. <br />13. ORIENTED STRAND BOARD (OSB) MAY BE SUBSTITUTED FOR PLYWOOD PROVIDED IT HAS THE SAME APA <br />PERFORMANCE STANDARD RATING AND CONTAINS THE SAME NUMBER OF LAYERS AS THE PLYWOOD SPECIFIED. <br />14. ALL SHEATHING SHALL BE LAID FACE GRAIN PERPENDICULAR TO FRAMING AND SHALL BE APPROVED BY THE BUILDING <br />INSPECTOR BEFORE COVERING. <br />15. ALL NAILING/SCREWING SHALL CONFORM TO THE APPLICABLE BUILDING CODE AND REGULATIONS. <br />16. ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED AND SHALL BE APPROVED BY THE BUILDING I <br />NSPECTOR PRIOR TO COVERING. <br />17. UNLESS OTHERWISE NOTED, ALL WOOD SILL PLATE UNDER BEARING, EXTERIOR OR SHEAR WALLS IN CONTACT WITH <br />CONCRETE OR MASONRY SHALL BE PRESSURE TREATED AND BOLTED TO CONCRETE OR MASONRY WITH GALVANIZED <br />OR STAINLESS STEEL ANCHORS AS INDICATED ON THE DRAWINGS. <br />18. ALL BOLT HEADS AND NUTS WHICH BEAR AGAISNT THE FACE OF WOOD MEMBERS SHALL BE PROVIDED WITH METAL <br />WASHERS (1/4"x3"x3" MIN). <br />19. ALL 1/2" DIAMETER AND LARGER BOLTS CALLED OUT ON DRAWINGS, INCLUDING ANCHOR BOLTS (A.B.) SHALL HAVE <br />STEEL SQUARE PLATE WASHERS AS LISTED BELOW UNDER THE HEAD AND/OR NUT BEARING ON WOOD. (ALL ANCHOR <br />BOLTS SHALL BE 12" LONG, UNLESS NOTED OTHERWISE. <br />20. ALL ANCHOR BOLTS OR ANY OTHER BOLT ANCHORING THE FOUNDATION SILL PLATE SHALL HAVE STEEL SQUARE PLATE <br />WASHERS PER THE BELWO SCHEDULE BETWEEN THE FOUNDATION SILL PLATE AND THE NUT (UNO). <br />21. FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON STRONG TIE (OR <br />ENGINEER APPROVED EQUAL) AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS. HARDWARE SHALL BE FULLY <br />NAILED FOR MAXIMUM CAPACITY, UNLESS NOTED OTHERWISE. <br />22. LAG BOLTS (LAG SCREWS): PROVIDE LEAD HOLE 40% - 70% OF THREADED SHANK DIAMETER AND FULL DIAMETER FOR <br />SMOOTH SHANK PORTION. <br />23. ALL NAILS CONNECTING WOOD MEMBERS SHALL BE COMMON NAILS. MINIMUM NAILING REQUIREMENTS OUTLINED IN <br />TABLE 2304.10.1 SHALL BE FOLLOWED UNLESS OTHERWISE NOTED. <br />24. RETIGHTEN BOLTS BEFORE CLOSING-IN <br />25. ALL HOLD DOWN ANCHORS AND ALL OTHER ANCHORS AND MISCELLANEOUS METAL HANGERS ARE BY SIMPSON OR <br />APPROVED EQUAL. <br />DIMENSIONAL LUMBER <br />USE SPECIES GRADE MOISTURE <br />CONTENT <br />LUMBER 2" TO 4" THICK x 5" OR WIDER <br />(JOISTS/RAFTERS) <br />DOUGLAS <br />FIR-LARCH #2 & BETTER KD (15%) <br />LUMBER 2" TO 3" THICK x 4" TO 6" WIDE <br />(STUDS) <br />DOUGLAS <br />FIR-LARCH #2 & BETTER KD (15%) <br />LUMBER 5x5 AND GREATER (BEAMS)DOUGLAS <br />FIR-LARCH #1 S-DRY (19%) <br />LUMBER 5x5 AND GREATER (POSTS)DOUGLAS <br />FIR-LARCH #1 S-DRY (19%) <br />WASHER - THICKNESS <br />WASHER - WIDTH SQUARE <br />BOLT DIAMETER <br />5/16"5/16" <br />3" <br />1/2" 5/8" <br />7/16"3/8" <br />3 1/2" <br />3/4" 7/8" <br />1/2" <br />4" <br />1" <br />3" 3" <br />WASHER - THICKNESS <br />WASHER - WIDTH <br />BOLT DIAMETER <br />2 3/4" <br />5/16"1/4" <br />2 1/2" <br />1/2" 5/8" <br />7/16"3/8" <br />3"3 1/2" <br />3/4" 7/8" <br />1/2" <br />4" <br />1" <br />WOODWOOD (CONT'D) <br />1. DESIGN OF ANCHORAGE AND SEISMIC BRACING FOR ALL MEP EQUIPMENT ARE DELEGATED DESIGN. <br />2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND CONSTRUCTION OF VERTICAL GRAVITY <br />SUPPORT, SEISMIC RESTRAINT, AND ANCHORAGE TO PRIMARY STRUCTURE OF ALL MEP EQUIPMENT, <br />INCLUDING AIR TERMINAL UNITS AND SOUND TRAPS, EXCEPT AS OTHERWISE SPECIFIED ON THE CONTRACT <br />DOCUMENTS. DESIGN SHALL BE CAPABLE OF MITIGATING VIBRATIONS AND RESISTING DEAD AND THERMAL <br />LOADS, AS WELL AS THE LOAD AND RELATIVE DISPLACEMENT EFFECTS PRESCRIBED BY ASCE 7-16, CH. 13. <br />RELEVANT SEISMIC PARAMETERS AND COEFFICIENTS ARE INDICATED ON THESE DRAWINGS. APPROPRIATE <br />COMPONENT COEFFICIENTS SHALL BE DETERMINED BY THE CONTRACTOR PER ASCE 7-16, CH. 13. DESIGN <br />SHALL BE SUBMITTED TO THE ARCHITECT FOR GENERAL CONFORMANCE REVIEW. <br />3. CONTRACTOR SHALL VERIFY THAT ACTUAL PROCURED EQUIPMENT SPECIFICATIONS CONFORM TO DETAILS <br />SHOWN ON THESE DRAWINGS (E.G. WEIGHT, SIZE, LOCATIONS, ETC.). WHEN DISCREPANCIES ARE DISCOVERED, <br />CONTRACTOR SHALL NOTIFY ARCHITECT AND OWNER'S REPRESENTATIVE PRIOR TO FABRICATION OR <br />INSTALLATION AND PROVIDE NEW EQUIPMENT SPECIFICATIONS TO ARCHITECT FOR DESIGN TEAM REVIEW AND <br />APPROVAL. <br />4. VERTICAL SUPPORT AND SEISMIC RESTRAINT OF UTILITY DISTRIBUTION SYSTEMS <br />A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND CONSTRUCTION OF COMPLETE VERTICAL <br />GRAVITY SUPPORT, SEISMIC RESTRAINT, AND ANCHORAGE TO THE PRIMARY FRAME FOR ALL UTILITY <br />DISTRIBUTION AND EQUIPMENT SYSTEMS IN CONFORMANCE WITH THE CODE AND ASCE 7-16, CH. 13, <br />INCLUDING BUT NOT LIMITED TO: <br />i. MECHANICAL DUCTWORK AND PIPING <br />ii. ELECTRICAL CONDUIT <br />iii. PLUMBING LINES <br />iv. COMMUNICATION/INFORMATION TECHNOLOGY UTILITIES <br />v. SPRINKLER SYSTEMS. <br />B. DESIGN SHALL BE CERTIFIED BY A CIVIL ENGINEER REGISTERED IN THE STATE OF CALIFORNIA AND <br />COMPLETED IN CONFORMANCE WITH REQUIREMENTS INDICATED IN THE PROJECT SPECIFICATIONS, <br />DRAWINGS, AND THE CODE, UTILIZING THE SEISMIC PARAMETERS AND COEFFICIENTS INDICATED ON <br />THESE DRAWINGS AND SPECIFIED IN ASCE 7-16. <br />C. DESIGN SHALL COMPLY WITH THE SEISMIC FORCES AND RELATIVE DISPLACEMENTS REQUIRED BY <br /> ASCE 7-16, SECTION 13.3, UNLESS PRESCRIPTIVE REQUIREMENTS ARE FOLLOWED PER EXCEPTIONS <br />LISTED FOR: <br />i. CONDUIT, CABLE TRAY, AND RACEWAYS (ASCE 7-16, SECTION 13.6.5) <br />ii. DUCT SYSTEMS (ASCE 7-16, SECTION 13.6.6) <br />iii. PIPING AND TUBING SYSTEMS (ASCE 7-16, SECTION 13.6.7.3) <br />D. IN-LINE DUCT COMPONENTS WEIGHING 75 LB OR LESS: SMALL TERMINAL UNITS, DAMPERS, LOUVERS, <br />DIFFUSERS, ETC., THAT ARE NOT BRACED INDEPENDENTLY SHALL BE POSITIVELY ATTACHED WITH <br />MECHANICAL FASTENERS TO THE RIGID DUCT ON BOTH SIDES. PIPING CONDUIT ATTACHED TO IN-LINE <br />EQUIPMENT SHALL BE PROVIDED WITH ADEQUATE FLEXIBILITY TO ACCOMMODATE THE SEISMIC RELATIVE <br />DISPLACEMENTS OF ASCE 7-16, SECTION 13.3.2. <br />E. SPACING AND DETAILS OF THE SUPPORT AND BRACING OF FIRE SPRINKLER PIPING SHALL COMPLY WITH <br />THE GOVERNING EDITION OF NFPA 13 AND ASCE 7-16, SECTION 13.6.7.2, AS MODIFIED BY THE CODE. <br />F. BRACING AND ANCHORAGE DESIGN MAY BE REFERRED TO A PRE-APPROVED ANCHORAGE SYSTEM AND <br />THE CONTRACTOR SHALL PROVIDE ENGINEERING DOCUMENTATION, INCLUDING INSTALLATION <br />GUIDES/MANUALS FOR THE SELECTED PRE-APPROVED SYSTEM, TO THE ARCHITECT AND OWNER'S <br />REPRESENTATIVE. <br />G. POST-INSTALLED CONCRETE ANCHOR TYPES AND INSTALLATION REQUIREMENTS SHALL BE AS <br />SPECIFIED ON THESE DRAWINGS. <br />H. STORY DRIFT <br />i. UTILITY DISTRIBUTION SYSTEMS, INCLUDING PIPING, DUCTWORK AND CONDUITS, SHALL BE <br />DESIGNED TO ACCOMMODATE THE INTER-STORY DRIFT SPECIFIED ON THESE DRAWINGS (SEE <br />DELEGATED DESIGN NOTES), AS REQUIRED PER ASCE 7-16, SECTION 13.3.2. <br />ii. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING FLEXIBLE CONNECTIONS BETWEEN <br />UTILITY LINES AND FIXED EQUIPMENT IN CONFORMANCE WITH EQUIPMENT MANUFACTURER'S <br />RECOMMENDATIONS, AS REQUIRED TO ACCOMMODATE INTER-STORY DRIFT AND FLOOR LIVE <br />LOAD DEFLECTIONS. <br />iii. PIPES, DUCTS AND CONDUITS THAT ROUTE WITHIN EXTERIOR WALL FRAMING SHALL NOT IMPEDE <br />THE DESIGN DRIFT AT EXTERIOR FRAMING SLIP JOINTS. PIPES, DUCTS AND CONDUITS THAT <br />CROSS EXTERIOR FRAMING SLIP JOINTS SHALL BE DESIGNED AND DETAILED TO ALLOW THE <br />EXTERIOR FRAMING TO ACCOMMODATE THE DESIGN DISPLACEMENT CRITERIA (SEE “DELEGATED <br />DESIGN”) AND SHALL, THEMSELVES, ACCOMMODATE THESE DISPLACEMENTS IF THEY ARE <br />ATTACHED TO ANY ELEMENT OF THE EXTERIOR FRAMING SYSTEM. <br />EQUIPMENT ANCHORAGE <br />2-16d AT EACH BEARING <br />20d AT 32" (813mm) OC AT TOP AND BOTTOM AND <br />STAGGERED 2-20d AT ENDS AND AT EACH SPLICE <br />16d AT 24" (610mm) OC <br />16d AT 16" (406mm) o.c. ALONG EACH EDGE <br />8d AT 6" (152mm) OC <br />16d AT 16" (406mm) OC <br />16d AT 24" (610mm) OC <br />4-8d, TOENAIL OR 2-16d, END NAIL <br />3-16d PER 16"(406 mm) <br />16d AT 16" (406mm) OC <br />3. 1" X 6" (25mm X 152mm) SUBFLOOR OR LESS TO EACH JOIST, FACE NAIL <br />28. FIBERBOARD SHEATHING: <br /> 1/2" (12.7mm) OR LESS <br />27. PANEL SIDING (TO FRAMING) : <br />1 1/8"-1 1/4" (29mm-32mm) <br />7/8"-1" (22mm-25mm) <br />3/4" (19mm) AND LESS <br /> COMBINATION SUBFLOOR-UNDERLAYMENT (TO FRAMING): <br />1 1/8"-1 1/4" (29mm-32mm) <br />7/8"-1" (22mm-25mm) <br />19/32"-3/4" (15mm-19mm) <br />1/2" (12.7mm) AND LESS <br /> SUBFLOOR AND WALL SHEATHING (TO FRAMING): <br />26. WOOD STRUCTURAL PANELS AND PARTICLEBOARD: <br />24. BUILT-UP GIRDER AND BEAMS <br />23. BUILT-UP CORNER STUDS <br />22. WIDER THAN 1" X 8" (25mm X 203mm) SHEATHING TO EACH BEARING, FACE NAIL <br />21. 1" X 8" (25mm X 203mm) SHEATHING OR LESS TO EACH BEARING, FACE NAIL <br />20. 1" (25mm) BRACE TO EACH STUD AND PLATE, FACE NAIL <br />19. RAFTER TO PLATE, TOENAIL <br />18. CEILING JOISTS TO PARELLEL RAFTERS, FACE NAIL <br />17. CEILING JOIST, LAPS OVER PARTITIONS, FACE NAIL <br />16. CONTINUOUS HEADER TO STUD, TOENAIL <br />15. CEILING JOISTS TO PLATE, TOENAIL <br />14. CONTINUOUS HEADER, TWO PIECES <br />13. TOP PLATES, LAPS AND INTERSECTIONS, FACE NAIL <br />12. RIM JOIST TO TOP PLATE, TOENAIL <br />11. BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE, TOENAIL <br /> DOUBLE TOP PLATES, LAP SPLICE <br />10. DOUBLE TOP PLATES, TYPICAL FACE NAIL <br />9. DOUBLE STUDS, FACE NAIL <br />7. TOP PLATE TO STUD, END NAIL <br /> SOLE PLATE TO JOIST OR BLOCKING, AT BRACED WALL PANELS <br />6. SOLE PLATE TO JOIST OR BLOCKING, TYPICAL FACE NAIL <br />5. 2" (51mm) SUBFLOOR TO JOIST OR GIRDER, BLIND AND FACE NAIL <br />4. WIDER THAN 1" X 6" (25mm X 152mm) SUBFLOOR TO EACH JOIST, FACE NAIL <br /> 25/32" (20mm) <br />29. INTERIOR PANELING <br /> 3/8" (9.5mm) <br /> 1/4" (6.4mm) <br /> 1/2" (12.7mm) <br /> 5/8" (16mm) <br />25. 2" (51mm) PLANKS <br />8. STUD TO SOLE PLATE <br />7 <br />2. BRIDGING TO JOIST, TOENAIL EACH END <br />1. JOIST TO SILL OR GIRDER, TOENAIL <br />NAILING SCHEDULE <br />4 5 <br />48d <br />6d <br /> 4d <br />NO.16 ga <br />11 <br />10 <br />9 <br />NO.11 ga <br />NO.16 ga <br />6d <br /> NO.11 ga <br />8d <br />6d <br />8 <br />9 <br />4 <br />8 <br />6 <br />6 <br />10d OR 8d <br />8d <br />6d <br />10d OR 8d <br />8d <br />8d AND 6d <br />4 <br />4 5 <br />5 <br />5 <br />5 <br />3 <br />3-8d <br />6d <br />3-8d <br />3 <br />2-8d <br />2-8d <br />3-8d <br />3-16d <br />3-16d <br />4-8d <br />2-16d <br />3-8d <br /> 8-16d <br />2-16d <br />2-16d <br /> 3-8d <br />2-8d <br />2-8d <br />3-8d <br />NAILING 1 <br />1. THIS NAILING SCHEDULE SHALL ONLY BE USED IF CONDITION IS NOT OTHERWISE DETAILED OR SPECIFIED ON THE <br /> CONSTRUCTION DOCUMENTS. COMMON NAILS SHALL BE USED EXCEPT WHERE OTHERWISE STATED. <br />2. NAILS SPACED AT 6 INCHES (152mm) ON CENTER AT EDGES, 12 INCHES(305mm) AT INTERMEDIATE SUPPORTS EXCEPT 6 <br />INCHES (152mm) AT ALL SUPPORTS WHERE SPANS ARE 48 INCHES (1219mm) OR MORE. FOR NAILING OF WOOD <br />STRUCTURAL PANEL AND PARTICLEBOARD DIAPHRAGMS AND SHEAR WALLS, REFER TO SECTIONS OF THE CODE. <br />3. COMMON OR DEFORMED SHANK. <br />4. COMMON <br />5. DEFORMED SHANK <br />6. CORROSION-RESISTANT SIDING OR CASING NAILS CONFORMING TO THE REQUIREMENTS OF THE CODE. <br />7. FASTENERS SPACED 3 INCHES (76mm) ON CENTER AT EXTERIOR EDGES AND 6 INCHES (152mm) ON CENTER <br />AT INTERMEDIATE SUPPORTS. <br />8. CORROSION-RESISTANT ROOFING NAILS WITH 7/16-INCH-DIAMETER (11mm) HEAD AND 1 1/2-INCH (38mm) LENGTH FOR 1/2" <br /> INCH (12.7mm) SHEATHING AND 1 3/4-INCH (44mm) LENGTH FOR 25/32 -INCH (20mm) SHEATHING CONFORMING TO THE <br /> REQUIREMENTS OF THE CODE. <br />9. CORROSION-RESISTANT STAPLES WITH NOMINAL 7/16-INCH (11mm) CROWN AND 1 1/8-INCH (29mm) LENGTH FOR 1/2- <br /> INCH (12.7mm) SHEATHING AND 1 1/2-INCH (38mm) LENGTH FOR 25/32 -INCH (20mm) SHEATHING CONFORMING TO <br /> THE REQUIREMENTS OF THE CODE. <br />10. PANEL SUPPORTS AT 16 INCHES (406mm) [20INCHES (508 mm) IF STRENGTH AXIS DIRECTION OF THE PANEL, <br /> UNLESS OTHERWISE MARKED]. CASING OR FINISH NAILS SPACED 6 INCHES (152mm) ON PANEL EDGES, 12 <br /> INCHES (305mm) AT INTERMEDIATE SUPPORTS. <br />11. PANEL SUPPORT AT 24 INCHES (610mm). CASING OR FINISH NAILS SPACED 6 INCHES (152mm) ON PANEL <br /> EDGES, 12 INCHES (305mm) AT INTERMEDIATE SUPPORTS. <br />CONNECTION <br />STRUCTURAL OBSERVATION <br />1. <br />2. <br />3. <br />4. <br />STRUCTURAL OBSERVATION SHALL BE PERFORMED BY THE STRUCTURAL ENGINEER OF <br />RECORD IN ACCORDANCE WITH SECTION 1704 OF THE CODE. <br />STRUCTURAL OBSERVATION IS THE VISUAL OBSERVATION OF THE ELEMENTS AND <br />CONNECTIONS OF THE STRUCTURAL SYSTEM AT SIGNIFICANT CONSTRUCTION STAGES AND <br />THE COMPLETED STRUCTURE FOR GENERAL CONFORMANCE TO THE APPROVED PLANS AND <br />SPECIFICATION. STRUCTURAL OBSERVATION DOES NOT WAIVE THE RESPONSIBILITY FOR <br />THE INSPECTIONS REQUIRED OF THE BUILDING INSPECTOR OR THE DEPUTY INSPECTOR. <br />THE STRUCTURAL ENGINEER OF RECORD SHALL PERFORM THE STRUCTURAL OBSERVATION. <br />THE CONTRACTOR SHALL COORDINATE AND CALL FOR A PRE-CONSTRUCTION MEETING <br />BETWEEN THE ENGINEER OR ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGN, <br />STRUCTURAL OBSERVER, CONTRACTOR, AFFECTED SUBCONTRACTORS AND DEPUTY <br />INSPECTORS. THE PURPOSE OF THE MEETING SHALL BE TO IDENTIFY THE MAJOR <br />STRUCTURAL ELEMENTS AND CONNECTIONS THAT AFFECT THE VERTICAL AND LATERAL <br />LOAD SYSTEMS OF THE STRUCTURE AND TO REVIEW SCHEDULING OF THE REQUIRED <br />OBSERVATIONS. A RECORD OF THE MEETING SHALL BE INCLUDED IN THE FIRST <br />OBSERVATION REPORT SUBMITTED TO THE PROJECT INSPECTOR. <br />CONSTRUCTION STAGES ELEMENTS/CONNECTIONS TO BE OBSERVED <br />FOUNDATIONS <br />CONCRETE WALLS <br />STEEL ERECTION <br />REINF/CONC/ANCHOR BOLTS <br />REINF/EMBEDS <br />FRAMING/CONNECTIONS <br />9. ABANDONED ANCHORS AND ABANDONED ANCHOR HOLES: <br />A.FILL ALL EMPTY ABANDONED ANCHOR HOLES WITH A DRY-PACK MORTAR. <br />B.FOR ABANDONED EXPANSION ANCHORS WHICH CANNOT BE REMOVED WITHOUT DAMAGING <br />THE SUBSTRATE, CUT/BURN OFF THE END OF THE BOLT FLUSH WITH THE FACE OF <br />CONCRETE/MASONRY AND THEN DRIVE ABANDONED ANCHOR TO BOTTOM OF HOLE. FILL <br />REMAINDER OF HOLE WITH A DRY-PACK MORTAR. <br />C. FOR ABANDONED ADHESIVE OR UNDERCUT ANCHORS WHICH CANNOT BE REMOVED WITHOUT <br />DAMAGING THE SUBSTRATE, BURN OFF THE END OF THE BOLT/ROD 1" BELOW THE SURFACE OF <br />CONCRETE/MASONRY AND FILL REMAINDER OF HOLE WITH A DRY-PACK MORTAR. <br />D. ABANDONED ANCHOR HOLES (WHETHER FILLED WITH DRY-PACK OR CONTAINING ABANDONED <br />ANCHORS) MAY NOT BE LOCATED ANY CLOSER THAN 3x DIAMETER CENTER-TO-CENTER TO ANY <br />ANCHOR IN SERVICE. ANCHORS NOT MEETING THIS MINIMUM SPACING MAY HAVE REDUCED <br />CAPACITY AND SHALL BE REVIEWED WITH THE SEOR. <br />LIMITATIONS OF USE OF POWER ACTUATED FASTENERS: <br />PER SECTION 13.4.5 OF ASCE 7-16 POWER ACTUATED FASTENERS IN CONCRETE OR STEEL SHALL NOT BE <br />USED FOR SUSTAINED TENSION LOADS OR FOR BRACE APPLICATIONS IN SEISMIC UNLESS APPROVED FOR <br />SEISMIC LOADING. POWER ACTUATED FASTENERS IN MASONRY SHALL NOT BE PERMITTED UNLESS <br />APPROVED FOR SEISMIC LOADING. <br />EXCEPTION: POWER ACTUATED FASTENERS IN CONCRETE USED FOR SUPPORT OF ACOUSTICAL TILE OR <br />LAY-IN PANEL SUSPENDED CEILING APPLICATIONS AND DISTRIBUTED SYSTEMS WHERE THE SERVICE <br />LOAD ON ANY INDIVIDUAL FASTENER DOES NOT EXCEED 90 LB (400 N). <br />TESTING CRITERIA FOR POST-INSTALLED ANCHORS IN CONCRETE <br />1. CONDUCT TESTING OF POST- INSTALLED ANCHORS PER SECTION 1910 OF THE CODE. <br />2. WHERE THE MANUFACTURER'S INSTALLATION INSTRUCTIONS OR APPLICABLE ICC-ES EVALUATION <br />SERVICES REPORT CALL FOR THE APPLICATION OF AN INSTALLATION TORQUE, THE SPECIFIED <br />TORQUE SHALL BE APPLIED WITH A CALIBRATED TORQUE WRENCH. THE SPECIFIED INSTALLATION <br />TORQUE SHALL NOT BE EXCEEDED. <br />3. THE SPECIAL INSPECTOR SHALL BE ON THE JOBSITE DURING ANCHOR INSTALLATIONS AS REQUIRED <br />PER CHAPTER 17 OF THE CODE, UNLESS OTHERWISE NOTED IN ICC-ES ESR, TO VERIFY ANCHOR, <br />ANCHOR DIMENSIONS, CONCRETE TYPE, CONCRETE COMPRESSIVE STRENGTH, HOLE DIMENSIONS, <br />ANCHOR SPACING, EDGE DISTANCES, SLAB THICKNESS, ANCHOR EMBEDMENT, AND INSTALLATION <br />TORQUE. <br />4. TEST LOAD: REQUIRED TEST LOADS SHALL BE DETERMINED BY ONE OF THE FOLLOWING METHODS: <br />A.TWICE THE MAXIMUM ALLOWABLE TENSION LOAD OR ONE AND A QUARTER (1 1/4) TIMES THE <br />MAXIMUM DESIGN STRENGTH PROVIDED BY THE ICC REPORT OR DETERMINED PER ACI 318. THE <br />TENSION TEST LOAD NEED NOT TO EXCEED 80 PERCENT OF THE NOMINAL YIELD STRENGTH OF <br />THE ANCHOR (0.8 As Fy). SEE STRUCTURAL DETAILS FOR DESIGN-BASED TENSION TEST LOADS <br />FOR ADHESIVE ANCHORS. <br />B.THE MANUFACTURER'S RECOMMENDED INSTALLATION TORQUE AS APPROVED BY THE ICC <br />REPORT. <br />5. TENSION OR TORQUE TESTING OF POST-INSTALLED ANCHORS SHALL BE DONE IN THE PRESENCE OF <br />THE SPECIAL INSPECTOR AND A REPORT OF THE TEST RESULTS SHALL BE SUBMITTED TO THE IOR <br />AND ENFORCEMENT AGENCY. <br />6. THE SPECIAL INSPECTOR SHALL SELECT ANCHORS FOR TESTING AT RANDOM. <br />7. TEST FREQUENCY: <br />APPLICATION QUANTITY <br />STRUCTURAL 100% OF BOLTS <br />NON-STRUCTURAL 50%; ALTERNATE BOLTS IN A GROUP <br />(SUCH AS EQUIPMENT ANCHORAGE) (TEST AT LEAST HALF OF THE ANCHORS IN GROUP) <br />8. TEST METHODS: TEST LOADS MAY BE APPLIED BY ANY METHOD THAT WILL EFFECTIVELY TRANSMIT A <br />MEASURABLE TENSION LOAD TO THE ANCHOR. ACCEPTABLE METHODS INCLUDE: <br />A. USE OF HYDRAULIC JACK, WHEREBY EITHER UNCONFINED OR CONFINED TESTING SHALL BE <br />ACCEPTABLE; <br />B.USE OF CALIBRATED SPRING LOADED DEVICES; OR <br />C. USE OF A CALIBRATED TORQUE WRENCH FOR TORQUE-CONTROLLED EXPANSION ANCHORS. <br />9. TEST ACCEPTANCE CRITERIA: ACCEPTANCE CRITERIA FOR POST-INSTALLED ANCHORS SHALL BE <br />BASED ON THE ICC REPORT OR MANUFACTURER'S WRITTEN INSTRUCTION AS ACCEPTABLE TO <br />OSHPD. FIELD TESTS SHALL SATISFY THE FOLLOWING MINIMUM REQUIREMENTS: <br />A.HYDRAULIC RAM METHOD: ANCHORS TESTED WITH A HYDRAULIC JACK OR SPRING LOADED <br />DEVICES SHALL MAINTAIN THE TEST LOAD FOR A MINIMUM OF 15 SECONDS AND SHALL EXHIBIT <br />NO DISCERNABLE MOVEMENT DURING THE TENSION TEST, E.G. AS EVIDENCED BY LOOSENING OF <br />THE WASHER UNDER THE NUT. SCREW ANCHORS MAY BE LOOSENED A MAXIMUM ONE FULL TURN <br />TO FACILITATE THE POSITIONING OF A TENSION TEST COLLAR. <br />B.TORQUE WRENCH METHOD: ANCHORS TESTED WITH A CALIBRATED TORQUE WRENCH MUST <br />ATTAIN THE SPECIFIED TORQUE WITHIN HALF (1/2) TURN OF THE NUT. <br />EXCEPTIONS: <br />·WEDGE OR SLEEVE TYPE: ONE-QUARTER (1/4) TURN OF THE NUT FOR A 3/8 INCH ANCHOR ONLY. <br />·THREADED TYPE: ONE-QUARTER (1/4) TURN OF THE SCREW AFTER INITIAL SEATING OF THE <br />SCREW HEAD. <br />10. IF ANY ANCHOR FAILS TESTING, TEST ALL ANCHORS OF THE SAME TYPE, INSTALLED BY THE SAME <br />TRADE, AND NOT PREVIOUSLY TESTED UNTIL TWENTY (20) CONSECUTIVE ANCHORS PASS, THEN <br />RESUME INITIAL TEST FREQUENCY. <br />SHEAR DOWELS 25% OF DOWELS (WHERE REQUIREMENTS OF THE <br />2022 CBC ARE MET) <br />1. ALL EXPANSION TYPE ANCHORS SHALL CONSIST OF HILTI KWIK BOLT TZ2 CONCRETE ANCHORS PER ICC ESR-4266 <br />REPORT. INSTALLATION SHALL BE IN CONFORMANCE WITH THE ICC REPORT. <br />2. ALL EPOXY TYPE ANCHORS SHALL CONSIST OF HILTI HIT HY-200 HYBRID ADHESIVE USED IN CONJUNCTION WITH <br />DEFORMED REINFORCING BARS PER ICC REPORT ESR-3187. INSTALLATION OF ANCHORS SHALL BE IN CONFORMANCE <br />WITH THE ICC REPORT. <br />3. WHEN INSTALLING DRILLED IN ANCHORS IN EXISTING NON-PRESTRESSED REINFORCED CONCRETE, USE CARE AND <br />CAUTION TO AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING BARS. <br />4. THE SPECIAL INSPECTOR MUST BE ON THE JOBSITE PERIODICALLY DURING ANCHOR INSTALLATION TO VERIFY ANCHOR <br />TYPE, ANCHOR DIMENSIONS, CONCRETE TYPE, CONCRETE COMPRESSIVE STRENGTH, PREDRILLED HOLE DIMENSIONS, <br />ANCHOR SPACING, EDGE DISTANCES, SLAB THICKNESS, ANCHOR EMBEDMENT AND TIGHTENING TORQUE. <br />5. TEST ALL POST-INSTALLED ANCHORS AS REQUIRED PER SECTION 1705 OF THE CODE. <br />6. ALL WEDGE ANCHORS SHALL BE CARBON STEEL, UNO. USE STAINLESS STEEL ANCHORS IN EXTERIOR EXPOSURE AND <br />DAMP ENVIRONMENTS. <br />7. INSTALL POST-INSTALLED ANCHORS IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AS DEFINED <br />IN THE ASSOCIATED IAPMO UES ER OR ICC ESR. <br />8. USE ONLY NON-REBAR CUTTING DRILL BITS TO DRILL HOLES IN CONCRETE, WHERE EXISTING CONCRETE IS DAMAGED <br />AND/OR DRILLED HOLES ABANDONED, THE DAMAGED CONCRETE OR ABANDONED HOLES SHALL BE REPAIRED OR <br />FILLED WITH NON-SHRINK GROUT, RESPECTIVELY, BRING EACH CONDITION TO THE ATTENTION OF THE ARCHITECT, <br />SEOR, AND UNIVERSITY BEFORE IMPLEMENTING REPAIRS. <br />POST INSTALLED CONCRETE ANCHORS <br />1. THE FOLLOWING ELEMENTS OF CONSTRUCTION SHALL HAVE CONTINUOUS INSPECTION BY A <br />PROJECT INSPECTOR APPROVED BY THE JURISDICTION. <br />A. CONCRETE. <br />B. BOLTS INSTALLED IN CONCRETE. <br />C. PLACING OF REINFORCING STEEL. <br />D. ALL STRUCTURAL WELDING, INCLUDING REINFORCING STEEL. <br />E. EXPANSION ANCHORS. <br />F. EPOXY ANCHORS. <br />G. POWDER ACTUATED FASTENERS/SHOT PINS. <br />H. HIGH STRENGTH BOLTS. <br />I. SEE GEOTECHNICAL ENGINEER'S REPORT FOR SPECIFIC INSPECTION REQUIREMENTS <br />BY A SOILS ENGINEER REPRESENTATIVE. <br />J. INSTALLATION OF METAL DECK HEADED STUDS. <br />K. NONDESTRUCTIVE TEST OF ALL CJP GROOVE WELDS. <br />2. ALL SPECIAL INSPECTIONS SHALL BE PERFORMED IN ACCORDANCE WITH THE <br />REQUIREMENTS OF SECTION 1704 OF THE CODE AND ANY ADDITIONAL REQUIREMENTS <br />STATED IN THESE DRAWINGS AND/OR THE PROJECT SPECIFICATIONS. <br />SPECIAL INSPECTIONS <br />PROJECT <br />COPYRIGHT LOC, INC <br />ORIGINAL SHEET SIZE: 42" X 30" <br />LOC <br />CLIEN <br />ARCHITEC <br />CONSULTANT <br />AC <br />C <br /> <br />R <br />e <br />v <br />i <br />t <br /> <br />2 <br />0 <br />2 <br />2 <br /> <br />h <br />o <br />s <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />L <br />O <br />C <br />2/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />1 <br />2 <br />: <br />0 <br />3 <br />: <br />2 <br />0 <br /> <br />P <br />M <br />Au <br />t <br />o <br />d <br />e <br />s <br />k <br /> <br />D <br />o <br />c <br />s <br />: <br />/ <br />/ <br />2 <br />3 <br />0 <br />8 <br />_ <br />S <br />A <br />Z <br />_ <br />H <br />i <br />v <br />e <br />/ <br />2 <br />3 <br />0 <br />0 <br />1 <br />7 <br />5 <br />_ <br />S <br />A <br />Z <br />_ <br />K <br />P <br />F <br />F <br />_ <br />R <br />2 <br />2 <br />. <br />r <br />v <br />t <br />2308 <br />GENERAL <br />NOTES <br />FEBRUARY 13, 2025 <br />PLAN CHECK <br />SUBMITTAL 02 <br />S0.03 <br />SANTA ANA ZOO <br />1801 E CHESTNUT AVE, SANTA ANA, CA <br />92701 <br />KPFF <br />STRUCTURAL ENGINEER <br />LOC ARCHITECTS <br />KPFF <br />CIVIL ENGINEER <br />BORDER <br />LANDSCAPE ARCHITECT <br />ABRARI AND ASSOCIATES <br />MEP ENGINEER <br />ASSOCIATED SOILS ENGINEERING <br />GEOTECHNICAL ENGINEER <br />700 S. FLOWER, SUITE 2100 <br />LOS ANGELES, CA 90017 <br />213 372 5111 <br />Ramzi.hodali@kpff.com <br />700 S. FLOWER, SUITE 2100 <br />LOS ANGELES, CA 90017 <br />213 372 5111 <br />Sharad.Ganju@kpff.com <br />724 S. SPRING ST, SUITE 701 <br />LOS ANGELES, CA 90014 <br />213 372 5111 <br />Darren@border-la.com <br />1713 S. STANDARD AVE <br />GLENDALE, CA 91201 <br />818 956 1900 <br />Telma@abrari.com <br />2860 WALNUT AVE. <br />SIGNAL HILL, CA 90755 <br />562 897 2749 <br />Ted@associatedsoils.com <br />3203 E. 4TH ST <br />LOS ANGELES, CA 90063 <br />213 537 0480 <br />Office@loc-arch.com <br />1801 E. CHESTNUT AVE. <br />SANTA ANA, CA 92701 <br />714 647 6575 <br />Efisher@santa-ana.org <br />SANTA ANA ZOO <br />EDUCATION <br />HUB <br />No.Description Date <br />REGISTERED PROFESSIONAL ENGINEERRAMZI S . HODAL <br />I <br />STRUC T URALSTATE OF CAL IFORNIA <br />2/13/2025