Laserfiche WebLink
UNIT CORRIDOR <br />UNIT <br />ONE <br />HOUR <br />UNIT <br />HOUR <br />ONE <br />9' <br />- <br />1 <br />" <br />9' <br />- <br />1 <br />" <br />9' <br />- <br />1 <br />" <br />CORRIDOR <br />CORRIDOR <br />SCALE:1 1/2" = 1'-0" <br />TYP. WALL AND CORRIDOR <br />02.9.17 <br />BUILT-UP ROOF RIPPED TOP <br />SLOPE 1/4" PER FT. SEE ROOF <br />PLAN <br />HOUR <br />ONE <br />8 <br />D0.2 <br />2 <br />D0.2 <br />4 <br />D0.2 <br />4 <br />D0.2 <br />8 <br />D0.2 <br />8 <br />D0.2 <br />OPEN CELL SPRAYFOAM UNDER <br />PLYWOOD SHEATHING. <br />INSTALLED PER MANUF.CLOSE CELL SPRAYFOAM OVER <br />PLYWOOD SHEATHING. <br />INSTALLED PER MANUF. <br />ACOUSTICAL CAULKING <br />AT TOP AND BOTTOM <br />OF BASE LAYER OF <br />GYP. BD., TYPICAL <br />ACOUSTICAL CAULKING <br />AT TOP AND BOTTOM <br />OF BASE LAYER OF <br />GYP. BD., TYPICAL <br />SCALE:1 1/2" = 1'-0" <br />1-HR. PARTY WALL PARALLEL COND. <br />02.9.01 <br />9' <br />- <br />1 <br />" <br /> <br />T <br />Y <br />P <br />. <br />ROOF SHEATHING - <br />OPEN CELL SPRAYFOAM UNDER <br />PLYWOOD SHEATHING. <br />INSTALLED PER MANUF. <br />SHEAR PANEL - SEE <br />STRUCTURAL DRAWINGS <br />STRUCTURAL SHEATHING <br />SHALL BE CONTINUOUS <br />ACROSS AIR GAP <br />ONE <br />HOUR <br />ONE <br />HOUR <br />ONE <br />HOUR <br />ONE <br />HOUR <br />ONE <br />HOUR <br />STRUCTURAL SHEATHING <br />SHALL BE CONTINUOUS <br />ACROSS AIR GAP <br />ONE <br />HOUR <br />STRUCTURAL SHEATHING <br />SHALL BE CONTINUOUS <br />ACROSS AIR GAP <br />FIRESTOPPING - MINERAL <br />FIBER OR GLASS FIBER AT 10 <br />FOOT INTERVALS BOTH <br />HORIZONTAL AND VERTICAL <br />PER UBC SEC. 708.2.1.1 <br />ONE <br />HOUR <br />ONE <br />HOUR <br />ROOF FRAMIND SYSTEM. PER <br />STRUCTURAL PLAN <br />BUILT-UP ROOF RIPPED TOP <br />SLOPE 1/4" PER FT. SEE ROOF <br />PLAN <br />9' <br />- <br />1 <br />" <br /> <br />T <br />Y <br />P <br />. <br />9' <br />- <br />1 <br />" <br /> <br />T <br />Y <br />P <br />. <br />2 <br />D0.2 <br />5 <br />D0.2 <br />6 <br />D0.2 <br />4 <br />D0.2 <br />5 <br />D0.2 <br />6 <br />D0.2 <br />3 <br />D0.2 <br />4 <br />D0.2 <br />5 <br />D0.2 <br />6 <br />D0.2 <br />3 <br />D0.2 <br />CLOSE CELL SPRAYFOAM OVER <br />PLYWOOD SHEATHING. <br />INSTALLED PER MANUF. <br />SCALE:1 1/2" = 1'-0" <br />1-HR. PARTY WALL PERPENDICULAR <br />02.9.02 <br />ROOF SHEATHING - <br />ROOF FRAMIND SYSTEM. PER <br />STRUCTURAL PLAN <br />SHEAR PANEL - SEE <br />STRUCTURAL DRAWINGS <br />STRUCTURAL SHEATHING <br />SHALL BE CONTINUOUS <br />ACROSS AIR GAP <br />ONE <br />HOUR <br />ONE <br />HOUR <br />STRUCTURAL SHEATHING <br />SHALL BE CONTINUOUS <br />ACROSS AIR GAP <br />ONE <br />HOUR <br />ONE <br />HOUR <br />ONE <br />HOUR <br />ONE <br />HOUR <br />STRUCTURAL SHEATHING <br />SHALL BE CONTINUOUS <br />ACROSS AIR GAP <br />FIRESTOPPING - MINERAL <br />FIBER OR GLASS FIBER AT 10 <br />FOOT INTERVALS BOTH <br />HORIZONTAL AND VERTICAL <br />PER UBC SEC. 708.2.1.1 <br />BUILT-UP ROOF RIPPED TOP <br />SLOPE 1/4" PER FT. SEE ROOF <br />PLAN <br />2 <br />D0.2 <br />5 <br />D0.2 <br />4 <br />D0.2 <br />5 <br />D0.2 <br />3 <br />D0.2 <br />5 <br />D0.2 <br />4 <br />D0.2 <br />6 <br />D0.2 <br />6 <br />D0.2 <br />6 <br />D0.2 <br />3 <br />D0.2 <br />OPEN CELL SPRAYFOAM UNDER <br />PLYWOOD SHEATHING. <br />INSTALLED PER MANUF. <br />CLOSE CELL SPRAYFOAM OVER <br />PLYWOOD SHEATHING. <br />INSTALLED PER MANUF. <br />12 9 <br />1 <br />2 <br />36 D0.1 <br />ARCHITECTURAL <br />RATED WALL <br />DETAILS <br />VARIES <br />THE INTENT OF ARCHITECTURAL DETAILING IS TO REPRESENT THE ARCHITECTURAL ELEMENTS - I.E. <br />WATERPROOFING, FENESTRATION, AND FINISHES, ETC. NON-STRUCTURAL FRAMING ELEMENTS <br />SHOWN IN OUR DETAILS SERVE AS A BASIS FOR CREATING A SHAPE OR FORM AND/OR BACKING. IT <br />IS THE DISCRETION OF THE FRAMER TO CONSTRUCT THE SUB-FRAMING AS THEY FEEL FIT FOR <br />EFFICIENCY. ANY STRUCTURAL ELEMENTS ARE TO BE PER THE STRUCTURAL DRAWINGS AND <br />DETAILS - I.E. FRAMING, ANCHORAGE, AND CONNECTIONS AND SUPPORT, ETC. IF THE <br />ARCHITECTURAL AND STRUCTURAL DETAILS DIFFER, THE STRUCTURAL DRAWINGS AND DETAILS <br />TAKES PRECEDENCE. STRUCTURAL SHEAR PANELS ARE NOT SHOWN AND MAY OCCUR AT ANY <br />CONDITION. <br />IT IS THE RESPONSIBILITY OF THE CLIENT / CONTRACTOR TO NOTIFY THE ARCHITECT IN WRITING, <br />PRIOR TO THE COMMENCEMENT OF CONSTRUCTION OR FABRICATION OF MATERIALS OR PRODUCTS <br />OF ANY DISCOVERY OF ERROR, OMISSION OR CONFLICT WHICH MAY OCCUR IN THE CONSTRUCTION <br />DOCUMENTS. <br />1. <br />THE ARCHITECTURAL DETAILING GRAPHICS ARE SLIGHTLY EXAGGERATED TO HELP DELINEATE <br />TYPICAL FLASHING, BUILDING PAPER, BITUMINOUS PAPER AND WINDOW / DOOR FLASHING, ETC.. <br />2. <br />WALL / ATTIC INSULATION SHOWN ON DETAILS OCCURS ONLY WHERE REQUIRED BY CODE. <br />INSULATION MAY NOT BE SHOWN AT ALL CONDITIONS. PROVIDE INSULATION AS NEEDED PER CODE. <br />4. <br />ALL WOOD TRIM, - WHERE OCCURS - INCLUDING BUT NOT LIMITED TO, FASCIA'S CORBELS, TRELLIS <br />MEMBERS, OPEN DECKS, AND OTHER FINISH WORK, ETC., SHALL BE PRE-PRIMED ON ALL SURFACES, <br />INCLUDING NON-EXPOSED SURFACES, PRIOR TO INSTALLATION. FULLY SEAL AND PRIME ALL CUT <br />ENDS OF WOOD MEMBERS IN CONTACT WITH OTHER WOOD MEMBERS. <br />5. <br />CURRENT DATE: 01/18/18 <br />THE ARCHITECTURAL DETAILS MAY DIFFER SLIGHTLY FROM THE PLANS / EXTERIOR ELEVATIONS, <br />ETC. GRAPHICALLY SINCE THOSE AREAS ARE AT A REDUCED SCALE AND MAY NOT ACCURATELY <br />DEPICT DETAIL CONDITIONS. THE ENLARGED DETAIL TAKES PRECEDENCE. <br />3. <br />SCALE:N.T.S. <br />TYPICAL ARCHITECTURAL DETAIL NOTES <br />00.1.01 <br />32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG