Laserfiche WebLink
NON-RATED INSTALLATION <br />RATED INSTALLATION <br />4" <br /> <br />M <br />A <br />X <br />4" <br /> <br />M <br />A <br />X <br />NON-RATED PARTITION PER PLAN <br />SCREW PER MANUFACTURER, TYP. <br />RECESSED TRIM <br />HANDLE <br />RATED PARTITION PER PLAN <br />CERTIFIED AND LISTED FIRE <br />RATED CABINET <br />SCREW PER MANUFACTURER, TYP. <br />RECESSED TRIM <br />HANDLE <br />ALIGN AND TAPE JOINT - TOP AND <br />SAND SMOOTH, BOTH SIDES <br />(E) WALL OR PARTITION - FIELD <br />VERIFY TYPE OF CONSTRUCTION <br />PARTITION PER PLAN <br />B1 - 2x6 WOOD STUDS @ 16" OC; <br />REFER TO STRUCTURAL DWGS. <br />B1b - (E) 2x WOOD STUDS <br />(1) LAYER OF 5/8" GYP BD BOTH <br />SIDES OF WALL <br />INTERIOR FINISH PER SCHED. <br />B1 -INTERIOR -NON-RATED PARTITION <br />PARTITION GENERAL NOTES: <br />1. DIMENSIONS ARE TO FACE OF FINISH, CENTERLINE OF STRUCTURAL COLUMNS, FACE OF FRAMING, UNLESS OTHERWISE NOTED. <br />2. FIRE-RESISTANCE RATING OF BUILDING ELEMENTS, COMPONENTS OR ASSEMBLIES SHALL BE DETERMINED BY THE TEST PROCEDURES SET FORTH IN UL <br />#U344 <br />3. THE PARTITION TYPE ABOVE OR BELOW ANY OPENING IS TO BE THE SAME AS THAT SCHEDULED FOR EACH SIDE OF THE OPENING. <br />4. DIFFERING PARTITION TYPES SHALL ALIGN SO THAT WALL PLANES CONTINUE UNBROKEN IN ROOMS, UNLESS OTHERWISE NOTED. <br />5. USE CEMENT BOARD (OR APPROVED TILE BACKING BOARD) AT "WET" AREAS. USE MOISTURE-AND MOLD-RESISTANT TYPE X AT WALLS NOT SCHEDULED TO <br />RECEIVE TILE AT TOILET ROOMS AND OTHER AREAS PRONE TO HUMIDITY. <br />6. REFER TO INTERIOR ELEVATIONS, INTERIOR FINISH SCHEDULE AND INTERIOR DETAILS FOR FINISHES, WALL COVERINGS, PANELS AND TRIMS. <br />7. PROVIDE BACKING AS REQUIRED FOR ALL WALL MOUNTED ELEMENTS. <br />8. FOR TYPICAL PARTITION DETAILS REFER TO: <br />BASE DETAIL: RATED HEAD DETAIL: NON-RATED HEAD DETAIL: <br />(E) 2x6 WOOD STUDS @ 16" OC; <br />REFER TO STRUCTURAL <br />DRAWINGS FOR ANY REPAIR <br />A1 - (1) LAYER OF 5/8" GYP <br />A1r - (1) LAYER OF 5/8" TYPE "X" <br />GYP BD (1 HOUR RATED) <br />INTERIOR FINISH PER SCHED. <br />A1 -EXTERIOR -PLASTER TO GYP BD <br />(E) 1X6 SHEATHING; REFER TO <br />STRUCTURAL DRAWINGS FOR <br />ANY REPAIR <br />(E) PLASTER; PATCH AND REPAIR <br />PLASTER FINISH AS REQUIRED, ALL <br />NEW MATERIALS SHALL MATCH <br />ORIGINAL AS CLOSE AS POSSIBLE IN <br />FINISH AND TEXTURE <br />R-19 BATT INSULATION <br />(E) 2x6 WOOD STUDS @ 16" OC; <br />REFER TO STRUCTURAL DWGS. <br />FOR ANY REPAIR <br />(1) LAYER OF 5/8" GYP <br />A2r & A2br - (1) LAYER OF 5/8" TYPE "X" <br />GYP BD (1 HOUR RATED) <br />INTERIOR FINISH PER <br />SCHED. <br />A2 -EXTERIOR SHEAR WALL -PLASTER TO GYP BD <br />(E) 1X6 SHEATHING; REFER TO <br />STRUCTURAL DWGS. FOR ANY REPAIR <br />(E) PLASTER; PATCH AND REPAIR PLASTER <br />FINISH AS REQUIRED, ALL NEW MATERIALS <br />SHALL MATCH ORIGINAL AS CLOSE AS <br />POSSIBLE IN FINISH AND TEXTURE <br />R-19 BATT INSULATION <br />(E) 2x6 WOOD STUDS @ 16" OC; <br />REFER TO STRUCTURAL <br />DRAWINGS FOR ANY REPAIR <br />A3 -EXTERIOR -PLASTER TO TILE <br />(E) 1X6 SHEATHING; REFER TO <br />STRUCTURAL DRAWINGS FOR <br />ANY REPAIR <br />(E) PLASTER; PATCH AND REPAIR <br />PLASTER FINISH AS REQUIRED, ALL <br />NEW MATERIALS SHALL MATCH <br />ORIGINAL AS CLOSE AS POSSIBLE IN <br />FINISH AND TEXTURE <br />R-19 BATT INSULATION <br />A2 - PLYWOOD SHEAR WALL, REFER TO <br />STRUCT. DWGS. <br />A2b (NON-SHEAR WALL) - ADD SHEATHING <br />TO ALIGN WALL FINISHES WITH ADJACENT <br />SHEAR WALL <br />(E) 2x6 WOOD STUDS @ 16" OC; <br />REFER TO STRUCTURAL DWGS. <br />FOR ANY REPAIR <br />A4 -EXTERIOR SHEAR WALL -PLASTER TO TILE <br />(E) 1X6 SHEATHING; REFER TO <br />STRUCTURAL DWGS. FOR ANY REPAIR <br />(E) PLASTER; PATCH AND REPAIR PLASTER <br />FINISH AS REQUIRED, ALL NEW MATERIALS <br />SHALL MATCH ORIGINAL AS CLOSE AS <br />POSSIBLE IN FINISH AND TEXTURE <br />R-19 BATT INSULATION <br />A4 - PLYWOOD SHEAR WALL, REFER TO <br />STRUCT. DWGS. <br />A4b (NON-SHEAR WALL) - ADD SHEATHING <br />TO ALIGN WALL FINISHES WITH ADJACENT <br />SHEAR WALL <br />CERAMIC TILE <br />OVER BOND <br />COAT OVER <br />MORTAR BED; <br />TILE LOCATIONS <br />PER INT. <br />ELEVATIONS <br />CERAMIC TILE <br />OVER BOND <br />COAT OVER <br />MORTAR BED; <br />TILE LOCATIONS <br />PER INT. <br />ELEVATIONS <br />2x6 WOOD STUDS @ 16" OC; <br />REFER TO STRUCTURAL DWGS. <br />(1) LAYER OF 5/8" GYP BD <br />INTERIOR FINISH PER SCHED. <br />B3 -INTERIOR -NON-RATED PARTITION, TILE <br />2x6 WOOD STUDS @ 16" OC; <br />REFER TO STRUCTURAL DWGS. <br />(1) LAYER OF 5/8" GYP BD BOTH <br />SIDES OF WALL <br />INTERIOR FINISH PER SCHED. <br />B2 -INTERIOR -NON-RATED SHEAR WALL <br />B2 - PLYWOOD SHEAR WALL, REFER TO <br />STRUCT. DWGS. <br />B2b (NON-SHEAR WALL) - ADD SHEATHING <br />TO ALIGN WALL FINISHES WITH ADJACENT <br />SHEAR WALL <br />2x6 WOOD STUDS @ 16" OC; <br />REFER TO STRUCTURAL DWGS. <br />(1) LAYER OF 5/8" GYP BD BOTH <br />SIDES OF WALL <br />INTERIOR FINISH PER SCHED. <br />B4 -INTERIOR -NON-RATED SHEAR WALL, TILE <br />PLYWOOD SHEAR WALL, REFER TO <br />STRUCT. DWGS. <br />(1) LAYER OF 5/8" <br />TYPE "X" GYP BD/ <br />CEMENT BOARD <br />CERAMIC TILE <br />OVER BOND <br />COAT OVER <br />MORTAR BED; <br />TILE LOCATIONS <br />PER INT. <br />ELEVATIONS <br />(1) LAYER OF 5/8" <br />TYPE "X" GYP BD/ <br />CEMENT BOARD <br />CERAMIC TILE <br />OVER BOND <br />COAT OVER <br />MORTAR BED; <br />TILE LOCATIONS <br />PER INT. <br />ELEVATIONS <br />2x6 WOOD STUDS @ 16" OC; <br />REFER TO STRUCTURAL DWGS. <br />B5 -INTERIOR -NON-RATED PARTITION, TILE BOTH SIDES <br />(1) LAYER OF 5/8" TYPE "X" <br />GYP BD/ CEMENT BOARD, <br />BOTH SIDE OF WALL <br />CERAMIC TILE OVER BOND COAT <br />OVER MORTAR BED, BOTH SIDE <br />OF WALL; TILE LOCATIONS PER <br />INT. ELEVATIONS <br />2 ROWS OF 2x6 WOOD STUDS <br />@ 16" OC; <br />REFER TO STRUCTURAL <br />DWGS. <br />(1) LAYER OF 5/8" GYP BD <br />INTERIOR FINISH PER SCHED. <br />C1 -INTERIOR -CAVITY WALL, TILE <br />(1) LAYER OF 5/8" <br />TYPE "X" GYP BD/ <br />CEMENT BOARD <br />CERAMIC TILE <br />OVER BOND <br />COAT OVER <br />MORTAR BED; <br />TILE LOCATIONS <br />PER INT. <br />ELEVATIONS <br />REFER TO PLAN <br />VARIES <br />2 ROWS OF 2x6 WOOD STUDS <br />@ 16" OC; <br />REFER TO STRUCTURAL <br />DWGS. <br />C2 -INTERIOR -CAVITY WALL, TILE BOTH SIDES <br />REFER TO PLAN <br />VARIES <br />(1) LAYER OF 5/8" TYPE "X" <br />GYP BD/ CEMENT BOARD, <br />BOTH SIDE OF WALL <br />CERAMIC TILE OVER BOND COAT <br />OVER MORTAR BED, BOTH SIDE <br />OF WALL; TILE LOCATIONS PER <br />INT. ELEVATIONS <br />2 ROWS OF 2x6 WOOD STUDS <br />@ 16" OC; <br />REFER TO STRUCTURAL <br />DWGS. <br />C3 -INTERIOR -SHEAR CAVITY WALL, TILE BOTH SIDES <br />REFER TO PLAN <br />VARIES <br />(1) LAYER OF 5/8" TYPE "X" GYP BD/ <br />CEMENT BOARD, BOTH SIDE OF <br />WALL <br />CERAMIC TILE OVER BOND COAT <br />OVER MORTAR BED, BOTH SIDE <br />OF WALL; TILE LOCATIONS PER <br />INT. ELEVATIONS <br />C3 - PLYWOOD SHEAR WALL, <br />REFER TO STRUCT. DWGS. <br />C3b (NON-SHEAR WALL) - ADD <br />SHEATHING TO ALIGN WALL <br />FINISHES WITH ADJACENT SHEAR <br />WALL <br />A3 - (1) LAYER OF 5/8" <br />GYP/ CEMENT BD. <br />A3r - (1) LAYER OF <br />5/8" TYPE "X" GYP BD <br />(1 HOUR RATED) <br />A4 - (1) LAYER OF 5/8" <br />GYP/ CEMENT BD. <br />A4r - (1) LAYER OF <br />5/8" TYPE "X" GYP BD <br />(1 HOUR RATED) <br />9 <br />A5.03 <br />15 <br />A5.03 <br />10 <br />A5.03 <br />A: PERPENDICULAR TO FRAMING B: PARALLEL TO FRAMING <br />ROOF MEMBRANE ASSEMBLY <br />OVER PLYWOOD SHEATHING <br />(E) 1x6 SHEATHING <br />(E) ROOF TRUSS, VIF <br />WOOD BLOCKING <br />1x6 SHEATHING <br />(E) 2x6 WALL FRAMING, VIF; <br />PROVIDE FRAMING AS <br />REQUIRED FOR 1x6 SHEATHING <br />IF (E) FRAMING DOESN'T EXIST <br />PICTURE MOLDING <br />5/8" GYP BD <br />ROOF MEMBRANE <br />ASSEMBLY OVER <br />PLYWOOD SHEATHING <br />(E) 1x6 SHEATHING <br />(E) ROOF TRUSS, VIF <br />1x6 SHEATHING <br />PICTURE MOLDING <br />5/8" GYP BD 2x6 WALL FRAMING; <br />COORDINATION REQUIRED FOR <br />ATTACHMENT WITH NEW <br />STRUCTURAL ROOF AND CEILING <br />FRAMING, EXCAT LOCATION TO BE <br />REVIEWED IN THE FEILD, <br />ADDITIONAL FRAMING MAY BE <br />REQUIRED FOR 1x6 SHEATHING <br />PER PLAN <br />WALL TYPE <br />WALL FINISH PER SCHEDULE <br />WALL BASE PER SCHEDULE <br />FLOOR FINISH PER SCHEDULE <br />1/2" DIA. SIMP. TITEN HD SCREW <br />ANCHORS 3 1/4" MIN. EMBED @ <br />4'-0" O.C. U.O.N. <br />1/2" MIN JOINT SEALANT PERIMETER <br />AND EACH SIDE OF WALL, AT FIRE <br />RATED WALLS USE UL CLASSIFIED <br />FIRESTOP, ALL OTHER WALLS USE <br />ACOUSTICAL SEALANT, TYP. <br />PARTITION PERPENDICULAR TO JOIST PARTITION PARALLEL TO JOIST <br />CEILING RAFTERS/JOIST, <br />REFER TO STRUCTURAL <br />DOUBLE TOP PLATES <br />PER PLAN <br />WALL TYPE <br />PER PLAN <br />WALL TYPE <br />2x BLOCKING, REFER TO <br />STRUCTURAL DWG. <br />GA <br />P <br />1/ <br />2 <br />" <br />DEFLECTOR SCREW, REFER TO <br />STRUCTURAL DETAIL 2/S0.23 <br />DEFLECTOR SCREW, REFER TO <br />STRUCTURAL DETAIL 2/S0.23 <br />CEILING RAFTERS/JOIST, <br />REFER TO STRUCTURAL <br />DOUBLE TOP PLATES <br />GA <br />P <br />1/ <br />2 <br />" <br />NOTES <br />1. RATED GYPSUM WALL BOARD ASSEMBLY <br />2. METAL STUDS <br />3. STEEL OR IRON PIPE, CONDUIT, OR EMT. <br />4. STEEL, IRON OR COPPER PIPE OR CONDUIT. <br />5. STTEL OR COPPER PIPE WITH UP TO 1" FIBERGLASS OR MINERAL <br />WOOL INSULATION. <br />6. PVC 2" CLOSED PIPE OR CONDUIT. <br />7. ELECTRICAL, TELEPHONE OR DATA CABLES. NOTE: ROMEX CABLE <br />IS APPROVED FOR USE IN THIS SYSTEM. <br />8. SPECSEAL SERIES 100 SEALANT INSTALLED TO A 1 1/4" DEPTH <br />AROUND PERIMETER OF OPENING. <br />9. MINERAL WOOL BATT NOMINAL 6 PCL. TO FULL WALL THICKNESS <br />RECESSED FROM BOTH SIDES TO ACCOMMODATE FILL MATERIAL. <br />FIRESTOP FOR MULTIPLE PIPE AND CABLES THROUGH GYP. BD. <br />WALLS USING SpecSeal SERIES 100 SEALANT. <br />PER UL# W-L-8003 <br />1 15/16" MAX. <br />5/8" MIN. <br />1 4 5 6 7 <br />8 <br />3 8 2 <br />9 <br />3 <br />4 <br />5 <br />6 <br />7 <br />1 <br />A5.05 <br />2 <br />(E) TRUSS CHORD BEYOND, VIF <br />ROOF JOIST, PER STRUCTURAL DWGS <br />(E) TRUSS CHORD BEYOND, VIF <br />CEILING JOIST PER STRUCTURAL DWG <br />ROOF ASSEMBLY <br />(E) TOP PLATES <br />(E) PLASTER AND <br />WOOD SEATHING <br />1 <br />A5.05 <br />1/2" MIN JOINT SEALANT PERIMETER <br />AND EACH SIDE OF WALL, AT FIRE <br />RATED WALLS USE UL CLASSIFIED <br />FIRESTOP, ALL OTHER WALLS USE <br />ACOUSTICAL SEALANT, TYP. <br />1/2" MIN JOINT SEALANT @ PERIMETER <br />PENETRATIONS, AT FIRE RATED WALLS <br />USE UL CLASSIFIED FIRESTOP <br />5/8" GYP BD CEILING <br />5/8" TYPE "X" <br />GYP BD, TYP. <br />PER PLAN <br />WALL TYPE <br />R-19 BATT <br />INSULATION <br />Scale <br />Project number <br />Date <br />Drawn by <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />JD/AP <br />As indicated <br />4/ <br />7 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />9 <br />: <br />2 <br />2 <br />: <br />2 <br />5 <br /> <br />P <br />M <br />A5.03 <br />WALL TYPES & <br />DETAILS <br />23004 <br />CYPRESS CENTER <br />RESTORATION <br />CITY OF SANTA ANA <br />1/17/2025 <br />625 S. CYPRESS AVE. <br />SANTA ANA, CA 92701 <br />1 1/2" = 1'-0"A5.03 <br />20 PARTITION RECESS, TYPICAL <br />3" = 1'-0"A5.03 <br />19 PARTITION TO (E) WALL <br />1 1/2" = 1'-0"A5.03 <br />5 WALL TYPES <br />1 1/2" = 1'-0"A5.03 <br />16 TOP OF WALL SHEATHING DETAIL @ MULTIPURPOSE RM A <br />3" = 1'-0"A5.03 <br />9 WALL BASE <br />3" = 1'-0"A5.03 <br />15 NON-RATED WALL HEAD <br />No. Description Date <br />75% CD 3/15/2024 <br />90% CD 5/14/2024 <br />PERMIT SET 5/17/2024 <br />OCFA SUBMITTAL 9/26/2024 <br />BACKCHECK SET 1/17/2024 <br />BACKCHECK SET_V2 4/8/2025 <br />1" = 1'-0"A5.03 <br />17 RATED FIRESTOP <br />1" = 1'-0"A5.03 <br />10 1-HOUR RATED WALL HEAD