Laserfiche WebLink
G E N E R A L C O N S T R U C T I O N R E Q U I R E M E N T S <br />DIVISION 9 - <br />32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG <br />DOORS AND WINDOWS <br />MEANS OF EGRESS AND EMERGENCY ESCAPE8.2.3 <br />DIVISION 8 - FINISHESDIVISION 9 - <br />(C O N T I N U E D) <br />FINISHES DIVISION 9 - <br />(CONTINUED)(CONTINUED)(CONTINUED) <br />FINISHES <br />GCR-3 <br />GENERAL <br />CONSTRUCTION <br />REQUIREMENTS <br />FIRE-RATED GLAZING8.3.5 <br />BASEMENTS IN DWELLING UNITS AND EVERY SLEEPING ROOM BELOW THE FOURTH STORY SHALL <br />HAVE AT LEAST ONE OPERABLE WINDOW OR DOOR APPROVED FOR EMERGENCY ESCAPE OR <br />RESCUE THAT SHALL OPEN DIRECTLY INTO A PUBLIC STREET, PUBLIC ALLEY, YARD OR EXIT <br />COURT. THE EMERGENCY DOOR OR WINDOW OPENING SHALL BE OPERABLE FROM THE INSIDE <br />TO PROVIDE A FULL, CLEAR OPENING WITHOUT THE USE OF SEPARATE TOOLS. ESCAPE OR <br />FEET. THE MINIMUM NET CLEAR OPERABLE HEIGHT DIMENSION SHALL BE 24 INCHES. THE MINI- <br />VIDED AS A MEANS OF ESCAPE OR RESCUE, THEY SHALL HAVE A FINISHED SILL HEIGHT NOT <br />MORE THAN 44 INCHES ABOVE THE FLOOR. WINDOW MANUFACTURER/SUPPLIER SHALL VERIFY <br />THAT REQUIRED EGRESS WINDOWS MEET ALL EMERGENCY EXITING REQUIREMENTS OF THE <br />CALIFORNIA BUILDING CODE (CURRENT EDITION), AND SHALL NOTIFY THE ARCHITECT IF DRAWINGS ARE <br />FOUND TO BE IN CONFLICT, PRIOR TO FABRICATION AND DELIVERY. <br />ALL GLASS AND GLAZING SHALL COMPLY WITH REQUIREMENTS SET FORTH IN THE CALIFORNIA <br />BUILDING CODE (CURRENT EDITION), CHAPTER 24. <br />GLAZING AT ALL EXTERIOR OPENING LOCATIONS SHALL BEAR A LABEL CERTIFYING THE <br />CORRESPONDING "U" VALUE, AND SHALL COMPLY WITH REQUIREMENTS SET FORTH IN THE <br />(CURRENT EDITION), SECTION 2406. <br />ALL GLAZING SUBJECT TO HUMAN IMPACT SHALL COMPLY WITH THE CALIFORNIA BUILDING CODE <br />CAULKING COMPOUND SHALL BE GUN-APPLIED, NON-HARDENING, AND NON-MILDEWING. <br />CLEAR GLASS TYPICAL (UNLESS NOTED OTHERWISE). <br />ALL GLASS IN DOORS SHALL BE 3/16" THICK TEMPERED GLASS AND DUAL GLAZED WITH <br />ELEVATIONS FOR DIVIDED LITE LOCATIONS AND PATTERNS (TRUE AND SIMULATED). <br />DUAL GLAZING WITH CLEAR GLASS TYPICAL (UNLESS NOTED OTHERWISE). REFER TO EXTERIOR <br />ALL GLASS IN FIXED AND OPERABLE WINDOWS SHALL BE SINGLE STRENGTH "B" OR BETTER. <br />GLAZING SHALL COMPLY WITH ALL APPLICABLE SECURITY ORDINANCES. <br />"TITLE-24" ENERGY COMPLIANCE CALCULATIONS. <br />TEMPERED GLASS SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS: <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />GLASS AND/OR ACRYLIC BLOCK SHALL BE 3 INCHES THICK( MINIMUM), AND ADDITIONALLY <br />10. <br />9 <br />8 <br />7. <br />WITH MINIMUM 20 MINUTE FIRE-RATING AND FRAME ASSEMBLY. INSTALL FLASHING MATERIAL, <br />REINFORCING, EXPANSION MATERIAL, GROUT/MORTAR AND SEALANT AS RECOMMENDED BY <br />MANUFACTURER. <br />OR RESCUE WINDOWS SHALL HAVE A MINIMUM NET CLEAR OPENABLE AREA OF 5.7 SQUARE <br />MUM NET CLEAR OPERABLE WIDTH DIMENSION SHALL BE 20 INCHES. WHEN WINDOWS ARE PRO- <br />8.3.1 <br />8.3 <br />STANDARDS <br />GLASS AND GLAZING <br />8.3.2 MATERIALS <br />8.3.3 SAFETY GLAZING <br />BARRIER BETWEEN THE DOOR AND THE GLAZING.) <br />GLASS IS NOT REQUIRED WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT <br />GLAZING IS LESS THAN 60 INCHES ABOVE THE WALKING SURFACE ( EXCEPTION: TEMPERED <br />THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE <br />EXPOSED EDGE OF THE GLAZING IS WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF <br />GLAZING IN FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST <br />DOORS SHALL OPEN OUTWARD. <br />IS LESS THAN 60 INCHES ABOVE A STANDING SURFACE AND DRAIN INLET. HINGED SHOWER <br />CLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE THE GLAZING <br />GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />GLAZING IN ALL UNFRAMED SWINGING DOORS. <br />GLAZING IN STORM DOORS. <br />SWINGING DOORS OTHER THAN WARDROBE DOORS. <br />GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN <br />GLAZING IN INGRESS AND EGRESS DOORS EXCEPT JALOUSIES. <br />ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL EN- <br />GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS 5 AND 6, THAT MEET ALL OF THE FOLLOWING CONDITIONS: <br />7.1 <br />7.2 <br />7.3 <br />7.4 <br />GLAZING IN RAILINGS REGARDLESS OF HEIGHT ABOVE A WALKING SURFACE. <br />GLAZING IN WALLS ENCLOSING STAIRWAY LANDINGS OR WITHIN 5 FEET OF THE BOTTOM <br />AND TOP OF THE STAIRWAYS WHERE THE BOTTOM EDGE OF THE GLASS IS LESS THAN <br />60 INCHES ABOVE A WALKING SURFACE <br />GLAZING IN WARDROBE DOORS SHALL MEET THE IMPACT TEST REQUIREMENTS FOR SAFETY <br />GLAZING AS SET FORTH IN THE CALIFORNIA BUILDING CODE (CURRENT EDITION), <br />EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET. <br />THE GLAZING <br />ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE PLANE OF <br />EXPOSED TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />EXPOSED BOTTOM EDGE LESS THAT 18 INCHES ABOVE THE FLOOR. <br />8.3.4 GLASS AND/OR ACRYLIC BLOCK <br />SIZED AS SPECIFIED IN HE CONSTRUCTION DOCUMENTS. PATTERN SHALL BE "PITTSBURGH <br />CORNING" - DECORA (OR EQUAL), OR AS SELECTED BY CLIENT. IN EXTERIOR WINDOW TYPE <br />APPLICATIONS, BLOCK SHALL BE FACTORY SET IN MANUFACTURED WINDOW FRAME COMPLETE <br />FLOORING LOCATIONS, UNLESS NOTED OTHERWISE IN THE CONSTRUCTION DOCUMENTS. <br />TILE AND GROUT SHALL BE AS SELECTED BY OWNER/CLIENT. <br />REFER TO "FINISH SCHEDULE" IN SECTION 9.5 - "PAINTING AND FINISHING", FOR SPECIFIC <br />MATERIALS9.4.3 <br />CERAMIC TILE <br />CUSHIONED VINYL SHEETING <br />LEGEND: <br />DOCUMENTS. <br />BETWEEN ADJACENT ROOMS, UNLESS INDICATED OTHERWISE IN THE CONSTRUCTION <br />CHANGES IN FLOOR MATERIAL SHALL OCCUR AT THE CENTERLINE OF THE DOOR <br />SHALL BE CARPET, UNLESS NOTED OTHERWISE. <br />MASTER BATHROOM AND VANITY PORTION OF "JACK AND JILL" SECONDARY BATHROOMS <br />CONSTRUCTION DOCUMENTS. <br />FLOORING MATERIAL SHALL BE AS SCHEDULED, UNLESS OTHERWISE INDICATED IN THE <br />CONCRETE TAPED TAPED <br />FLATFLAT <br />SGSG**VS <br />CT <br />FLATFLATCARPET <br />FLATFLATCARPET <br />FLATFLATCARPET <br />FLATFLATCARPET <br />FLATFLATCARPET <br />FLATFLATCARPET <br />FLATFLATCARPET <br />FLATFLATCARPET <br />SGSGVS <br />SGSGVS <br />SGSGVS <br />FLATFLAT <br />FLATFLAT <br />BY <br />SELECTED <br />AS <br />CLIENT <br />OWNER/ <br />FLAT <br />ROOM MATERIAL TEXTURE TEXTURE PAINT PAINT <br />SG <br />FLAT <br />CEILING <br />SG <br />WALLCEILING <br />OWNER/ <br />CLIENT <br />AS <br />SELECTED <br />BY <br />WALL <br />VS <br />CT <br />CARPET <br />CARPET <br />* FLOOR <br />9.5.6 FINISH SCHEDULE <br />CT <br />VS <br />** <br />* <br />NOTE: <br />SHALL RECEIVE ONE COAT SEALER AND ONE COAT FLAT PAINT, UNLESS NOTED OTHERWISE. <br />AND ONE COAT SEMI-GLOSS ENAMEL, UNLESS NOTED OTHERWISE. ALL OTHER ROOMS <br />KITCHENS, NOOKS, BATHROOMS, AND LAUNDRY ROOMS, SHALL RECEIVE ONE COAT SEALER <br />INTERIOR PAINTING AND FINISHING9.5.5 <br />PER OWNER/CLIENT. <br />ALL EXPOSED INTERIOR WOOD BEAMS SHALL BE PAINTED TO MATCH CEILING OR SOLID STAIN <br />THE NUMBER OF COATS ABOVE SHALL BE CONSIDERED MINIMUM. APPLY ADDITIONAL COATS <br />IF REQUIRED TO PROVIDE FULL AND EVEN COVERAGE THROUGHOUT. <br />FACES. <br />HALLWAY <br />OFFICE <br />POWDER <br />GARAGE <br />CLOSET <br />TOILET COMP. <br />BATHROOM <br />STUDY <br />LIBRARY <br />BEDROOM <br />DINING <br />LIVING <br />FOYER <br />NOOK <br />MORNING <br />FAMILY <br />LAUNDRY <br />KITCHEN <br />EXCEPT SHELVING. <br />PRIMER AND ONE COAT SEMI-GLOSS ENAMEL. <br />DOORS, FRAME, WOOD BASE AND CASING, AND SHELF CLEATS SHALL RECEIVE ONE COAT <br />WARDROBES AND WALK-IN CLOSETS SHALL BE FINISHED AS SPECIFIED FOR ADJOINING ROOM, <br />SEALER ONE COAT STAIN AND TWO COATS LACQUER. <br />STAIN GRADE WOOD HAND RAILINGS, WOOD CAPS, ETC., SHALL RECEIVE ONE COAT SANDING <br />PAINT GRADE CABINETS, RAILINGS, WOOD CAPS, ETC., SHALL RECEIVE ONE COAT SEALER AND <br />ONE COAT SEMI-GLOSS ENAMEL. <br />METAL SURFACES SHALL RECEIVE PRIMER AND ONE COAT PAINT TO MATCH ADJACENT SUR- <br />TWO COATS LACQUER. <br />STAIN GRADE CABINETS SHALL RECEIVE ONE COAT SANDING SEALER, ONE COAT STAIN, AND <br />ALL SIX SIDES OF DOORS SHALL BE SEALED. <br />FULLY SEAL AND PRIME ALL CUT ENDS OF WOOD MEMBERS IN CONTACT WITH OTHER WOOD <br />CEILINGS AND WALLS: <br />MEMBERS. <br />THE NUMBER OF COATS ABOVE SHALL BE CONSIDERED MINIMUM. APPLY ADDITIONAL COAT <br />IF REQUIRED TO PROVIDE FULL AND EVEN COVERAGE THROUGHOUT. <br />EXTERIOR PAINTING AND STAINING9.5.4 <br />MATERIALS9.5.3 <br />REMOVE ALL OIL, GREASE, BOND BREAKING AGENTS, DUST MILL SCALE AND EFFLORESCENCE. <br />EXPOSED METAL, INCLUDING VENT PIPES, EXHAUST VENTS, HEATING AND AIR CONDITIONING UNITS, <br />TRIM, ETC., SHALL RECEIVE TWO COATS OF PAINT. <br />SHALL MATCH ADJACENT SURFACES. <br />ALL EXPOSED EDGES OF TRIM SHALL BE SAME COLOR AS FACE. <br />GRILLS, ETC., SHALL RECEIVE TWO COATS OF PAINT OVER ONE COAT OF PRIMER. COLOR <br />EXTERIOR WOOD, INCLUDING SIDING, GARAGE DOORS, RAILINGS, FASCIA, EXPOSED BEAMS, ALL <br />EXTERIOR EXPOSED CONCRETE AND MASONRY SHALL RECEIVE TWO COATS OF MASONRY PAINT. <br />PAINT AND STAIN COLORS SHALL BE AS SELECTED BY OWNER/CIENT, AND APPROVED BY <br />ARCHITECT. <br />SURFACES SHALL BE CLEAN AND DRY, AND IN SUITABLE CONDITION FOR FINISH SPECIFIED. <br />PREPARATION OF SURFACES9.5.2 <br />CRACKS, HOLES, AND KNOTS SHALL BE FILLED, SANDED SMOOTH, AND SEALED. WOOD SUR- <br />SANDING DUST SHALL BE COMPLETELY REMOVED. <br />HARDWARE SHALL BE MASKED OR REMOVED PRIOR TO PAINTING OR STAINING <br />FACES, EXCEPT ROUGH-SAWN OR RESAWN WOOD, SHALL BE SANDED PERFECTLY SMOOTH. <br />SUBMIT LIST OF MATERIALS AND MANUFACTURERS FOR OWNER/CLIENT AND ARCHITECTS <br />CONTAINERS. <br />ALL MATERIALS SHALL BE DELIVERED TO THE SITE IN SEALED ORIGINAL MANUFACTURER'S <br />REVIEW. <br />TRIM AND OTHER FINISH WORK SHALL BE BACK PAINTED PRIOR TO INSTALLATION. <br />SEMI-GLOSS PAINT SHALL BE EITHER ROLLER OR BRUSH APPLIED. REFER TO "FINISH SCHED- <br />PAINT FINISHES SHALL BE CUT SHARPLY TO LINE. PROTECT ADJACENT SURFACES. <br />STRUCTION DOCUMENTS. <br />ULE" IN THIS SECTION, FOR SPECIFIC ROOM LOCATIONS, UNLESS NOTED OTHERWISE IN THE CON- <br />PAINTING AND FINISHING <br />WORKMANSHIP <br />9.5 <br />9.5.1 <br />TIONS. <br />INSTALLATION9.4.2 <br />STANDARDS9.4.1 <br />TILE9.4.1 <br />ALL ADHESIVES SHALL BE AS RECOMMENDED BY THE MANUFACTURER OF THE FLOOR <br />MATERIALS9.3.2 <br />RUNS, SAGS, STROKES, OR SKIPS. <br />EACH COAT SHALL BE UNIFORMLY APPLIED, WELL BRUSHED OUT AND FREE OF BRUSH MARKS, <br />SURFACES SHALL BE PRIMED AS RECOMMENDED BY THE MANUFACTURER. <br />SUBFLOORS SHALL BE CLEAN, FREE OF DUST AND PERFECTLY DRY, LEVEL AND SMOOTH. <br />TURER'S PRINTED INSTALLATION INSTRUCTIONS. <br />INSTALL ALL WORK IN ACCORDANCE WITH THE "RESILIENT TILE INSTITUTE", AND THE MANUFAC- <br />ALL VINYL SHEETHING SHALL BE SELECTED BY OWNER/CLIENT. <br />COVERING. <br />THE "TILE COUNCIL OF AMERICA" - T.C.A.. <br />ALL WORK AND MATERIALS SHALL MEET THE LATEST EDITION PERFORMANCE STANDARD OF <br />REFER TO "FINISH SCHEDULE" IN SECTION 9.5 - "PAINTING AND FINISHING", FOR SPECIFIC <br />FLOORING LOCATIONS, UNLESS NOTED OTHERWISE IN THE CONSTRUCTION DOCUMENTS. <br />TOWARDS FLOOR DRAIN. <br />PROVIDE POSITIVE SLOPE (TO DRAIN) AT TILE SEATS WITHIN SHOWERS AND AT FLOOR <br />"I.E., TUBS AND SHOWERS". <br />APPLICATION OF PAINT, STAIN OR OTHER COATINGS SHALL BE IN STRICT ACCORDANCE WITH <br />THE "PAINTING AND DECORATING CONTRACTORS OF AMERICA" - P.D.C.A., "PAINTINGS SPEC- <br />IFICATIONS MANUAL" AND PER THE MANUFACTURER'S PRINTED INSTRUCTIONS. READY MIXED <br />PAINT SHALL NOT BE THINNED, EXCEPT AS PERMITTED IN THE APPLICATION PRINTED INSTRUC- <br />CIL OF AMERICA" - T.C.A. STANDARDS, AT ALL AREAS SUBJECT TO MOISTURE AND WATER. <br />AS RECOMMENDED BY MANUFACTURER AND "CERAMIC TILE INSTITUTE - C.T.I., AND "TILE COUN- <br />PROVIDE WATERPROOF MEMBRANE BENEATH TILE OVER WATER RESISTANT BACKING BOARD <br />OF AMERICA" STANDARDS. <br />TILE INSTALLED ON FLOOR (CONCRETE SLAB OR WOOD FRAMING), SHALL MEET THE "TILE <br />COUNCIL OF AMERICA" STANDARDS. <br />TILE INSTALLED AT COUNTERS, TUBS, AND SHOWERS SHALL BE "MUD SET" PER "TILE COUNCIL <br />INSTALLATION9.3.1 <br />FINISHES9.2.5 <br />MATERIALS (3-COAT EXTERIOR PLASTER)9.2.3 <br />A CORROSION-RESISTANT METAL BASE SCREED SHALL BE PROVIDED AT THE FOUNDATION, AS <br />DETAILED. <br />OWNER/CLIENT. <br />ALL OUTSIDE CORNERS SHALL BE REINFORCED WITH CORNER BEAD/GUARD, AS SELECTED BY <br />EXTERIOR PLASTER FINISH AND COLOR SHALL BE AS SELECTED BY ARCHITECT. <br />EXTERIOR PLASTER SOFFITS AND RECESSES. <br />A CORROSION-RESISTANT METAL DRIP SCREED SHALL BE PROVIDED AT UNDERSIDE OF ALL <br />PLASTER MANUFACTURER. <br />ALL SOFFITS SHALL RECEIVE A "HIGH-RIB" LATH AS RECOMMENDED BY THE EXTERIOR <br />IBILITY OF THE OWNER/CLIENT BASED ON THE RECOMMENDATIONS OF THE EXTERIOR PLASTER <br />INSTALLATION9.2.2 <br />STANDARDS <br />EXTERIOR LATH AND PLASTER9.2 <br />9.2.1 <br />FINISHES9.1.4 <br />APPLICATION OF THE EXTERIOR WALL WEATHER-RESISTIVE BARRIER SHALL BE THE RESPONS- <br />MANUFACTURING REPRESENTATIVE. <br />PROVIDE A MINIMUM SLOPE OF 1/4" PER FOOT (UNLESS NOTED OTHERWISE), AT ALL SUBSTRATE <br />DOCUMENTS, AND DESCRIBED IN SECTION 7.3.5 - "FLASHING". <br />PROVIDE ELASTOMERIC MEMBRANE MATERIALS AS NOTED/DETAILED IN THE CONSTRUCTION <br />"COLOR COAT", AT EXPOSED SURFACES. <br />ALL EXPOSED CONCRETE AT FOUNDATION SHALL BE FINISHED WITH EXTERIOR PLASTER <br />FACTURER. ARCHITECT SHALL BE NOTIFIED OF LOCATIONS PRIOR TO INSTALLATION. <br />INSTALL EXPANSION/WEEP JOINTS AS RECOMMENDED BY THE EXTERIOR PLASTER MANU- <br />LOCATIONS ON WHICH EXTERIOR PLASTER SHALL BE APPLIED. <br />PROVIDED. <br />ALL WORK SHALL COMPLY WITH THE INSTALLATION STANDARDS OF THE PLASTER PRODUCTS <br />CORNER BEAD AT EXTERNAL CORNERS SHALL BE AS SELECTED BY OWNER/CLIENT. <br />L-SHAPED TRIM AT EXPOSED EDGES (TYPICAL). <br />FOR THE USE SPECIFIED. <br />ALL TAPE AND COMPOUND SHALL BE RECOMMENDED BY THE GYPSUM BOARD MANUFACTURER <br />2. <br />1. <br />REFER TO SECTION 9.5 - "PAINTING AND FINISHING". <br />RESILIENT CHANNELS SHALL BE PROVIDED AT FIRE/SOUND RATED FLOOR/CEILING ASSEMBLIES, <br />IN AREAS SUBJECT TO MOISTURE AT FIRE ASSEMBLIES, AS DETAILED. <br />AT EXTERIOR LOCATIONS, EXTERIOR GRADE, FIRE-RATED, GYPSUM SHEATHING SHALL BE USED <br />AS DETAILED. <br />METAL CORNER BEAD, CASING BEAD, AND EDGE TRIM, SHALL BE GALVANIZED AND NAILED. <br />MATERIALS9.1.3 <br />INSTALLATION9.1.2 <br />STANDARDS9.1.1 <br />AT ALL CEILINGS, PROVIDE 5/8" THICK GYPSUM CEILING BOARD WHERE FRAMING SPACING <br />IS MAINTAINED. <br />AT TUB/SHOWER ENCLOSURES SHALL BE INSTALLED IN SUCH A MANNER THAT THERE ARE NO <br />SURFACES OUT OF ALIGNMENT WITH ADJACENT SURFACES AND THE TRUE PLANE OF THE WALLS <br />EXCEEDS 16" O.C. <br />MOISTURE RESISTANT WALLBOARD AND CEILING BOARD SHALL BE USED IN "WET AREAS" AS <br />RECOMMENDED BY THE GYPSUM BOARD MANUFACTURER. ALL GYPSUM WALLBOARD LOCATED <br />TAPED JOINTS AT FIRE/SOUND RATED WALLS AS NOTED/DETAILED AND AT OTHER WALLS AND <br />GYPSUM WALLBOARD AND CEILING BOARD SHALL BE 5/8" THICK, FIRE-RATED TYPE "X" WITH <br />WISE INDICATED IN THE CONSTRUCTION DOCUMENTS. <br />NOTED/DETAILED, WITH FASTENERS SIZED ACCORDINGLY. <br />CEILING WHERE NOTED IN THE CONSTRICTION DOCUMENTS. PROVIDE MULTIPLE LAYERS IF <br />ATION AND FINISHING OF GYPSUM WALLBOARD". <br />ARDS OF THE "GYPSUM ASSOCIATION" - GA, "RECOMMENDED SPECIFICATIONS FOR THE APPLIC- <br />ALL WORK AND MATERIALS SHALL COMPLY WITH THE LATEST EDITION PERFORMANCE STAND- <br />CODE (CURRENT EDITION), CHAPTER 25. <br />ALL WORK SHALL COMPLY WITH THE REQUIREMENTS SET FORTH IN THE CALIFORNIA BUILDING <br />TRUE TO PLANE, SECURELY ATTACHED. <br />METAL TRIM SHALL BE TIGHT TO WALLBOARD AND CEILING BOARD EDGES, PLUMB, LEVEL, AND <br />PROVIDE METAL TRIM AT ALL EXPOSED EDGES AND EXTERNAL CORNERS. <br />TECTION FOR THE INSTALLATION IS PROVIDED. <br />GYPSUM WALLBOARD AND CEILING BOARD SHALL NOT BE INSTALLED UNTIL WEATHER PRO- <br />ALL JOINTS IN FINISHED SURFACES SHALL BE TAPED AND FINISHED WITH JOINT CEMENT. <br />REINFORCE ALL CORNERS. <br />GYPSUM WALLBOARD AND CEILING BOARD SHALL BE 1/2" THICK THROUGHOUT, UNLESS OTHER- <br />CONCEAL EXPOSED NAIL OR SCREW HEADS WITH JOINT COMPOUND. <br />ALL EXPOSED WOOD BEAMS, POSTS, ETC., SHALL BE PROTECTED WITH GYPSUM WALLBOARD, <br />UNLESS OTHERWISE INDICATED IN THE CONSTRUCTION DOCUMENTS. <br />GARAGE DOOR HARDWARE8.5.2 <br />FINISH HARDWARE <br />HARDWARE <br />8.5.1 <br />8.5 <br />ALL FINISH HARDWARE SHALL BE AS SELECTED BY CLIENT. EACH INDIVIDUAL PRIVATE <br />DWELLING UNIT SHALL BE KEYED SEPARATELY. <br />8.4.2 THRESHOLDS <br />WHEN AND WHERE REQUIRED. <br />THRESHOLDS SHALL MEET ALL APPLICABLE DISABLED ACCESSIBLE ROUTE REQUIREMENTS <br />OTHERWISE INSTALLED TO PREVENT WATER INTRUSION. <br />THRESHOLDS SHALL BE SET IN CORROSION-RESISTANT SILL PANS, CAULKED AND SEALED OR <br />CONTACT WITH CONCRETE AS REQUIRED TO PREVENT CORROSION. <br />ALL THRESHOLDS SHALL BE ANODIZED ALUMINUM AND SHALL BE SEPARATED FROM DIRECT <br />WEATHER-STRIPPING AND THRESHOLDS <br />WEATHER-STRIPPING <br />8.4 <br />8.4.1 <br />SPACE, SHALL BE COMPLETELY WEATHER-STRIPPED WITH PENETRATIONS CAULKED AND <br />ALL EXTERIOR DOORS AND WINDOWS SEPARATING CONDITIONED SPACE FROM UNCONDITIONED <br />SEALED, IN AN EFFORT TO PROTECT AGAINST INTRUSION AND TO LIMIT AIR INFILTRATION. <br />9.3 RESILIENT FLOORING <br />9.1 GYPSUM WALLBOARD AND CEILING BOARD <br />CALIFORNIA BUILDING CODE (CURRENT EDITION), SECTION 2406.3. <br />ALL GLAZING IN HAZARDOUS AREAS SHALL BE TEMPERED GLASS AND COMPLY WITH THE <br />MATERIALS (1-COAT EXTERIOR PLASTER)9.2.4 <br />FIRE-RATED GLAZING (WHEN REQUIRED) SHALL BE A MINIMUM OF 1/4 INCH THICK WIRE GLASS IN METAL <br />FRAME AND SHALL COMPLY WITH REQUIREMENTS SET FORTH IN THE CALIFORNIA BUILDING CODE (CURRENT <br />EDITION), CHAPTER 7. GLAZING SHALL MEET A MINIMUM 20 MINUTE FIRE-RATING, AND SHALL HAVE AN <br />APPROVED LABEL OR LISTING MARK, INDICATING THE FIRE-PROTECTION RATING, WHICH IS PERMANENTLY <br />AFFIXED AT THE FACTORY WHERE FABRICATION AND ASSEMBLY ARE DONE. <br />ALL FASTENERS SHALL BE AS RECOMMENDED BY THE GYPSUM BOARD MANUFACTURER AND MEET THE <br />REQUIREMENTS SET FORTH IN THE CALIFORNIA BUILDING CODE (CURRENT EDITION) REFER TO CON- <br />STRUCTION DOCUMENTS FOR SPECIAL NAILING REQUIREMENTS AT SHEAR WALLS AND FIRE/ SOUND RATED <br />ASSEMBLIES. THE CONTRACTOR, AT HIS OPTION, MAY USE WALLBOARD SCREWS IN LIEU OF NAILS AS <br />ALLOWED BY THE RATED ASSEMBLY AND LOCAL CODE REQUIREMENTS, AND APPROVED BY THE <br />STRUCTURAL ENGINEER OF RECORDS. <br />ALL WORK AND MATERIALS SHALL COMPLY WITH THE LATEST EDITION PERFORMANCE STANDARDS OF THE <br />"LATHING AND PLASTERING CONTRACTOR'S ASSOCIATION" - L.P.C.A., AS WELL AS THE REQUIREMENTS SET FORTH <br />IN THE CALIFORNIA BUILDING CODE (CURRENT EDITION), CHAPTER 25. <br />ALL GARAGE DOORS SHALL BE ADJUSTED AND COUNTER BALANCED FOR PROPER OPERATION. SPRINGS SHALL <br />BE PERMANENTLY IDENTIFIED AS TO MANUFACTURER AND ALSO TO INDICATED MAXIMUM RECOMMENDED <br />STRETCH. BOTH SPRINGS AND CONTAINMENT DEVICES SHALL BEAR INFORMATION STATING THAT THEY HAVE <br />BEEN MANUFACTURED IN ACCORDANCE WITH REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF HOUSING <br />AND COMMUNITY DEVELOPMENT. <br />10.1 INSTALLATION <br />DRAWINGS. ALL WORK SHALL BE SET PLUMB, LEVEL, AND TRUE TO LINE, AND SHALL REPRESENT <br />NUMERALS SHALL BE OF NON-CORROSIVE METAL, WITH DESIGN AS SELECTED BY OWNER/CLIENT <br />ARRESTOR SHALL BE OF NONFLAMMABLE MATERIAL APPROVED BY THE FIRE MARSHALL <br />AS INDICATED IN THE CONSTRUCTION DOCUMENTS, AND EQUIPPED WITH AN APPROVED SPARK <br />FIREPLACE MANUFACTURER, MODEL, AND AN APPROVED E.S.R. EVALUATION REPORT SHALL BE <br />BUILDING AND MECHANICAL CODES. <br />MEET THE APPROVAL OF THE FIREPLACE MANUFACTURER AND THE APPROVED EVALUATION <br />WHICH ARRESTS BURNING CARBON AND SPARKS. DECORATIVE CHIMNEY CAP SHROUD SHALL <br />REPORT. INSTALLATION AND CLEARANCE TO COMBUSTIBLE MATERIALS, SHALL BE PER <br />MANUFACTURER'S REQUIREMENTS. <br />FACTURER'S RECOMMENDED PRINTED INSTALLATION INSTRUCTIONS AND ALL APPLICABLE <br />PREFABFICRATED METAL FIREBOXES SHALL BE INSTALLED IN ACCORDANCE WITH THE MANU- <br />ERIALS WITH ALL SELECTED FIXTURES AND APPLIANCES. <br />A NEAT AND FINISHED APPEARANCE. BACKING PLATES, ANCHORS, BLOCKS, FASTENERS, ETC., <br />SHALL BE PROVIDED AS NECESSARY TO PROPERLY ATTACH ALL SPECIALTY ITEMS. <br />THE GENERAL CONTRACTOR SHALL VERIFY COMPATIBILITY OF ALL ADJACENT FINISH MAT- <br />ALL MISCELLANEOUS SPECIALTY ITEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANU- <br />FACTURER'S RECOMMENDED PRINTED INSTALLATION INSTRUCTIONS AND ACCEPTED SHOP <br />AND APPROVED BY ARCHITECT. <br />10.2 METAL FIREPLACES <br />COLOR TO THE BACKGROUND TO WHICH THEY ARE ATTACHED. <br />HEIGHT OF NUMERALS SHALL BE NO LESS THAN 4-INCHES, AND SHALL BE OF A CONTRASTING <br />MAILBOXES SHALL BE AS SELECTED BY OWNER/CLIENT AND APPROVED BY ARCHITECT. <br />FINISH HARDWARE SHALL BE AS SPECIFIED BY OWNER/CLIENT AND APPROVED BY ARCHITECT. <br />AS VIEWED FROM THE STREET, AND MEET ALL LOCAL CODE REQUIREMENTS. <br />ADDRESS NUMBER SHALL BE ILLUMINATED IN A PROMINENT LOCATION, VISIBLE AND LEGIBLE <br />10.3 ADDRESS NUMBERS <br />10.4 MAILBOXES <br />10.5 FINISH HARDWARE <br />MANUFACTURED DECORATIVE GAS "FIREPLACE" APPLIANCES SHALL MEET ALL APPLICABLE REQUIREMENTS FOR GAS <br />APPLIANCES AS REQUIRED BY THE CALIFORNIA MECHANICAL CODE (CURRENT EDITION). APPLIANCE MANUFACTURER <br />AND MODEL SHALL BE AS INDICATED IN THE CONSTRUCTION DOC- UMENTS AND SHALL BE U.L. APPROVED. <br />CLEARANCE TO COMBUSTIBLE MATERIALS, INSTAL- LATION AND VENT/FLUE TERMINATION SHALL BE PER <br />MANUFACTURER'S REQUIREMENTS. GAS "FIREPLACE" APPLIANCE SHALL BE EQUIPPED WITH AN ELECTRICAL IGNITION, <br />WALL-MOUNTED SWITCH (36" A.F.F.), WITH LOCATION AS INDICATED IN THE CONSTRUCTION DOCUMENTS. <br />STANDARD 24-2, PART II. <br />ALL WOOD TRIM, INCLUDING BUT NOT LIMITED TO, FASCIA'S CORBELS, TRELLIS MEMBERS, OPEN DECKS, AND <br />OTHER FINISH WORK, ETC., SHALL BE PRE-PRIMED ON ALL SURFACES, INCLUDING NON-EXPOSED, PRIOR TO <br />INSTALLATION. FULLY SEAL AND PRIME ALL CUT ENDS OF WOOD MEMBERS IN CONTACT WITH OTHER WOOD <br />MEMBERS. <br />3-COAT STUCCO APPLIED OVER PLYWOOD SHEATHING TO HAVE (2) LAYERS OF (TYPE 1, STYLE 2, GRADE "D", 60 <br />MIN.) WEATHER RESISTIVE BARRIER. - CALIFORNIA BUILDING CODE (CURRENT EDITION), SECTION 2510.6. <br />ALL WALLS SHALL RECEIVE A MINIMUM 7/8" THICK, THREE COAT APPLICATION WITH INTEGRAL COLOR COAT <br />(PAINT AT ACCENT AREAS ONLY) OVER 1 1/4" CORROSION-RESISTANT METAL WIRE MESH OVER (1) LAYER OF <br />(TYPE I, STYLE 2, GRADE "D", 60 MIN.) WEATHER RESISTIVE BARRIER AT WALLS (1) LAYER OF ELASTOMERIC <br />MEMBRANE AT ALL SURFACES OTHER THAN VERTICAL. APPLICATIONS SHALL CONFORM TO THE MINIMUM <br />REQUIREMENTS OF CHAPTER 25 OF THE CURRENT EDITION OF THE C.B.C. <br />OWNER/CLIENT. <br />AT GABLE END CONDITIONS AS WELL AS ANY CHASES, PROVIDE A MINIMUM OF 1 1/2 INCHES MINERAL FIBER <br />INSULATION, 1/4 INCH THICK PLYWOOD, HARDBOARD, GYPSUM BOARD OR APPROVED THERMAL BARRIER TO <br />COMPLETELY COVER THE FOAM INSULATION FROM THE INTERIOR OF THE GABLE-ENDS AND CHASES. <br />A CORROSION-RESISTANT METAL BASE SCREED SHALL BE PROVIDED AT THE FOUNDATION, AS <br />ALL OUTSIDE CORNERS SHALL BE REINFORCED WITH CORNER BEAD/GUARD, AS SELECTED BY <br />DETAILED. <br />ONE-COAT EXTERIOR PLASTER (STUCCO) SYSTEM. COLOR COAT OVER ONE INCH THICK POLYSTYRENE OVER <br />(WEATHER RESISTIVE BARRIER, TYPE 1, TYLE 2, GRADE D-60) PER CALIFORNIA BUILDING CODE (CURRENT <br />EDITION). ALSO REFER TO MINIMUM INSTALLATION REQUIREMENTS AS PER MANUFACTURER.