Laserfiche WebLink
1 <br />2 <br />3 <br />A B C D E F <br />1033 SF <br />MULTI-PURPOSE <br />ROOM A <br />02 <br />212 SF <br />ENTRY / CHECK <br />IN OFFICE <br />01 348 SF <br />MULTI-PURPOSE <br />ROOM B <br />03 <br />HALLWAY <br />04 <br />375 SF <br />MULTI-PURPOSE <br />ROOM C <br />05 <br />HALLWAY <br />06 <br />WOMENS <br />07 <br />MENS <br />09 <br />343 SF <br />OFFICE AND <br />BREAKROOM <br />10 <br />RESTROOM <br />11 <br />JANITOR <br />12 <br />1 <br />1 <br />1 <br />3 <br />3 5 <br />5 <br />5 <br />PA WP <br />MA MSA <br />001 <br />002 <br />REFER TO SHEET E1.00 <br />FOR CONTINUATION <br />WP <br />5 <br />3 <br />J <br />PA-1&3&5 <br />J <br />PA-7&9&11 <br />7 7 <br />991111 <br />7 <br />7 <br />J <br />PA-13&15&17 <br />J <br />17 <br />17 <br />17 <br />15 15 15 <br />15 <br />131313 <br />13 <br />19 <br />19 <br />113 <br />D.F. <br />21 <br />21 <br />PA-19&21&23 <br />J <br />G.D <br />MW REF <br />25 <br />25 <br />25 <br />2727 <br />29 <br />PA-25&27&29 <br />PA-31&33&35 <br />35 <br />31 <br />31 <br />33 <br />PA-37&39 <br />37 39 <br />12 <br />12 <br />PA-2,4 <br />#10 <br />PA-6&8 <br />2 <br />4 <br />3 <br />WP <br />J <br />WP <br />PA-12&14 <br />1414 <br />5 <br />WP <br />10'-7" <br />J <br />5 <br />6 <br />7 <br />7 <br />7 <br />7 <br />CR <br />CR <br />PA-18 <br />PA-20 <br />8 <br />8 <br />8 <br />E1.10 <br /> 1/4" = 1'-0"E1.10 <br />1 POWER PLAN - PROPOSED <br />0'8'4'4' <br />Scale <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />No.Description Date <br />AS NOTED <br />Engineering Corp <br />Mechanical Electrical Plumbing <br />1920 MAIN STREET, SUITE 820 <br />IRVINE, CA 92614 <br />TEL: 949.516.6480 <br />EFORPDERETS <br />I <br />G <br />ER RE <br />EN <br />IGNE <br />LANOISS <br />CA L I FORNIASTATEOF <br />LEC T R ICAL <br />EXP: 3-31-27 <br />EFORPDERETS <br />I <br />G <br />ER RE <br />EN <br />IGNE <br />LANOISS <br />CA L I FORNIASTATEOF <br />No. E21819 <br />E <br /> <br />ALI S A FAIAN <br />90% CD 5/02/2024 <br />CYPRESS STREET <br />FIRE STATION <br />REHABILITATION <br />CITY OF SANTA ANA <br />625 S. CYPRESS <br />SANTA ANA, CA <br />Project number <br />Date <br />Drawn by TP/HH <br />23004 <br />1/15/2025 <br />PERMIT SET 5/17/2024 <br />BACK CHECK SET 1/15/2025 <br />BACK CHECK SET_V2 4/08/2025 <br />POWER PLAN <br />GENERAL NOTES: <br />1.THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC ONLY. DO NOT SCALE THE ELECTRICAL DRAWINGS TO <br />DETERMINE THE LOCATION OF THE EQUIPMENT OR OUTLETS. SEE ARCHITECTURAL PLANS, WHERE PROVIDED ON <br />PROJECT FOR EXTENT OF DEMOLITION. <br />2.ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET MINIMUM 24 INCHES. <br />3.ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM SPREAD OF FIRE WITH AN APPROVED <br />FIRESTOP SYSTEM EQUAL OR GREAT THAN THE FIRE RATING OF THE WALL. <br />4.ALL DEVICE HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO ROUGH-IN. <br />5.EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL CONFORM TO CEC, ARTICLE 300.22(C). <br />6.PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN CIRCUITRY <br />7.PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT, EXCEPT WHERE OTHERWISE NOTED. HOME RUN CONDUCTORS <br />MAY BE COMBINED INTO ONE CONDUIT. NO RACEWAY OR CABLE SHALL CONTAIN MORE THAN NINE (9) CURRENT <br />CARRYING CONDUCTORS. WHERE MULTIPLE CONDUCTORS IN EXCESS OF THREE (3) ARE INDICATED ON THESE <br />DRAWINGS, THEY HAVE BEEN DERATED AS REQUIRED BY CEC ARTICLE 310 REQUIREMENTS. <br />8.NO EQUIPMENT, J-BOXES, ETC. REQUIRING ACCESS SHALL BE LOCATED IN HARD LID CEILING AREAS (UNLESS ACCESS <br />PANEL IS PROVIDED. COORDINATE WITH ARCHITECT.) RELOCATE ANY EXISTING EQUIPMENT, J-BOXES, ETC. TO <br />ACCESSIBLE CEILING AREA. <br />9.COORDINATE RECEPTACLE LOCATIONS WITH DATA OUTLET LOCATIONS AND GANG DEVICES IN BOXES AND COVER <br />PLATES. <br />10.POWER AND DATA CORE AND FACEPLATES TO MATCH COLOR OF ADJACENT WALL. <br />11.WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE CONTRACTOR SHALL PROVIDE THE FOLLOWING: <br />11.1.ALL BRANCH CIRCUITS SHALL BE IN EMT CONDUITS. <br />11.2.ALL BRANCH CIRCUITS SHALL BE ROUTED, NEATLY AND IN PARALLEL TO STRUCTURES OR DUCT WORK. <br />11.3.VISUALLY OBJECTIONABLE BRANCH CIRCUITS SHALL BE REROUTED AT THE REQUEST OF THE ARCHITECT AT NO <br />ADDITIONAL COST. <br />12.CONTRACTOR SHALL SCAN FLOORS FOR REBAR AND AVOID WHERE NEW CORES ARE BEING MADE FOR NEW <br />POKE-THRU'S AND NEW DATA CONDUITS. COORDINATE EXACT LOCATIONS IN THE FIELD. <br />13.CONTRACTOR SHALL COORDINATE CONDUITS, BOX LOCATIONS, ETC. WITH THE CITY OF SANTA ANA'S TELE/DATA AND <br />SECURITY VENDOR PRIOR TO ROUGH-IN. <br />KEYNOTES: <br />CONTRACTOR TO PROVIDE POWER CONNECTION TO DRINKING FOUNTAIN. COORDINATE EXACT LOCATION OF POWER <br />CONNECTION IN THE FIELD PRIOR TO INSTALL. <br />PROVIDE POWER FOR UNDER COUNTER GARBAGE DISPOSAL WITH ON/OFF SWITCH AT +44" A.F.F. VERIFY ELECTRICAL <br />REQUIREMENTS. <br />RECEPTACLES DEDICATED TO IT SYSTEMS. COORDINATE EXACT LOCATION AND FINAL REQUIREMENTS IN THE FIELD. <br />PROVIDE GROUND BUS BAR FOR TELECOM EQUIPMENT. REFER TO SINGLE LINE DIAGRAM SHEET E0.10 FOR ADDITIONAL <br />REQUIREMENTS. <br />PROVIDE NEMA 3R, WEATHERPROOF, DISCONNECT SWITCH FOR IRRIGATION CONTROLLER. PROVIDE RECEPTACLE ADJACENT <br />TO IRRIGATION CONTROLLER. COORDINATE EXACT LOCATION AND REQUIREMENTS IN THE FIELD. <br />PROVIDE RECEPTACLE AND DATA OUTLET INSIDE CABINETRY. COORDINATE EXACT LOCATION IN THE FIELD. <br />PROVIDE EXTERIOR GFCI, WEATHERPROOF, TAMPER-RESISTANT RECEPTACLE WITH WHILE-IN-USE LOCKABLE COVER, EQUAL <br />TO TAYMAC CAT #: MX3200. CONTRACTOR SHALL PROVIDE LOCKS, FOR EACH EXTERIOR RECEPTACLE, KEYED EQUAL AND <br />HAND-OVER TO OWNER'S REPRESENTATIVE AT END OF PROJECT. <br />PROVIDE MOTOR RATED SWITCH AND DOOR OPENER. PROVIDE CONDUIT AND WIRES FOR CONTROLS & PUSH PLATES AND <br />COORDINATE EXACT REQUIREMENTS IN THE FIELD WITH AUTO-DOOR VENDER SUPPLIER. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8