Laserfiche WebLink
G E N E R A L C O N S T R U C T I O N R E Q U I R E M E N T S <br />DIVISION 15 - <br />32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG <br />SPECIALTIESDIVISION 10 - MECHANICALDIVISION 15 - <br />(C O N T I N U E D) <br />MECHANICAL <br />(CONTINUED)(CONTINUED)(CONTINUED) <br />GCR-4 <br />GENERAL <br />CONSTRUCTION <br />REQUIREMENTS <br />EQUIPMENTDIVISION 11 - <br />SPECIAL EQUIPMENT11.1 <br />CALIFORNIA MECHANICAL CODE (CURRENT EDITION), AND THE FOLLOWING: <br />ATTIC FORCED-AIR-UNITS (F.A.U.) SHALL COMPLY WITH REQUIREMENTS SET FORTH IN THE <br />5. <br />4. <br />ALL EQUIPMENT CLOSETS SHALL BE SIZED TO PROVIDE 6" (MIN.) CLEARANCE FROM THE EQUIP- <br />MENT UNIT AT THE FRONT, REAR AND SIDES, OR PER APPLICABLE CODES. VERTICAL FAN COIL <br />UNIT CLEARANCES SHALL BE PER APPLICABLE CODES. <br />3. <br />2. <br />ALL FUEL BURNING EQUIPMENT LOCATED IN GARAGES AND SUBJECT TO MECHANICAL DAM- <br />CONSTRUCTION DOCUMENTS, AND AS REQUIRED BY THE CALIFORNIA MECHANICAL CODE. <br />MECHANICAL CODE (CURRENT EDITION). <br />BE PROVIDED FOR EQUIPMENT AS PER MANUFACTURER'S REQUIREMENTS AND THE CALIFORNIA <br />FLUES, HIGH AND LOW COMBUSTION AIR VENTING, AND FRESH AIR DUCTING AND GRILLS, SHALL <br />ALL PENETRATIONS OF FIRE ASSEMBLIES SHALL MEET THE REQUIREMENTS OF THE CALIFORNIA <br />BUILDING CODE (CURRENT EDITION). <br />ALL DUCTWORK SHALL BE CONSTRUCTED, INSTALLED, AND INSULATED PER REQUIREMENTS SET <br />FORTH IN THE CALIFORNIA MECHANICAL CODE (CURRENT EDITION). <br />ELEMENTS, WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. <br />SHALL BE MADE WHICH WOULD COMPROMISE THE DESIGNED STRUCTURAL INTEGRITY OF SUCH <br />NO ALTERATIONS TO THE STRUCTURE FRAME, DIAPHRAGMS, CONNECTIONS OR SHEAR PANELS, <br />JURISDICTION INCLUDING ALL COUNTY AND STATE ORDINANCES. NOTHING IN THE CONSTRUC- <br />COMPLY WITH ALL REQUIREMENTS OF ALL LEGALLY CONSTITUTED PUBLIC AUTHORITIES HAVING <br />OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS STANDARDS, AND SHALL <br />ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH LATEST AMERICAN SOCIETY <br />WORK NOT CONFORMING TO ALL APPLICABLE CODES, RULES, REGULATIONS, OR AMENDMENTS. <br />TION DOCUMENTS, INCLUDING THESE GENERAL NOTES, SHALL BE CONSTRUED TO ALLOW ANY <br />NOT A PART OF THESE GENERAL NOTES. <br />ALL CLEARANCE AND FIT REQUIREMENTS SHALL BE VERIFIED BY TAKING FIELD MEASURE- <br />MENTS. PROPER FIT AND ATTACHMENTS OF ALL PARTS IS REQUIRED. <br />DIVISION 12 - FURNISHINGS <br />UNITS (HORIZONTAL OR VERTICAL). <br />ROOF/ATTIC FRAMING, INCLUDING PREFABRICATED TRUSSES, SHALL BE DESIGNED IN SUCH A <br />MECHANICAL CODE (CURRENT EDITION). <br />WATER-RESISTIVE MEMBRANE AT EXTERIOR WALLS. <br />ELASTOMERIC MEMBRANE MATERIALS SHALL BE PROVIDED AT ALL PENETRATIONS OF THE <br />FORCED-AIR-UNITS SHALL BE INSTALLED IN ATTIC OR ON 16" HIGH PLATFORM AT "CONDI- <br />TIONED SPACE" AREA OR ON 18" HIGH PLATFORM AT GARAGE, AS REQUIRED BY THE CALIFORNIA <br />DIVISION 13 - <br />13.1 BUILDING SECURITY <br />SPECIAL CONSTRUCTION <br />DIVISION 14 - CONVEYING SYSTEMS <br />NOT A PART OF THESE GENERAL NOTES. <br />15.1 HEATING AND AIR CONDITIONING <br />15.1.1 STANDARDS <br />15.1.2 INSTALLATION <br />MANNER AS TO PROVIDE ALL REQUIRED CLEARANCES FOR ATTIC-MOUNTED FORCED-AIR- <br />1.PROVIDE REQUIRED CLEARANCES FOR DUCT WORK AND TO COMBUSTIBLE MATERIALS. <br />DOOR AND PASSAGEWAY, CONTINUOUS TO THE F.A.U. AND IT'S CONTROLS. A 22" X 30" <br />PROVIDE MINIMUM 30" X 30" ATTIC ACCESS OPENING WITH FULLY WEATHER-STRIPPED <br />LARGEST PIECE OF F.A.U. EQUIPMENT CAN BE REMOVED THROUGH THE OPENING. <br />ACCESS OPENING WITH FULLY WEATHER-STRIPPED DOOR MAY BE USED PROVIDED THE <br />PROVIDE AN UNOBSTRUCTED CONTINUOUS SOLID FLOOR PASSAGEWAY NOT LESS THAN 24" <br />WIDE, NOT TO EXCEED 20' FROM THE ATTIC ACCESS OPENING TO THE F.A.U.. <br />PROVIDE A LEVEL WORKING PLATFORM 30" DEEP IN FRONT OF THE ENTIRE FIREBOX SIDE <br />OF THE F.A.U., AND TO ALL SERVICEABLE CONTROLS, FILTERS, ETC. <br />PROVIDE A PERMANENT ELECTRICAL OUTLET AND SWITCHED LIGHT FIXTURE. <br />AGE FROM THE NORMAL VEHICULAR PATH, SHALL BE PROTECTED AS INDICATED IN THE <br />CONFIRM CONFORMANCE WITH THE VISUAL DESIGN CONCEPT, PRIOR TO COMMENCING WORK. <br />A SET OF DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW IN AN EFFORT TO <br />ALL CALCULATIONS AND DRAWINGS SHALL BE PREPARED BY A MECHANICAL ENGINEER OR <br />"MATCHED" TO THE ADJACENT SURFACES. <br />DEPARTMENT FOR APPROVAL. A SET OF DRAWINGS SHALL ALSO BE SUBMITTED TO THE <br />FIRE SPRINKLER DRAWINGS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT AND FIRE <br />ARCHITECT FOR REVIEW IN AN EFFORT TO CONFIRM CONFORMANCE WITH THE VISUAL DESIGN <br />CONCEPT, PRIOR TO COMMENCING WORK. <br />ALL SPRINKLER HEADS SHALL BE CONCEALED TYPE WITH THE HEAD AND COVER PLATE FINISH <br />REQUIRED BY THE CITY/COUNTY FIRE MARSHALL AND/OR GOVERNING AGENCIES. <br />ANY CHANGES REQUIRED TO ACCOMMODATE INSTALLATION OF THE WORK, SHALL ALSO BE <br />SUBMITTED TO THE ARCHITECT FOR APPROVAL. <br />THE FIRE SPRINKLER SYSTEM DESIGN AND INSTALLATION SHALL MEET ALL REQUIREMENTS AS <br />ALL EQUIPMENT SHALL COMPLY WITH STATE ENERGY REQUIREMENTS FOR EFFICIENCY. ALL <br />DUCTWORK "R" VALUE SHALL ALSO COMPLY WITH STATE ENERGY REQUIREMENTS. <br />15.1.3 MATERIALS <br />15.1.4 CALCULATIONS AND DRAWINGS <br />AS REQUIRED BY THE LOCAL GOVERNING AGENCY. <br />15.2.1 <br />15.2 <br />STANDARDS <br />FIRE SPRINKLERS (IF REQUIRED) <br />NOTES, SHALL BE CONSTRUED TO ALLOW ANT WORK NOT CONFORMING TO ALL APPLICABLE <br />CODES, RULES, REGULATIONS, OR AMENDMENTS. <br />ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH ALL REQUIREMENTS OF ALL <br />LEGALLY CONSTITUTED PUBLIC AUTHORITIES HAVING JURISDICTION INCLUDING ALL COUNTY AND <br />STATE ORDINANCES. NOTHING IN THE CONSTRUCTION DOCUMENTS, INCLUDING THESE GENERAL <br />DATE LINES WITHIN FRONT PORCH ENTRY WALK. <br />CLEANOUTS IN LEAST VISIBLE AREAS. DO NOT LOCATE SOIL LINE CLEANOUTS OR CONSOLI- <br />PROVIDE COLD WATER LINE TO REFRIGERATOR SPACE IN RECESSED BOX OR IN CABINET <br />IMMEDIATELY ADJACENT TO REFRIGERATOR SPACE. <br />ALL SOIL, WASTE, AND VENTING PIPING SHALL BE APPROVED ABS PER LOCAL CODE UNLESS <br />DOMESTIC WATER PIPING SYSTEM SHALL BE DESIGNED AND INSTALLED WITH ALL WATER <br />SUPPLY LINES BEING COPPER (TYPE L BELOW SLAB, AND TYPE M ABOVE SLAB.) NO PIPE <br />FITTINGS SHALL OCCUR BELOW SLAB. <br />HIGH STABLE PLATFORM. <br />BUILDING. WHEN LOCATED IN GARAGE, WATER HEATER SHALL BE INSTALLED ON A MINIMUM 18" <br />VERTICAL DIMENSIONS. WATER HEATER SHALL ALSO BE PROVIDED WITH A PRESSURE/ <br />TEMPERATURE RELIEF VALVE AND PAN AND DRAIN LINE PIPED TO THE EXTERIOR OF THE <br />WATER HEATING SYSTEM (WATER HEATER) SHALL BE PROVIDED WITH SEISMIC RESTRAINTS. <br />STRAPPING SHALL BE AT POINTS WITHIN THE UPPER ONE-THIRD AND LOWER ONE-THIRD OF IT'S <br />DOMESTIC GAS PIPING SYSTEM SHALL BE DESIGNED AND INSTALLED TO PROVIDE SERVICE TO <br />GAS-FIRED EQUIPMENT, INCLUDING WATER HEATER. FIREPLACES, FORCED AIR UNITS, KITCHEN <br />APPLIANCES, POOL EQUIPMENT, ETC. <br />15.2.2 DRAWINGS <br />15.3 <br />15.3.1 <br />PLUMBING <br />STANDARDS <br />15.3.2 INSTALLATION <br />BUILDING CODE (CURRENT EDITION). <br />ALL PENETRATIONS OF FIRE ASSEMBLIES SHALL MEET THE REQUIREMENTS OF THE CALIFORNIA <br />TION DOCUMENTS, AND AS REQUIRED BY THE CALIFORNIA MECHANICAL CODE (CURRENT EDITION). <br />FROM THE NORMAL VEHICULAR PATH, SHALL BE PROTECTED AS INDICATED IN THE CONSTRUC- <br />ALL FUEL BURNING EQUIPMENT LOCATED IN PARKING AREAS AND SUBJECT TO MECHANICAL DAMAGE <br />ELASTOMERIC MEMBRANE MATERIALS SHALL BE PROVIDED AT ALL PENETRATIONS OF THE <br />WATER-RESISTIVE MEMBRANE AT EXTERIOR WALLS. <br />OTHERWISE. ALL PIPING SHALL BE SIZED AS REQUIRED BY SUBJECT GOVERNING AGENCY. <br />PROVIDE CLEAN OUTS AT ENDS OF ALL LINES AND WHERE REQUIRED BY CODES. LOCATE <br />WINDOWS. <br />ALL VENTS SHALL LEAD TO OUTSIDE AIR, AND WHERE POSSIBLE, LOCATE ALL ROOF VENTS <br />COMBUSTION AIR SHALL BE PROVIDED WITH REQUIRED VENTILATION AREA OF 2 SQUARE <br />INCHES PER 1000/BTU, WITH 200 SQUARE INCHES, MINIMUM (VERIFY WITH LOCAL GOVERNING <br />AGENCY.). COMBUSTION AIR OPENINGS SHALL BE COVERED WITH 1/4" NON-CORROSIVE MESH <br />SCREEN. <br />USING SAME CRITERIA AS UNDER FLOOR AREAS. <br />DIMENSION. ENCLOSED JOIST BAYS OF DECKS EXPOSED TO EXTERIOR SHALL BE VENTED <br />SHALL BE COVERED WITH CORROSION RESISTANT WIRE MESH WITH MESH OPENINGS OF 1/4" <br />PROVIDE CROSS VENTILATION. THE REQUIRED AREA OF SUCH OPENINGS SHALL BE APPROX- <br />IMATELY EQUALLY DISTRIBUTED ALONG THE LENGTH OF AT LEAST TWO OPPOSITE SIDES. THEY <br />ENCLOSED UNDER-FLOOR AREAS SHALL BE VENTILATED BY AN APPROVED MECHANICAL <br />MEANS OR BY OPENINGS IN EXTERIOR FOUNDATION WALLS. SUCH OPENINGS SHALL HAVE A <br />NET AREA OF NOT LESS THAN 1 SQUARE FOOT FOR EACH 150 SQUARE FEET OF UNDER-FLOOR <br />AREA. OPENINGS SHALL BE LOCATED AS CLOSE TO CORNERS AS PRACTICAL AND SHALL <br />ALL UTILITY METER REQUIREMENTS SHALL BE VERIFIED WITH GOVERNING UTILITY COMPANY. <br />MENT, IN AN EFFORT TO MEET ALL APPLICABLE CODE REQUIREMENTS. <br />PROVIDE FOR ALL ENERGY REQUIREMENTS AS THEY PERTAIN TO ALL MATERIAL AND EQUIP- <br />NO ALTERATIONS TO THE STRUCTURAL FRAME, DIAPHRAGMS, CONNECTIONS OR SHEAR PANELS, <br />SHALL BE MADE WHICH WOULD COMPROMISE THE DESIGNED STRUCTURAL INTEGRITY OF SUCH <br />ELEMENTS, WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF <br />RECORD. <br />PROVIDE RECESSED FAUCET BOX AT CLOTHES WASHER. PROVIDE PAN AND DRAIN LINE TO <br />PROVIDE SOLID BACKING FOR SECURING ALL FIXTURES. ALL FIXTURES SHALL BE SET LEVEL. <br />AIR UNIT LOCATIONS. <br />PROVIDE CONDENSATE LINE AT EACH FORCED AIR UNIT LOCATION. PROVIDE PRIMARY AND <br />SECONDARY CONDENSATE LINE TO AN APPROVED DRAINAGE RECEPTACLE AT ATTIC FORCED <br />ANTI-SIPHON HOSE BIBBS SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST APPLIC- <br />ABLE CODES AND REGULATIONS. PROVIDE 3/4" TEE FOR IRRIGATION AT MAIN SHUT-OFF. <br />SUBMITTED TO THE ARCHITECT FOR APPROVAL. <br />ANY CHANGES REQUIRED TO ACCOMMODATE INSTALLATION OF THE WORK, SHALL ALSO BE <br />CONFIRM CONFORMANCE WITH THE VISUAL DESIGN CONCEPT, PRIOR TO COMMENCING WORK. <br />A SET OF DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW IN AN EFFORT TO <br />THE LOCAL GOVERNING AGENCY. <br />ALL CALCULATIONS AND DRAWINGS SHALL BE PREPARED AND SUBMITTED AS REQUIRED BY <br />OUTSIDE AT WOOD FLOOR INSTALLATIONS. <br />15.3.3 VENTILATION <br />THE REAR SIDE OF ROOF RIDGES. ALL VENTS SHALL TERMINATE A MINIMUM OF 3'-0" FROM <br />15.3.4 CALCULATIONS AND DRAWINGS <br />WATER CLOSET SHALL BE 1.6 GAL. PER FLUSH. MANUFACTURER AND MODEL SHALL BE AS <br />SELECTED BY OWNER/CLIENT. <br />ENCLOSURES SHALL BE A MINIMUM OF 60" HIGH ABOVE THE DRAIN. WALLS SHALL BE A MINIMUM <br />CLIENT. SIZE AS INDICATED IN CONSTRUCTION DOCUMENTS. TEMPERED. SHATTERPROOF GLASS <br />TUB/SHOWER COMBINATION MANUFACTURER AND MODEL SHALL BE AS SELECTED BY OWNER/ <br />INFORMATION. <br />BATHTUB MANUFACTURER AND MODEL SHALL BE AS SELECTED BY OWNER/CLIENT. SIZE AS <br />INDICATED IN CONSTRUCTION DOCUMENTS. <br />OF 60" HIGH ABOVE THE DRAIN. REFER TO CONSTRUCTION DOCUMENTS FOR ADDITIONAL HEIGHT <br />INFORMATION. <br />CABINETS SHALL HAVE MIRRORED DOOR, RECESS MOUNTED, WITH TOP AT 72" A.F.F.+/-. <br />MEDICINE CABINETS MANUFACTURER AND MODEL SHALL BE AS SELECTED BY OWNER/CLIENT. <br />SHOWER ENCLOSURE MANUFACTURER AND MODEL SHALL BE AS SELECT BY OWNER/CLIENT. <br />SIZE AS INDICATED IN CONSTRUCTION DOCUMENTS WITH TEMPERED, SHATTERPROOF GLASS <br />ENCLOSURE AT A HEIGHT OF 60" MINIMUM ABOVE THE DRAIN. WALLS SHALL BE A MINIMUM OF <br />60" HIGH ABOVE THE DRAIN. REFER TO CONSTRUCTION DOCUMENTS FOR ADDITIONAL HEIGHT <br />OF BACKSPLASH, WITH A MINIMUM OF TWO CLIPS AT THE TOP. <br />MIRRORS SHALL BE AS SHOWN ON INTERIOR ELEVATION SHEETS, AND SET IN "J" METAL AT TOP <br />INDICATED IN CONSTRUCTION DOCUMENTS. <br />ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANU- <br />FACTURER'S PRINTED INSTALLATION INSTRUCTIONS. WORK SHALL BE SET PLUMB, LEVEL AND <br />FIXTURES AND APPLIANCES SHALL BE AS SELECTED BY OWNER/CLIENT. SIZE AS <br />10.6 BATHROOM AND PLUMBING ACCESSORIES <br />IT INTO THE PORTIONS OF THE WORK. BACKING PLATES, BLOCKS, ANCHORS, AND FASTENERS <br />SET IN IT'S PROPER PLACE, FASTENING IT, BUILDING IT IN, CONNECTING IT, OR INCORPORATING <br />TRUE TO LINE, AND SHALL PRESENT A NEAT AND FINISHED APPEARANCE. EACH ITEM SHALL BE <br />10.7 FIXTURES AND APPLIANCES <br />SHALL BE PROVIDED AS REQUIRED FOR INSTALLING AND ANCHORING THE SPECIFIC EQUIPMENT <br />ITEMS. <br />DRAWINGS AND AS NECESSARY. <br />DRAINS SHALL BE AS SIZED AS REQUIRED. PROVIDE OVERFLOWS AS INDICATED ON <br />ABOVE-COUNTER OUTLETS (AT 32" HIGH COUNTERTOPS) SHALL BE SET AT 42" A.F.F.. <br />INSTALLATION HEIGHTS (UNLESS NOTED OTHERWISE)16.3 <br />SHALL BE MADE WHICH WOULD COMPROMISE THE DESIGNED STRUCTURAL INTEGRITY OF SUCH <br />PUSH BUTTONS SHALL BE SET AT + 42" A.F.F.. <br />STAIRWAY STEP LIGHTS SHALL BE SET AT +8" ABOVE THE SKIRT BOARD. <br />THERMOSTATS SHALL BE SET AT + 60" A.F.F.. <br />WALL OUTLETS AT LAUNDRY ROOM SHALL BE SET AT +48" A.F.F.. <br />ALL SMOKE DETECTORS SHALL BE LOCATED PER C.B.C. SECTION 907.2.11.2 <br />SHALL BE SET AT + 46" A.F.F.. <br />DOOR CHIMES SHALL BE SET AT + 88" A.F.F.. <br />ELEMENTS, WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. <br />NO ALTERATIONS TO THE STRUCTURAL FRAME, DIAPHRAGMS, CONNECTIONS OR SHEAR PANELS, <br />TYPICAL WALL SWITCHES SHALL BE SET AT + 42" A.F.F.. <br />ABOVE-COUNTER OUTLETS (AT 36" HIGH COUNTERTOPS) SHALL BE SET AT 46" A.F.F.. <br />ABOVE-COUNTER OUTLETS AT BREAKFRONT LINEN OR OTHER MISCELLANEOUS COUNTERS <br />TYPICAL WALL OUTLETS SHALL BE SET AT + 14" A.F.F.. <br />MEET ALL APPLICABLE DISABLED/ACCESSIBILITY REQUIREMENTS. <br />ALL HEIGHTS ARE GIVEN TO THE CENTERLINE OF THE FIXTURE OR OUTLET. HEIGHTS SHALL <br />INSTALLATION16.2 <br />SHALL BE CONSTRUED TO ALLOW ANY WORK NOT CONFORMING TO ALL APPLICABLE CODES, <br />PROOF. <br />MENTS DICTATE THAT THE ADDRESS NUMBER ITSELF, BE ILLUMINATED. <br />PROVIDE LOW VOLTAGE STUB-OUT FOR HOUSE ADDRESS NUMBERS, IF LOCAL CODE REQUIRE- <br />THE COMPLETE ELECTRICAL SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH THE PRES- <br />ENTLY ADOPTED EDITION OF THE CALIFORNIA ELECTRICAL CODE (CURRENT EDITION). <br />ALL "SWITCHED" OUTLETS SHALL BE 1/2 HOT. <br />PROVIDE SEPARATE CIRCUITS EACH FOR DISHWASHER, GARBAGE DISPOSAL, REFRIGERATOR, <br />WASHER, DRYER, FORCED AIR UNIT, AND MICROWAVE OVEN. <br />ALL EQUIPMENT INSTALLED OUTDOORS AND EXPOSED TO THE WEATHER, SHALL BE WEATHER- <br />WATER-RESISTIVE MEMBRANE AT EXTERIOR WALLS. <br />ELASTOMERIC MEMBRANE MATERIALS SHALL BE PROVIDED AT ALL PENETRATIONS OF THE <br />UATION BY THE SERVICING UTILITY COMPANY. <br />TRACTOR FROM EACH BUILDING MAIN DISCONNECT TO THE EXTERIOR BUILDING LINE FOR CON- <br />RULES, REGULATIONS, OR AMENDMENTS. <br />ALL MATERIAL AND EQUIPMENT SHALL BE NEW AND OF THE SAME MANUFACTURER FOR EACH <br />CLASS OR GROUP OF EQUIPMENT. MATERIALS SHALL BE LISTED AND APPROVED BY UNDER- <br />WRITER'S LABORATORIES, INC. (U.L.) AND SHALL BEAR THE INSPECTION LABEL WHERE SUBJECT <br />TO SUCH APPROVAL. <br />AS DESIGNATED BY THE SERVICE UTILITY, AND SHALL BE PROVIDED BY THE ELECTRICAL CON- <br />TIONS TO THE "LINE SIDE" OF ALL BUILDING MAIN DISCONNECTS. RACEWAYS SHALL BE SIZED <br />ARY SERVICE RACEWAYS AND CONDUCTORS, INCLUDING TRANSFORMERS, PADS, AND CONNEC- <br />THE SERVICING UTILITY COMPANY SHALL PROVIDE AND INSTALL ALL PRIMARY AND SECOND- <br />JUNCTION BOXES, TEMPORARY POWER, SUB-PANELS, CONDUIT, ETC.. ALL WORK, MATERIALS, <br />HAVING JURISDICTION, INCLUDING ALL COUNTY AND STATE ORDINANCES. ALL MATERIAL, <br />ETC., SHALL COMPLY WITH ALL REQUIREMENTS OF ALL LEGALLY CONSTITUTED AUTHORITIES <br />INSTALLATION REQUIREMENTS AND LIMITATIONS, SHALL BE VERIFIED AT ALL FIRE AND SOUND <br />ASSEMBLIES. NOTHING IN THE CONSTRUCTION DOCUMENTS, INCLUDING THESE GENERAL NOTES, <br />ELECTRICAL <br />STANDARDS16.1 <br />DIVISION 16 - <br />FIXTURES, APPLIANCES, WIRING, SWITCHES, OUTLETS, TELEVISION JACKS, SERVICES, GROUNDS, <br />ACCORDING TO THE BEST PRACTICES OF THE TRADE AND INCLUDING, BUT NOT LIMITED TO: <br />INSTALLATION OF COMPLETE ELECTRICAL SYSTEM SHALL ALLOW PROPER OPERATION <br />FOLLOWED FOR ALL MATERIALS PLACED WITHIN OR IN PROXIMITY OF SOIL AS NECESSARY. <br />ALL ELECTRICAL SERVICES SHALL BE PLACED UNDERGROUND. IN REGARDS TO THE CORRO- <br />SIVE PROPERTIES OF SOIL, ALL RECOMMENDATIONS IN THE FINAL SOILS REPORT SHALL BE <br />LIGHT FIXTURES SHALL BE SET AT +84" A.F.F. WHERE DOORS ARE 8'-0" HIGH, AND +78" A.F.F. WHERE DOORS <br />ARE 6'-8" HIGH. <br />TYPICAL WALL OUTLETS IN GARAGES SHALL BE SET AT + 42" A.F.F. (U.N.O.). <br />PROVIDE APPROVED AUTOMATIC FIRE DAMPERS OR MINIMUM 26 GAUGE CORROSION RESIS- TANT METAL <br />MATERIAL WITH SEATED EDGES AT ALL DUCTWORK PENETRATING FIRE RATED WALLS, FLOORS OR CEILINGS <br />AS REQUIRED AND ALLOWED BY THE CALIFORNIA MECHANICAL CODE (CURRENT EDITION). ALL FAN SYSTEMS <br />EXHAUSTING AIR FROM THE BUILDING ENVELOPE TO THE OUTSIDE, SHALL BE PROVIDED WITH BACK DRAFT <br />DAMPERS. <br />(CURRENT EDITION). <br />ALL SECURITY OPENINGS (EXTERIOR DOORS, DOORS BETWEEN HOUSE AND GARAGE, WINDOWS, GARAGE <br />DOORS, AND THEIR HARDWARE SHALL CONFORM TO THE SECURITY PROVISIONS OF THE CALIFORNIA <br />BUILDING CODE (CURRENT EDITION), AND ALL APPLICABLE STATE AND AND LOCAL SECURITY ORDINANCES. <br />ALL FIXTURES, OUTLETS, RECEPTACLES, ETC., PENETRATING FIRE ASSEMBLIES SHALL BE RATED AND INSTALLED <br />TO MEET THE REQUIREMENTS OF THE CALIFORNIA BUILDING CODE (CURRENT EDITION). OUTLET BOXES ON <br />OPPOSITE SIDES OF FIRE ASSEMBLIES WALLS SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF AT LEAST 24".MECHANICALDIVISION 15 -