Laserfiche WebLink
32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG <br />SEC. 1127A.11 STORAGE - <br />1127A.11 STORAGE <br />1127A.11.1 GENERAL. IF FIXED STORAGE FACILITIES SUCH AS CABINETS, SHELVES, CLOSETS OR DRAWERS ARE PROVIDED WHERE ACCESS IS REQUIRED BY CBC SECTIONS 1.8.2.1.2 AND 1102A (see detail XX / XXX), AT LEAST ONE OF EACH TYPE OF <br />FACILITY PROVIDED SHALL COMPLY WITH THIS SECTION. ADDITIONAL STORAGE MAY BE PROVIDED OUTSIDE OF THE REACH RANGES SPECIFIED IN SECTION 1138A.3 (see detail XX / XXX). <br />1127A.11.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES (762 MM BY 1219 MM) COMPLYING WITH SECTION 1138A.1.4 (see detail XX / XXX) THAT ALLOWS EITHER A FORWARD OR PARALLEL APPROACH BY A PERSON <br />USING A WHEELCHAIR SHALL BE PROVIDED AT ACCESSIBLE STORAGE FACILITIES. <br />1127A.11.3 HEIGHT. ACCESSIBLE STORAGE SPACES AND CLOTHES RODS SHALL BE WITHIN AT LEAST ONE OF THE REACH RANGES SPECIFIED IN SECTION 1138A.3 (see detail XX / XXX). (SEE FIGURE 11A-1I AND FIGURE 11A-1J.) <br />1127A.11.4 HARDWARE. HARDWARE FOR ACCESSIBLE STORAGE FACILITIES SHALL COMPLY WITH SECTION 1138A.4 (see detail XX / XXX). TOUCH LATCHES AND U-SHAPED PULLS ARE ACCEPTABLE. <br />FIGURE 11A-1I <br />FORWARD REACH <br />(b) <br />forward reach over obstruction <br />(a) <br />unobstructed forward reach <br />planelevation <br />4'-0" MIN <br /> <br />1' <br />- <br />3 <br />" <br />MI <br />N <br /> <br />4' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />clear floor space <br />planelevation <br />4'-0" MIN <br /> <br />2' <br />- <br />1 <br />0 <br />" <br /> <br />M <br />A <br />X <br />20" <br />MAX <br />required knee <br />and toe space <br /> <br />4' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />clear floor space <br />4'-0" MIN <br /> <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br /> <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />20" <br />MAX <br />4'-0" MIN <br />X ≥ 20"X ≥ 20" <br />planelevation <br />4'-0" MIN <br /> <br />2' <br />- <br />1 <br />0 <br />" <br /> <br />M <br />A <br />X <br />20"< Y ≤ 25" <br />required knee <br />and toe space <br /> <br />4' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />clear floor space <br /> <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />20"< Y ≤ 25" <br />4'-0" MIN <br />X ≥ YX ≥ Y <br />FIGURE 11A-1I <br />SIDE REACH <br />(a) <br />unobstructed side reach <br />high and low <br />side reach limits <br /> <br />1' <br />- <br />3 <br />" <br />MI <br />N <br /> <br />4' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />clear floor space <br />2'-6" MIN <br />clear floor space for <br />parallel approach <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br /> 2'-6" MIN <br /> <br />1 <br />' <br />- <br />3 <br />" <br />MI <br />N <br /> <br />4' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />clear floor space <br />2'-6" MIN <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br /> 2'-6" MIN <br />high and low <br />side reach limits <br />clear floor space for <br />parallel approach <br />10" <br />MAX <br />10" <br />MAX <br /> <br />2 <br />' <br />- <br />1 <br />0 <br />" <br />MA <br />X <br /> <br />3' <br />- <br />1 <br />0 <br />" <br /> <br />M <br />A <br />X <br />clear floor space <br />2'-6" MIN <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br /> 2'-6" MIN <br />maximum side reach <br />over obstruction <br />clear floor space for <br />parallel approach <br />10" MIN <br />2'-0" MAX <br />10" MIN <br />2'-0" MAX <br />(b) <br />side reach over obstruction 10" <br />maximum <br />(c) <br />side reach over obstruction <br />10" minimum and 24" maximum <br />SEC. 1127A.12 SEATING, TABLES AND COUNTERS - <br />1127A.12 FIXED OR BUILT-IN SEATING, TABLES AND COUNTERS <br />1127A.12.1 MINIMUM SEATING. WHERE FIXED OR BUILT-IN SEATING, TABLES OR COUNTERS ARE PROVIDED FOR <br />RESIDENTS OR GUESTS, 5 PERCENT, BUT NOT LESS THAN ONE, SHALL BE ACCESSIBLE AS PROVIDED IN THIS <br />SECTION. <br />1127A.12.2 CLEAR FLOOR SPACE. WHEN SEATING SPACES FOR PERSONS IN WHEELCHAIRS ARE PROVIDED AT FIXED <br />TABLES OR COUNTERS, CLEAR FLOOR SPACE COMPLYING WITH SECTION 1138A.1.4(see detail XX / XXX) <br />POSITIONED FOR A FORWARD APPROACH SHALL BE PROVIDED. SUCH CLEAR FLOOR SPACE SHALL NOT <br />OVERLAP THE REQUIRED KNEE AND TOE SPACE BY MORE THAN 19 INCHES ( 483 MM). (SEE FIGURE 11A-1K.) <br />1127A.12.3 KNEE AND TOE SPACE. WHEN SEATING FOR PERSONS IN WHEELCHAIRS IS PROVIDED AT FIXED TABLES OR <br />COUNTERS, KNEE AND TOE SPACE COMPLYING WITH SECTION 1138A.2 (see detail XX / XXX) SHALL BE <br />PROVIDED. (SEE FIGURE 11A-1K.) <br />1127A.12.4 HEIGHT OF WORK SURFACES. THE TOPS OF TABLES AND COUNTERS SHALL BE 28 INCHES TO 34 INCHES (711 <br />MM TO 864 MM)FROM THE FINISH FLOOR. <br />EXCEPTION:WHEN FOOD OR DRINK IS SERVED FOR CONSUMPTION AT A COUNTER EXCEEDING 34 INCHES (864 MM) IN <br />HEIGHT, ONLY A PORTION OF THE MAIN COUNTER, 60 INCHES (1524 MM) MINIMUM IN LENGTH, SHALL BE <br />PROVIDED IN COMPLIANCE WITH THIS SECTION. <br />FIGURE 11A-1K <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />2'-6" MIN 3'-6" MIN <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />2'-6" MIN <br />1' <br />- <br />7 <br />" <br />MI <br />N <br />4'-0" MIN 1'-7" <br />MIN <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />AC <br />C <br />E <br />S <br />S <br />I <br />B <br />L <br />E <br />PA <br />T <br />H <br /> <br />O <br />F <br /> <br />T <br />R <br />A <br />V <br />E <br />L <br />SEC. 1133A KITCHENS - <br />SECTION 1133A KITCHENS <br />1133A.1 GENERAL. KITCHENS SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL COMPLY WITH THIS SECTION. <br />1133A.2 CLEAR FLOOR SPACE. CLEAR FLOOR SPACE AT KITCHENS SHALL COMPLY WITH THE FOLLOWING: <br />1. A CLEAR FLOOR SPACE AT LEAST 30 INCHES (762 MM) BY 48 INCHES ( 1219 MM) THAT ALLOWS A PARALLEL <br />APPROACH BY A PERSON IN A WHEELCHAIR SHALL BE PROVIDED AT THE RANGE OR COOKTOP; see figure <br />33.1(a) <br />2. CLEAR FLOOR SPACE AT LEAST 30 INCHES (762 MM) BY 48 INCHES (1219 MM) THAT ALLOWS EITHER A <br />PARALLEL OR FORWARD APPROACH SHALL BE PROVIDED AT THE KITCHEN SINK AND ALL OTHER <br />FIXTURES OR APPLIANCES INCLUDING THE OVEN, DISHWASHER, REFRIGERATOR/FREEZER AND TRASH <br />COMPACTOR; see figure 33.1(b) <br />3. THE CENTERLINE OF THE 30-INCH (762 MM) BY 48-INCH (1219 MM) CLEAR FLOOR SPACE PROVIDED FOR <br />PARALLEL OR FORWARD APPROACH SHALL BE ALIGNED WITH THE CENTERLINE OF THE APPLIANCE OR <br />FIXTURE. (see figure 33.1) <br />1133A.2.1 CLEAR WIDTH. KITCHENS SHALL HAVE A MINIMUM CLEAR WIDTH MEASURED BETWEEN ANY CABINET, <br />COUNTERTOP OR THE FACE OF ANY APPLIANCE (EXCLUDING HANDLES AND CONTROLS) THAT PROJECTS <br />INTO THE KITCHEN AND THE OPPOSING CABINET, COUNTERTOP, APPLIANCE OR WALL AS FOLLOWS: <br />1. U-SHAPED KITCHENS, DESIGNED WITH PARALLEL APPROACH AT A RANGE OR COOKTOP LOCATED AT THE <br />BASE OF THE U, SHALL HAVE A MINIMUM CLEAR WIDTH OF AT LEAST 60 INCHES ( 1524 MM); see figure <br />33.2(1). <br />2. U-SHAPED KITCHENS, DESIGNED WITH A COOKTOP OR SINK LOCATED AT THE BASE OF THE U, WHICH <br />PROVIDES A KNEE AND TOE SPACE IN ACCORDANCE WITH SECTION 1133A. 7 TO ALLOW FOR A FORWARD <br />APPROACH, SHALL HAVE A CLEAR WIDTH OF AT LEAST 48 INCHES (1219 MM); see figure 33.2(2). <br />3. ALL OTHER KITCHEN DESIGNS SHALL PROVIDE A MINIMUM CLEAR WIDTH OF AT LEAST 48 INCHES (1219 <br />MM); see figure 33.2(3). <br />1133A.3 REMOVABLE BASE CABINETS. BASE CABINETS DIRECTLY UNDER THE KITCHEN SINK COUNTER AREA, <br />INCLUDING TOE BOARD AND SHELVING, SHALL BE REMOVABLE WITHOUT THE USE OF SPECIALIZED TOOLS OR <br />SPECIALIZED KNOWLEDGE IN ORDER TO PROVIDE KNEE AND TOE SPACE FOR A WHEELCHAIR. THE FINISH <br />FLOOR BENEATH THE KITCHEN SINK COUNTER AREA SHALL BE EXTENDED TO THE WALL; see figure 33.3 <br />1133A.4 COUNTERTOPS. KITCHEN COUNTERTOPS SHALL COMPLY WITH THIS SECTION AND SHALL BE PROVIDED WITH <br />THE FOLLOWING (SEE SECTION1133A.4.1 FOR REPOSITIONABLE COUNTERTOP REQUIREMENTS): <br />1. A MINIMUM LINEAR LENGTH OF 30 INCHES (762 MM) OF COUNTERTOP SHALL BE PROVIDED FOR THE <br />KITCHEN SINK INSTALLATION. <br />2. A MINIMUM LINEAR LENGTH OF 30 INCHES (762 MM) OF COUNTERTOP SHALL BE PROVIDED FOR A WORK <br />SURFACE. <br />3.THE SINK AND WORK SURFACE MAY BE A SINGLE INTEGRAL UNIT, A MINIMUM OF 60 INCHES (1524 MM) IN <br />LENGTH, OR BE SEPARATE COMPONENTS. <br />EXCEPTION:TWO 15-INCH (381 MM) MINIMUM WIDTH BREADBOARDS MAY BE PROVIDED IN LIEU OF THE REQUIRED 30 <br />INCHES (762 MM) OF COUNTERTOP WORK SURFACE. <br />1133A.4.1 REPOSITIONABLE COUNTERTOPS. REPOSITIONABLE COUNTERTOPS SHALL BE PROVIDED IN A MINIMUM OF 5 <br />PERCENT OF THE COVERED MULTIFAMILY DWELLING UNITS. REPOSITIONABLE COUNTERTOPS SHALL COMPLY <br />WITH THE FOLLOWING: <br />1. THE KITCHEN SINK AND WORK SURFACE SPACE REQUIRED BY SECTION 1133A.4 SHALL BE DESIGNED TO <br />ENABLE REPOSITIONING TO A MINIMUM HEIGHT OF28 INCHES (711 MM). <br />2. BASE CABINETS DIRECTLY UNDER THE KITCHEN SINK COUNTER AREA AND WORK SURFACE SHALL BE <br />REMOVABLE AS REQUIRED IN SECTION 1133A.3. <br />3. THE SIDES OF ADJACENT CABINETS AND THE BACK WALL, WHICH MAY BECOME EXPOSED TO MOISTURE <br />OR FOOD HANDLING WHEN A COUNTERTOP IS LOWERED, SHALL BE CONSTRUCTED OF DURABLE, <br />NONABSORBENT MATERIALS APPROPRIATE FOR SUCH USES. <br />4. FINISHED FLOORING SHALL BE EXTENDED TO THE WALL BENEATH THE SINK AND WORK SURFACE. <br />EXCEPTIONS: <br />1. STONE, CULTURED STONE AND TILED COUNTERTOPS MAY BE USED WITHOUT MEETING THE REPOSITIONING <br />REQUIREMENTS. <br />2. TWO 15-INCH (381 MM) MINIMUM WIDTH BREADBOARDS MAY BE PROVIDED IN LIEU OF THE REQUIRED 30I <br />INCHES (762 MM) OF COUNTERTOP WORK SURFACE. <br />1133A.5 LOWER SHELVING. LOWER SHELVING AND/OR DRAWER SPACE SHALL BE PROVIDED IN THE KITCHEN AT A <br />HEIGHT OF NO MORE THAN 48 INCHES (1219 MM) ABOVE THE FLOOR. 1133A.6 KITCHEN SINK FAUCET <br />CONTROLS. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND <br />SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO <br />ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS (22.2N). LEVER-OPERATED, PUSH-TYPE AND <br />ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING <br />VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. <br />1133A.7 KNEE AND TOE SPACE. KNEE AND TOE SPACE, WHEN REQUIRED BY SECTION 1133A, SHALL COMPLY WITH THE <br />FOLLOWING: <br />1. THE KNEE AND TOE SPACE SHALL BE CLEAR AND UNOBSTRUCTED, OR REMOVABLE BASE CABINETS IN <br />COMPLIANCE WITH SECTION 1133A.3 SHALL BE PROVIDED. <br />2. THE KNEE AND TOE SPACE SHALL BE 30 INCHES (762 MM) WIDE MINIMUM, CENTERED ON THE SINK, <br />COUNTERTOP OR APPLIANCE. <br />3. THE KNEE SPACE SHALL BE AT LEAST 27 INCHES (686 MM) ABOVE THE FINISH FLOOR. <br />4. THE KNEE SPACE SHALL BE 11 INCHES (279 MM) DEEP MINIMUM AT 9 INCHES (229 MM) ABOVE THE FINISH <br />FLOOR, AND 8 INCHES (203 MM) DEEP MINIMUM AT 27 INCHES (686 MM) ABOVE THE FINISH FLOOR, <br />MEASURED FROM THE FRONT EDGE. <br />5.THE TOE SPACE SHALL BE AT LEAST 9 INCHES (229 MM) ABOVE THE FINISH FLOOR. <br />6. A CLEAR FLOOR SPACE SHALL NOT EXTEND INTO THE KNEE AND TOE SPACE MORE THAN 19 INCHES (483 <br />MM). <br />1133A.7.1 PLUMBING PROTECTION. WATER SUPPLY AND DRAIN PIPES UNDER KITCHEN SINKS SHALL BE INSULATED OR <br />OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER KITCHEN SINKS; see <br />figure 33.4. <br />DISHWASHER <br />see requirement for <br />functional clear space <br />when door is open <br />WALL OR MICROWAVE <br />OVEN <br />see requirement for <br />functional clear space <br />when door is open <br />TRASH COMPACTOR <br />see requirement for <br />functional clear space <br />when door is open <br />REFRIGERATOR <br />additional clearance <br />required when a wall <br />extends past the face of <br />the appliance <br />37" CLEAR <br />U.N.O. <br />DIM. AS <br />REQUIRED <br />DIM. AS <br />REQUIRED <br />DIM. AS <br />REQUIRED <br />4'-0" MIN <br />CLEAR WIDTH <br />3'-0" MIN <br />CLEAR PATH <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />CL <br />E <br />A <br />R <br /> <br />W <br />I <br />D <br />T <br />H <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br /> <br />C <br />L <br />E <br />A <br />R <br /> W <br />I <br />D <br />T <br />H <br />5' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />CL <br />E <br />A <br />R <br /> <br />W <br />I <br />D <br />T <br />H <br />5' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />CL <br />E <br />A <br />R <br /> <br />W <br />I <br />D <br />T <br />H <br />Two - 15" bread boards (CB) may <br />be provided in lieu of the 30" <br />countertop work surface with knee <br />and toe space or repositioning the <br />work surface countertop when <br />required by 1133A4.1 <br />refrigerator <br />sinkdishwasher <br />work surface <br />2'-1" MAX <br />the sides of adjacent cabinets and the <br />back wall, which may become exposed <br />to moisture or food handling when a <br />countertop is lowered, shall be <br />constructed of durable, nonabsorbent <br />materials <br />cabinet to be removable without the <br />use of specialized tools or knowledge <br />sinks with rear located drains simplify <br />knee space requirements of figure 33.4 <br />℄℄ <br />℄ <br />2'-2" MIN <br />9" <br />MI <br />N <br />2' <br />- <br />1 <br />0 <br />" <br /> <br />M <br />A <br />X <br />co <br />m <br />m <br />o <br />n <br /> <br />a <br />r <br />e <br />a <br /> <br />k <br />i <br />t <br />c <br />h <br />e <br />n <br />s <br />2' <br />- <br />3 <br />" <br /> <br />M <br />I <br />N <br />11" MIN <br /> counter top <br />knee/apron <br />toe <br />8" <br />MIN <br />3' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />dw <br />e <br />l <br />l <br />i <br />n <br />g <br /> <br />u <br />n <br />i <br />t <br /> <br />k <br />i <br />t <br />c <br />h <br />e <br />n <br />s <br />clearance required when a wall or cabinet <br />return extends past the face of the appliance <br />ra <br />n <br />g <br />e <br />A minimum 48" of clear width is <br />required when a sink or a cook top <br />with the required knee and toe <br />space is provided at the base of <br />U-shaped kitchens <br />When a door to an appliance is <br />open, functional clear floor space <br />must be provided. The forward <br />approach to the sink provides the <br />parallel front approach to <br />dishwasher when it's door is open; <br />see figure 16.1 for additional <br />information. <br />CB <br />A 60" diameter turning circle or <br />T-shaped turning space is required <br />at the base of u-shaped kitchens <br />CB <br />COOK TOP <br /> forward approach allowed <br />when knee & toe space is <br />provided under the cooktop <br />DIM. AS <br />REQUIRED <br />RANGE <br />see requirement for <br />functional clear space <br />when door is open <br />DIM. AS <br />REQUIRED <br />door <br />℄℄ <br />FIGURE 33.1 <br />CLEAR FLOOR SPACE <br />(a) <br />parallel approach <br />(b) <br />parallel or forward approach <br />door <br />door door <br />KITCHEN SINK <br />removable base cabinets <br />required see figure 33.4 <br />33" MIN. <br />U.N.O. <br />℄ <br />(c) <br />functional clear space <br />6"3'-6" <br />CLEAR <br />FHA requires functional space at all appliances <br />with a pull out or pull down door. The clear floor <br />space of adjacent appliances and the 36" wide <br />accessible path through the kitchen can be <br />combined to provide functional clear floor space. <br />At appliances with a pull down door, either a <br />parallel front approach or parallel side approach <br />using a 9" high toe space under the door when it <br />is pulled down can be used. See figure 33.2 (2) <br />for additional information <br />pa <br />r <br />a <br />l <br />l <br />e <br />l <br />si <br />d <br />e <br />DIM. AS <br />REQUIRED <br />door <br />pa <br />r <br />a <br />l <br />l <br />e <br />l <br />fr <br />o <br />n <br />t <br />SPECIFIED APPLIANCE <br />functional space required <br />when appliance has a pull <br />out or pull down door <br />VE <br />R <br />I <br />F <br />Y <br />℄ <br />30" MIN. <br />U.N.O. <br />WORK SURFACE <br />removable base cabinets <br />required see figure 33.4 <br />℄when a garbage disposal is provided, <br />the sink drain shall be located to the <br />rear of the sink so the disposal can be <br />mounted clear of the required knee & <br />toe space. <br />provide knee and toe space <br />aligned with the forward clear <br />floor space per figure 16.3 <br />work surface area <br />(shown cross-hatched) <br />2'-0" <br />MIN <br />2'-0" <br />MIN <br />1'-3" <br />MIN <br />1'-3" <br />MIN <br />forward <br />approach <br />parallel <br />approach <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />FIGURE 33.2 <br />CLEAR WIDTH <br />(1)U-shape kitchen with parallel approach at <br />range or cooktop located at the base of the U <br />(2)U-shape kitchen with a cooktop or <br />sink located at the base of the U <br />refrigerator work surface <br />door <br />dishwasher <br />si <br />n <br />k <br />pa <br />r <br />a <br />l <br />l <br />e <br />l <br />fr <br />o <br />n <br />t <br />range <br />wo <br />r <br />k <br /> <br />s <br />u <br />r <br />f <br />a <br />c <br />e <br />ra <br />n <br />g <br />e <br />refrigerator <br />dishwasher sink <br />pa <br />r <br />a <br />l <br />l <br />e <br />l <br />ap <br />p <br />r <br />o <br />a <br />c <br />h <br />60 <br />" <br /> <br />t <br />u <br />r <br />n <br />i <br />n <br />g <br />ci <br />r <br />c <br />l <br />e <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />CL <br />E <br />A <br />R <br /> <br />W <br />I <br />D <br />T <br />H <br />℄ <br />extend finish floor beneath the <br />kitchen sink counter area to the wall <br />FIGURE 33.3 <br />REMOVABLE BASE CABINETS <br />FIGURE 33.4 <br />KNEE AND TOE SPACE1'-7" MAX <br />faucet controls per 1133A.6 <br />knee and toe space per 1133A.7 <br />(shown shaded) <br />plumbing protection per 1133A.7.1 <br />at hot water and drain pipes provide <br />insulation or removable appearance <br />panel protection from hot surfaces <br />when a garbage disposal is provided, <br />the sink drain shall be located to the <br />rear of the sink so the disposal can <br />be mounted clear of the required <br />knee & toe space. <br />1' <br />- <br />2 <br />" <br />MI <br />N <br />2' <br />- <br />0 <br />" <br />MI <br />N <br />Typical outlet and / or switch <br />placement for side approach <br />access when top of receptacle <br />box is mounted no higher <br />than 46" above the finish floor <br />(see detail 36 this sheet) <br />Typical outlet location <br />required by C.E.C. <br />3'-2" MIN <br />3'-2" MIN <br />1' <br />- <br />2 <br />" <br />MI <br />N <br />See figure 33.2(3) below for <br />additional information <br />3'-2" MIN <br />1' <br />- <br />2 <br />" <br />MI <br />N <br />See figure 33.2(3) below for <br />additional information <br />(3) All other kitchen designs (see figure 33.1 <br />for clear floor space requirements at fixtures and appliances for all <br />clear width figures) <br />SEC. 1136A CONTROL HEIGHTS - <br />SECTION 1136A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS <br />1136A.1 RECEPTACLE HEIGHTS. ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS <br />AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 48 INCHES (1219 MM) <br />MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX NOR LESS THAN 15 INCHES ( 381 MM) <br />MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX TO THE LEVEL OF THE FINISHED FLOOR <br />OR WORKING PLATFORM. <br />IF THE REACH IS OVER A PHYSICAL BARRIER OR AN OBSTRUCTION (FOR EXAMPLE, A KITCHEN BASE <br />CABINET), RECEPTACLES SHALL BE LOCATED WITHIN THE REACH RANGES SPECIFIED IN SECTION 1138A.3 <br />(see detail XX / XXX). PHYSICAL BARRIERS AND OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25 INCHES <br />(635 MM) FROM THE WALL BENEATH THE RECEPTACLE. <br />RECEPTACLE OUTLETS THAT DO NOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE PROVIDED <br />THAT COMPARABLE RECEPTACLE OUTLETS, THAT PERFORM THE SAME FUNCTIONS, ARE PROVIDED WITHIN <br />THE SAME AREA AND ARE ACCESSIBLE. <br />EXCEPTIONS: <br />1. RECEPTACLE OUTLETS INSTALLED AS PART OF PERMANENTLY INSTALLED BASEBOARD HEATERS ARE <br />EXEMPT. <br />2. REQUIRED RECEPTACLE OUTLETS SHALL BE PERMITTED IN FLOORS WHEN ADJACENT TO SLIDING PANELS <br />OR WALLS. <br />3. BASEBOARD ELECTRICAL OUTLETS USED IN RELOCATABLE PARTITIONS, WINDOW WALLS OR OTHER <br />ELECTRICAL CONVENIENCE FLOOR OUTLETS ARE NOT SUBJECT TO THE MINIMUM HEIGHT REQUIREMENTS. <br />4. THIS SECTION SHALL NOT APPLY TO EXISTING BUILDINGS WHEN THE ENFORCING AGENCY DETERMINES <br />THAT COMPLIANCE WITH THESE STANDARDS WOULD CREATE AN UNREASONABLE HARDSHIP. <br />1136A.2 SWITCH AND CONTROL HEIGHTS. CONTROLS OR SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF <br />THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, ALARMS OR <br />COOLING, HEATING AND VENTILATING EQUIPMENT SHALL BE LOCATED NO MORE THAN 48 INCHES (1219 MM) <br />MEASURED FROM THE TOP OF THE OUTLET BOX NOR LESS THAN 15 INCHES (381 MM) MEASURED FROM THE <br />BOTTOM OF THE OUTLET BOX TO THE LEVEL OF THE FINISHED FLOOR OR WORKING PLATFORM. {F THE <br />REACH IS OVER A PHYSICAL BARRIER OR AN OBSTRUCTION (FOR EXAMPLE, A KITCHEN BASE CABINET) <br />SWITCHES AND CONTROLS SHALL BE LOCATED WITHIN THE REACH RANGES SPECIFIED IN SECTION 1138A.3 <br />(see detail XX / XXX). PHYSICAL BARRIERS OR OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25 INCHES <br />(635 MM) FROM THE WALL BENEATH A CONTROL. <br />SWITCHES AND CONTROLS THAT DO NOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE <br />PROVIDED THAT COMPARABLE CONTROLS OR OUTLETS, THAT PERFORM THE SAME FUNCTIONS, ARE <br />PROVIDED WITHIN THE SAME AREA AND ARE ACCESSIBLE. <br />EXCEPTION:APPLIANCES (E.G., KITCHEN STOVES, DISHWASHERS, RANGE HOODS, MICROWAVE OVENS AND SIMILAR <br />APPLIANCES) WHICH HAVE CONTROLS LOCATED ON THE APPLIANCE. <br />FIGURE 36A <br />MOUNTING HEIGHT FOR OUTLETS <br />1' <br />- <br />3 <br />" <br />MI <br />N <br />4' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />A0.14 <br />DWELLING ADA <br />NOTES DETAILS <br />SCALE: N/A <br />13 <br />45