32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG <br />A0.13 <br />DWELLING ADA <br />NOTES DETAILS <br />SCALE: N/A <br />1SEC. 1134A BATHING AND TOILET FACILITIES (OPTION 2)- <br />SECTION 1134A BATHING AND TOILET FACILITIES <br />1134A.L GENERAL. ALL BATHROOMS, BATHING AND TOILET FACILITIES WITHIN COVERED MULTIFAMILY DWELLING UNITS <br />SHALL COMPLY WITH THIS SECTION. <br />1134A.2 NUMBER OF COMPLYING BATHROOMS. BATHROOMS SHALL BE DESIGNED TO COMPLY WITH ONE OF THE <br />FOLLOWING OPTIONS: <br />OPTION 1 NOT USED <br />OPTION 2 ONLY ONE BATHROOM WITHIN THE DWELLING UNIT SHALL BE DESIGNED TO COMPLY WITH THE FOLLOWING: <br />1. TOILET, BATHING AND SHOWER FACILITIES SHALL COMPLY WITH SECTION 1134A.4. <br />2. BATHTUBS SHALL COMPLY WITH SECTION 1134A.5. <br />3. SHOWERS SHALL COMPLY WITH SECTION 1134A.6. <br />4. WATER CLOSETS SHALL COMPLY WITH SECTION 1134A.7. <br />5. LAVATORIES, VANITIES, MIRRORS AND TOWEL FIXTURES SHALL COMPLY WITH SECTION 1134A.8. <br />6. WHERE BOTH A TUB AND SHOWER ARE PROVIDED IN THE BATHROOM, AT LEAST ONE SHALL BE MADE <br />ACCESSIBLE. ADDITIONAL REQUIREMENTS APPLY TO DWELLING UNITS CONTAINING TWO OR MORE <br />BATHROOMS WHEN A BATHTUB IS PROVIDED AS THE ACCESSIBLE BATHING FIXTURE. WHERE TWO OR <br />MORE BATHROOMS ARE PROVIDED WITHIN THE SAME DWELLING UNIT AND A BATHTUB IS INSTALLED TO <br />COMPLY WITH OPTION 2, ITEM 6 IN ONE BATHROOM AND A SHOWER STALL IS PROVIDED IN A <br />SUBSEQUENT BATHROOM, BOTH THE BATHTUB SELECTED TO COMPLY WITH OPTION 2, ITEM 6 AND AT <br />LEAST ONE SHOWER STALL WITHIN THE DWELLING UNIT SHALL MEET ALL THE APPLICABLE <br />ACCESSIBILITY REQUIREMENTS PROVIDED IN SECTION 1134A. (SEE SECTION 1134A.5 FOR BATHTUBS,OR <br />SECTION 1134A.6 FOR SHOWERS.) <br />7. WHEN TWO OR MORE LAVATORIES ARE PROVIDED, AT LEAST ONE SHALL BE MADE ACCESSIBLE AND <br />COMPLY WITH SECTION 1134A.8. <br />8. BATHROOMS SHALL BE PROVIDED WITH AN ACCESSIBLE ROUTE INTO AND THROUGH THE BATHROOM. <br />9. IF A DOOR IS PROVIDED, IT SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 1132A.5. (see detail XX <br />this sheet) <br />10. A MINIMUM 18-INCH (457 MM) CLEAR MANEUVERING SPACE SHALL BE PROVIDED ON THE SWING SIDE OF <br />THE DOOR AT THE STRIKE EDGE OF THE DOOR. <br />11. SWITCHES, OUTLETS AND CONTROLS SHALL COMPLY WITH SECTION 1142A. (see detail XX/XXX) <br />12. REINFORCED WALLS TO ALLOW FOR THE FUTURE INSTALLATION OF GRAB BARS AROUND THE TOILET, <br />TUB AND SHOWER SHALL COMPLY WITH SECTIONS 1134A.5 FOR BATHTUBS, 1134A.6 FOR SHOWERS AND <br />1134A.7 FOR WATER CLOSETS. GRAB BARS SHALL COMPLY WITH SECTIONS 1127A.4 (see detail XX/XXX <br />AND 1127A.2.2, ITEM 4 (see detail XX/XXX). <br />WHEN OPTION 2 IS USED, ALL ADDITIONAL BATHROOMS MUST COMPLY WITH ITEMS 8 THROUGH 12 ABOVE. <br />1134A.3 POWDER ROOMS. ALL POWDER ROOMS SHALL BE DESIGNED TO COMPLY WITH SECTION 1134A.2, OPTION 2, <br />ITEMS 8 THROUGH 12. WHEN THE POWDER ROOM IS THE ONLY TOILET FACILITY LOCATED ON AN ACCESSIBLE <br />LEVEL, IT SHALL COMPLY WITH THE OPTION 2 ITEMS LISTED ABOVE, PLUS ALL ADDITIONAL REQUIREMENTS <br />LOCATED IN SECTIONS 1134A.4, 1134A.7 AND 1134A.8. <br />1134A.4 SUFFICIENT MANEUVERING SPACE. BATHING AND TOILET FACILITIES REQUIRED TO BE ADAPTABLE SHALL <br />PROVIDE SUFFICIENT MANEUVERING SPACE FOR A PERSON USING A WHEELCHAIR OR OTHER MOBILITY AID TO <br />ENTER AND CLOSE THE DOOR, USE THE FIXTURES, REOPEN THE DOOR AND EXIT. WHERE THE DOOR SWINGS <br />INTO THE BATHROOM OR POWDER ROOM, THERE SHALL BE A CLEAR MANEUVERING SPACE OUTSIDE THE <br />SWING OF THE DOOR OF AT LEAST 30 INCHES BY 48 INCHES (762 MM BY 1219 MM) WITHIN THE ROOM. THE CLEAR <br />MANEUVERING SPACE SHALL ALLOW THE USER TO POSITION A WHEELCHAIR OR OTHER MOBILITY AID CLEAR OF <br />THE PATH OF THE DOOR AS IT IS CLOSED AND TO PERMIT USE OF FIXTURES. DOORS MAY SWING INTO THE <br />REQUIRED CLEAR SPACE AT ANY FIXTURE WHEN A CLEAR MANEUVERING SPACE IS PROVIDED OUTSIDE THE <br />SWING ARC OF THE DOOR SO IT CAN BE CLOSED. MANEUVERING SPACES MAY INCLUDE ANY KNEE SPACE OR <br />TOE SPACE AVAILABLE BELOW BATHROOM FIXTURES. <br />1134A.5 BATHTUBS. BATHTUBS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH THIS SECTION. <br />1. FLOOR SPACE. THERE SHALL BE A MINIMUM CLEAR FLOOR SPACE 48 INCHES PARALLEL BY 30 INCHES <br />PERPENDICULAR (1219 MM BY 762 MM) TO THE SIDE OF A BATHTUB OR BATHTUB- SHOWER <br />COMBINATION (MEASURED FROM THE FOOT OR DRAIN END OF THE BATHTUB) TO PROVIDE FOR THE <br />MANEUVERING OF A WHEELCHAIR AND TRANSFER TO AND FROM THE BATHING FACILITIES. THE AREA <br />UNDER A LAVATORY MAY BE INCLUDED IN THE CLEAR FLOOR SPACE PROVIDED THE KNEE AND TOE <br />SPACE COMPLY WITH SECTION 1134A.8. CABINETS UNDER LAVATORIES AND TOILETS SHALL NOT <br />ENCROACH INTO THE CLEAR FLOOR SPACE. <br />2. REINFORCED WALLS FOR GRAB BARS. A BATHTUB INSTALLED WITHOUT SURROUNDING WALLS SHALL <br />PROVIDE REINFORCED AREAS FOR THE INSTALLATION OF FLOOR-MOUNTED GRAB BARS. WHERE A <br />BATHTUB IS INSTALLED WITH SURROUNDING WALLS, GRAB BAR REINFORCEMENT SHALL BE LOCATED <br />ON EACH END OF THE BATHTUB, 32 INCHES TO 38 INCHES (813 MM TO 965 MM) ABOVE THE FLOOR, <br />EXTENDING A MINIMUM OF 24 INCHES (610 MM) FROM THE FRONT EDGE OF THE BATHTUB TOWARD THE <br />BACK WALL OF THE BATHTUB. THE GRAB BAR REINFORCEMENT SHALL BE A MINIMUM OF 6 INCHES (152.4 <br />MM) NOMINAL IN HEIGHT; SEE FIGURE 11A-9G (b). <br />GRAB BAR REINFORCEMENT SHALL BE INSTALLED ON THE BACK WALL OF THE BATHTUB A MAXIMUM OF <br />6 INCHES (152.4 MM) ABOVE THE BATHTUB RIM EXTENDING UPWARD TO AT LEAST 38 INCHES (965 MM) <br />ABOVE THE FLOOR. GRAB BAR BACKING SHALL BE INSTALLED HORIZONTALLY TO PERMIT THE <br />INSTALLATION OF A 48-INCH (1219 MM) GRAB BAR WITH EACH END A MAXIMUM OF 6 INCHES (152.4 MM) <br />FROM THE END WALLS OF THE BATHTUB. THE GRAB BAR REINFORCEMENT SHALL BE A MINIMUM OF 6 <br />INCHES (152.4 MM) NOMINAL IN HEIGHT. <br />3. BATHTUB CONTROLS. FAUCET CONTROLS AND OPERATION MECHANISMS SHALL BE OPERABLE WITH <br />ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE <br />FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUND-FORCE (22.2 N). <br />LEVER OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF <br />ACCEPTABLE DESIGNS. <br />4. SHOWER UNIT. A SHOWER SPRAY UNIT IS NOT REQUIRED IN BATHTUBS. <br />5. BATHTUB ENCLOSURES. DOORS AND PANELS OF BATHTUB ENCLOSURES SHALL BE SUBSTANTIALLY <br />CONSTRUCTED FROM APPROVED, SHATTER-RESISTANT MATERIALS. HINGED DOORS SHALL OPEN <br />OUTWARD. GLAZING USED IN DOORS AND PANELS OF BATHTUB ENCLOSURES SHALL BE FULLY <br />TEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC. WHEN GLASS IS USED, IT SHALL HAVE <br />MINIMUM THICKNESS OF NOT LESS THAN 1/8 INCH (3.17 MM) WHEN FULLY TEMPERED, OR 1/4 INCH (6.35 <br />MM) WHEN LAMINATED, AND SHALL PASS THE TEST REQUIREMENTS OF THIS PART, CHAPTER 24, GLASS <br />AND GLAZING. PLASTICS USED IN DOORS AND PANELS OF BATHTUB ENCLOSURES SHALL BE OF A <br />SHATTER-RESISTANT TYPE. <br />1134A.6 SHOWERS. SHOWERS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH THIS SECTION. <br />1. SIZE. WHEN ONE OR MORE SHOWER STALLS ARE PROVIDED WITHIN THE SAME DWELLING UNIT, AT <br />LEAST ONE SHOWER STALL COMPLY WITH ONE OF THE FOLLOWING REQUIREMENTS AS ILLUSTRATED IN <br />FIGURE 11A-9L. <br />1.1 THE SHOWER STALL SHALL MEASURE AT LEAST 42 INCHES WIDE BY 48 INCHES DEEP (1067 MM BY <br />1219 MM) WITH AN ENTRANCE OPENING OF AT LEAST 36 INCHES (914 MM); OR <br />1.2. THE SHOWER STALL SHALL MEASURE AT LEAST 30 INCHES DEEP BY 60 INCHES WIDE (762 MM BY 1524 <br />MM) WITH AN ENTRANCE OPENING OF AT LEAST 60 INCHES (1524 MM). A WATER CLOSET MAY PROJECT <br />A MAXIMUM OF 12 INCHES (305 MM) INTO THE OPENING, PROVIDED THAT A MINIMUM OF 36 INCHES (914 <br />MM) CLEAR SPACE IS MAINTAINED BETWEEN THE WATER CLOSET AND THE SHOWER WALL; OR <br />1.3. OTHER SHOWER STALL CONFIGURATIONS SHALL MEASURE AT LEAST 36 INCHES DEEP BY 60 INCHES WIDE <br />(914 MM BY 1524 MM) WITH AN ENTRANCE OPENING OF AT LEAST 36 INCHES (914 MM) WHEN A WALL IS <br />INSTALLED ON THE OPENING SIDE.2. SLOPE. THE MAXIMUM SLOPE OF THE SHOWER FLOOR SHALL BE 1/2 <br />INCH (12.7 MM) PER FOOT IN ANY DIRECTION AND SHALL SLOPE TO A DRAIN. THE FLOOR SURFACES SHALL <br />BE OF GRIT- FACED OR CARBORUNDUM TILE OR OF MATERIAL PROVIDING EQUIVALENT SLIP RESISTANCE. <br />3. FLOOR SPACE. A CLEAR MANEUVERING SPACE AT LEAST 30 INCHES IN WIDTH BY 48 INCHES IN LENGTH (762 <br />MM BY 1219 MM) SHALL BE LOCATED OUTSIDE THE SHOWER, FLUSH AND PARALLEL TO THE CONTROL WALL. <br />4. REINFORCED WALLS FOR GRAB BARS. GRAB BAR REINFORCEMENT SHALL BE INSTALLED CONTINUOUS IN <br />THE WALLS OF SHOWERS 32 INCHES TO 38 INCHES (813 MM TO 965 MM) ABOVE THE FLOOR; SEE FIGURE <br />11A-9G (c). THE GRAB BAR REINFORCEMENT SHALL BE A MINIMUM OF 6 INCHES (152.4 MM) NOMINAL IN <br />HEIGHT. GLASS-WALLED SHOWER STALLS SHALL PROVIDE REINFORCEMENT FOR INSTALLATION OF <br />FLOOR-MOUNTED OR CEILING-MOUNTED GRAB BARS. <br />5. THRESHOLDS. WHEN A THRESHOLD IS USED, IT SHALL BE A MAXIMUM OF 2 INCHES (50.8 MM) IN HEIGHT AND <br />HAVE A BEVELED OR SLOPED ANGLE NOT EXCEEDING 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL (26.6 <br />DEGREES FROM THE HORIZONTAL). THRESHOLDS 1/2 INCH (12.7 MM) OR LESS IN HEIGHT MAY HAVE A <br />BEVELED OR SLOPED ANGLE NOT EXCEEDING 1 UNIT VERTICAL IN 1 UNIT HORIZONTAL (45 DEGREES FROM <br />THE HORIZONTAL). <br />6. SHOWER CONTROLS. FAUCET CONTROLS AND OPERATION MECHANISMS SHALL BE OPERABLE WITH ONE <br />HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE <br />REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS (22.2N). LEVER OPERATED, <br />PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. <br />7. SHOWER ENCLOSURES. DOORS AND PANELS OF SHOWER ENCLOSURES SHALL BE SUBSTANTIALLY <br />CONSTRUCTED FROM APPROVED, SHATTER-RESISTANT MATERIALS. HINGED SHOWER DOORS SHALL OPEN <br />OUTWARD. GLAZING USED IN DOORS AND PANELS OF SHOWER ENCLOSURES SHALL BE FULLY TEMPERED, <br />LAMINATED SAFETY GLASS OR APPROVED PLASTIC. WHEN GLASS IS USED, IT SHALL HAVE MINIMUM <br />THICKNESS OF NOT LESS THAN 1/8 INCH (3.17 MM) WHEN FULLY TEMPERED, OR 1/4 INCH (6.35 MM) WHEN <br />LAMINATED, AND SHALL PASS THE TEST REQUIREMENTS OF THIS PART, CHAPTER 24, GLASS AND GLAZING. <br />PLASTICS USED IN DOORS AND PANELS OF SHOWER ENCLOSURES SHALL BE OF A SHATTER-RESISTANT <br />TYPE. <br />1134A.7 WATER CLOSETS. WATER CLOSETS IN BATHROOMS OR POWDER ROOMS REQUIRED TO BE ACCESSIBLE SHALL <br />COMPLY WITH THIS SECTION <br />1. FLOOR SPACE AND LOCATION. THE MINIMUM FLOOR SPACE PROVIDED AT A WATER CLOSET SHALL BE 48 <br />INCHES ( 1219 MM) IN CLEAR WIDTH. THE CLEAR FLOOR SPACE SHALL EXTEND PAST THE FRONT EDGE OF <br />THE WATER CLOSET AT LEAST 36 INCHES (914 MM). SEE FIGURE 11A-9M. <br />EXCEPTION: THE 48-INCH (1219 MM) MINIMUM CLEAR WIDTH MAY BE REDUCED TO 36 INCHES (914 MM) <br />FOR LAVATORIES, CABINETS, WING WALLS OR PRIVACY WALLS LOCATED IMMEDIATELY ADJACENT TO A <br />WATER CLOSET WHICH EXTEND NO MORE THAN 24 INCHES (610 MM) IN DEPTH. <br />WATER CLOSETS SHALL BE LOCATED WITHIN BATHROOMS IN A MANNER THAT PERMITS A GRAB BAR TO BE <br />INSTALLED ON ONE SIDE OF THE FIXTURE. THE CENTERLINE OF THE WATER CLOSET SHALL BE 17 INCHES (432 <br />MM) MINIMUM TO 18 INCHES (457 MM) MAXIMUM FROM A GRAB BAR WALL OR PARTITION. IN LOCATIONS WHERE <br />WATER CLOSETS ARE ADJACENT TO NON-GRAB BAR WALLS, VANITIES, LAVATORIES OR BATHTUBS, THE <br />CENTERLINE OF THE FIXTURE SHALL BE A MINIMUM OF 18 INCHES (457 MM)FROM THE OBSTACLE. <br />2. REINFORCED WALLS FOR GRAB BARS. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE <br />WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR <br />INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATIVE GRAB BARS. WHERE THE WATER <br />CLOSET IS PLACED ADJACENT TO A SIDE WALL, REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDES OR <br />ONE SIDE AND THE BACK. IF REINFORCEMENT IS INSTALLED AT THE BACK, IT SHALL BE INSTALLED BETWEEN <br />32 INCHES (813 MM) AND 38 INCHES (965 MM) ABOVE THE FLOOR. THE GRAB BAR REINFORCEMENT SHALL BE <br />A MINIMUM OF 6 INCHES ( 152.4 MM) NOMINAL IN HEIGHT. THE BACKING SHALL BE A MINIMUM OF 40 INCHES <br />(1016 MM) IN LENGTH. REINFORCEMENT INSTALLED AT THE SIDE OF THE WATER CLOSET SHALL BE <br />INSTALLED 32 INCHES TO 38 INCHES (813 MM TO 965 MM) ABOVE THE FLOOR. THE REINFORCEMENT SHALL <br />BE INSTALLED A MAXIMUM OF 12 INCHES (305 MM) FROM THE REAR WALL AND SHALL EXTEND A MINIMUM OF <br />26 INCHES (660 MM) IN FRONT OF THE WATER CLOSET. THE GRAB BAR REINFORCEMENT SHALL BE A <br />MINIMUM OF 6 INCHES (152.4 MM) NOMINAL IN HEIGHT; SEE FIGURE 11A-9G (a). <br />3. SEAT HEIGHT. THE MINIMUM HEIGHT OF WATER CLOSET SEATS SHALL BE 15 INCHES (381 MM) ABOVE THE <br />FLOOR. <br />4. WATER CLOSET CONTROLS. WATER CLOSET CONTROLS SHALL BE MOUNTED NO MORE THAN 44 INCHES <br />(1118 MM) ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN <br />5 POUNDS (22.2 N). <br />1134A.8 LAVATORIES, VANITIES, MIRRORS AND TOWEL FIXTURES. BATHROOMS OR POWDER ROOMS REQUIRED TO BE <br />ACCESSIBLE SHALL HAVE AT LEAST ONE ACCESSIBLE LAVATORY. WHERE MIRRORS AND TOWEL FIXTURES ARE <br />PROVIDED, AT LEAST ONE OF EACH SHALL BE ACCESSIBLE. <br />1. LOCATION. VANITIES AND LAVATORIES SHALL BE INSTALLED WITH THE CENTERLINE OF THE FIXTURE A <br />MINIMUM OF 18 INCHES (457 MM) HORIZONTALLY FROM AN ADJOINING WALL OR FIXTURE TO ALLOW FOR <br />FORWARD APPROACH. WHEN PARALLEL APPROACH IS PROVIDED, LAVATORIES SHALL BE INSTALLED WITH <br />THE CENTERLINE OF THE FIXTURE A MINIMUM OF 24 INCHES (610 MM) HORIZONTALLY FROM AN ADJOINING <br />WALL OR FIXTURE; see figure 34.1. <br /> THE TOP OF THE FIXTURE RIM SHALL BE A MAXIMUM OF 34 INCHES (864 MM) ABOVE THE FINISHED FLOOR. <br />2.. FLOOR SPACE. A CLEAR MANEUVERING SPACE AT LEAST 30 INCHES BY 48 INCHES (762 MM BY 1219 MM) <br />SHALL BE PROVIDED AT LAVATORIES AND SHALL BE CENTERED ON THE LAVATORY. <br />3. CABINETS. CABINETS UNDER LAVATORIES ARE ACCEPTABLE PROVIDED THE BATHROOM HAS SPACE TO <br />ALLOW A PARALLEL APPROACH BY A PERSON IN A WHEELCHAIR AND THE LAVATORY CABINETS ARE <br />DESIGNED WITH ADAPTABLE KNEE AND TOE SPACE; see figure 34.2. <br />4. KNEE AND TOE SPACE. KNEE AND TOE SPACE SHALL BE PROVIDED AS FOLLOWS: <br />4.1. THE KNEE SPACE SHALL BE AT LEAST 30 INCHES (762 MM) WIDE AND 8 INCHES (203.2 MM) DEEP. <br />4.2.THE KNEE SPACE SHALL BE AT LEAST 29 INCHES (737 MM) HIGH AT THE FRONT FACE AND REDUCING <br />TO NOT LESS THAN 27 INCHES (686 MM) AT A POINT 8 INCHES (203.2 MM) BACK FROM THE FRONT EDGE. <br />4.3. THE KNEE AND TOE SPACE REQUIRED IN THIS SECTION SHALL BE PROVIDED BY ONE OF THE <br />FOLLOWING: <br />4.3.1.THE SPACE BENEATH THE LAVATORY SHALL BE LEFT CLEAR AND UNOBSTRUCTED; <br />4.3.2.ANY CABINET BENEATH THE LAVATORY SHALL BE REMOVABLE WITHOUT THE USE OF <br />SPECIALIZED KNOWLEDGE OR SPECIALIZED TOOLS; OR <br />4.3.3.DOORS TO THE CABINET BENEATH THE LAVATORY SHALL BE REMOVABLE OR OPENABLE TO <br />PROVIDE THE REQUIRED UNOBSTRUCTED KNEE AND TOE SPACE. <br />4.4 THE TOE SPACE REQUIRED IN THIS SECTION SHALL BE PROVIDED AS FOLLOWS: <br />4.4.1.SHALL BE AT LEAST 30 INCHES (762 MM) WIDE AND CENTERED ON THE LAVATORY. <br />4.4.2.SHALL BE AT LEAST 17 INCHES (432 MM) DEEP, MEASURED FROM THE FRONT EDGE. <br />4.4.3.SHALL BE AT LEAST 9 INCHES (228.6 MM) HIGH FROM THE FLOOR. <br />5. FINISHED FLOOR. THE FINISHED FLOOR BENEATH THE LAVATORY SHALL BE EXTENDED TO THE WALL. <br />6.PLUMBING PROTECTION. HOT WATER AND DRAIN PIPES EXPOSED UNDER LAVATORIES SHALL BE <br />INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER <br />LAVATORIES. <br />7. LAVATORY FAUCET CONTROLS. FAUCET CONTROLS AND OPERATION MECHANISMS SHALL BE <br />OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING PINCHING OR TWISTING OF THE <br />WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS (22.2 N). <br />LEVER OPERATED PUSH-TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF <br />ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT <br />LEAST 10 SECONDS. <br />8. MIRRORS AND TOWEL FIXTURES. WHERE MIRRORS OR TOWEL FIXTURES ARE PROVIDED THEY SHALL BE <br />MOUNTED WITH THE BOTTOM REFLECTIVE EDGE NO HIGHER THAN 40 INCHES (1016 MM) FROM THE <br />FLOOR. <br />FIGURE 11A-9G <br />REINFORCEMENT FOR GRAB BARS <br />(areas outlined in dashed lines and shaded represent location for future installation of grab bars) <br />(b) <br />grab bar reinforcement for adaptable bathtubs <br />4'-0" MIN6" <br />MAX <br />6" <br />MAX <br />control end (foot) wall back wall head end wall <br />2' <br />- <br />8 <br />" <br /> <br />M <br />A <br />X <br />2'-0" <br />MIN <br />2'-0" <br />MIN <br />6" <br />MA <br />X <br />3' <br />- <br />2 <br />" <br /> <br />M <br />I <br />N <br />provide additional backing for <br />fold away grab bar when <br />required by 1134A.7 item 2; <br />verify requirement with <br />selected manufacturer <br />2' <br />- <br />3 <br />" <br />6' <br />- <br />4 <br />" <br />℄ <br />(a) <br />grab bar reinforcement for adaptable water closets <br />back wall side wall <br />2' <br />- <br />8 <br />" <br /> <br />M <br />A <br />X <br />2' <br />- <br />8 <br />" <br /> <br />M <br />A <br />X <br />3' <br />- <br />2 <br />" <br /> <br />M <br />I <br />N <br />3'-6" MIN1'-0" <br />MAX <br />3' <br />- <br />2 <br />" <br /> <br />M <br />I <br />N <br />2'-2" <br />MIN <br />3'-4" MIN <br />1' <br />- <br />4 <br />" <br />MI <br />N <br />1'-4" <br />(c) <br />grab bar reinforcement for adaptable showers <br />control end side wall back wall side wall <br />2' <br />- <br />8 <br />" <br /> <br />M <br />A <br />X <br />6" <br />MI <br />N <br />3' <br />- <br />2 <br />" <br /> <br />M <br />I <br />N <br />FIGURE 11A-9L <br />SHOWER SIZES <br />3' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />1'-0" <br />MAX <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />5'-0" MIN <br />FIGURE 11A-9M <br />WING WALL OR CABINET AT WATER CLOSET <br />(clear floor space at toilets shown shaded) <br />1'-6" <br />MIN <br />4'-0" MIN <br />16" min <br />18" max <br />3'-0" MIN <br />2' <br />- <br />0 <br />" <br />MA <br />X <br />3' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />℄ <br />6" max bowl depth, top of rim 34" max <br />clearance required between base cabinet and <br />℄ of water closet; also see Figure 11A-9M <br />3'-6" min width base cabinet designed to <br />provide the adaptable knee, toe and 30"x48" <br />clear floor space clearances required for <br />forward approach to sink; see interior cabinet <br />elevation for additional requirements <br />2'-0" MIN <br />CLEAR <br />2'-6" MIN <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />℄ <br />1' <br />- <br />5 <br />" <br />MI <br />N <br />1'-3" <br />1' <br />- <br />1 <br />1 <br />" <br />MA <br />X <br />4'-0" MIN <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />clear floor space required for parallel <br />approach to base cabinet <br />Clearance required from finish wall surface <br />to ℄ of sink to allow for required parallel <br />approach when base cabinet is provided. <br />1'-11" MAX <br />9" <br />MI <br />N <br />2' <br />- <br />1 <br />0 <br />" <br /> <br />M <br />A <br />X <br />2' <br />- <br />3 <br />" <br /> <br />M <br />I <br />N <br />at <br /> <br />b <br />a <br />c <br />k <br /> <br />o <br />f <br /> <br />k <br />n <br />e <br />e <br />11" MIN <br /> sink rim or <br />counter top <br />apron <br />toe <br />8" <br />MIN <br />1'-5" MIN <br />faucet controls per 1134A.8 # 7 <br />knee and toe space <br />per 1134A.8 # 4 <br />(shown shaded) <br />plumbing protection <br />per 1134A.8 # 6 <br />2' <br />- <br />5 <br />" <br /> <br />M <br />I <br />N <br />at <br /> <br />f <br />r <br />o <br />n <br />t <br /> <br />a <br />p <br />r <br />o <br />n <br />knee <br />mirrors per 1134A.8 # 8 <br />mirrors and <br />towel fixtures <br />3' <br />- <br />4 <br />" <br /> <br />M <br />A <br />X <br />towel fixtures <br />per 1134A.8 # 8 <br />floor finish <br />per 1134A.8 # 5 <br />1'-6" <br />MIN <br />FIGURE 34.1 <br />CABINETS UNDER LAVATORIES <br />FIGURE 34.2 <br />CABINET ADAPTABLE WITH KNEE AND TOE SPACE <br />℄ <br />6' <br />- <br />4 <br />" <br />3' <br />- <br />8 <br />" <br /> <br />M <br />A <br />X <br />2'-0" <br />MAX <br />℄2'-0" <br />MAX <br />full width at all <br />shower stall walls <br />co <br />n <br />t <br />r <br />o <br />l <br /> <br />e <br />n <br />d <br />si <br />d <br />e <br /> <br />w <br />a <br />l <br />l <br />back wall <br />si <br />d <br />e <br /> <br />w <br />a <br />l <br />l <br />(1.2) <br />30"x60" shower stall <br />(with water closet projection shown) <br />3' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />(1.3) <br />36"x60" shower stall with 36" <br />entrance opening <br />(1.1) <br />42"x48" shower stall with 36" <br />entrance opening <br />3'-0" MIN <br />3'-3" min with <br />shower door <br />3' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />3' <br />- <br />3 <br />" <br /> <br />m <br />i <br />n <br /> <br />w <br />i <br />t <br />h <br />sh <br />o <br />w <br />e <br />r <br /> <br />d <br />o <br />o <br />r <br />5'-0" MIN <br />co <br />n <br />t <br />r <br />o <br />l <br /> <br />e <br />n <br />d <br />si <br />d <br />e <br /> <br />w <br />a <br />l <br />l <br />back wall <br />si <br />d <br />e <br /> <br />w <br />a <br />l <br />l <br />4'-0" MIN <br />control side wall <br />side wall <br />(seat side FHA) <br />ba <br />c <br />k <br /> <br />w <br />a <br />l <br />l <br />reinforce full width of shower for <br />future wall mounted seat starting at <br />the floor to a height of 2'-0" (FHA) <br />6" <br />4' <br />- <br />6 <br />" <br /> <br />( <br />F <br />H <br />A <br /> <br />s <br />e <br />a <br />t <br />) <br />additional clear space required to allow <br />for side transfer to future seat (FHA) <br />shower door shall provide 34" <br />clear opening with when door is <br />open at 90° <br />34 <br />" <br /> <br />c <br />l <br />r <br /> <br />o <br />p <br />n <br />g <br />1'-6" <br />MIN <br />16" min <br />18" max <br />3'-0" MIN <br />℄ <br />2'-0" MIN <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />TU <br />B <br /> <br />A <br />C <br />C <br />E <br />S <br />S <br />1'-0" <br />MAX <br />1'-0" <br />MAX <br />4'-0" MIN <br /> fold away grab bar required <br />at water closet adjacent to tub; <br />see Figure 11A-9G (a) <br />2' <br />- <br />0 <br />" <br />MA <br />X <br /> 3'-4" reinforced wall for <br />required grab bar reinforcing <br />over rides 3'-0" min shown; <br />see Figure 11A-9G (a) <br />3' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />3' <br />- <br />3 <br />" <br /> <br />m <br />i <br />n <br /> <br />w <br />i <br />t <br />h <br />sh <br />o <br />w <br />e <br />r <br /> <br />d <br />o <br />o <br />r <br />BATHROOMS AND TOILET <br />FACILITIES SHALL BE DESIGNED TO <br />COMPLY PER SECTION 11341.2 <br />WITH "OPTION 2". <br />BATHROOM REQ (OPTION 2)-