TYPE A
<br />FIXED
<br />REMARKS
<br />1.
<br />2.
<br />3.
<br />4.
<br />5.
<br />6.
<br />7.
<br />8.
<br />9.
<br />10.
<br />TYPE B
<br />DOUBLE HUNG
<br />TYPE C
<br />DOUBLE HUNG
<br />WITH TRANSOM
<br />TYPE D
<br />FIXED ARCHED
<br />NOTE:
<br />WHERE ORIGINAL MATERIALS REMAIN AND ARE SALVAGEABLE, ORIGINAL
<br />MATERIALS SHALL BE REPAIRED AS NEEDED. IF DETERIORATION IS BEYOND
<br />REPAIR OR ORIGINAL BUILDING FEATURES ARE MISSING, ALL NEW
<br />MATERIALS SHALL MATCH ORIGINALS AS CLOSE AS POSSIBLE AND MEET
<br />THE SECRETARY OF THE INTERIOR'S STANDARDS FOR REHABILITATION.
<br />ANY EXISTING DETAIL OR FEATURE INCLUDING PROFILES, WINDOW LUGS,
<br />HARDWARE, ETC IS TO BE RESTORED AND REUSED IF INTACT OR
<br />RECREATED TO MATCH ORIGINAL IF MISSING.
<br />GLAZING AT WINDOWS TO BE TRUE DIVIDED LITES WHERE OCCURS.
<br />LABEL, BUNDLE, & BAG ALL SALVAGED HARDWARE TO CORRESPOND TO
<br />DOOR SCHEDULE. STRIP & CLEAN SALVAGED HARDWARE AS NEEDED FOR
<br />REUSE.
<br />REFER TO SHEET A6.01 EXISTING WINDOW INVENTORY FOR ADDITIONAL
<br />REFERENCE.
<br />ALL WINDOWS TO HAVE INTERIOR MOUNTED MANUAL ROLLER SHADES.
<br />TYPE E
<br />CASEMENT
<br />WINDOW FRAME DAMAGED BEYOND REPAIR. REBUILD TO MATCH
<br />ORIGINAL.
<br />CASING DAMAGED BEYOND REPAIR. REBUILD TO MATCH ORIGINAL.
<br />SALVAGE & REUSE (E) HARDWARE. MATCH ORIGINAL WHERE MISSING.
<br />NEW WINDOW TO MATCH ORIGINAL IN (E) OPENING.
<br />IF MATERIAL IS SALVAGEABLE. RELOCATE AS NOTED ON PLANS &
<br />ELEVATIONS. NOTIFY ARCHITECT AND OWNER IF FRAMES OR CASING
<br />CANNOT BE REUSED.
<br />SALVAGE AND RESTORE INTACT ORIGINAL MATERIAL. NOTIFY ARCHITECT
<br />IF SPECIFIC COMPONENTS CANNOT BE REUSED.
<br />INSTALL NEW CROWN CASING TO MATCH ORIGINAL WHERE MISSING.
<br />INSTALL NEW APRON TO MATCH ORIGINAL WHERE MISSING.
<br />REMOVE ALL CRACKED AND BROKEN GLASS AND INSTALL NEW .
<br />REPAIR CASING TO MATCH ORIGINAL.
<br />TYPE F
<br />FIXED
<br />DIVIDED LITES
<br />TYPE G
<br />ARCHED FRONT WINDOW
<br />DOOR PER
<br />SCHEDULE
<br />GLAZING
<br />1. PROVIDE SAFETY GLAZING / TEMPERED GLASS PER CBC 2406 AT
<br />THE FOLLOWING HAZARDOUS LOCATIONS:
<br />A. ALL GLAZING IN FIXED AND OPERABLE PANELS OF DOORS
<br />B. ALL GLAZING WITHIN 24" OF AN ADJACENT DOOR
<br />WINDOW TYPES
<br />Scale
<br />Project number
<br />Date
<br />Drawn by
<br />Jen Dunbar, AIA
<br />phone: 310.435.3928
<br />12314 La Maida Street
<br />Valley Village, CA 91607
<br />jen@dunbararchitecture.com
<br />DUNBAR
<br />ARCHITECTURE
<br />JD/AP
<br />3/8" = 1'-0"
<br />4/
<br />7
<br />/
<br />2
<br />0
<br />2
<br />5
<br />
<br />9
<br />:
<br />2
<br />2
<br />:
<br />3
<br />6
<br />
<br />P
<br />M
<br />A6.02
<br />WINDOW
<br />SCHEDULE
<br />23004
<br />CYPRESS CENTER
<br />RESTORATION
<br />CITY OF SANTA ANA
<br />1/17/2025
<br />625 S. CYPRESS AVE.
<br />SANTA ANA, CA 92701
<br />WINDOW SCHEDULE
<br />WI
<br />N
<br />D
<br />O
<br />W
<br />
<br />#
<br />LOCATION
<br />SCOPE / PHASE TY
<br />P
<br />E
<br />WINDOW MEASUREMENTS FRAME
<br />GL
<br />A
<br />Z
<br />I
<br />N
<br />G
<br />DETAIL
<br />REMARKSRO
<br />O
<br />M
<br />
<br />#
<br />NAME WI
<br />D
<br />T
<br />H
<br />HE
<br />I
<br />G
<br />H
<br />T
<br />SI
<br />L
<br />L
<br />
<br />H
<br />E
<br />I
<br />G
<br />H
<br />T
<br />MATERIAL FINISH HE
<br />A
<br />D
<br />JA
<br />M
<br />B
<br />SI
<br />L
<br />L
<br />1 (N) WINDOW / (E) OPENING G 8' - 8" 7' - 0" WD PT GL-1 CUSTOM FIXED GLAZING TO MATCH HISTORICAL DRAWINGS. REFER TO REMARK #: 1, 2,3,4
<br />2 01 ENTRY / CHECK IN OFFICE (N) WINDOW / (E) OPENING B 3' - 0" 5' - 1" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 1,2,3,4
<br />3 03 TRAINING ROOM B (E) WINDOW / RELOCATE & RESTORE B 3' - 0" 5' - 1" 4' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,5,6,7,8,9
<br />4 03 TRAINING ROOM B (E) WINDOW / RELOCATE & RESTORE B 3' - 0" 5' - 1" 4' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,5,6,7,8,9
<br />5 03 TRAINING ROOM B (N) WINDOW / (E) OPENING B 2' - 8" 5' - 1" 4' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 1,2,3,4
<br />6 03 TRAINING ROOM B (N) WINDOW / (E) OPENING B 2' - 8" 5' - 1" 4' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 1,2,3,4
<br />7 04 HALLWAY (E) WINDOW / RELOCATE & RESTORE E 1' - 6" 3' - 0" 4' - 1" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,5,6,7,8,9
<br />8 (E) WINDOW / RELOCATE & RESTORE B 2' - 0" 5' - 1" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,5,6,7,8,9
<br />9 (E) WINDOW / RELOCATE & RESTORE B 2' - 0" 5' - 1" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,5,6,7,8,9
<br />10 04 HALLWAY (E) WINDOW / RELOCATE & RESTORE E 1' - 6" 3' - 0" 4' - 1" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,5,6,7,8,9
<br />11 05 TRAINING ROOM C (E) WINDOW / RESTORE C 3' - 0" 4' - 6" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,6,7,8,9
<br />12 05 TRAINING ROOM C (N) WINDOW / (E) OPENING C 3' - 0"4' - 6" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 1,2,3,4
<br />13 05 TRAINING ROOM C (N) WINDOW / (E) OPENING C 3' - 0"4' - 6" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 1,2,3,4
<br />14 10 OFFICE AND BREAKROOM (E) WINDOW / RESTORE B 2' - 0" 4' - 6" 3' - 7" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 ORIGINAL WINDOW AND CASING INTACT. REFER TO REMARK #: 6, 9
<br />15 (N) WINDOW / (E) OPENING B 3' - 0" 5' - 1" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 ORIGINAL SILL, CASING, & APRON INTACT. REFER TO REMARK #: 1,3,4,7,9
<br />16 10 OFFICE AND BREAKROOM (N) WINDOW / (E) OPENING A 1' - 6" 3' - 0" 5' - 1" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 ORIGINAL WINDOW LOCATION PREVIOUSLY INFILLED.
<br />17 10 OFFICE AND BREAKROOM (E) WINDOW / RELOCATE & RESTORE B 2' - 6" 5' - 1" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #5, 6, 7,9,10
<br />18 11 RESTROOM NEW F 3' - 0" 2' - 6" 5' - 7" WD PT GL-2 3/A5.06 3/A5.06 2/A5.06 NEW WINDOW IN (E) OPENING
<br />19 09 MENS DEMO B 3' - 0" 5' - 1" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 SALVAGE PARTS IF POSSIBLE FOR REUSE ELSEWHERE. REFER TO REMARK #6.
<br />19.1 09 MENS NEW F 3' - 0" 2' - 6" 5' - 7" WD PT GL-2 3/A5.06 3/A5.06 2/A5.06 NEW WINDOW IN (E) OPENING
<br />20 07 WOMENS NEW F 3' - 0" 2' - 6" 5' - 7" WD PT GL-2 3/A5.06 3/A5.06 2/A5.06 NEW WINDOW IN (E) OPENING
<br />21 02 MULTI-PURPOSE ROOM A (E) WINDOW / RESTORE B 3' - 0" 5' - 1" 5' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK # 3,6,8,9
<br />22 02 MULTI-PURPOSE ROOM A (E) WINDOW / RESTORE B 3' - 0" 5' - 1" 5' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK # 3,6,8,9
<br />23 02 MULTI-PURPOSE ROOM A (E) WINDOW / RESTORE B 3' - 0" 5' - 1" 5' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK # 3,6,8,9
<br />24 02 MULTI-PURPOSE ROOM A (E) WINDOW / RESTORE B 3' - 0" 5' - 1" 5' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK # 3,6,8,9
<br />25 02 MULTI-PURPOSE ROOM A (E) WINDOW / RESTORE D 2' - 6" 6' - 4" 4' - 10" WD/ST PT GL-1 - - - STEEL DIVIDED LITE WINDOW IN WOOD FRAME. REFER TO REMARK # 8,9,10
<br />26 (N) WINDOW / (E) OPENING F 3' - 8" 3' - 0" 11' - 11 1/8" WD PT GL-2 RESTORE METAL DECORATIVE GRILLE. REFER TO REMARK #101ENTRY / CHECK IN OFFICE
<br />6' -1"
<br />6' -1"
<br />6' -1"
<br />01 ENTRY / CHECK IN OFFICE 2' - 10"
<br />No. Description Date
<br />BACKCHECK SET 1/17/2024
<br />BACKCHECK SET_V2 4/8/2025
|