G E N E R A L C O N S T R U C T I O N R E Q U I R E M E N T S
<br />DIVISION 15 -
<br />32
<br />2
<br />
<br />N
<br />.
<br />
<br />H
<br />A
<br />R
<br />B
<br />O
<br />R
<br />
<br />
<br />B
<br />L
<br />V
<br />D
<br />.
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />3
<br />SHEET NUMBER
<br />2 0 2 4 0 1 0
<br />SHEET TITLE
<br />PROJECT NUMBER
<br />REVISIONS
<br />NO.DATE NO.DATE
<br />HANNOUCHE ARCHITECTS
<br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT
<br />AND OTHER PROPERTY RIGHTS INHERENT IN
<br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES,
<br />FIELD NOTES AND ASSOCIATED DOCUMENTS
<br />ARE INSTRUMENTS OF SERVICE AND ARE THE
<br />PROPERTY OF HANNOUCHE ARCHITECTS.
<br />ALL INFORMATION CONTAINED IN THESE DRAWINGS,
<br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED
<br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT
<br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED,
<br />OR USED OTHERWISE IN ANY FORM OR MANNER
<br />WHATSOEVER, WITHOUT FIRST OBTAINING THE
<br />EXPRESSED WRITTEN PERMISSION AND CONSENT
<br />OF HANNOUCHE ARCHITECTS.
<br />HANNOUCHE ARCHITECT c 2021
<br />HANNOUCHE
<br />ARCHITECTS
<br />949.261.2070
<br />SAMIR HANNOUCHE, ARCHITECT
<br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660
<br />May 9, 2025
<br />1 CORR
<br />12/10/24
<br />BLDG
<br />A CORR
<br />3/18/25
<br />OCFA
<br />2 CORR
<br />4/09/25
<br />BLDG
<br />DATE SIGNED2
<br />3 CORR
<br />5/09/25
<br />BLDG
<br />SPECIALTIESDIVISION 10 - MECHANICALDIVISION 15 -
<br />(C O N T I N U E D)
<br />MECHANICAL
<br />(CONTINUED)(CONTINUED)(CONTINUED)
<br />GCR-4
<br />GENERAL
<br />CONSTRUCTION
<br />REQUIREMENTS
<br />EQUIPMENTDIVISION 11 -
<br />SPECIAL EQUIPMENT11.1
<br />CALIFORNIA MECHANICAL CODE (CURRENT EDITION), AND THE FOLLOWING:
<br />ATTIC FORCED-AIR-UNITS (F.A.U.) SHALL COMPLY WITH REQUIREMENTS SET FORTH IN THE
<br />5.
<br />4.
<br />ALL EQUIPMENT CLOSETS SHALL BE SIZED TO PROVIDE 6" (MIN.) CLEARANCE FROM THE EQUIP-
<br />MENT UNIT AT THE FRONT, REAR AND SIDES, OR PER APPLICABLE CODES. VERTICAL FAN COIL
<br />UNIT CLEARANCES SHALL BE PER APPLICABLE CODES.
<br />3.
<br />2.
<br />ALL FUEL BURNING EQUIPMENT LOCATED IN GARAGES AND SUBJECT TO MECHANICAL DAM-
<br />CONSTRUCTION DOCUMENTS, AND AS REQUIRED BY THE CALIFORNIA MECHANICAL CODE.
<br />MECHANICAL CODE (CURRENT EDITION).
<br />BE PROVIDED FOR EQUIPMENT AS PER MANUFACTURER'S REQUIREMENTS AND THE CALIFORNIA
<br />FLUES, HIGH AND LOW COMBUSTION AIR VENTING, AND FRESH AIR DUCTING AND GRILLS, SHALL
<br />ALL PENETRATIONS OF FIRE ASSEMBLIES SHALL MEET THE REQUIREMENTS OF THE CALIFORNIA
<br />BUILDING CODE (CURRENT EDITION).
<br />ALL DUCTWORK SHALL BE CONSTRUCTED, INSTALLED, AND INSULATED PER REQUIREMENTS SET
<br />FORTH IN THE CALIFORNIA MECHANICAL CODE (CURRENT EDITION).
<br />ELEMENTS, WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD.
<br />SHALL BE MADE WHICH WOULD COMPROMISE THE DESIGNED STRUCTURAL INTEGRITY OF SUCH
<br />NO ALTERATIONS TO THE STRUCTURE FRAME, DIAPHRAGMS, CONNECTIONS OR SHEAR PANELS,
<br />JURISDICTION INCLUDING ALL COUNTY AND STATE ORDINANCES. NOTHING IN THE CONSTRUC-
<br />COMPLY WITH ALL REQUIREMENTS OF ALL LEGALLY CONSTITUTED PUBLIC AUTHORITIES HAVING
<br />OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS STANDARDS, AND SHALL
<br />ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH LATEST AMERICAN SOCIETY
<br />WORK NOT CONFORMING TO ALL APPLICABLE CODES, RULES, REGULATIONS, OR AMENDMENTS.
<br />TION DOCUMENTS, INCLUDING THESE GENERAL NOTES, SHALL BE CONSTRUED TO ALLOW ANY
<br />NOT A PART OF THESE GENERAL NOTES.
<br />ALL CLEARANCE AND FIT REQUIREMENTS SHALL BE VERIFIED BY TAKING FIELD MEASURE-
<br />MENTS. PROPER FIT AND ATTACHMENTS OF ALL PARTS IS REQUIRED.
<br />DIVISION 12 - FURNISHINGS
<br />UNITS (HORIZONTAL OR VERTICAL).
<br />ROOF/ATTIC FRAMING, INCLUDING PREFABRICATED TRUSSES, SHALL BE DESIGNED IN SUCH A
<br />MECHANICAL CODE (CURRENT EDITION).
<br />WATER-RESISTIVE MEMBRANE AT EXTERIOR WALLS.
<br />ELASTOMERIC MEMBRANE MATERIALS SHALL BE PROVIDED AT ALL PENETRATIONS OF THE
<br />FORCED-AIR-UNITS SHALL BE INSTALLED IN ATTIC OR ON 16" HIGH PLATFORM AT "CONDI-
<br />TIONED SPACE" AREA OR ON 18" HIGH PLATFORM AT GARAGE, AS REQUIRED BY THE CALIFORNIA
<br />DIVISION 13 -
<br />13.1 BUILDING SECURITY
<br />SPECIAL CONSTRUCTION
<br />DIVISION 14 - CONVEYING SYSTEMS
<br />NOT A PART OF THESE GENERAL NOTES.
<br />15.1 HEATING AND AIR CONDITIONING
<br />15.1.1 STANDARDS
<br />15.1.2 INSTALLATION
<br />MANNER AS TO PROVIDE ALL REQUIRED CLEARANCES FOR ATTIC-MOUNTED FORCED-AIR-
<br />1.PROVIDE REQUIRED CLEARANCES FOR DUCT WORK AND TO COMBUSTIBLE MATERIALS.
<br />DOOR AND PASSAGEWAY, CONTINUOUS TO THE F.A.U. AND IT'S CONTROLS. A 22" X 30"
<br />PROVIDE MINIMUM 30" X 30" ATTIC ACCESS OPENING WITH FULLY WEATHER-STRIPPED
<br />LARGEST PIECE OF F.A.U. EQUIPMENT CAN BE REMOVED THROUGH THE OPENING.
<br />ACCESS OPENING WITH FULLY WEATHER-STRIPPED DOOR MAY BE USED PROVIDED THE
<br />PROVIDE AN UNOBSTRUCTED CONTINUOUS SOLID FLOOR PASSAGEWAY NOT LESS THAN 24"
<br />WIDE, NOT TO EXCEED 20' FROM THE ATTIC ACCESS OPENING TO THE F.A.U..
<br />PROVIDE A LEVEL WORKING PLATFORM 30" DEEP IN FRONT OF THE ENTIRE FIREBOX SIDE
<br />OF THE F.A.U., AND TO ALL SERVICEABLE CONTROLS, FILTERS, ETC.
<br />PROVIDE A PERMANENT ELECTRICAL OUTLET AND SWITCHED LIGHT FIXTURE.
<br />AGE FROM THE NORMAL VEHICULAR PATH, SHALL BE PROTECTED AS INDICATED IN THE
<br />CONFIRM CONFORMANCE WITH THE VISUAL DESIGN CONCEPT, PRIOR TO COMMENCING WORK.
<br />A SET OF DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW IN AN EFFORT TO
<br />ALL CALCULATIONS AND DRAWINGS SHALL BE PREPARED BY A MECHANICAL ENGINEER OR
<br />"MATCHED" TO THE ADJACENT SURFACES.
<br />DEPARTMENT FOR APPROVAL. A SET OF DRAWINGS SHALL ALSO BE SUBMITTED TO THE
<br />FIRE SPRINKLER DRAWINGS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT AND FIRE
<br />ARCHITECT FOR REVIEW IN AN EFFORT TO CONFIRM CONFORMANCE WITH THE VISUAL DESIGN
<br />CONCEPT, PRIOR TO COMMENCING WORK.
<br />ALL SPRINKLER HEADS SHALL BE CONCEALED TYPE WITH THE HEAD AND COVER PLATE FINISH
<br />REQUIRED BY THE CITY/COUNTY FIRE MARSHALL AND/OR GOVERNING AGENCIES.
<br />ANY CHANGES REQUIRED TO ACCOMMODATE INSTALLATION OF THE WORK, SHALL ALSO BE
<br />SUBMITTED TO THE ARCHITECT FOR APPROVAL.
<br />THE FIRE SPRINKLER SYSTEM DESIGN AND INSTALLATION SHALL MEET ALL REQUIREMENTS AS
<br />ALL EQUIPMENT SHALL COMPLY WITH STATE ENERGY REQUIREMENTS FOR EFFICIENCY. ALL
<br />DUCTWORK "R" VALUE SHALL ALSO COMPLY WITH STATE ENERGY REQUIREMENTS.
<br />15.1.3 MATERIALS
<br />15.1.4 CALCULATIONS AND DRAWINGS
<br />AS REQUIRED BY THE LOCAL GOVERNING AGENCY.
<br />15.2.1
<br />15.2
<br />STANDARDS
<br />FIRE SPRINKLERS (IF REQUIRED)
<br />NOTES, SHALL BE CONSTRUED TO ALLOW ANT WORK NOT CONFORMING TO ALL APPLICABLE
<br />CODES, RULES, REGULATIONS, OR AMENDMENTS.
<br />ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH ALL REQUIREMENTS OF ALL
<br />LEGALLY CONSTITUTED PUBLIC AUTHORITIES HAVING JURISDICTION INCLUDING ALL COUNTY AND
<br />STATE ORDINANCES. NOTHING IN THE CONSTRUCTION DOCUMENTS, INCLUDING THESE GENERAL
<br />DATE LINES WITHIN FRONT PORCH ENTRY WALK.
<br />CLEANOUTS IN LEAST VISIBLE AREAS. DO NOT LOCATE SOIL LINE CLEANOUTS OR CONSOLI-
<br />PROVIDE COLD WATER LINE TO REFRIGERATOR SPACE IN RECESSED BOX OR IN CABINET
<br />IMMEDIATELY ADJACENT TO REFRIGERATOR SPACE.
<br />ALL SOIL, WASTE, AND VENTING PIPING SHALL BE APPROVED ABS PER LOCAL CODE UNLESS
<br />DOMESTIC WATER PIPING SYSTEM SHALL BE DESIGNED AND INSTALLED WITH ALL WATER
<br />SUPPLY LINES BEING COPPER (TYPE L BELOW SLAB, AND TYPE M ABOVE SLAB.) NO PIPE
<br />FITTINGS SHALL OCCUR BELOW SLAB.
<br />HIGH STABLE PLATFORM.
<br />BUILDING. WHEN LOCATED IN GARAGE, WATER HEATER SHALL BE INSTALLED ON A MINIMUM 18"
<br />VERTICAL DIMENSIONS. WATER HEATER SHALL ALSO BE PROVIDED WITH A PRESSURE/
<br />TEMPERATURE RELIEF VALVE AND PAN AND DRAIN LINE PIPED TO THE EXTERIOR OF THE
<br />WATER HEATING SYSTEM (WATER HEATER) SHALL BE PROVIDED WITH SEISMIC RESTRAINTS.
<br />STRAPPING SHALL BE AT POINTS WITHIN THE UPPER ONE-THIRD AND LOWER ONE-THIRD OF IT'S
<br />DOMESTIC GAS PIPING SYSTEM SHALL BE DESIGNED AND INSTALLED TO PROVIDE SERVICE TO
<br />GAS-FIRED EQUIPMENT, INCLUDING WATER HEATER. FIREPLACES, FORCED AIR UNITS, KITCHEN
<br />APPLIANCES, POOL EQUIPMENT, ETC.
<br />15.2.2 DRAWINGS
<br />15.3
<br />15.3.1
<br />PLUMBING
<br />STANDARDS
<br />15.3.2 INSTALLATION
<br />BUILDING CODE (CURRENT EDITION).
<br />ALL PENETRATIONS OF FIRE ASSEMBLIES SHALL MEET THE REQUIREMENTS OF THE CALIFORNIA
<br />TION DOCUMENTS, AND AS REQUIRED BY THE CALIFORNIA MECHANICAL CODE (CURRENT EDITION).
<br />FROM THE NORMAL VEHICULAR PATH, SHALL BE PROTECTED AS INDICATED IN THE CONSTRUC-
<br />ALL FUEL BURNING EQUIPMENT LOCATED IN PARKING AREAS AND SUBJECT TO MECHANICAL DAMAGE
<br />ELASTOMERIC MEMBRANE MATERIALS SHALL BE PROVIDED AT ALL PENETRATIONS OF THE
<br />WATER-RESISTIVE MEMBRANE AT EXTERIOR WALLS.
<br />OTHERWISE. ALL PIPING SHALL BE SIZED AS REQUIRED BY SUBJECT GOVERNING AGENCY.
<br />PROVIDE CLEAN OUTS AT ENDS OF ALL LINES AND WHERE REQUIRED BY CODES. LOCATE
<br />WINDOWS.
<br />ALL VENTS SHALL LEAD TO OUTSIDE AIR, AND WHERE POSSIBLE, LOCATE ALL ROOF VENTS
<br />COMBUSTION AIR SHALL BE PROVIDED WITH REQUIRED VENTILATION AREA OF 2 SQUARE
<br />INCHES PER 1000/BTU, WITH 200 SQUARE INCHES, MINIMUM (VERIFY WITH LOCAL GOVERNING
<br />AGENCY.). COMBUSTION AIR OPENINGS SHALL BE COVERED WITH 1/4" NON-CORROSIVE MESH
<br />SCREEN.
<br />USING SAME CRITERIA AS UNDER FLOOR AREAS.
<br />DIMENSION. ENCLOSED JOIST BAYS OF DECKS EXPOSED TO EXTERIOR SHALL BE VENTED
<br />SHALL BE COVERED WITH CORROSION RESISTANT WIRE MESH WITH MESH OPENINGS OF 1/4"
<br />PROVIDE CROSS VENTILATION. THE REQUIRED AREA OF SUCH OPENINGS SHALL BE APPROX-
<br />IMATELY EQUALLY DISTRIBUTED ALONG THE LENGTH OF AT LEAST TWO OPPOSITE SIDES. THEY
<br />ENCLOSED UNDER-FLOOR AREAS SHALL BE VENTILATED BY AN APPROVED MECHANICAL
<br />MEANS OR BY OPENINGS IN EXTERIOR FOUNDATION WALLS. SUCH OPENINGS SHALL HAVE A
<br />NET AREA OF NOT LESS THAN 1 SQUARE FOOT FOR EACH 150 SQUARE FEET OF UNDER-FLOOR
<br />AREA. OPENINGS SHALL BE LOCATED AS CLOSE TO CORNERS AS PRACTICAL AND SHALL
<br />ALL UTILITY METER REQUIREMENTS SHALL BE VERIFIED WITH GOVERNING UTILITY COMPANY.
<br />MENT, IN AN EFFORT TO MEET ALL APPLICABLE CODE REQUIREMENTS.
<br />PROVIDE FOR ALL ENERGY REQUIREMENTS AS THEY PERTAIN TO ALL MATERIAL AND EQUIP-
<br />NO ALTERATIONS TO THE STRUCTURAL FRAME, DIAPHRAGMS, CONNECTIONS OR SHEAR PANELS,
<br />SHALL BE MADE WHICH WOULD COMPROMISE THE DESIGNED STRUCTURAL INTEGRITY OF SUCH
<br />ELEMENTS, WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF
<br />RECORD.
<br />PROVIDE RECESSED FAUCET BOX AT CLOTHES WASHER. PROVIDE PAN AND DRAIN LINE TO
<br />PROVIDE SOLID BACKING FOR SECURING ALL FIXTURES. ALL FIXTURES SHALL BE SET LEVEL.
<br />AIR UNIT LOCATIONS.
<br />PROVIDE CONDENSATE LINE AT EACH FORCED AIR UNIT LOCATION. PROVIDE PRIMARY AND
<br />SECONDARY CONDENSATE LINE TO AN APPROVED DRAINAGE RECEPTACLE AT ATTIC FORCED
<br />ANTI-SIPHON HOSE BIBBS SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST APPLIC-
<br />ABLE CODES AND REGULATIONS. PROVIDE 3/4" TEE FOR IRRIGATION AT MAIN SHUT-OFF.
<br />SUBMITTED TO THE ARCHITECT FOR APPROVAL.
<br />ANY CHANGES REQUIRED TO ACCOMMODATE INSTALLATION OF THE WORK, SHALL ALSO BE
<br />CONFIRM CONFORMANCE WITH THE VISUAL DESIGN CONCEPT, PRIOR TO COMMENCING WORK.
<br />A SET OF DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW IN AN EFFORT TO
<br />THE LOCAL GOVERNING AGENCY.
<br />ALL CALCULATIONS AND DRAWINGS SHALL BE PREPARED AND SUBMITTED AS REQUIRED BY
<br />OUTSIDE AT WOOD FLOOR INSTALLATIONS.
<br />15.3.3 VENTILATION
<br />THE REAR SIDE OF ROOF RIDGES. ALL VENTS SHALL TERMINATE A MINIMUM OF 3'-0" FROM
<br />15.3.4 CALCULATIONS AND DRAWINGS
<br />WATER CLOSET SHALL BE 1.6 GAL. PER FLUSH. MANUFACTURER AND MODEL SHALL BE AS
<br />SELECTED BY OWNER/CLIENT.
<br />ENCLOSURES SHALL BE A MINIMUM OF 60" HIGH ABOVE THE DRAIN. WALLS SHALL BE A MINIMUM
<br />CLIENT. SIZE AS INDICATED IN CONSTRUCTION DOCUMENTS. TEMPERED. SHATTERPROOF GLASS
<br />TUB/SHOWER COMBINATION MANUFACTURER AND MODEL SHALL BE AS SELECTED BY OWNER/
<br />INFORMATION.
<br />BATHTUB MANUFACTURER AND MODEL SHALL BE AS SELECTED BY OWNER/CLIENT. SIZE AS
<br />INDICATED IN CONSTRUCTION DOCUMENTS.
<br />OF 60" HIGH ABOVE THE DRAIN. REFER TO CONSTRUCTION DOCUMENTS FOR ADDITIONAL HEIGHT
<br />INFORMATION.
<br />CABINETS SHALL HAVE MIRRORED DOOR, RECESS MOUNTED, WITH TOP AT 72" A.F.F.+/-.
<br />MEDICINE CABINETS MANUFACTURER AND MODEL SHALL BE AS SELECTED BY OWNER/CLIENT.
<br />SHOWER ENCLOSURE MANUFACTURER AND MODEL SHALL BE AS SELECT BY OWNER/CLIENT.
<br />SIZE AS INDICATED IN CONSTRUCTION DOCUMENTS WITH TEMPERED, SHATTERPROOF GLASS
<br />ENCLOSURE AT A HEIGHT OF 60" MINIMUM ABOVE THE DRAIN. WALLS SHALL BE A MINIMUM OF
<br />60" HIGH ABOVE THE DRAIN. REFER TO CONSTRUCTION DOCUMENTS FOR ADDITIONAL HEIGHT
<br />OF BACKSPLASH, WITH A MINIMUM OF TWO CLIPS AT THE TOP.
<br />MIRRORS SHALL BE AS SHOWN ON INTERIOR ELEVATION SHEETS, AND SET IN "J" METAL AT TOP
<br />INDICATED IN CONSTRUCTION DOCUMENTS.
<br />ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANU-
<br />FACTURER'S PRINTED INSTALLATION INSTRUCTIONS. WORK SHALL BE SET PLUMB, LEVEL AND
<br />FIXTURES AND APPLIANCES SHALL BE AS SELECTED BY OWNER/CLIENT. SIZE AS
<br />10.6 BATHROOM AND PLUMBING ACCESSORIES
<br />IT INTO THE PORTIONS OF THE WORK. BACKING PLATES, BLOCKS, ANCHORS, AND FASTENERS
<br />SET IN IT'S PROPER PLACE, FASTENING IT, BUILDING IT IN, CONNECTING IT, OR INCORPORATING
<br />TRUE TO LINE, AND SHALL PRESENT A NEAT AND FINISHED APPEARANCE. EACH ITEM SHALL BE
<br />10.7 FIXTURES AND APPLIANCES
<br />SHALL BE PROVIDED AS REQUIRED FOR INSTALLING AND ANCHORING THE SPECIFIC EQUIPMENT
<br />ITEMS.
<br />DRAWINGS AND AS NECESSARY.
<br />DRAINS SHALL BE AS SIZED AS REQUIRED. PROVIDE OVERFLOWS AS INDICATED ON
<br />ABOVE-COUNTER OUTLETS (AT 32" HIGH COUNTERTOPS) SHALL BE SET AT 42" A.F.F..
<br />INSTALLATION HEIGHTS (UNLESS NOTED OTHERWISE)16.3
<br />SHALL BE MADE WHICH WOULD COMPROMISE THE DESIGNED STRUCTURAL INTEGRITY OF SUCH
<br />PUSH BUTTONS SHALL BE SET AT + 42" A.F.F..
<br />STAIRWAY STEP LIGHTS SHALL BE SET AT +8" ABOVE THE SKIRT BOARD.
<br />THERMOSTATS SHALL BE SET AT + 60" A.F.F..
<br />WALL OUTLETS AT LAUNDRY ROOM SHALL BE SET AT +48" A.F.F..
<br />ALL SMOKE DETECTORS SHALL BE LOCATED PER C.B.C. SECTION 907.2.11.2
<br />SHALL BE SET AT + 46" A.F.F..
<br />DOOR CHIMES SHALL BE SET AT + 88" A.F.F..
<br />ELEMENTS, WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD.
<br />NO ALTERATIONS TO THE STRUCTURAL FRAME, DIAPHRAGMS, CONNECTIONS OR SHEAR PANELS,
<br />TYPICAL WALL SWITCHES SHALL BE SET AT + 42" A.F.F..
<br />ABOVE-COUNTER OUTLETS (AT 36" HIGH COUNTERTOPS) SHALL BE SET AT 46" A.F.F..
<br />ABOVE-COUNTER OUTLETS AT BREAKFRONT LINEN OR OTHER MISCELLANEOUS COUNTERS
<br />TYPICAL WALL OUTLETS SHALL BE SET AT + 14" A.F.F..
<br />MEET ALL APPLICABLE DISABLED/ACCESSIBILITY REQUIREMENTS.
<br />ALL HEIGHTS ARE GIVEN TO THE CENTERLINE OF THE FIXTURE OR OUTLET. HEIGHTS SHALL
<br />INSTALLATION16.2
<br />SHALL BE CONSTRUED TO ALLOW ANY WORK NOT CONFORMING TO ALL APPLICABLE CODES,
<br />PROOF.
<br />MENTS DICTATE THAT THE ADDRESS NUMBER ITSELF, BE ILLUMINATED.
<br />PROVIDE LOW VOLTAGE STUB-OUT FOR HOUSE ADDRESS NUMBERS, IF LOCAL CODE REQUIRE-
<br />THE COMPLETE ELECTRICAL SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH THE PRES-
<br />ENTLY ADOPTED EDITION OF THE CALIFORNIA ELECTRICAL CODE (CURRENT EDITION).
<br />ALL "SWITCHED" OUTLETS SHALL BE 1/2 HOT.
<br />PROVIDE SEPARATE CIRCUITS EACH FOR DISHWASHER, GARBAGE DISPOSAL, REFRIGERATOR,
<br />WASHER, DRYER, FORCED AIR UNIT, AND MICROWAVE OVEN.
<br />ALL EQUIPMENT INSTALLED OUTDOORS AND EXPOSED TO THE WEATHER, SHALL BE WEATHER-
<br />WATER-RESISTIVE MEMBRANE AT EXTERIOR WALLS.
<br />ELASTOMERIC MEMBRANE MATERIALS SHALL BE PROVIDED AT ALL PENETRATIONS OF THE
<br />UATION BY THE SERVICING UTILITY COMPANY.
<br />TRACTOR FROM EACH BUILDING MAIN DISCONNECT TO THE EXTERIOR BUILDING LINE FOR CON-
<br />RULES, REGULATIONS, OR AMENDMENTS.
<br />ALL MATERIAL AND EQUIPMENT SHALL BE NEW AND OF THE SAME MANUFACTURER FOR EACH
<br />CLASS OR GROUP OF EQUIPMENT. MATERIALS SHALL BE LISTED AND APPROVED BY UNDER-
<br />WRITER'S LABORATORIES, INC. (U.L.) AND SHALL BEAR THE INSPECTION LABEL WHERE SUBJECT
<br />TO SUCH APPROVAL.
<br />AS DESIGNATED BY THE SERVICE UTILITY, AND SHALL BE PROVIDED BY THE ELECTRICAL CON-
<br />TIONS TO THE "LINE SIDE" OF ALL BUILDING MAIN DISCONNECTS. RACEWAYS SHALL BE SIZED
<br />ARY SERVICE RACEWAYS AND CONDUCTORS, INCLUDING TRANSFORMERS, PADS, AND CONNEC-
<br />THE SERVICING UTILITY COMPANY SHALL PROVIDE AND INSTALL ALL PRIMARY AND SECOND-
<br />JUNCTION BOXES, TEMPORARY POWER, SUB-PANELS, CONDUIT, ETC.. ALL WORK, MATERIALS,
<br />HAVING JURISDICTION, INCLUDING ALL COUNTY AND STATE ORDINANCES. ALL MATERIAL,
<br />ETC., SHALL COMPLY WITH ALL REQUIREMENTS OF ALL LEGALLY CONSTITUTED AUTHORITIES
<br />INSTALLATION REQUIREMENTS AND LIMITATIONS, SHALL BE VERIFIED AT ALL FIRE AND SOUND
<br />ASSEMBLIES. NOTHING IN THE CONSTRUCTION DOCUMENTS, INCLUDING THESE GENERAL NOTES,
<br />ELECTRICAL
<br />STANDARDS16.1
<br />DIVISION 16 -
<br />FIXTURES, APPLIANCES, WIRING, SWITCHES, OUTLETS, TELEVISION JACKS, SERVICES, GROUNDS,
<br />ACCORDING TO THE BEST PRACTICES OF THE TRADE AND INCLUDING, BUT NOT LIMITED TO:
<br />INSTALLATION OF COMPLETE ELECTRICAL SYSTEM SHALL ALLOW PROPER OPERATION
<br />FOLLOWED FOR ALL MATERIALS PLACED WITHIN OR IN PROXIMITY OF SOIL AS NECESSARY.
<br />ALL ELECTRICAL SERVICES SHALL BE PLACED UNDERGROUND. IN REGARDS TO THE CORRO-
<br />SIVE PROPERTIES OF SOIL, ALL RECOMMENDATIONS IN THE FINAL SOILS REPORT SHALL BE
<br />LIGHT FIXTURES SHALL BE SET AT +84" A.F.F. WHERE DOORS ARE 8'-0" HIGH, AND +78" A.F.F. WHERE DOORS
<br />ARE 6'-8" HIGH.
<br />TYPICAL WALL OUTLETS IN GARAGES SHALL BE SET AT + 42" A.F.F. (U.N.O.).
<br />PROVIDE APPROVED AUTOMATIC FIRE DAMPERS OR MINIMUM 26 GAUGE CORROSION RESIS- TANT METAL
<br />MATERIAL WITH SEATED EDGES AT ALL DUCTWORK PENETRATING FIRE RATED WALLS, FLOORS OR CEILINGS
<br />AS REQUIRED AND ALLOWED BY THE CALIFORNIA MECHANICAL CODE (CURRENT EDITION). ALL FAN SYSTEMS
<br />EXHAUSTING AIR FROM THE BUILDING ENVELOPE TO THE OUTSIDE, SHALL BE PROVIDED WITH BACK DRAFT
<br />DAMPERS.
<br />(CURRENT EDITION).
<br />ALL SECURITY OPENINGS (EXTERIOR DOORS, DOORS BETWEEN HOUSE AND GARAGE, WINDOWS, GARAGE
<br />DOORS, AND THEIR HARDWARE SHALL CONFORM TO THE SECURITY PROVISIONS OF THE CALIFORNIA
<br />BUILDING CODE (CURRENT EDITION), AND ALL APPLICABLE STATE AND AND LOCAL SECURITY ORDINANCES.
<br />ALL FIXTURES, OUTLETS, RECEPTACLES, ETC., PENETRATING FIRE ASSEMBLIES SHALL BE RATED AND INSTALLED
<br />TO MEET THE REQUIREMENTS OF THE CALIFORNIA BUILDING CODE (CURRENT EDITION). OUTLET BOXES ON
<br />OPPOSITE SIDES OF FIRE ASSEMBLIES WALLS SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF AT LEAST 24".MECHANICALDIVISION 15 -
|