Laserfiche WebLink
1 <br />2 <br />3 <br />A B C D E F <br />1033 SF <br />MULTI-PURPOSE <br />ROOM A <br />02 <br />212 SF <br />ENTRY / CHECK <br />IN OFFICE <br />01 348 SF <br />MULTI-PURPOSE <br />ROOM B <br />03 <br />HALLWAY <br />04 <br />375 SF <br />MULTI-PURPOSE <br />ROOM C <br />05 <br />HALLWAY <br />06 <br />WOMENS <br />07 <br />MENS <br />09 <br />343 SF <br />OFFICE AND <br />BREAKROOM <br />10 <br />RESTROOM <br />11 <br />JANITOR <br />12 <br />PA <br />MA <br />MSA <br />FC <br />1 <br />M2 <br />1 <br />M2 <br />FC <br />3 <br />1 <br />FC <br />5 <br />1 <br />M2 <br />M2 <br />FC <br />2 <br />1 <br />M2 <br />FC <br />4 <br />1 <br />MA-25 <br />F <br />2 MA-2,4 <br />25 <br />25 <br />25 <br />25 <br />25 <br />F4 3/4"C, 2#8 & 1#10GND <br />33 <br />3 <br />3 <br />3 <br />CU <br />1 <br />CU <br />2 <br />CU <br />3 <br />CU <br />4 <br />MA-1,3 <br />MA-5,7 <br />WP <br />F5WP <br />F4WP <br />F6WP <br />1"C, 2#6 & 1#8GND <br />MA-9,11 <br />3/4"C, 2#8 & 1#10GND <br />MA-13,15 <br />3/4"C, 2#8 & 1#10GND <br />EF <br />2 <br />#10EWH <br />1 <br />M <br />7 <br />8 <br />E1.11 <br /> 1/4" = 1'-0"E1.11 <br />1 POWER PLAN - PROPOSED <br />0'8'4'4' <br />Scale <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />No.Description Date <br />AS NOTED <br />Engineering Corp <br />Mechanical Electrical Plumbing <br />1920 MAIN STREET, SUITE 820 <br />IRVINE, CA 92614 <br />TEL: 949.516.6480 <br />EFORPDERETS <br />I <br />G <br />ER RE <br />EN <br />IGNE <br />LANOISS <br />CA L I FORNIASTATEOF <br />LEC T R ICAL <br />EXP: 3-31-27 <br />EFORPDERETS <br />I <br />G <br />ER RE <br />EN <br />IGNE <br />LANOISS <br />CA L I FORNIASTATEOF <br />No. E21819 <br />E <br /> <br />ALI S A FAIAN <br />90% CD 5/02/2024 <br />CYPRESS STREET <br />FIRE STATION <br />REHABILITATION <br />CITY OF SANTA ANA <br />625 S. CYPRESS <br />SANTA ANA, CA <br />Project number <br />Date <br />Drawn by TP/HH <br />23004 <br />1/15/2025 <br />PERMIT SET 5/17/2024 <br />BACK CHECK SET 1/15/2025 <br />BACK CHECK SET_V2 4/08/2025 <br />MECHANICAL <br />POWER PLAN <br />GENERAL NOTES: <br />1.THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC ONLY. DO NOT SCALE THE ELECTRICAL DRAWINGS TO DETERMINE <br />THE LOCATION OF THE EQUIPMENT OR OUTLETS. SEE ARCHITECTURAL PLANS, WHERE PROVIDED ON PROJECT FOR <br />EXTENT OF DEMOLITION. <br />2.ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET MINIMUM 24 INCHES. <br />3.ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM SPREAD OF FIRE WITH AN APPROVED <br />FIRESTOP SYSTEM EQUAL OR GREAT THAN THE FIRE RATING OF THE WALL. <br />4.ALL DEVICE HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO ROUGH-IN. <br />5.EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL CONFORM TO CEC, ARTICLE 300.22(C). <br />6.PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN CIRCUITRY. <br />7.PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT, EXCEPT WHERE OTHERWISE NOTED. HOME RUN CONDUCTORS <br />MAY BE COMBINED INTO ONE CONDUIT. NO RACEWAY OR CABLE SHALL CONTAIN MORE THAN NINE (9) CURRENT <br />CARRYING CONDUCTORS. WHERE MULTIPLE CONDUCTORS IN EXCESS OF THREE (3) ARE INDICATED ON THESE <br />DRAWINGS, THEY HAVE BEEN DERATED AS REQUIRED BY CEC ARTICLE 310 REQUIREMENTS. <br />8.NO EQUIPMENT, J-BOXES, ETC. REQUIRING ACCESS SHALL BE LOCATED IN HARD LID CEILING AREAS (UNLESS ACCESS <br />PANEL IS PROVIDED. COORDINATE WITH ARCHITECT.) RELOCATE ANY EXISTING EQUIPMENT, J-BOXES, ETC. TO <br />ACCESSIBLE CEILING AREA. <br />9.COORDINATE RECEPTACLE LOCATIONS WITH DATA OUTLET LOCATIONS AND GANG DEVICES IN BOXES AND COVER <br />PLATES. <br />10.POWER AND DATA CORE AND FACEPLATES TO MATCH COLOR OF ADJACENT WALL. <br />11.WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE CONTRACTOR SHALL PROVIDE THE FOLLOWING: <br />11.1.ALL BRANCH CIRCUITS SHALL BE IN EMT CONDUITS. <br />11.2.ALL BRANCH CIRCUITS SHALL BE ROUTED, NEATLY AND IN PARALLEL TO STRUCTURES OR DUCT WORK. <br />11.3.VISUALLY OBJECTIONABLE BRANCH CIRCUITS SHALL BE REROUTED AT THE REQUEST OF THE ARCHITECT AT NO <br />ADDITIONAL COST. <br />12. CONTRACTOR TO PROVIDE 1/2"CONDUIT WITH PULLSTRING TO ALL NEW THERMOSTAT LOCATIONS. COORDINATE <br />SCOPE OF WORK WITH MECHANICAL DRAWINGS. <br />KEYNOTES: <br />POWER TO FAN COIL UNIT FROM OUTSIDE, ROOF MOUNTED, CONDENSING UNIT. CONTRACTOR TO PROVIDE 3/4"C AND <br />CONNECTION TO ROOF MOUNTED CONDENSING UNIT. COORDINATE SCOPE OF WORK WITH SHEET E2.4-4. <br />CONTRACTOR TO PROVIDE 30AS/30AF, 250V, 1-PHASE & GROUND DISCONNECT SWITCH TO SERVE WATER HEATER. <br />CONTRACTOR TO PROVIDE 120V POWER CONNECTION AND GFCI RECEPTACLE TO SERVE FAN COIL UNIT CONDENSATE PUMP. <br />COORDINATE EXACT LOCATION OF NEW RECEPTACLE IN THE FIELD. <br />CONTRACTOR TO PROVIDE NEMA 3R, WEATHERPROOF, 60AS/40AF, 250V, 1-PHASE & GROUND FUSED DISCONNECT SWITCH TO <br />SERVE CONDENSING UNITS CU-1, CU-3. COORDINATE EXACT LOCATION OF DISCONNECT SWITCH IN THE FIELD. CIRCUITING <br />SHOW UNDER EQUIPMENT TAG FOR CLARITY OF DRAWINGS. <br />CONTRACTOR TO PROVIDE NEMA 3R, WEATHERPROOF, 60AS/50AF, 250V, 1-PHASE & GROUND FUSED DISCONNECT SWITCH TO <br />SERVE CONDENSING UNITS CU-2. COORDINATE EXACT LOCATION OF DISCONNECT SWITCH IN THE FIELD. CIRCUITING SHOW <br />UNDER EQUIPMENT TAG FOR CLARITY OF DRAWINGS. <br />CONTRACTOR TO PROVIDE NEMA 3R, WEATHERPROOF, 60AS/30AF, 250V, 1-PHASE & GROUND FUSED DISCONNECT SWITCH TO <br />SERVE CONDENSING UNITS CU-4. COORDINATE EXACT LOCATION OF DISCONNECT SWITCH IN THE FIELD. CIRCUITING SHOW <br />UNDER EQUIPMENT TAG FOR CLARITY OF DRAWINGS. <br />CONTRACTOR TO PROVIDE MOTOR RATED SWITCH AND CONNECT EXHAUST FAN TO WALL MOUNTED OCCUPANCY SENSOR. <br />COORDINATE EXACT REQUIREMENTS IN THE FIELD. <br />CONTRACTOR TO FURNISH AND INSTALL (4) FOUR ADDITIONAL GFCI RECEPTACLES, CONDUIT, WIRING ETC., IN THE ATTIC <br />SPACE. EXACT LOCATIONS TO BE DETERMINED IN THE FIELD WITH OWNER'S REPRESENTATIVE. CONTRACTOR SHALL ASSUME <br />A MIN. OF 200FT OF CONDUIT WORK. CONNECT TO PANEL PA-41. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8