Laserfiche WebLink
TYPE A <br />FIXED <br />REMARKS <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />TYPE B <br />DOUBLE HUNG <br />TYPE C <br />DOUBLE HUNG <br />WITH TRANSOM <br />TYPE D <br />FIXED ARCHED <br />NOTE: <br />WHERE ORIGINAL MATERIALS REMAIN AND ARE SALVAGEABLE, ORIGINAL <br />MATERIALS SHALL BE REPAIRED AS NEEDED. IF DETERIORATION IS BEYOND <br />REPAIR OR ORIGINAL BUILDING FEATURES ARE MISSING, ALL NEW <br />MATERIALS SHALL MATCH ORIGINALS AS CLOSE AS POSSIBLE AND MEET <br />THE SECRETARY OF THE INTERIOR'S STANDARDS FOR REHABILITATION. <br />ANY EXISTING DETAIL OR FEATURE INCLUDING PROFILES, WINDOW LUGS, <br />HARDWARE, ETC IS TO BE RESTORED AND REUSED IF INTACT OR <br />RECREATED TO MATCH ORIGINAL IF MISSING. <br />GLAZING AT WINDOWS TO BE TRUE DIVIDED LITES WHERE OCCURS. <br />LABEL, BUNDLE, & BAG ALL SALVAGED HARDWARE TO CORRESPOND TO <br />DOOR SCHEDULE. STRIP & CLEAN SALVAGED HARDWARE AS NEEDED FOR <br />REUSE. <br />REFER TO SHEET A6.01 EXISTING WINDOW INVENTORY FOR ADDITIONAL <br />REFERENCE. <br />ALL WINDOWS TO HAVE INTERIOR MOUNTED MANUAL ROLLER SHADES. <br />TYPE E <br />CASEMENT <br />WINDOW FRAME DAMAGED BEYOND REPAIR. REBUILD TO MATCH <br />ORIGINAL. <br />CASING DAMAGED BEYOND REPAIR. REBUILD TO MATCH ORIGINAL. <br />SALVAGE & REUSE (E) HARDWARE. MATCH ORIGINAL WHERE MISSING. <br />NEW WINDOW TO MATCH ORIGINAL IN (E) OPENING. <br />IF MATERIAL IS SALVAGEABLE. RELOCATE AS NOTED ON PLANS & <br />ELEVATIONS. NOTIFY ARCHITECT AND OWNER IF FRAMES OR CASING <br />CANNOT BE REUSED. <br />SALVAGE AND RESTORE INTACT ORIGINAL MATERIAL. NOTIFY ARCHITECT <br />IF SPECIFIC COMPONENTS CANNOT BE REUSED. <br />INSTALL NEW CROWN CASING TO MATCH ORIGINAL WHERE MISSING. <br />INSTALL NEW APRON TO MATCH ORIGINAL WHERE MISSING. <br />REMOVE ALL CRACKED AND BROKEN GLASS AND INSTALL NEW . <br />REPAIR CASING TO MATCH ORIGINAL. <br />TYPE F <br />FIXED <br />DIVIDED LITES <br />TYPE G <br />ARCHED FRONT WINDOW <br />DOOR PER <br />SCHEDULE <br />GLAZING <br />1. PROVIDE SAFETY GLAZING / TEMPERED GLASS PER CBC 2406 AT <br />THE FOLLOWING HAZARDOUS LOCATIONS: <br />A. ALL GLAZING IN FIXED AND OPERABLE PANELS OF DOORS <br />B. ALL GLAZING WITHIN 24" OF AN ADJACENT DOOR <br />WINDOW TYPES <br />Scale <br />Project number <br />Date <br />Drawn by <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />JD/AP <br />3/8" = 1'-0" <br />4/ <br />7 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />9 <br />: <br />2 <br />2 <br />: <br />3 <br />6 <br /> <br />P <br />M <br />A6.02 <br />WINDOW <br />SCHEDULE <br />23004 <br />CYPRESS CENTER <br />RESTORATION <br />CITY OF SANTA ANA <br />1/17/2025 <br />625 S. CYPRESS AVE. <br />SANTA ANA, CA 92701 <br />WINDOW SCHEDULE <br />WI <br />N <br />D <br />O <br />W <br /> <br /># <br />LOCATION <br />SCOPE / PHASE TY <br />P <br />E <br />WINDOW MEASUREMENTS FRAME <br />GL <br />A <br />Z <br />I <br />N <br />G <br />DETAIL <br />REMARKSRO <br />O <br />M <br /> <br /># <br />NAME WI <br />D <br />T <br />H <br />HE <br />I <br />G <br />H <br />T <br />SI <br />L <br />L <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />MATERIAL FINISH HE <br />A <br />D <br />JA <br />M <br />B <br />SI <br />L <br />L <br />1 (N) WINDOW / (E) OPENING G 8' - 8" 7' - 0" WD PT GL-1 CUSTOM FIXED GLAZING TO MATCH HISTORICAL DRAWINGS. REFER TO REMARK #: 1, 2,3,4 <br />2 01 ENTRY / CHECK IN OFFICE (N) WINDOW / (E) OPENING B 3' - 0" 5' - 1" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 1,2,3,4 <br />3 03 TRAINING ROOM B (E) WINDOW / RELOCATE & RESTORE B 3' - 0" 5' - 1" 4' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,5,6,7,8,9 <br />4 03 TRAINING ROOM B (E) WINDOW / RELOCATE & RESTORE B 3' - 0" 5' - 1" 4' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,5,6,7,8,9 <br />5 03 TRAINING ROOM B (N) WINDOW / (E) OPENING B 2' - 8" 5' - 1" 4' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 1,2,3,4 <br />6 03 TRAINING ROOM B (N) WINDOW / (E) OPENING B 2' - 8" 5' - 1" 4' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 1,2,3,4 <br />7 04 HALLWAY (E) WINDOW / RELOCATE & RESTORE E 1' - 6" 3' - 0" 4' - 1" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,5,6,7,8,9 <br />8 (E) WINDOW / RELOCATE & RESTORE B 2' - 0" 5' - 1" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,5,6,7,8,9 <br />9 (E) WINDOW / RELOCATE & RESTORE B 2' - 0" 5' - 1" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,5,6,7,8,9 <br />10 04 HALLWAY (E) WINDOW / RELOCATE & RESTORE E 1' - 6" 3' - 0" 4' - 1" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,5,6,7,8,9 <br />11 05 TRAINING ROOM C (E) WINDOW / RESTORE C 3' - 0" 4' - 6" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 3,6,7,8,9 <br />12 05 TRAINING ROOM C (N) WINDOW / (E) OPENING C 3' - 0"4' - 6" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 1,2,3,4 <br />13 05 TRAINING ROOM C (N) WINDOW / (E) OPENING C 3' - 0"4' - 6" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #: 1,2,3,4 <br />14 10 OFFICE AND BREAKROOM (E) WINDOW / RESTORE B 2' - 0" 4' - 6" 3' - 7" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 ORIGINAL WINDOW AND CASING INTACT. REFER TO REMARK #: 6, 9 <br />15 (N) WINDOW / (E) OPENING B 3' - 0" 5' - 1" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 ORIGINAL SILL, CASING, & APRON INTACT. REFER TO REMARK #: 1,3,4,7,9 <br />16 10 OFFICE AND BREAKROOM (N) WINDOW / (E) OPENING A 1' - 6" 3' - 0" 5' - 1" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 ORIGINAL WINDOW LOCATION PREVIOUSLY INFILLED. <br />17 10 OFFICE AND BREAKROOM (E) WINDOW / RELOCATE & RESTORE B 2' - 6" 5' - 1" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK #5, 6, 7,9,10 <br />18 11 RESTROOM NEW F 3' - 0" 2' - 6" 5' - 7" WD PT GL-2 3/A5.06 3/A5.06 2/A5.06 NEW WINDOW IN (E) OPENING <br />19 09 MENS DEMO B 3' - 0" 5' - 1" 3' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 SALVAGE PARTS IF POSSIBLE FOR REUSE ELSEWHERE. REFER TO REMARK #6. <br />19.1 09 MENS NEW F 3' - 0" 2' - 6" 5' - 7" WD PT GL-2 3/A5.06 3/A5.06 2/A5.06 NEW WINDOW IN (E) OPENING <br />20 07 WOMENS NEW F 3' - 0" 2' - 6" 5' - 7" WD PT GL-2 3/A5.06 3/A5.06 2/A5.06 NEW WINDOW IN (E) OPENING <br />21 02 MULTI-PURPOSE ROOM A (E) WINDOW / RESTORE B 3' - 0" 5' - 1" 5' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK # 3,6,8,9 <br />22 02 MULTI-PURPOSE ROOM A (E) WINDOW / RESTORE B 3' - 0" 5' - 1" 5' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK # 3,6,8,9 <br />23 02 MULTI-PURPOSE ROOM A (E) WINDOW / RESTORE B 3' - 0" 5' - 1" 5' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK # 3,6,8,9 <br />24 02 MULTI-PURPOSE ROOM A (E) WINDOW / RESTORE B 3' - 0" 5' - 1" 5' - 0" WD PT GL-1 3/A5.06 3/A5.06 2/A5.06 REFER TO REMARK # 3,6,8,9 <br />25 02 MULTI-PURPOSE ROOM A (E) WINDOW / RESTORE D 2' - 6" 6' - 4" 4' - 10" WD/ST PT GL-1 - - - STEEL DIVIDED LITE WINDOW IN WOOD FRAME. REFER TO REMARK # 8,9,10 <br />26 (N) WINDOW / (E) OPENING F 3' - 8" 3' - 0" 11' - 11 1/8" WD PT GL-2 RESTORE METAL DECORATIVE GRILLE. REFER TO REMARK #101ENTRY / CHECK IN OFFICE <br />6' -1" <br />6' -1" <br />6' -1" <br />01 ENTRY / CHECK IN OFFICE 2' - 10" <br />No. Description Date <br />BACKCHECK SET 1/17/2024 <br />BACKCHECK SET_V2 4/8/2025