Laserfiche WebLink
(CONTINUED) <br />DIVISION 7 - <br />G E N E R A L C O N S T R U C T I O N R E Q U I R E M E N T S <br />32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG <br />WOOD AND PLASTICDIVISION 6 - <br />(CONTINUED) <br />THERMAL AND MOISTURE PROTECTIONDIVISION 7 - <br />WOOD AND PLASTIC <br />(CONTINUED) <br />DIVISION 6 - THERMAL AND MOISTURE PROTECTIONTHERMAL AND MOISTURE PROTECTION <br />(C O N T I N U E D) <br />(CONTINUED) <br />DIVISION 7 - <br />GCR-2 <br />GENERAL <br />CONSTRUCTION <br />REQUIREMENTS <br />PLYWOOD AND PARTICLE BOARD SHELVES SHALL BE HARDWOOD EDGE BANDED ON ALL <br />USE CONCEALED FASTENINGS WHERE POSSIBLE. <br />MITERED, BUTTED, OR COPED, WITH NAILS SET AND SURFACES FREE OF TOOLMARKS. <br />ALL JOINTS SHALL BE TIGHT AND TRUE AND SECURELY FASTENED. CORNERS SHALL BE <br />ALL CABINETS WORK SCHEDULED FOR PAINT OR STAIN FINISH SHALL BE SMOOTHLY DRESSED <br />BUMPING, SCRAPING, DENTING, ETC. PROVIDE TYPE II-HIGH DENSITY FOAM AT ALL TRIM <br />PROVIDE REINFORCED FINISH AS REQUIRED AT HUMAN TRAFFIC LOCATIONS SUBJECTED TO <br />PROVIDE MOLDED SHAPES TO RECEIVE EXTERIOR FINISH AS INDICATED IN THE CONSTRUCTION <br />DOCUMENTS. EXPANDED POLYSTYRENE SHALL BE BY "VEFO INCORPORATED"; MOLDED POLY- <br />URETHANE FOAM SHALL BE BY "NESCO MANUFACTURING, INC."; MOLDED HIGH DENSITY POLY- <br />MER SHALL BE BY "FYPON MOLDED MILLWORK"; OR APPROVED CLIENT SELECTED SUBSTITUTE. <br />STRUCTURAL STRENGTH FOR LOCATION USED. <br />PRODUCT SHALL BE COMPATIBLE WITH EXTERIOR USE, ADJACENT FINISHES AND OF SUFFICIENT <br />BACKING/SUPPORT, JOINT REINFORCING, SURFACE PREPARATION, AND ADHESIVE/ATTACHMENT. <br />INSTALLATION AND FINISH APPLICABLE PER MANUFACTURER'S RECOMMENDATIONS, INCLUDING <br />FURNISH AND INSTALL ALL MOLDED MILLWORK COMPLETE. <br />MOLDED/FORMED MILLWORK <br />COUNTER TOPS AND BACKSPLASHES SHALL BE AS NOTED IN THE CONSTRUCTION DOCUMENTS. <br />CABINETRY HARDWARE SHALL BE SELECTED BY CLIENT. <br />MATERIALS AND DESIGN OF CABINETRY SHALL BE SELECTED BY CLIENT. <br />CABINETS SCHEDULED FOR PAINT FINISHES SHALL BE PRIMED AND BACK-PAINTED PRIOR TO <br />INSTALL ALL WORK LEVEL, PLUMB, AND TRUE. SCRIBE MEMBERS ACCURATELY IN PLACE TO <br />THE "NATIONAL KITCHEN CABINET ASSOCIATION" (NKCA). <br />ALL WORK AND MATERIALS SHALL MEET THE LATEST EDITION PERFORMANCE STANDARDS OF <br />AND FIXTURE SIZES WITH CLIENT AND PRODUCT MANUFACTURER PRIOR TO FABRICATION AND <br />FIELD MEASUREMENTS PRIOR TO FABRICATION AND INSTALLATION. VERIFY ALL APPLIANCE <br />FURNISH AND INSTALL ALL CABINET WORK COMPLETE. VERIFY ALL DIMENSIONS BY TAKING <br />SOLID WOOD. IN LIEU OF WOOD, METAL ROD AND SHELF SYSTEM MAY BE SELECTED BY CLIENT. <br />ALL SHELVING SHALL BE PARTICLE BOARD, EDGE-BANDED OR 1 x CLEAR PINE, UNLESS NOTED <br />OTHERWISE. SHELF DEPTH SHALL BE 15 INCHES AT WARDROBE CLOSETS, AND PER PLAN AT <br />ALL OTHER LOCATIONS. SHELF ROD AT WARDROBE CLOSETS SHALL BE 1 3/8-INCH DIAMETER, <br />VERTICAL AND HORIZONTAL TRIM MEMBERS, SHALL BE IN LONGEST PRACTICAL LENGTHS. <br />APPLICATIONS. <br />6.3.6 COUNTER TOPS <br />MATERIALS <br />INSTALLATION <br />GENERAL <br />6.4.2 <br />6.4.3 <br />6.4.1 <br />6.4 <br />EXPOSED EDGES. <br />HARDWARE <br />MATERIALS AND DESIGN <br />FIT ADJOINING SURFACES. <br />INSTALLATION. <br />6.3.5 <br />6.3.4 <br />6.3.2 STANDARDS <br />WORKMANSHIP <br />AND SANDED. <br />6.3.3 <br />INSTALLATION. <br />GENERAL <br />CABINETRY6.3 <br />6.3.1 <br />DRAFT STOPPING MATERIALS SHALL NOT BE LESS THAN 1/2 INCH GYPSUM BOARD, 3/8 INCH <br />WOOD STRUCTURAL PANEL, 3/8 INCH TYPE 2-M PARTICLEBOARD OR OTHER APPROVED <br />MATERIALS ADEQUATELY SUPPORTED. <br />MATIC LATCHES CONSTRUCTED AS REQUIRED FOR THE PARTITIONS. <br />OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTO- <br />PROVIDE SOLID 2 X 4 BACKING AT 24" O.C. AS REQUIRED FOR GYPSUM BOARD NIALING <br />ALONG THE CEILING AT THE TRANSITION OF CEILING AND WALL. <br />FULL LENGTH CONTINUOS BOARDS SHALL BE USED WHEREVER APPLICABLE OR SPECIFICALLY <br />SIZE AND PROFILE OF ALL DOOR CASING, WALL BASEBOARD, CEILING CROWN-MOULDING, <br />CHAIR RAIL, AND WINDOW STOOL AND APRON, SHALL BE AS SELECTED BY CLIENT. ALL <br />DOORS SHALL OPERATE FREELY, BUT NOT LOOSELY, WITHOUT STICKING OR BINDING, WITHOUT <br />HINGE BOUND CONDITIONS; AND WITH ALL HARDWARE PROPERLY ADJUSTED AND FUNCTIONING. <br />LOCK STILE EDGES SHALL BE BEVELED. <br />SCHEDULED, INCLUDING CARPETING, ALLOW 1/2" SPACE FOR RETURN AIR. <br />INCH. CLEARANCE AT THE BOTTOM SHALL BE ADJUSTED FOR FINISH FLOOR COVERING <br />CLEARANCE AT THE LOCK AND HANGING STILES, AND AT THE TOP, SHALL NOT EXCEED 1/8 <br />EACH DOOR SHALL BE ACCURATELY CUT, TRIMMED, AND FITTED TO ITS' RESPECTIVE FRAME <br />AND HARDWARE WITH DUE ALLOWANCE FOR PAINTER'S FINISHES. <br />DOOR FRAMES SHALL BE SET PLUMB AND TRUE, RIGIDLY SECURED, AND PROTECTED DURING <br />AND COMPLETELY PREPARED FOR FINISH. <br />ALL WORK SHALL BE MACHINED OR HAND-SANDED, SHARP EDGES AND SPLINTERS REMOVED, <br />WOODWORK SHALL BE ACCURATELY SCRIBED TO FIT ADJOINING SURFACING. <br />NEATLY MITERED, BUTTED, OR COPED, WITH NAILS SET AND SURFACES FREE OF TOOL MARKS. <br />ALL JOINTS SHALL BE TIGHT AND TRUE, AND SECURELY FASTENED. CORNERS SHALL BE <br />FURNISH AND INSTALL ALL FINISH CARPENTRY COMPLETE, INCLUDING TRIM, DOOR FRAMES, <br />TO RE-DIRECT CHANNELED OR RUN-OFF WATER, AWAY FROM VERTICAL SURFACES. <br />PROVIDE CRICKETS AS INDICATED AND AS NECESSARY FOR PROPER WATER DRAINAGE AND <br />ENSURE WATER DRAINAGE WITHOUT PUDDLING 1/8"/FT. <br />ALL BUILT-UP ROOFS, WATERPROOF BALCONY DECKS, AND EXTERIOR HORIZONTAL AREAS <br />(I.E., POTSHELFS, LOW WALLS, CHIMNEY SHOULDERS, ETC.) ARE TO BE FRAMED WITH SLOPE TO <br />PROVIDE AN 18 INCH HIGH PLATFORM WITH 3/4 INCH PLYWOOD FLOOR, AT ALL WATER <br />ALL FASCIAS AND BARGE BOARDS SHALL BE MITERED AT THE JOINTS, AND SHALL NOT BE <br />SPLICED OVER ANY DOORWAY, ENTRY COURT, OR DECK. <br />PLUMBING, FINISH HARDWARE, FIREWALLS, TOWEL BARS, PAPER HOLDERS, ETC. <br />FIXTURES, CABINETS, GYPSUM BOARD, STAIR RAILING, STUCCO, TUB AND SHOWER ENCLOSURES, <br />PROVIDE SOLID 2X BACKING REQUIRED FOR PENDANT AND SURFACE-MOUNTED ELECTRICAL <br />MATERIALS6.2.4 <br />DOOR INSTALLATION <br />THE COURSE OF CONSTRUCTION. <br />6.2.3 <br />NOTED. <br />WORKMANSHIP <br />GENERAL <br />PANELING, AND SHELVING. <br />FINISH CARPENTRY <br />6.2.1 <br />6.2.2 <br />6.2 <br />HEATERS LOCATED IN GARAGES. <br />MISCELLANEOUS FRAMING6.1.5 <br />THE MOUNTING OF HANDRAILS SHALL BE SUCH THAT THE COMPLETED HANDRAIL AND SUPPORT- <br />ING STRUCTURE ARE CAPABLE OF WITHSTANDING A LOAD OF AT LEAST 200 POUNDS (890 N) <br />APPLIED IN ANY DIRECTION AT ANY POINT ON THE RAIL. THESE LOADS SHALL NOT BE ASSUMED <br />TO ACT CUMULATIVELY WITH THOSE OF 6.5.2. <br />RAILS. REACTIONS DUE TO THIS LOADING NEED NOT BE COMBINED WITH THOSE OF IMPACT <br />RIGHT ANGLES OVER THE ENTIRE TRIBUTARY AREA, INCLUDING OPENINGS AND SPACES BETWEEN <br />BALCONY RAILINGS AND GUARDRAILS <br />STANDING A LOAD OF 25 POUNDS PER SQUARE FOOT (1.2 kN/m ) APPLIED HORIZONTALLY AT <br />INTERMEDIATE RAILS, PANEL FILLERS AND THEIR CONNECTIONS SHALL BE CAPABLE OF WITH- <br />PATTERN SUCH THAT A SPHERE 4" DIAMETER CANNOT PASS THRU. <br />OPEN GUARDRAILS/HANDRAILS SHALL HAVE INTERMEDIATE RAILS OR AN ORNAMENTAL <br />DRAFT STOPS SHALL BE INSTALLED IN ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET <br />OUT FROM WALLS AND SIMILAR CONCEALED SPACES OF BUILDINGS HAVING USES OTHER THAN <br />DWELLINGS OR HOTELS SO THAT THE AREA BETWEEN DRAFT STOPS DOES NOT EXCEED <br />3,000 SQUARE FEET AND THE GREATEST HORIZONTAL DIMENSION DOES NOT EXCEED 60 FT. <br />HORIZONTAL DIMENSION BETWEEN STOPS DOES NOT EXCEED 60 FEET. <br />OF BUILDINGS USED FOR OTHER THAN DWELLING OR HOTEL OCCUPANCIES SO THAT THE AREA <br />DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF BUILDINGS OR PORTIONS <br />OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET AND SO THAT THE <br />4. OTHER USES. <br />3. OTHER USES. <br />INCREASES, SUCH AS CRANES. <br />HANDRAILS6.5.3 <br />6.5.2 <br />GENERAL <br />GUARDRAILS/ HANDRAILS <br />6.5.1 <br />6.5 <br />SHALL COMPLY WITH MANDATORY INFILTRATION STANDARDS AND SHALL BE IN CONFORMANCE <br />AND SHALL MEET OR EXCEED A DESIGN WIND PRESSURE OF 20 P.S.F.. ALL EXTERIOR DOORS <br />ALL DOORS SHALL BE INSTALLED PER MANUFACTURER'S INSTALLATION RECOMMENDATIONS, <br />DIVISION 8 - <br />8.1 DOORS <br />WITH ACOUSTICAL REQUIREMENTS (IF APPLICABLE) AS INDICATED IN THE ACOUSTICAL <br />REPORT. DOORS SHALL COMPLY WITH ALL APPLICABLE SECURITY ORDINANCES. <br />INSTALLATION8.1.2 <br />HAVE PANELS A MINIMUM DENSITY OF FIVE (5) OUNCES PER SQUARE FOOT. ALL FRONT <br />TYPE AND SIZE (MINIMUM REQUIREMENTS) <br />1. <br />MUM THICKNESS OF 1 3/4 INCH, AND WITH PANELS OF NOT LESS THAN 9/16 INCH THICKNESS. <br />METAL DOORS SHALL BE A MINIMUM THICKNESS OF .0215 INCHES, AND RIVETED TOGETHER <br />WIDTH HORIZONTAL BEAM ATTACHED TO THE MAIN DOOR STRUCTURE. WHICH SHALL MEET <br />THE PILOT, OR PEDESTRIAN ACCESS DOOR FRAMING WITHIN THREE (3) INCHES OF THE <br />8.1.3 <br />AT 18 INCHES ON CENTER (MAX.) ALONG THE OUTSIDE SEAMS. THERE SHALL BE A FULL <br />STRIKE AREA OF THE PILOT OR PEDESTRIAN ACCESS DOOR. FIBERGLASS DOORS SHALL <br />(EXCEPTION: CLEAR VISION PANEL SUCH AS DOOR WINDOW LITES OR "SPEAKEASY" DOOR.) <br />ENTRY DOORS SHALL BE EQUIPPED WITH A WIDE ANGLE (180 DEGREE) DOOR VIEWER. <br />HARDBOARD PANEL AND/OR MIRROR DESIGN (IF APPLICABLE) SHALL BE SELECTED BY <br />CLIENT. LOUVERED DOORS SHALL MATCH TYPICAL INTERIOR DOORS IN SIZE AND MATE- <br />INTERIOR DOORS - SWINGING AND SLIDING POCKET DOORS SHALL BE OF HOLLOW CORE <br />CONSTRUCTION (UNLESS SPECIFIED OTHERWISE) WITH A MINIMUM THICKNESS OF 1 3/8 INCH. <br />DOORS AND WINDOWS <br />STANDARDS8.1.1 <br />EXTERIOR DOORS - WOOD DOORS SHALL BE OF SOLID CORE CONSTRUCTION WITH A MINI- <br />2. <br />RIAL, AND IN CASE OF THOSE REQUIRED FOR MAKE UP AIR AT CLOTHES DRYER LOCATIONS <br />(PER C.M.C., SECTION 504.3.2) THE LOUVERED PORTION SHALL PROVIDE A MINIMUM 100 SQ. IN. <br />NET OPENING. WATER HEATER AND F.A.U. CLOSET DOORS SHALL BE WEATHER-STRIPPED <br />AND/OR METAL CONSTRUCTION, AND SHALL BE INSTALLED WITH THRESHOLD (SILL) PANS. <br />CONDITIONED SPACES. BY-PASS SLIDING DOORS (WARDROBE TYPE) MAY BE OF VINYL <br />IN AN EFFORT TO SEPARATE UNCONDITIONED SPACE RECEIVING COMBUSTION AIR FROM <br />HARD BOARD PANEL AND/OR MIRROR DESIGN (IF APPLICABLE) SHALL BE SELECTED BY <br />CLIENT. <br />DOOR(S) LEADING FROM GARAGE AREA INTO PRIVATE DWELLING UNIT - DOORS SHALL BE <br />OF SOLID CORE CONSTRUCTION WITH A MINIMUM THICKNESS OF 1 3/4 INCH. (EXCEPTION: <br />20 MINUTE FIRE-RATED DOOR). DOORS SHALL BE TIGHT-FITTING, AND PROVIDED WITH <br />A SELF-CLOSING MECHANISM. <br />UTILITY METER ENCLOSURE DOORS - DOORS SHALL BE VENTED AS REQUIRED BY UTILITY <br />COMPANY. PROVIDE "VEIW PLATE(S)" TO USAGE READ-OUTS IF REQUIRED BY UTILITY <br />COMPANY. <br />ROLLING OVERHEAD, SOLID OVERHEAD, SWING, SLIDING, OR ACCORDION, GARAGE TYPE <br />DOORS - WOOD DOORS SHALL HAVE PANELS A MINIMUM OF 5/16 INCH IN THICKNESS, WITH <br />THE LOCKING HARDWARE BEING ATTACHED TO THE SUPPORT FRAMING. METAL DOORS <br />SHALL BE A MINIMUM THICKNESS OF .0215 INCHES, AND RIVETED TOGETHER AT 18 INCHES <br />ON CENTER (MAX.) ALONG THE OUTSIDE SEAMS. THERE SHALL BE A FULL WIDTH HORIZ- <br />ONTAL BEAM ATTACHED TO THE MAIN DOOR STRUCTURE WHICH SHALL MEET THE PILOT, OR <br />PEDESTRIAN ACCESS DOOR FRAMING WITHIN THREE (3) INCHES OF STRIKE AREA OF THE <br />PILOT OR PEDESTRIAN ACCESS DOOR. FIBERGLASS DOORS SHALL HAVE PANELS A <br />MINIMUM DENSITY OF FIVE (5) OUNCES PER SQUARE FOOT. <br />ALL WINDOWS SHALL BE INSTALLED PER MANUFACTURER'S INSTALLATION RECOMMENDATIONS, <br />4. <br />5. <br />6. <br />AND SHALL MEET OR EXCEED A DESIGN WIND PRESSURE OF 20 P.S.F.. ALL WINDOWS SHALL <br />COMPLY WITH MANDATORY INFILTRATION STANDARDS, AND SHALL BE IN CONFORMANCE <br />WITH ACOUSTICAL REQUIREMENTS (IF APPLICABLE) AS INDICATED IN THE ACOUSTICAL <br />REPORT. WINDOWS SHALL COMPLY WITH ALL APPLICABLE SECURITY REQUIREMENTS. IN <br />REGARDS TO WOOD WINDOWS, ALL WORK AND MATERIALS SHALL MEET THE LATEST EDITION <br />PERFORMANCE STANDARDS OF THE "NATIONAL WOOD WINDOW AND DOOR ASSOCIA- <br />8.2 <br />8.2.1 <br />WINDOWS <br />STANDARDS <br />TION", (N.W.W.D.A.). <br />8.2.2 INSTALLATION <br />INSULATION7.1 <br />THERMAL INSULATION <br />INSTALL INSULATION BATTS BETWEEN JOISTS, AT ALL CEILING AREAS EXPOSED TO ROOF OR <br />ATTIC AREAS INCLUDING ANY VERTICAL WALL AREAS SEPARATING CONDITIONED SPACES FROM <br />ATTICS BETWEEN CEILINGS AND ROOF, AND BETWEEN STUDS AT ALL EXTERIOR WALLS <br />7.1.1 <br />NESS. PROVIDE INSULATION STOPS/BAFFLES AS REQUIRED TO PREVENT OBSTRUCTION OF <br />SECURELY INSTALLED AND TIGHTLY FITTED WITHOUT COMPRESSING THE NORMAL LOFT THICK- <br />(INCLUDING WALL(S) BETWEEN CONDITIONED SPACES AND UNCONDITIONED SPACES. BATTS SHALL BE <br />VENTS. <br />PROVIDE AND INSTALL ALL THERMAL INSULATION PER THE REQUIREMENTS SET FORTH IN <br />"TITLE 24" OF THE CALIFORNIA ADMINISTRATIVE CODE". REFER TO TITLE 24 ENERGY <br />COMPLIANCE SHEETS AND CALCULATIONS (PREPARED BY, TITLE 24 ENERGY CONSULTANT), <br />FOR SPECIFIC REQUIREMENTS. <br />INSTALLATION COMPLIES WITH THE STANDARDS ESTABLISHED BY THE STATE OF CALIFORNIA. <br />WITHIN THE STRUCTURE, A CERTIFICATION OF COMPLIANCE CERTIFYING THAT THE INSULATION <br />CONTRACTOR (INSULATION INSTALLER) SHALL SIGN AND POST IN A CONSPICUOUS LOCATION <br />INSTALL INSULATION BATTS BETWEEN STUDS AND JOISTS, SECURELY AND TIGHTLY FITTED <br />SOUND TRANSMISSION CONTROL INSULATION <br />WITHOUT COMPRESSING THE NORMAL LOFT THICKNESS, PER THE CONSTRUCTION DOCUMENTS. <br />ALL OPENINGS IN PARTY WALLS AS DETAILED IN THE CONSTRUCTION DOCUMENTS, SUCH AS <br />7.1.2 <br />MEDICINE CABINETS, ELECTRICAL OR PHONE OUTLETS, ETC., SHALL HAVE A MINIMUM OF TWO <br />LAYERS OF INSULATION BATTS LAPPING THE OPENING A DISTANCE OF 14 INCHES (MINIMUM). <br />PROVIDE BATT INSULATION AT ALL STUD AND JOIST CAVITIES WHICH CONTAIN PLUMBING <br />WASTE LINES. <br />STANDARDS <br />ROOFING, DECKING, AND WATERPROOFING7.2 <br />7.2.1 <br />ASSOCIATION" (ARMA). <br />CONTRACTORS ASSOCIATION" (NRCA) AND "ASPHALT ROOFING MANUFACTURERS <br />THE "NATIONAL ROOFING CONTRACTORS ASSOCIATION" (NRCA) AND "ASPHALT ROOFING <br />ALL WORK AND MATERIALS SHALL MEET THE LATEST EDITION PERFORMANCE STANDARDS OF <br />INSTALLATION7.2.2 <br />HIGH WIND AREAS, AND PER THE REQUIREMENTS SET FORTH IN THE CALIFORNIA BUILDING CODE <br />URER'S RECOMMENDATIONS, INCLUDING THE USE OF FASTENERS AND ANCHORING DEVICES IN <br />INSTALL ALL ROOFING AND WALL CORROSION RESISTANT METAL FLASHING PER MANUFACT- <br />(CURRENT EDITION) CHAPTER 15, CAREFULLY INCORPORATING FLASHING, SCUPPERS, JACKS, <br />SLEEVES, ROOF DRAINS, SKYLIGHTS, ETC. <br />PROVIDE CANT STRIPS AT ALL VERTICAL SURFACES. <br />PROVIDE CRICKETS AS INDICATED, AND AS NECESSARY FOR PROPER WATER DRAINAGE, AND <br />TO RE-DIRECT CHANNELED OR RUN-OFF WATER AWAY FROM VERTICAL SURFACES. <br />CLIENT SHALL PROVIDE A WATERPROOFING SPECIALIST TO REVIEW BUILT-UP ROOFING, <br />INSPECTION7.2.3 <br />FOUNDATION WALL WATERPROOFING, WATERPROOF DECKING, AND FLASHING DETAILS, AND <br />PROVIDE CONTINUOS INSPECTION DURING FIELD INSTALLATION OF ALL WATERPROOF AND <br />FLASHING SURFACES AND MATERIALS TO INSURE ADHERENCE TO MANUFACTURER'S SPECI- <br />FICATIONS AND THE HIGHEST STANDARDS OF CONSTRUCTION PRACTICE. <br />ROOF PITCH, INSTALL TILE OVER UNDERLAYMENT OF MINIMUM ONE LAYER TYPE 30 FELT. <br />MATERIALS <br />ROOFING TILES (CLAY OR CONCRETE) - CLASS "A" RATED ROOF ASSEMBLY. MINIMUM 3:12 <br />7.2.4 <br />(TYPE 40 FOR PITCHES LOWER THAN 4:12), SIDE LAPPED 2 INCHES AND END LAPPED 6 INCHES, <br />OR PER MANUFACTURER'S SPECIFICATIONS. TILE WEIGHT SHALL BE APPROXIMATELY 9.5 LBS. <br />PER SQ. FT. (TO BE VERIFIED), AND PROFILE, STYLE, COLOR, TEXTURE, AND PATTERN, SHALL <br />BE AS SELECTED BY ARCHITECT. REFER TO "COLOR AND MATERIAL SCHEDULE" <br />PREPARED BY ARCHITECT. <br />PITCH. INSTALL SHINGLES OVER UNDERLAYMENT OF MINIMUM ONE LAYER OF NON-PERFO- <br />COMPOSITION (ASPHALT) SHINGLES - CLASS "A" RATED ROOF ASSEMBLY MINIMUM 4:12 ROOF <br />RATED TYPE 15 FELT LAPPED 2 INCHES HORIZONTALLY AND 4 INCHES VERTICALLY TO SHED <br />WATER OR PER MANUFACTURER'S SPECIFICATIONS. COMPOSITION SHINGLES MAY BE IN- <br />STALLED ON SLOPES AS LOW AS 2:12 ROOF PITCH, PROVIDED THAT PITCHES LOWER THAN <br />4:12, THE SHINGLES ARE APPROVED SELF-SEALING OR ARE HAND SEALED AND ARE IN- <br />STALLED WITH AN UNDERLAYMENT CONSISTING OF A MINIMUM OF TWO LAYERS OF NON-PERFO- <br />RATED TYPE 15 FELT APPLIED SHINGLE FASHION, OR PER MANUFACTURER'S SPECIFICATIONS. <br />SHINGLE COLOR, TEXTURE, AND PATTERN, SHALL BE AS SELECTED BY ARCHITECT. REFER TO <br />"COLOR AND MATERIAL SCHEDULE" PREPARED BY ARCHITECT. <br />SELECTED BY ARCHITECT. REFER TO "COLOR AND MATERIALS SCHEDULE" PREPARED BY <br />BLOCKED ROOF 1/4 INCH PER FOOT (MINIMUM) FOR WATER DRAINAGE. COLOR SHALL BE AS <br />FLOOD COAT WITH 400 POUNDS PEA GRAVEL SURFACING MATERIAL. SLOPE SOLID EDGE <br />BUILT-UP ROOFING - CLASS "A" RATED ROOF ASSEMBLY. ASSEMBLY SHALL INCLUDE 4 LAY- <br />ERS OF TYPE 15 FELT WITH 25 POUNDS HOT-MOPPING BETWEEN LAYERS AND 60 POUNDS <br />METAL ROOF - CLASS "A" RATED ROOF ASSEMBLY. ASSEMBLY SHALL BE SEAMLESS OR <br />"STANDING SEAM", PRE-PAINTED, AND CORROSION RESISTANT. INSTALL METAL ROOFING <br />OVER UNDERLAYMENT OF MINIMUM ONE LAYER TYPE 15 FELT, IN ACCORDANCE WITH MANUFAC- <br />TURER'S SPECIFICATIONS. SLOPE METAL A MINIMUM OF 1 INCH PER FOOT, OR AS INDICATED <br />IN THE CONSTRUCTION DOCUMENTS. COLOR SHALL BE AS SELECTED BY ARCHITECT. REFER <br />TO "COLOR AND MATERIALS SCHEDULE" PREPARED BY ARCHITECT. <br />WHERE INDICATED IN THE CONSTRUCTION DOCUMENTS. WATERPROOFING SYSTEM SHALL BE <br />FOUNDATION WALL WATERPROOFING - APPLY ALL WATERPROOFING SYSTEMS COMPLETE, <br />I.C.B.O. APPROVED. PROTECT WATERPROOFING MATERIALS DURING BACK FILLING OPERA- <br />TIONS WITH A NON-DETERIORATING PROTECTION BOARD. <br />GENERAL <br />FLASHING AND SHEET METAL <br />7.3.1 <br />7.3 <br />PROVIDE MISCELLANEOUS CORROSION RESISTANT METAL WORK AS INDICATED IN THE <br />CONSTRUCTION DOCUMENTS, INCLUDING FLASHING, GRAVEL STOPS, DRIP EDGES, SILL PANS, <br />SCUPPERS, GUTTERS, DOWNSPOUTS, CHIMNEY SHROUDS, LAUNDRY CHUTES, AND MISCELLANEOUS <br />VENTS. <br />7.3.2 <br />METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION, INC." (SMACNA). <br />ALL WORK AND MATERIALS SHALL MEET THE LATEST EDITION PERFORMANCE STANDARDS <br />RECOMMENDED IN THE "ARCHITECTURAL SHEET METAL MANUAL", PUBLISHED BY THE "SHEET <br />STANDARDS <br />WORKMANSHIP7.3.3 <br />MATERIALS7.3.4 <br />COUNTERFLASHING SHALL BE INSTALLED AT ALL LOCATIONS WHERE MATERIALS ON <br />FLASHING <br />PROVIDE FLASHING AND COUNTERFLASHING AT ALL EXTERIOR OPENINGS EXPOSED TO <br />WEATHER, IN SUCH A MANNER AS TO MAKE THE OPENINGS WEATHERPROOF. FLASHING AND <br />7.3.5 <br />DIFFERENT PLANES INTERSECT. LOCATIONS INCLUDE, ROOF TO WALL, ROOF TO ROOF, ROOF <br />TO SKYLIGHT, DECK TO WALL, AND OTHER LOCATIONS RECOMMENDED IN "THE ARCHITECTURAL <br />SHEET METAL MANUALS". <br />WITH INSTALLATION USING APPROVED METHOD AND MATERIALS, ALL FLASHING JOINTS <br />ALL FLASHING SHALL CONFORM TO THE STANDARDS OF LOCAL AND APPLICABLE CODES, <br />AND PENETRATIONS SHALL BE CAULKED AND SEALED. <br />FLASHING AND CAULKING SHALL BE PROVIDED AT ALL WOOD BEAMS, BRACES, AND OUT- <br />LOOKERS WHICH PROJECT THROUGH EXTERIOR WALLS OR ROOF SURFACES. <br />THE EXTERIOR FINISH MATERIAL. <br />FLASHING SHALL BE PROVIDED AT ALL NON-VERTICAL WOOD TRIM SURFACES ABUTTING TO <br />FLASHING SHALL BE PROVIDED AT ALL WINDOW , DOOR, AND WALL VENT OPENINGS. FLASHING <br />SHALL BE "MOISTOP" FLASHING SYSTEM BY "FORTIFIBER CORPORATION", OR APPROVED <br />EQUAL. INSTALLATION PER MANUFACTURER'S RECOMMENDATIONS. FLASHING SHALL BE <br />CAULKED WITH MATERIALS APPLIED AND TESTED BY THE FLASHING MANUFACTURER. <br />TURNED INWARD APPROXIMATELY 1/2 INCH AT 30-DEGREE ANGLES. SUCCEEDING VALLEY <br />WITH A 1 INCH HIGH SPLASH DIVERTER IN THE CENTER AND BOTH LONGITUDINAL EDGES <br />26 GAUGE), 18 INCH WIDE AT COMPOSITION SHINGLES AND 24 INCH WIDE AT ROOFING TILE, <br />ROOF VALLEY FLASHING SHALL BE CORROSION RESISTANT (GALVANIZED) METAL (MINIMUM <br />METAL SECTIONS SHALL OVERLAP A MINIMUM OF 4 INCHES, AND BE ATTACHED WITH CLIPS <br />OR NAILS BENT OVER THE EDGES - NOT PENETRATING THE METAL. <br />OR ROOF FRAMING AS REQUIRED. ALL FLASHINGS FOR THROUGH ROOF PENETRATIONS SHALL <br />OPENINGS THROUGH ROOFING MATERIAL FOR VENTS, ELECTRICAL SERVICE CONNECTIONS, <br />ETC., SHALL BE ADEQUATELY WEATHERPROOFED AND SUPPORTED BY ADDITIONAL BLOCKING <br />BE OF APPROVED MATERIALS, AND IN THE CASE OF ROOFING TILES, SHALL BE FORMED TO <br />THE CONTOURS OF THE TILE, AND SHALL NOT BE LESS THAN 16 INCHES FROM THE CENTER OF <br />ANY VALLEY. <br />SILICONE-TREATED RELEASE PAPER, ONLY TO BE REMOVED IMMEDIATELY BEFORE INSTALL- <br />WHICH ENABLES IT TO SEAL AROUND NAILS OR FASTENERS, AND SHALL BE PROTECTED BY A <br />ASPHALT. THE RUBBERIZED ASPHALT LAYER SHALL HAVE STRONG ADHESIVE PROPERTIES <br />AND BENEATH COPINGS. PROVIDE TOUGH, FLEXIBLE, SELF-HEALING, SELF-SEALING, SELF- <br />FLASHING/UNDERLAYMENT SHALL BE PROVIDED AT ALL NON-VERTICAL STUCCO SURFACES <br />ADHERING, WATER BARRIER MEMBRANE COMPOSITE OF POLYETHYLENE FILM AND RUBBERIZED <br />ATION. PRODUCT SHALL BE "GRACE ICE AND WATER SHIELD" BY "W.R. GRACE & CO.", OR <br />EQUAL, AND SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. <br />ARCHITECT. <br />7.4 <br />7.4.1 <br />AN ATTIC ACCESS OPENING SHALL BE PROVIDED TO ALL ATTICS OF BUILDINGS WITH COMBUS- <br />TIBLE CEILING OR ROOF CONSTRUCTION. <br />EXCEPTION: <br />ATTIC VENTILATION <br />ACCESS <br />ACCESS OPENING. <br />UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT OR ABOVE THE <br />IN A CORRIDOR, HALLWAY, OR OTHER READILY ACCESSIBLE LOCATION. THIRTY-INCH-MINIMUM <br />ATTICS WITH A MAXIMUM VERTICAL HEIGHT OF LESS THAN 30 INCHES. <br />THE OPENING SHALL NOT BE LESS THAN 22 INCHES BY 30 INCHES AND SHALL BE LOCATED <br />7.4.2 VENTILATION <br />ALL JOINTS AND PENETRATIONS AROUND DOOR FRAMES SHALL BE CAULKED AND SEALED (NON- HARDENING) <br />PER STATE ENERGY REQUIREMENTS. LAPPING AND SEALING OF NAILING FINS TO FLASHING MATERIAL AND <br />LAPPING TO BUILDING PAPER, SHALL BE IN ACCORDANCE WITH CODE MINIMUMS AND MANUFACTURER'S <br />RECOMMENDATIONS. ALIGN BOTTOM OF HEADERS AT ALL ADJACENT WINDOWS AND DOORS, UNLESS NOTED <br />OTHERWISE. <br />ALL DOORS SHALL BE ACCURATELY CUT, TRIMMED, AND FITTED TO ITS' RESPECTIVE FRAME AND HARDWARE, <br />WITH DUE ALLOWANCE FOR PAINTER'S FINISHES. CLEARANCE DIMENSION AT THE LOCK AND HANGING STILES, <br />AND AT THE TOP SHALL NOT EXCEED 1/8 INCH. CLEARANCE DIMENSION AT THE BOTTOM SHALL BE ADJUSTED TO <br />ACCOMMODATE THE SPECIFIC FINISHED FLOOR COVERING, INCLUDING CARPET, PLUS 1/2" FOR RETURN AIR <br />PASSAGE. LOCK STILE EDGES SHALL BE BEVELED, AND ALL DOOR STOPS SHALL BE PROVIDED BEHIND ALL <br />SWINGING DOORS. <br />ALL JOINTS AND PENETRATIONS AROUND WINDOW FRAMES SHALL BE CAULKED AND SEALED (NON- <br />HARDENING) PER STATE ENERGY REQUIREMENTS. LAPPING AND SEALING OF NAILING FINS TO FLASHING <br />MATERIAL AND LAPPING TO BUILDING PAPER, SHALL BE IN ACCORDANCE WITH CODE MINIMUMS AND <br />MANUFACTURER'S RECOMMENDATIONS. ALIGN BOTTOM OF HEADERS AT ALL ADJACENT WINDOWS AND DOORS, <br />UNLESS NOTED OTHERWISE. <br />ALL SHEET METAL SHALL BE CORROSION RESISTANT, COMMERCIAL GRADE, PAINTABLE, ZINC-COATED <br />(GALVANIZED) METAL, AND SHALL HAVE A MINIMUM THICKNESS OF 0.019 INCH (NO. 26 GALVANIZED SHEET <br />METAL GAUGE). SHEET METAL THICKNESS SHALL BE APPROP- IATE FOR THE SPECIFIC CONDITION IN <br />ACCORDANCE WITH THE RECOMMENDATIONS OF THE "ARCHITECTURAL SHEET METAL MANUAL", BUT IN NO <br />CASE SHALL THE THICKNESS BE LESS THAN THE LISTED MINIMUM OR PER REQUIREMENTS SET FORTH IN <br />THE CALIFORNIA BUILDING CODE (CURRENT EDITION). <br />ALL SHEET METAL FASTENERS (SCREWS, ETC.) SHALL BE OF CORROSION RESISTANT (GALVA- NIZED) METAL. <br />SOLDER SHALL BE 50% LEAD, 50% TIN, STANDARD BRAND. FLUX SHALL BE NEW MURIATIC ACID. <br />SHEET METAL AND FLASHING SHALL BE FORMED, FABRICATED, AND INSTALLED IN THE LARGEST PRACTICAL <br />SECTIONS, AND ADEQUATELY PROVIDE FOR EXPANSION AND CONTRACTION IN THE COMPLETED WORK <br />USING THE HIGHEST STANDARDS OF CONSTRUCTION PRACTICE. THE COMPLETED WORK SHALL PROVIDE <br />WEATHER-TIGHT AND WATERPROOF CONNECTIONS. <br />LOCK SEAMS FLAT AND TRUE TO LINE, 1/2 INCH WIDE, SWEATED FULL WITH SOLDER. <br />MOLDED AND BRAKE-FORMED MEMBERS SHALL BE FINISHED TRUE AND STRAIGHT WITH SHARP LINES AND <br />ANGLES. <br />ALL GALVANIZED METAL SHALL BE SHOP PRIMED WITH ONE COAT OF ZINC DUST-ZINC OXIDE PRIMER OVER <br />ALL SURFACES. <br />ALL WORK SHALL BE ACCURATELY FABRICATED TO MATCH DETAIL AND FITTED TO JOB CONDITIONS. <br />ALL DIMENSIONS INDICATED IN THE CONSTRUCTION DOCUMENTS SHALL BE VERIFIED BY TAKING FIELD <br />MEASUREMENTS. <br />ENTRY DOOR(S) SHALL BE PROVIDED WITH A SINGLE PUSH BUTTON ACTUATOR FOR THE SOLE PURPOSE <br />OF ACTIVATING A BELL(S) OR CHIME WITHIN THE RESIDENCE TO NOTIFY OCCUPANTS OF AN ARRIVAL - THE <br />BELL(S) OR CHIME SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND BE PLACED IN <br />SUCH AN AREA THAT IT CAN BE HEARD THROUGHOUT THE ENTIRE RESIDENCE - PER THE LOCAL <br />JURISDICTION OR CODE ENFORCEMENT. <br />3. <br />WATERPROOF DECKING - CLASS "A" RATED FIRE ASSEMBLY. APPLY ALL WATERPROOF DECK DECK COVERING <br />COMPLETE AND WATER-TIGHT, AS RECOMMENDED BY THE SYSTEM MANUFAC- TURER. DECK SYSTEM SHALL BE <br />I.C.B.O. APPROVED, TRAFFIC BEARING ELASTOMERIC MEM- BRANE SYSTEM BY DEX-O-TEX "WEATHERWEAR" <br />I.C.C. # ESR-1757 OR APPROVED SUBSTITUTE. ALL RECOMMEN- DATIONS SHALL BE STRICTLY FOLLOWED <br />REGARDING STABILITY OF FLOOR, POSITIVE SLOPE AWAY FROM LIVING AREAS, FLASHING AT ALL EDGE AND <br />CORNER CONDITIONS, REINFORCING TAPE AT SUBFLOOR JOINTS, AND METAL REINFORCING AT INSIDE OR <br />OUTSIDE (I.E., STAIR NOSING) CORNERS, ETC. WATER PROOF DECK SHALL BE FLOOD TESTED. <br />PROVIDE MINIMUM 2 INCH THRESHOLD FROM FINISHED INTERIOR FLOOR TO THE HIGHEST FLOOR <br />LEVEL ON ANY ADJOINING DECK OR BALCONY. EXCEPTION PROVIDE MAXIMUM 1 INCH THRESHOLD <br />FROM FINISHED INTERIOR FLOOR TO THE HIGHEST FLOOR LEVEL ON ANY ADJOINING DECK OR <br />BALCONY AT OUT-SWING DOOR CONDITIONS. <br />AS PER CALIFORNIA BUILDING CODE (CURRENT EDITION) SECTION 1203 ENCLOSED ATTICS AND ENCLOSED <br />RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF THE ROOF <br />RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS <br />PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. BLOCKING AND BRIDGING SHALL BE ARRANGED SO <br />AS NOT TO INTERFERE WITH THE MOVEMENT OF AIR. A MINIMUM OF 1 INCH OF AIRSPACE SHALL BE PROVIDED <br />BETWEEN THE INSULATION AND THE ROOF SHEATHING. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, <br />INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. THE NET FREE VENTILATING AREA SHALL NOT BE <br />LESS THAN 1/300 OF THE AREA OF THE SPACE VENTILATED WITH 50 PERCENT OF THE REQUIRED VENTILATING <br />AREA PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT <br />LEAST 3 FEET ABOVE THE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION <br />PROVIDED BY EAVE OR CORNICE VENTS. <br />EXTERIOR OPENINGS INTO THE ATTIC SPACE OF ANY BUILDING INTENDED FOR HUMAN OCCUPANCY SHALL <br />BE PROTECTED TO PREVENT THE ENTRY OF BIRDS, SQUIRRELS, RODENTS, SNAKES AND OTHER SIMILAR <br />CREATURES. OPENINGS FOR VENTILATION HAVING A LEAST DIMENSION OF 1/16 INCH AND 1/4 INCH <br />MAXIMUM SHALL BE PERMITTED. <br />OPENINGS FOR VENTILATION A LEAST DIMENSION LARGER THAN 1/4 INCH SHALL BE PROVIDED WITH <br />CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH PERFORATED VINYL OR SIMILAR <br />MATERIAL WITH OPENINGS HAVING A LEAST DIMENSION OF 1/16 INCH MINIMUM AND 1/4 INCH MAXIMUM.