2"x WD. STUDS PER PLAN <br />5/8" GYP. BOARD <br />PAINT PER FINISH SCHED. <br />CONT. BLOCKING <br />WALL <br />FINISH <br />PER <br />SCHED. <br />2"x WOOD CLNG. <br />JOIST @ 16" O.C. <br />CROSS TEES <br />AT 24" O.C. <br />MAIN RUNNERS <br />AT 48" O.C. <br />FIXTURES, SUPPORT <br />PER NOTES, TYP. <br />OPPOSITE FREE WALLS, <br />NO GRID ATTACHMENT, <br />3/4" MIN. CLEAR <br />12 GA.HANGER WIRES <br />AT 8" FROM ALL WALLS <br />AT ALL MAIN RUNNERS <br />AND CROSS TEES <br />12 GA. HANGER WIRES <br />AT 4'-0" O.C. EACH WAY <br />ALONG MAIN RUNNERS <br />STRUT AT FREE WALLS <br />4 EA. 12 GA. SPLAY <br />WIRES. <br />PERIMETER STARTER WALLS, <br />GRID ATTACHED TO (2) ADJACENT <br />WALLS <br />A <br />B <br />6 <br />A5.04 <br />6 <br />A5.04 <br />12 <br />A5.04 <br />10 <br />A5.04 <br />8 <br />A5.04 <br />12 <br />" <br /> <br />M <br />I <br />N <br />CLR <br />3/4" MIN <br />1/4" LENGTH <br />OF END <br />RUNNER <br />WHICHEVER <br />IS LEAST <br />U. <br />N <br />. <br />O <br />WALL FINISH CONTINUES <br />WHERE OCCURS <br />12 GA. HANGER WIRES, TYP. <br />MIN. 3 TIGHT TURNS <br />MAIN "T" RUNNERS AT 48" O.C. <br />CROSS "T" AT 24" O.C. <br />ACOUSTICAL LAY-IN PANEL <br />POP RIVET PERIMETER ANGLE TO EA. <br />TEE RUNNER INTERSECTION @ <br />RESTRAINED WALLS <br />WALL ANGLE ATTACHED TO WALL W/ <br />#10 X 1-1/2"" WOOD SCREWS @ 16" <br />O.C. OR 6d X 1-1/2" L. NAILS ON 16 O.C. <br />2X BLOCKING PER STRUCT. DRAWINGS <br />RESTRAINED END <br />PERIMETER STARTER WALLA <br />C SECTION <br />"T" RUNNER <br />ACOUSTICAL LAY-IN <br />PANEL <br />'V" STRUTT <br />DRILL HOLE IN RUNNER & INSTALL 6d <br />RING SHANK NAIL <br />OR WITHIN <br />1/4" OF THE <br />LENGTH OF <br />END RUNNER <br />WHICHEVER <br />IS LESS <br />WALL FINISH CONTINUES WHERE <br />OCCURS <br />12 GA. HANGER WIRES, WITH TYP. MIN. <br />3 TIGHT TURNS IN 1-1/2" <br />T-RUNNERS <br />ACOUSTICAL LAY-IN PANEL <br />WALL ANGLE ATTACHED TO WALL W/ <br />#10 X 1-1/2"" WOOD SCREWS @ 16" <br />O.C. OR 6d X 1-1/2" L. NAILS ON 16 O.C. <br />2X BLOCKING PER STRUCT. DRAWINGS <br />B FREE END <br />C <br />INTERLOCK 'V' STRUTS OR HORIZ. <br />16" GA. TIE WIRE @ WALLS <br />OPPOSITE POP RIVETED WALLS <br />NOTE: <br />1. WHERE THE PERPENDICULAR DISTANCE FROM THE WALL TO THE FIRST <br /> PARALLEL MAIN RUNNER IS 8" OR LESS, THIS INTERLOCK IS NOT REQD. <br />2. NAILS @ THE END OF HORIZ. STRUTS ARE TO BE PLACED WITH NAIL HEAD <br /> TOWARD CENTERLINE OF SPAN OF STRUT. <br />8" MAX <br />8" MAX. <br />U. <br />N <br />. <br />O <br />. <br />12 <br />" <br /> <br />M <br />I <br />N <br />. <br />1/4" DIA. EYE-SCREW W/ 1-1/2" <br />PENETRATION <br />TYP. BRACING WIRE W/ 4 <br />TIGHTS TURNS WITHIN 1-1/2" <br />3" <br />MA <br />X <br />FOR BRACING WIRES FULLY EMBED <br />EYE-SCREW SHANK IN DIRECTION OF <br />WIRE W/ 4 TIGHT TURNS WITHIN 1-1/2", <br />1-1/2" PENETRATION INTO JOISTS <br />3" <br />2" <br />MI <br />N <br />. <br />WOOD JOIST <br />OR RAFTER <br />BOTTOM OF <br />JOIST <br />A <br />B <br />MAIN RUNNER <br />ACOUSTICAL CEILING <br />#12 TEKS HEX HEAD <br />SELF DRILLING <br />FASTENERS AT 18" O.C. <br />STEEL STUD <br />COMPRESSION <br />STRUT, <br />SEE SCHEDULE <br />(2) #8 x 1-1/4" GALV. <br />WOOD SCREWSREMOVE <br />FLANGES AND <br />BEND WEB <br />HORIZONTAL <br />2X4 BLOCKING W/ <br />(2) 16d NAILS AT <br />EACH END <br />ROOF FRAMING <br />STEEL STUD COMPRESSION <br />STRUT SCHEDULE <br />LENGTH <br />OF STRUT <br />UP T0 2'-6" <br />2'-7" TO 4'-6" <br />4'-7" TO 9'-6" <br />9'-7" TO 16'-6" <br />STRUT SIZE 18 GA, CEE <br />STUDS W/ 1 5/8" FLANGES <br />2 1/2" CEE CEE METAL <br />STUDS <br />2 1/2" CEE CEE <br />METAL STUDS <br />4" CEE CEE <br />METAL STUDS <br />4" CEE CEE <br />METAL STUDS <br />PROVIDE (4) <br />SIMPSON <br />A34. (2) ON EACH <br />SIDE OF EACH <br />END <br />NOTE: <br />1. COMPRESSION STRUT SHALL NOT <br />REPLACE HANGER WIRES <br />STEEL "CEE" <br />STUDS <br />#12 TEKS HEX <br />HEAD SELF <br />DRILLING <br />FASTENERS <br />AT 18" O.C. <br />12 GA. VERTICAL HANGER WIRE <br />@ 4'-0" EA. WAY (4'-0" O.C. @ MAIN <br />RUNNER) MIN 3 TIGHT TURNS IN <br />3" BOTH ENDS OF WIRE, TYP. <br />LATERAL FORCE BRACE <br />ASSEMBLY SHALL BE 8' X 12' O.C. <br />45° MAX TYP. <br />COMPRESSION STRUTS <br />STEEL SECTION WITH L/R RATIO OF 200 MAX. <br />ATTACH TO MAIN RUNNERS WITH 1/4" MACHIME-BOLT <br />AND TO STRUCTURE WITH 3/16" DIAMETER ANCHOR <br />AT CONCRETE / STEEL COMPRESSION STRUT SHALL <br />NOT REPLACE HANGER WIRE <br />(4)-12 GA. SPLAYED WIRES 90° <br />APART HORIZONTALLY WITH MIN. <br />4 TIGHT TURNS IN 1-1/2" BOTH <br />ENDS OF WIRE, TYP. WIRES <br />SHOULD BE TAUT WITHOUT <br />CAUSING THE CEILING TO LIFE <br />NO SPLICES PERMITTED <br />MAIN RUNNER <br />CROSS RUNNER <br />2" MAX FROM BRACING <br />WIRES TO CROSS RUNNERS <br />& COMPRESSION STRUTT <br />10 <br />A5.04 <br />NOTE: <br />FOR CONNECTIONS OF BRACING & <br />HANGER WIRES THE STRUCTURE <br />ABOVE, SEE DETAIL <br />11 <br />A5.04 <br />45.00°TYP <br /> <br /> <br />45° TYP <br />MIN. (4) 12 GA. VERTICAL HANGER <br />WIRES @ EA. LIGHT FIXTURE, AIR <br />TERMINAL SERVICES OR ITEMS <br />WEIGHING 56 lbs OR MORE ATTACH <br />TO STRUCTURE ABOVE, SEE DETAIL <br />4 WIRES-12 GA. BRACING FOR <br />FIXTURES, AIR TERMINALS, SERVICES <br />OR ITEMS WEIGHING LESS THAN 56 lbs <br />PER METAL SUSPENSION SYSTERMS <br />FOR LAY-IN PANEL CEILINGS NOTE #6 <br />1 #8 S.M.S. (TOTAL OF 2 SCREWS) <br />IN OPPOSITE SIDES, LOCATE SCREWS <br />NEAR THE CENTER OF TERMINAL <br />OF FIXTURE <br />11 <br />A5.04 <br />Scale <br />Project number <br />Date <br />Drawn by <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />JD/AP <br />As indicated <br />4/ <br />7 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />9 <br />: <br />2 <br />2 <br />: <br />2 <br />7 <br /> <br />P <br />M <br />A5.04 <br />CEILING DETAILS <br />23004 <br />CYPRESS CENTER <br />RESTORATION <br />CITY OF SANTA ANA <br />1/17/2025 <br />625 S. CYPRESS AVE. <br />SANTA ANA, CA 92701 <br />6" = 1'-0"A5.04 <br />1 GYPSUM BOARD CEILING <br />1. SUSPENSION LAY-IN CEILING SHALL BE CONTRACTOR DESIGN/BUILD. <br />2. PROVIDE HANGER WIRES ALONG MAIN RUNNERS. PROVIDE HANGER WIRES AT THE ENDS OF ALL <br />MAIN AND CROSS RUNNERS, AT THE PERIMETER OF THE CEILING AREA. <br />3. PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS TO <br />MAIN HANGER SPACING. PROVIDE ADDITIONAL HANGERS, STRUTS OR BRACES AS REQUIRED AT <br />ALL CEILING BREAKS, SOFFITS OR DISCONTINUOUS AREA. HANGER WIRES THAT ARE OUT OF <br />PLUMB ARE TO HAVE COUNTER-SLOPING WIRES. <br />4. CEILING GRID MEMBERS MAY BE ATTACHED TO ADJACENT WALLS. CEILING GRID MEMBERS <br />SHOULD BE AT LEAST 1/2" FREE OF OTHER WALLS. IF WALLS RUN DIAGONALLY TO CEILING GRID <br />SYSTEM RUNNERS, ONE END OF MAIN AND CROSS RUNNERS SHOULD BE FREE AND A MINIMUM <br />OF 1/2" CLEAR OF WALL. <br />5. AT THE PERIMETER OF THE CEILING AREA WHERE MAIN OR CROSS RUNNERS ARE NOT <br />CONNECTED TO THE ADJACENT WALL, PROVIDE INTERCONNECTIONS BETWEEN THE RUNNERS <br />AT THE FREE END TO PREVENT LATERAL SPREADING. A METAL STRUT OR A WIRE WITH A <br />POSITIVE MECHANICAL CONNECTION TO THE RUNNER MAY BE USED. <br />6. PROVIDE SETS OF SPLAYED BRACING WIRES ORIENTED 90 DEGREES FROM EACH OTHER. <br />PROVIDE BRACING WIRES AT LOCATIONS FROM EACH PERIMETER WALL AND AT THE EDGE OF <br />VERTICAL CEILING OFFSETS. THE SLOPE OF THESE WIRES SHOULD NOT EXCEED 45 DEGREES <br />FROM THE PLANE OF THE CEILING AND SHOULD BE TAUT WITHOUT CAUSING THE CEILING TO <br />LIFT. SPLICES IN BRACING WIRES ARE NOT TO BE PERMITTED WITHOUT APPROVAL. <br />7. FASTEN HANGER AND BRACING WIRES, HANGER OR BRACING WIRE ANCHORS TO THE <br />STRUCTURE SHOULD BE INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE WIRE <br />ALIGNS AS CLOSELY AS POSSIBLE WITH THE DIRECTION OF THE FORCES ACTING ON THE WIRE. <br />8. SEPARATE ALL CEILING BRACING WIRES FROM ALL UNBRACED DUCTS, PIPES, CONDUIT, ETC. IT <br />IS ACCEPTABLE TO ATTACH LIGHTWEIGHT ITEMS, SUCH AS SINGLE ELECTRICAL CONDUIT. <br />9. WHEN DRILLED-IN CONCRETE ANCHORS ARE USED IN REINFORCED CONCRETE FOR HANGER <br />WIRES, 1 OUT OF 10 MUST BE FIELD TESTED BY TESTING LABORATORY FOR 200 POUNDS OF <br />TENSION. WHEN FILLED-IN CONCRETE ANCHORS ARE USED FOR BRACING WIRES, 1 OUT OF 2 <br />MUST BE FIELD TESTED BY TESTING LABORATORY FOR 440 POUNDS IN TENSION. NO SHOT-IN <br />ANCHORS ARE PERMITTED. <br />10. ATTACHED ALL LIGHT FIXTURES TO THE CEILING GRID SYSTEM POSITIVELY. ATTACHMENT <br />DEVICE SHALL HAVE A CAPACITY OF 100 PERCENT OF THE LIGHTING FIXTURE WEIGHT ACTING IN <br />ANY DIRECTION. <br />11. FLUSH OR RECESSED LIGHT FIXTURES AND AIR TERMINALS OR SERVICES WEIGHING LESS THAN <br />56 POUNDS MAY BE SUPPORTED DIRECTLY ON THE RUNNERS OF A HEAVY DUTY GRID SYSTEM <br />BUT THEY MUST HAVE SAFETY WIRES ATTACHED TO THE FIXTURE AT DIAGONAL CORNERS AND <br />ANCHORED TO THE STRUCTURE ABOVE. ALL 4 FT. X 4 FT. RECESSED LIGHT FIXTURES AND AIR <br />TERMINALS OR SERVICES WEIGHING 56 POUNDS OR MORE MUST BE INDEPENDENTLY <br />SUPPORTED BY WIRES EACH ATTACHED TO THE FIXTURE AND THE THE STRUCTURE ABOVE <br />REGARDLESS OF THE TYPE OF CEILING GRID SYSTEM USED. THE WIRES INCLUDING THEIR <br />ATTACHMENT TO THE STRUCTURE ABOVE MUST BE CAPABLE OF SUPPORTING 4 TIMES THE <br />WEIGHT OF THE UNIT. <br />12. ALL FIXTURES AND AIR TERMINALS OR SERVICES SUPPORTED ON INTERMEDIATE DUTY GRID <br />SYSTEMS MUST BE INDEPENDENTLY SUPPORTED BY WIRES EACH ATTACHED TO THE FIXTURE <br />OR TERMINAL AND TO THE STRUCTURE ABOVE. <br />13. SUPPORT SURFACE MOUNTED LIGHT FIXTURES BY AT LEAST TWO POSITIVE DEVICES WHICH <br />SURROUND THE CEILING RUNNER AND WHICH ARE EACH SUPPORTED FROM THE STRUCTURE <br />ABOVE BY WIRE. SPRING CLIPS OR CLAMPS THAT CONNECT ONLY TO THE RUNNER ARE NOT <br />ACCEPTABLE. PROVIDE ADDITIONAL SUPPORTS WHEN LIGHT FIXTURES ARE LONGER. <br />14. SUPPORT PENDANT MOUNTED LIGHT FIXTURES DIRECTLY FROM THE STRUCTURE ABOVE WITH <br />HANGER WIRES OR CABLES PASSING THROUGH EACH PENDANT HANGER AND CAPABLE OF <br />SUPPORTING 4 TIMES THE WEIGHT OF THE FIXTURE. SPECIAL DETAILS ARE NECESSARY FOR <br />THIS CONDITION AT THE CEILING GRID. <br />15. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE SHALL NOT BE LESS THAN 2". IN EACH <br />ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE ATTACHED TO <br />THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE A 0.75" <br />CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE <br />ANGLE. <br />16. FOR CEILING AREAS EXCEEDING 2,500 S.F., A SEISMIC SEPARATION JOINT OR FULL HEIGHT <br />PARTITION THAT BREAKS THE CEILING UP IN TO AREAS NOT EXCEEDING 2,500 S.F. SHALL BE <br />PROVIDED. EACH AREA SHALL BE PROVIDED WITH CLOSURE ANGLES. <br />17. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTIONS, SPRINKLER HEADS <br />AND OTHER PENETRATIONS, A 2" OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING <br />TILE SHALL BE USED TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL <br />DIRECTIONS. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1" OF CEILING <br />MOVEMENT IN ALL HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT THE TOP OF THE <br />SPRINKLER HEAD EXTENSION. <br />18. LATERAL BRACING FOR SUSPENDED CEILING SHALL BE PROVIDED. WHERE CEILING IS NOT <br />SUPPORTED BY INTERIOR PARTITIONS, CEILING BRACING SHALL BE PROVIDED BY FOUR NO. 12 <br />GAUGE WIRES SECURED TO THE MAIN RUNNER WITHIN 2 INCHES ON THE CROSS RUNNER <br />INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING 45 <br />DEGREES FROM THE PLANE OF THE CEILING. A STRUT FASTENED TO THE MAIN RUNNER SHALL <br />BE EXTENDED TO AND FASTENED TO THE STRUCTURAL MEMBERS OF THE ROOF FLOOR ABOVE. <br />THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACE 12 FEET O.C. IN BOTH DIRECTIONS <br />WITH THE FIRST POINT WITHIN 6 FEET OF EACH WALL. ATTACHMENT OF RESTRAINT WIRES TO <br />THE STRUCTURE ABOVE SHALL BE ADEQUATE FOR THE LOAD IMPOSED. <br />SUSPENDED ACOUSTICAL CEILING NOTES <br />3/16" = 1'-0"A5.04 <br />2 LAY-IN CEILING REQUIREMENTS <br />1 1/2" = 1'-0"A5.04 <br />6 CEILING PERIMETER WALL ANGLES <br />3" = 1'-0"A5.04 <br />11 WIRE TO WD. FRAMING CONN. <br />1 1/2" = 1'-0"A5.04 <br />10 CEILING COMPRESSION STRUT <br />1/4" = 1'-0"A5.04 <br />12 CEILING SPLAY BRACKING <br />1/4" = 1'-0"A5.04 <br />8 FIXTURE SUPPORT <br />No. Description Date <br />90% CD 5/14/2024 <br />PERMIT SET 5/17/2024 <br />OCFA SUBMITTAL 9/26/2024 <br />BACKCHECK SET 1/17/2024 <br />BACKCHECK SET_V2 4/8/2025