Laserfiche WebLink
32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG <br />A0.15 <br />DWELLING ADA <br />NOTES DETAILS <br />SCALE: N/A <br />SEC. 1111A CHANGES IN LEVEL - <br />SECTION 1111A CHANGES IN LEVEL ON ACCESSIBLE ROUTES <br />1111A.1 CHANGES IN LEVEL NOT EXCEEDING 1/2 INCH. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE <br />SHALL NOT EXCEED 1/2 INCH ( 12. 7 MM). WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED <br />WITH A SLOPE NO GREATER THAN 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL (50-PERCENT SLOPE). CHANGES <br />IN LEVEL NOT EXCEEDING 114 INCH (6.35 MM) MAY BE VERTICAL. <br />1111A.2 CHANGES GREATER THAN 1/2 INCH. CHANGES IN LEVEL GREATER THAN 1/2 INCH ( 12.7 MM) SHALL BE MADE <br />BY MEANS OF A SLOPED SURFACE NOT GREATER THAN 1 UNIT VERTICAL IN 20 UNITS HORIZONTAL( <br />5-PERCENT SLOPE), OR A CURB RAMP, RAMP, ELEVATOR OR PLATFORM (WHEELCHAIR) LIFT. STAIRS SHALL <br />NOT BE PART OF AN ACCESSIBLE ROUTE. WHEN STAIRS ARE LOCATED ALONG OR ADJACENT TO AN <br />ACCESSIBLE ROUTE THEY SHALL COMPLY WITH SECTION 1115A FOR EXTERIOR STAIRWAYS. <br />CHAPTER 11A DIVISION III - <br />CHAPTER 11A HOUSING ACCESSIBILITY <br />DIVISION III BUILDING FEATURES <br />NOTE:1.FOR PUBLIC USE FACILITIES, SEE CHAPTER 11B OF THIS CODE; SHEET SERIES XXX. <br />2.FOR CHAPTER 11A DIVISION I, APPLICATION AND GENERAL PROVISIONS, SECTIONS 1101A <br />THROUGH 1107,SEE SHEET XXX. <br />3.FOR CHAPTER 11A DIVISION II, EXTERIOR FACILITIES, SECTIONS 1108A THROUGH 1116, SEE <br />SHEETS XXX AND XXX. <br />4.FOR CHAPTER 11A DIVISION III, COMMON USE FACILITIES, SECTION 1127A, SEE SHEETS XXX <br />AND XXX. <br />5.FOR CHAPTER 11A DIVISION IV DWELLING UNIT FEATURES, SECTIONS 1128A THROUGH 1136A, <br />SEE SHEETS XXX. <br />FOR CHAPTER 11A DIVISION V, FEATURES COMMON TO EXTERIOR AND INTERIOR OF BUILDINGS, <br />SECTIONS 1137A THROUGH 1143A, SEE SHEETS XXX. <br />DIVISION III TABLE OF CONTENTS <br />SECTION 1117A GENERAL REQUIREMENTS FOR ACCESSIBLE ENTRANCES, EXITS, INTERIOR ROUTES OF <br />TRAVEL AND FACILITY ACCESSIBILITY (see detail XX this sheet) <br />SECTION 1118A EGRESS AND AREAS OF REFUGE (see detail XX this sheet) <br />SECTION 1119A INTERIOR ROUTES OF TRAVEL (see detail XX this sheet) <br />SECTION 1120A INTERIOR ACCESSIBLE ROUTES (see detail XX this sheet) <br />SECTION 1121A CHANGES IN LEVEL ON ACCESSIBLE ROUTES (see detail XX this sheet) <br />SECTION 1122A INTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES (see detail XX this sheet) <br />SECTION 1123A INTERIOR STAIRWAYS (see detail XX this sheet) <br />SECTION 1124A ELEVATORS AND PLATFORM (WHEELCHAIR) LIFTS (see detail XX this sheet) <br />SECTION 1125A HAZARDS ON ACCESSIBLE ROUTES (see detail XX / XXX) <br />SECTION 1126A DOORS (see detail XX / XX) <br />SECTION 1127 A COMMON USE FACILITIES (see sheets XXX and XXX) <br />SECTION 1121A CHANGES IN LEVEL ON ACCESSIBLE ROUTES <br />1121A.1 CHANGES IN LEVEL NOT EXCEEDING 1/2 INCH. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE <br />SHALL NOT EXCEED 1/2 INCH (12.7 MM). WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED WITH A <br />SLOPE NO GREATER THAN 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL (50-PERCENT SLOPE). CHANGES IN LEVEL <br />NOT EXCEEDING 114 INCH (6.35 MM) MAY BE VERTICAL. <br />1121A.2 CHANGES GREATER THAN 1/2 INCH. CHANGES IN LEVEL GREATER THAN 1/2 INCH ( 12.7 MM) SHALL BE MADE BY <br />MEANS OF A SLOPED SURFACE NOT GREATER THAN 1 UNIT VERTICAL IN 20 UNITS HORIZONTAL (5-PERCENT <br />SLOPE), OR A CURB RAMP, RAMP, ELEVATOR OR PLATFORM (WHEELCHAIR) LIFT. STAIRS SHALL NOT BE PART OF <br />AN ACCESSIBLE ROUTE. WHEN STAIRS ARE LOCATED ALONG OR ADJACENT TO AN ACCESSIBLE ROUTE THEY <br />SHALL COMPLY WITH SECTION 1123A (see detail XX this sheet) FOR INTERIOR STAIRWAYS. <br />1/ <br />4 <br />" <br />MA <br />X <br />1/ <br />4 <br />" <br />MA <br />X <br />1/ <br />4 <br />" <br />MA <br />X <br />1/ <br />2 <br />" <br />MA <br />X <br />SEC. 1121A CHANGES IN LEVEL ON ROUTES - <br />(a) <br />vertical level change <br />(a) <br />beveled level change <br />2 <br />1 <br />SEC. 1126A DOORS - <br />SECTION 1126A DOORS <br />1126A.1 WIDTH AND HEIGHT OF DOORS. DOORWAYS WHICH PROVIDE ACCESS TO COMMON USE AREAS OR COVERED <br />MULTIFAMILY DWELLINGS SHALL COMPLY WITH THE FOLLOWING: <br />1. PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 36 INCHES (914 MM) IN WIDTH, NOT LESS THAN 80 <br />INCHES (2032 MM) IN HEIGHT AND PROVIDE A CLEAR WIDTH OF NOT LESS THAN 32 INCHES (813 MM), <br />MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. <br />2. BE CAPABLE OF OPENING AT LEAST 90 DEGREES. <br />3. A PAIR OF DOORS, MANUAL OR AUTOMATIC, MUST HAVE AT LEAST ONE LEAF WHICH PROVIDES A CLEAR <br />WIDTH OF NOT LESS THAN 32 INCHES (813 MM), MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF <br />90 DEGREES FROM ITS CLOSED POSITION. <br />4. THE WIDTH OF ANY COMPONENT IN THE EGRESS SYSTEM SHALL NOT BE LESS THAN THE MINIMUM WIDTH <br />REQUIRED BY CBC SECTION 1005. REVOLVING DOORS SHALL NOT BE USED AS REQUIRED ENTRANCES FOR <br />PERSONS WITH DISABILITIES. <br />1126A.2 LEVEL FLOOR OR LANDING. THE FLOOR OR LANDING ON EACH SIDE OF AN EXIT DOOR SHALL BE LEVEL. (SEE <br />CBC CHAPTER 10). <br />1126A.2.1 THRESHOLDS AND CHANGES IN ELEVATION AT DOORS. THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/ 2 <br />INCH (12. 7 MM) LOWER THAN THE TOP OF THE THRESHOLD OF THE DOORWAY. (SEE FIGURE 11A-8I). CHANGES <br />IN LEVEL BETWEEN 1/ 4 INCH (6.35 MM) AND 1/ 2 INCH ( 12.7 MM) SHALL BE BEVELED WITH A SLOPE NO GREATER <br />THAN 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL (50% SLOPE). CHANGES IN LEVEL GREATER THAN 1/ 2 INCH (12. <br />7 MM) SHALL BE ACCOMPLISHED BY MEANS OF A RAMP (SEE SECTION 1122A; see detail XX / XXX). <br />1126A.3 MANEUVERING CLEARANCES AT DOORS. <br />1126A.3.1 GENERAL. THE LEVEL FLOOR OR LANDING OF AN EXIT DOOR SHALL HAVE A LENGTH IN THE DIRECTION OF THE <br />DOOR SWING OF AT LEAST 60 INCHES (1524 MM) AND A LENGTH OPPOSITE THE DIRECTION OF THE DOOR <br />SWING OF AT LEAST 44 INCHES (1118 MM) MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS <br />CLOSED POSITION. (SEE FIGURES 11A-8D, 11A-8E AND 11A-8F FOR MANEUVERING SPACES AT SLIDING DOORS). <br />1126A.3.2 STRIKE EDGE MANEUVERING SPACE. THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR <br />SWINGS SHALL EXTEND AT LEAST 24 INCHES (610 MM) PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR <br />DOORS AND AT LEAST 18 INCHES (457 MM) PAST THE STRIKE EDGE FOR INTERIOR DOORS. NOTE: <br />TWENTY-FOUR INCHES (610 MM) IS PREFERRED FOR STRIKE-SIDE CLEARANCE. <br />1126A.3.2.1 FRONT APPROACH. THE FOLLOWING PROVISIONS SHALL APPLY TO SWINGING DOORS WITH FRONT APPROACH: <br />1. FOR PULL SIDE APPROACH, THE LEVEL FLOOR OR LANDING SHALL EXTEND IN THE DIRECTION OF THE <br />DOOR SWING AT LEAST 60 INCHES (1524 MM). (SEE FIGURE 11A-8A). <br />2. FOR PUSH SIDE APPROACH, THE LEVEL FLOOR OR LANDING SHALL EXTEND OPPOSITE THE DIRECTION OF <br />THE DOOR SWING AT LEAST 48 INCHES (1219 MM). (SEE FIGURE 11A-8A). <br />3.DOORS WITH PUSH SIDE APPROACH HAVING BOTH A CLOSER AND A LATCH SHALL BE PROVIDED WITH A <br />CLEAR AND LEVEL AREA EXTENDING A MINIMUM OF 12 INCHES ( 305 MM) PAST THE STRIKE EDGE ON THE <br />APPROACH SIDE OF THE DOOR. (SEE FIGURE 11A-8A). <br />1126A.3.2.2 HINGE SIDE APPROACH. THE FOLLOWING PROVISIONS SHALL APPLY TO SWINGING DOORS WITH HINGE SIDE <br />APPROACH: <br />1. DOORS WITH PULL SIDE APPROACH SHALL BE PROVIDED WITH A LEVEL FLOOR OR LANDING NOT LESS <br />THAN 60 INCHES (1524 MM) IN DEPTH. A CLEAR AND LEVEL AREA SHALL EXTEND A MINIMUM OF 36 INCHES <br />(914 MM) PAST THE STRIKE EDGE ON THE APPROACH SIDE OF THE DOOR. (SEE FIGURE 11A-8B). <br />EXCEPTION: DOORS WITH PULL SIDE APPROACH AND A LEVEL FLOOR OR LANDING GREATER THAN 60 <br />INCHES ( 1524 MM) IN DEPTH SHALL BE PROVIDED WITH A CLEAR AND LEVEL AREA AT LEAST 24 <br />INCHES (610 MM) PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND AT LEAST 18 <br />INCHES (457 MM) PAST THE STRIKE EDGE FOR INTERIOR DOORS. <br />FIGURE 11A-8D <br />FRONT APPROACH- SLIDING DOORS AND FOLDING DOORS <br /> 1'-10" <br /> MIN 2'-0" MIN <br />3' <br />- <br />8 <br />" <br /> <br />M <br />I <br />N <br />3' <br />- <br />8 <br />" <br /> <br />M <br />I <br />N <br />FIGURE 11A-8I <br />THRESHOLDS <br />1/ <br />2 <br />" <br />MA <br />X <br />1/ <br />4 <br />" <br />MA <br />X <br />1: <br />2 <br /> <br />M <br />A <br />X <br /> S <br />L <br />O <br />P <br />E <br />2 <br />1 <br />FIGURE 11A-8A <br />FRONT APPROACHES -SWINGING DOORS <br />1'-0" <br />MIN <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />(b) <br />front approach, push side <br />1'-6" <br />MIN <br />5' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />(a) <br />front approach, pull side <br />Add 6 inches <br />at exterior side <br />of exterior door. <br />provide this <br />additional space if door is <br />equipped with both a latch <br />and a closer <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />2'-8" <br />CLEAR <br />FIGURE 11A-8F <br />STOP OR LATCH SIDE APPROACH SLIDING <br />DOORS AND FOLDING DOORS <br />FIGURE 11A-8E <br />POCKET OR HINGE SIDE APPROACH SLIDING <br />DOORS AND FOLDING DOORS <br />2'-8" <br />CLEAR <br />2'-8" <br />CLEAR <br />FIGURE 11A-8B <br />HINGE SIDE APPROACHES -SWINGING DOORS <br />'Y <br />' <br />3' <br />- <br />8 <br />" <br /> <br />M <br />I <br />N <br />(b) <br />hinge approach, push side <br />(a) <br />hinge approach, pull side <br />'Y <br />' <br />'X' <br />NOTE:'X' = 36" minimum if 'Y' = 60" 'X' = <br />42" minimum if 'Y' = 54" <br />NOTE:'Y' = 48" min if <br />door has both a <br />latch and a <br />closer <br />4'-6" <br />FIGURE 11A-8C <br />LATCH SIDE APPROACHES -SWINGING DOORS <br />'Y <br />' <br />3' <br />- <br />8 <br />" <br /> <br />M <br />I <br />N <br />(b) <br />latch approach, push side <br />(a) <br />latch approach, pull side <br />'Y <br />' <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />2'-0" <br />MIN <br />NOTE:'Y' = 54" minimum if <br />door has a closure <br />NOTE:'Y' = 48" min if <br />door has <br />a closer <br />2'-0" <br />MIN <br />(b) <br />doors at opposite walls <br />FIGURE 11A-8H <br />VESTIBULES <br />(serving other than a required exit stairway) <br />4'-0" MIN <br />(a) <br />doors at adjacent walls <br />4'-0 <br />" <br /> <br />M <br />I <br />N <br />1' <br />- <br />6 <br />" <br />MI <br />N <br />1' <br />- <br />6 <br />" <br />MI <br />N <br />FIGURE 11A-8G <br />VESTIBULES <br />(serving other than a required exit stairway) <br />(b) <br />both doors open out <br />4'-0" MIN4'-0" MIN <br />1' <br />- <br />6 <br />" <br />MI <br />N <br />1' <br />- <br />0 <br />" <br /> <br />* <br />MI <br />N <br />(b) <br />doors in series <br />1' <br />- <br />0 <br />" <br /> <br />* <br />MI <br />N <br />* provide this additional space if <br />door is equipped with both a latch <br />and a closer <br />SEC. 1130A ACCESSIBLE ROUTE WITHIN UNITS - <br />SECTION 1130A ACCESSIBLE ROUTE WITHIN COVERED MULTIFAMILY DWELLING UNITS <br />1130A.L GENERAL. AN ACCESSIBLE ROUTE SHALL BE PROVIDED THROUGH ALL ROOMS AND SPACES OF THE <br />DWELLING UNIT. THE ACCESSIBLE ROUTE SHALL PASS THROUGH THE PRIMARY ENTRY DOOR, AND SHALL <br />CONNECT WITH ALL ADDITIONAL EXTERIOR DOORS, REQUIRED CLEAR FLOOR SPACES AT KITCHEN <br />APPLIANCES AND BATHROOM FIXTURES. FOR THE PURPOSE OF THIS SECTION, "ACCESSIBLE ROUTES" MAY <br />INCLUDE HALLWAYS, CORRIDORS AND RAMPS. EXCEPTION: AN ACCESSIBLE ROUTE IS NOT REQUIRED FROM <br />THE INTERIOR OF THE UNIT INTO A BASEMENT OR GARAGE, EXCEPT AS PROVIDED IN SECTION 1105A.1. (see <br />XX / XXX) <br />1130A.2 WIDTH. THE ACCESSIBLE ROUTE INTO AND THROUGHOUT COVERED MULTIFAMILY DWELLING UNITS SHALL <br />BE AT LEAST 36 INCHES (914 MM) WIDE. <br />SEC. 1131A CHANGES IN LEVEL ON ROUTES - <br />SECTION 1131 A CHANGES IN LEVEL ON ACCESSIBLE ROUTES <br />1131A.1 CHANGES IN LEVEL NOT EXCEEDING 1/2 INCH. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE <br />SHALL NOT EXCEED 1/2 INCH ( 12.7 MM). WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED <br />WITH A SLOPE NO GREATER THAN 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL (50-PERCENT SLOPE). CHANGES <br />IN LEVEL NOT EXCEEDING 1/4 INCH (6.35 MM) MAY BE VERTICAL. 444 1131A.2 CHANGES GREATER THAN 1/2 <br />INCH. CHANGES IN LEVEL GREATER THAN 1/2 INCH ( 12.7 MM) SHALL BE MADE BY MEANS OF A RAMP, <br />ELEVATOR OR PLATFORM (WHEELCHAIR) LIFT. SEE SECTION 1122A FOR RAMPS (see XX / XXX) AND SECTION <br />1124A.11 FOR PLATFORM (WHEELCHAIR) LIFTS (see XX / XXX). <br />1/ <br />4 <br />" <br />MA <br />X <br />1/ <br />4 <br />" <br />MA <br />X <br />1/ <br />4 <br />" <br />MA <br />X <br />1/ <br />2 <br />" <br />MA <br />X <br />(a) <br />vertical change in level <br />(b) <br />beveled change in level <br />2 <br />1 <br />FIGURE 11A-1F <br />CHANGE IN LEVEL <br />SEC. 1132A DOORS - <br />SECTION 1132A DOORS <br />1132A.1 PRIMARY ENTRY DOORS AND REQUIRED EXIT DOORS. THE WIDTH AND HEIGHT OF PRIMARY ENTRY <br />DOORS AND ALL REQUIRED EXIT DOORS SHALL COMPLY WITH SECTION 1126A.1. THE REQUIREMENTS OF <br />SECTIONS 1126A.3 SHALL APPLY TO MANEUVERING CLEARANCES AT THE SIDE OF THE DOOR EXPOSED <br />TO COMMON OR PUBLIC USE SPACES (E.G., ENTRY OR EXIT DOORS WHICH OPEN FROM THE COVERED <br />MULTIFAMILY DWELLING UNIT INTO A CORRIDOR, HALLWAY OR LOBBY, OR DIRECTLY TO THE OUTSIDE). <br />1132A.2 INTERIOR DOORS AND SECONDARY EXTERIOR DOORS. EXCEPT AS ALLOWED BY SECTION 1109A.2 (see XX <br />/ XXX), INTERIOR DOORS INTENDED FOR USER PASSAGE AND SECONDARY EXTERIOR DOORS SHALL <br />COMPLY WITH THIS SECTION. THE PROVISIONS OF THIS SECTION SHALL APPLY TO THE DWELLING UNIT <br />SIDE OF DOORS LEADING FROM THE INTERIOR OF THE DWELLING UNIT TO AN UNFINISHED BASEMENT OR <br />AN ATTACHED GARAGE. <br />1132A.3 WIDTH AND HEIGHT OF INTERIOR DOORS AND SECONDARY EXTERIOR DOORS. DOORS SHALL COMPLY <br />WITH THE FOLLOWING: <br />1. DOORS SHALL NOT BE LESS THAN 6 FEET 8 INCHES (2032 MM) IN HEIGHT. <br />2. SWINGING DOORS SHALL PROVIDE A NET CLEAR OPENING WIDTH OF NOT LESS THAN 32 INCHES (813 <br />MM), MEASURED WITH THE DOOR OR DOORS POSITIONED AT AN ANGLE OF 90 DEGREES FROM THE <br />CLOSED POSITION. A 34-INCH (864 MM) DOOR IS ACCEPTABLE. <br />3. SWINGING DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES. <br />4. A NOMINAL 32-INCH (813 MM) CLEAR OPENING PROVIDED BY A STANDARD 6-FOOT WIDE (1829 MM) <br />SLIDING PATIO DOOR ASSEMBLY IS ACCEPTABLE. <br />5. A PAIR OF DOORS, MANUAL OR AUTOMATIC, MUST HAVE AT LEAST ONE LEAF WHICH PROVIDES A <br />CLEAR WIDTH OF NOT LESS THAN 32 INCHES (813 MM), MEASURED WITH THE DOOR POSITIONED <br />AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. <br />6. THE WIDTH OF ANY COMPONENT IN THE MEANS OF EGRESS SYSTEM SHALL NOT BE LESS THAN THE <br />MINIMUM WIDTH REQUIRED BY SECTION 1005. <br />1132A.4 LEVEL FLOOR OR LANDING. SEE ALSO CHAPTER 10. THE FLOOR OR LANDING ON EACH SIDE OF A DOOR <br />SHALL BE LEVEL. PRIMARY ENTRY DOORS, REQUIRED EXIT DOORS OR SECONDARY EXTERIOR DOORS <br />WITH CHANGES IN HEIGHT BETWEEN THE INTERIOR SURFACE OR FLOOR LEVEL AND THE EXTERIOR <br />SURFACE OR FLOOR LEVEL SHALL COMPLY WITH THE FOLLOWING: <br />1.EXTERIOR LANDINGS OF IMPERVIOUS CONSTRUCTION (E.G., CONCRETE, BRICK, FLAGSTONE) <br />SERVING PRIMARY ENTRY DOORS AND REQUIRED EXIT DOORS ARE LIMITED TO NOT MORE THAN <br />1/2 INCH (12.7 MM) OF CHANGE IN HEIGHT BETWEEN FLOOR SURFACES. CHANGES IN LEVEL SHALL <br />COMPLY WITH SECTION 1131 A. (see Figure 32.3 and detail 31 this sheet) <br />2. EXTERIOR LANDINGS OF PERVIOUS CONSTRUCTION (E.G., WOOD DECKING WITH SPACES) SHALL <br />BE THE SAME LEVEL AS THE INTERIOR LANDING, EXCEPT THAT SECONDARY EXTERIOR DOORS <br />MAY HAVE NO MORE THAN 1/2 INCH (12.7 MM) OF CHANGE IN HEIGHT BETWEEN FLOOR SURFACES. <br />CHANGES IN LEVEL SHALL COMPLY WITH SECTION 1131 A. (see detail 31 this sheet) <br />3. SECONDARY EXTERIOR DOORS ONTO DECKS, PATIOS OR BALCONY SURFACES CONSTRUCTED OF <br />IMPERVIOUS MATERIALS (E.G., CONCRETE, BRICK, FLAGSTONE) MAY HAVE A MAXIMUM CHANGE IN <br />HEIGHT FROM THE INTERIOR LANDING OF4 INCHES (101.6 MM). CHANGES IN HEIGHT GREATER <br />THAN 1/ 2 INCH (12.7 MM) SHALL BE ACCOMPLISHED BY MEANS OF A RAMP COMPLYING WITH <br />SECTION 1114A (see XX / XXX) OR BY MEANS OF A PLATFORM CONSTRUCTED TO THE LEVEL OF <br />THE FLOOR AS ILLUSTRATED IN FIGURE 11A -8J. (see Figure 32.3 for change of height up to 1/2") <br />4. SECONDARY EXTERIOR DOORS ONTO DECKS, PATIOS OR BALCONY SURFACES CONSTRUCTED OF <br />IMPERVIOUS MATERIALS (E.G., CONCRETE, BRICK, FLAGSTONE) MAY HAVE A MAXIMUM CHANGE IN <br />HEIGHT FROM THE INTERIOR LANDING OF 1 INCH (25.4 MM), PROVIDED A RAMP WITH A MAXIMUM <br />SLOPE OF 1:8 IS PERMANENTLY INSTALLED. (SEE FIGURE 11A-8K.) <br />5. IN BUILDINGS CONTAINING COVERED MULTIFAMILY DWELLING UNITS, THE FLOOR OR LANDING <br />IMMEDIATELY OUTSIDE THE ENTRY MAY BE SLOPED UP TO 1/4 INCH (6.35 MM) PER FOOT (12 INCHES) ( 305 <br />MM ), IN A DIRECTION AWAY FROM THE PRIMARY ENTRANCE OF THE DWELLING UNIT FOR <br />DRAINAGE.1132A.4.1 THRESHOLDS. THRESHOLDS AT THE PRIMARY ENTRY AND REQUIRED EXIT DOORS <br />SHALL BE NO HIGHER THAN 1/2 INCH (12.7 MM ). THRESHOLDS AT SECONDARY EXTERIOR DOORS, <br />INCLUDING SLIDING DOOR TRACKS, SHALL BE NO HIGHER THAN 3/4 INCH (19.05 MM). CHANGES IN HEIGHT <br />AT INTERIOR DOOR THRESHOLDS (E.G., FLOOR MATERIAL CHANGES AT DOOR THRESHOLDS)SHALL NOT <br />EXCEED 1/2 INCH (12.7 MM). THRESHOLDS SHALL COMPLY WITH THE FOLLOWING: <br />1. THRESHOLDS WITH A CHANGE IN HEIGHT OF NOT MORE THAN 1/4 INCH (6.35 MM) MAY BE <br />VERTICAL. <br />2. THRESHOLDS WITH A CHANGE IN HEIGHT BETWEEN 1/4 INCH (6.35 MM) AND 3/4 INCH (19.05 MM) <br />SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL <br />(50-PERCENT SLOPE). <br />1132A.5 MANEUVERING CLEARANCES AT DOORS. <br />1132A.5.1 GENERAL. MANEUVERING CLEARANCES AT INTERIOR DOORS SHALL PROVIDE A MINIMUM LENGTH ON <br />BOTH SIDES OF THE DOOR OF AT LEAST 42 INCHES (1067 MM) MEASURED AT A RIGHT ANGLE TO THE <br />PLANE OF THE DOOR IN ITS CLOSED POSITION (see figure 32.1). <br />EXCEPTIONS: <br />1. A 39-INCH (991 MM) LENGTH IS ACCEPTABLE WHEN A MINIMUM CLEAR OPENING WIDTH OF 34 INCHES (864 <br />MM) IS PROVIDED. <br />2. THE FLOOR OR LANDING ON THE DWELLING UNIT SIDE OF THE PRIMARY ENTRY DOOR AND ANY <br />REQUIRED EXIT DOOR SHALL HAVE A MINIMUM LENGTH OF NOT LESS THAN 44 INCHES (1118 MM). <br />SECTION 1126A.3 SHALL APPLY TO MANEUVERING CLEARANCES AT THE SIDE OF THE DOOR EXPOSED TO <br />COMMON OR PUBLIC USE SPACES (see 2XX / XXX). <br />1132A.5.2 STRIKE EDGE MANEUVERING SPACE AT DOORS. THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH <br />THE DOOR SWINGS SHALL EXTEND 18 INCHES (457 MM) PAST THE STRIKE EDGE FOR ALL DOORS (see <br />figure 32.1). THE WIDTH OF THE LEVEL AREA AT THE EXTERIOR SIDE OF THE PRIMARY ENTRY DOOR AND <br />ANY REQUIRED EXIT DOORS SHALL COMPLY WITH SECTION 1126A (see XX / XXX). <br />NOTES: <br />1. SEE SECTION 1134A (see detail 34 this sheet) FOR BATHROOMS THAT ARE REQUIRED TO BE ACCESSIBLE. <br />2. TWENTY-FOUR INCHES (610 MM) IS PREFERRED FOR STRIKE EDGE CLEARANCE. <br />1132A.6 CLOSER-EFFORT TO OPERATE DOORS. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8-1/ 2 <br />POUNDS (38 N) FOR EXTERIOR DOORS AND 5 POUNDS (22 N) FOR INTERIOR DOORS, SUCH PULL OR PUSH <br />EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND THE CENTER PLANE OF SLIDING OR <br />FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO <br />MEET THESE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE <br />DOOR MAY BE INCREASED TO THE MINIMUM ALLOWABLE BY THE APPROPRIATE ENFORCEMENT AGENCY, <br />NOT TO EXCEED 15 POUNDS (66.7 N).1132A.7 TYPE OF LOCK OR LATCH. THE TYPE OF LATCH AND LOCK <br />REQUIRED FOR ALL DOORS SHALL BE IN ACCORDANCE WITH SECTION 1132A.8 AND CHAPTER 10, SECTION <br />1008. <br />1132A.8 HAND-ACTIVATED DOOR HARDWARE. HAND-ACTIVATED DOOR LATCHING, LOCKING AND OPENING <br />HARDWARE SHALL BE CENTERED BETWEEN 30 INCHES (762 MM) AND 44 INCHES (1118 MM) ABOVE THE <br />FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND ON AN ACCESSIBLE ROUTE <br />SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER-TYPE HARDWARE, PANIC BARS, PUSH-PULL <br />ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE <br />ABILITY TO GRASP THE OPENING HARDWARE. LOCKED EXIT DOORS SHALL OPERATE CONSISTENT WITH <br />SECTION 1132A.6, IN THE DIRECTION OF EGRESS (see figure 32.2). <br />1132A.8.1 LEVER-TYPE HARDWARE. THE LEVER OR LEVER OF ACTUATED LATCHES OR LOCKS SHALL BE CURVED <br />WITH A RETURN TO WITHIN 1/2 INCH (12.7 MM) OF THE DOOR TO PREVENT CATCHING ON THE CLOTHING <br />OF PERSONS DURING EGRESS IN GROUP 'R' AND 'U' OCCUPANCIES WITH AN OCCUPANT LOAD GREATER <br />THAN 10. <br />1132A.9 SMOOTH SURFACE. THE BOTTOM 10 INCHES (254 MM) OF ALL DOORS SHALL HAVE A SMOOTH, <br />UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT <br />CREATING A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE USED, A <br />10-INCH-HIGH (254 MM) SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR WHICH <br />WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR <br />HAZARDOUS CONDITION (see figure 32.2). <br />EXCEPTION:AUTOMATIC AND SLIDING DOORS. <br />1132A.10 DOOR SIGNAL DEVICES. EVERY PRIMARY ENTRANCE TO A COVERED MULTIFAMILY DWELLING UNIT SHALL <br />BE PROVIDED WITH A DOOR BUZZER, BELL, CHIME OR EQUIVALENT. THE ACTIVATING MECHANISM SHALL <br />BE MOUNTED A MAXIMUM OF 48 INCHES (1219 MM) ABOVE THE FLOOR AND CONNECTED TO PERMANENT <br />WIRING (see figure 32.2). <br />9" <br />MA <br />X <br />2 <br />1 <br />FIGURE 11A-8J <br />PLATFORM AT SECONDARY EXTERIOR DOOR <br />platform of approved <br />materials to raise floor <br />level of balcony; <br />platform required for <br />final inspection <br />FIGURE 11A-8K <br />RAMP AT SECONDARY EXTERIOR DOOR <br />1' <br />- <br />0 <br />" <br />MA <br />X <br />8'-0" MIN <br />secondary exterior <br />door <br />threshold <br />interior floor <br />level <br />permanently <br />installed ramp <br />exterior impervious <br />surface <br />FIGURE 32.1 <br />MANEUVERING CLEARANCE AT DWELLING UNIT DOORS <br />(b) <br />exception 1 <br />(a) <br />interior door or secondary exterior door <br />3'-0" MIN <br />DOOR AND <br />LANDING <br />WIDTH <br />3' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />3'-2" MIN <br />DOOR AND <br />LANDING <br />WIDTH <br />3' <br />- <br />3 <br />" <br /> <br />M <br />I <br />N <br />3' <br />- <br />3 <br />" <br /> <br />M <br />I <br />N <br />18" <br />MIN. <br />3'-0" MIN <br />DOOR WIDTH <br />3' <br />- <br />8 <br />" <br /> <br />M <br />I <br />N <br />18" <br />MIN. <br />18" <br />MIN. <br />dwelling unit interior side <br />exterior wall side <br />see 26 / A-3.30.1 <br />2'-8" CLEAR <br />OPENING <br />2'-8" CLEAR <br />OPENING <br />2'-10" CLEAR <br />OPENING <br />(c) <br />exception 2 <br />primary entry or required exit door <br />3'-0" MIN <br />DOOR AND <br />LANDING <br />WIDTH <br />2'-8" CLEAR <br />OPENING <br />3' <br />- <br />8 <br />" <br /> <br />M <br />I <br />N <br />3' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />in-swing door out-swing door <br />10 <br />" <br /> <br />M <br />I <br />N <br />34 <br />" <br /> <br />- <br /> <br /> <br />4 <br />4 <br />" <br />38 <br />" <br /> <br />- <br /> <br />4 <br />0 <br />" <br />44 <br />" <br /> <br />M <br />A <br />X <br />44 <br />" <br /> <br />M <br />A <br />X <br />60 <br />" <br /> <br />M <br />A <br />X <br />FIN FLR <br />smooth <br />door <br />bottom <br />bottom of door closer <br />push button * <br />view port <br />low **hardware <br />deadbolt <br />kick plate may occur 16 ga max, any <br />cavities created shall be capped <br />48 <br />" <br /> <br />M <br />A <br />X <br /> 4 <br />2 <br />" <br /> <br />P <br />R <br />E <br />F <br />E <br />R <br />E <br />D <br />78 <br />" <br /> <br />M <br />I <br />N <br />PR <br />E <br />F <br />E <br />R <br />R <br />E <br />D <br />*required at accessible/adaptable dwelling units <br />**if provided install two view ports; one high and one low at <br />accessible/adaptable dwelling units <br />view port <br />high ** <br />no projections into clear opening below 34"; <br />a maximim 4" projection is allowed above 34" <br />FIGURE 32.2 <br />TYPICAL LOCATION OF DOOR AND GATE ELEMENTS <br />1/ <br />2 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />F <br />L <br />O <br />O <br />R <br />LE <br />V <br />E <br />L <br /> <br />C <br />H <br />A <br />N <br />G <br />E <br />1/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br />VE <br />R <br />T <br />I <br />C <br />A <br />L <br />RI <br />S <br />E <br />floor level transition hardware <br />changes greater than 1/4" <br />shall be beveled 1:2 <br />door threshold hardware <br />changes greater than 1/4" <br />shall be beveled 1:2 <br />interior landing <br />(finish floor) <br />exterior landing <br />1/4":12" maximum slope <br />away from the door <br />1 <br />2 <br />TH <br />R <br />E <br />S <br />H <br />O <br />L <br />D <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />1/ <br />2 <br />" <br /> <br />M <br />A <br />X <br /> <br />A <br />T <br /> <br />P <br />R <br />I <br />M <br />A <br />R <br />Y <br /> <br />D <br />O <br />O <br />R <br />3/ <br />4 <br />" <br />M <br />A <br />X <br /> <br />A <br />T <br /> <br />S <br />E <br />C <br />O <br />N <br />D <br />A <br />R <br />Y <br /> <br />D <br />O <br />O <br />R <br />FIGURE 32.3 <br />FLOOR LEVEL CHANGE UP TO 1/2" AT THRESHOLD <br />primary or secondary <br />exterior door <br />CHAPTER 11A DIVISION IV - <br />CHAPTER 11A HOUSING ACCESSIBILITY <br />DIVISION IV DWELLING UNIT FEATURES <br />DIVISION IV TABLE OF CONTENTS <br />SECTION 1128A COVERED DWELLING UNITS (see detail XX this sheet) <br />SECTION 1129A RESERVED <br />SECTION 1130A ACCESSIBLE ROUTE WITHIN COVERED MULTIFAMILY DWELLING UNITS (see detail XX this sheet) <br />SECTION 1131A CHANGES IN LEVEL ON ACCESSIBLE ROUTES (see detail XX this sheet) <br />SECTION 1132A DOORS (see detail XX this sheet) <br />SECTION 1133A KITCHENS (see detail XX this sheet) <br />SECTION 1134A BATHING AND TOILET FACILITIES (see detail XX this sheet) <br />SECTION 1135A LAUNDRY ROOMS (see detail XX this sheet) <br />SECTION 1136A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS (see detail XX this sheet) <br />2 <br />1 <br />3 <br />4 <br />5 <br />68 <br />7