Laserfiche WebLink
THE INTENT OF ARCHITECTURAL DETAILING IS TO REPRESENT THE ARCHITECTURAL ELEMENTS - I.E. <br />WATERPROOFING, FENESTRATION, AND FINISHES, ETC. NON-STRUCTURAL FRAMING ELEMENTS <br />SHOWN IN OUR DETAILS SERVE AS A BASIS FOR CREATING A SHAPE OR FORM AND/OR BACKING. IT <br />IS THE DISCRETION OF THE FRAMER TO CONSTRUCT THE SUB-FRAMING AS THEY FEEL FIT FOR <br />EFFICIENCY. ANY STRUCTURAL ELEMENTS ARE TO BE PER THE STRUCTURAL DRAWINGS AND <br />DETAILS - I.E. FRAMING, ANCHORAGE, AND CONNECTIONS AND SUPPORT, ETC. IF THE <br />ARCHITECTURAL AND STRUCTURAL DETAILS DIFFER, THE STRUCTURAL DRAWINGS AND DETAILS <br />TAKES PRECEDENCE. STRUCTURAL SHEAR PANELS ARE NOT SHOWN AND MAY OCCUR AT ANY <br />CONDITION. <br />IT IS THE RESPONSIBILITY OF THE CLIENT / CONTRACTOR TO NOTIFY THE ARCHITECT IN WRITING, <br />PRIOR TO THE COMMENCEMENT OF CONSTRUCTION OR FABRICATION OF MATERIALS OR PRODUCTS <br />OF ANY DISCOVERY OF ERROR, OMISSION OR CONFLICT WHICH MAY OCCUR IN THE CONSTRUCTION <br />DOCUMENTS. <br />1. <br />THE ARCHITECTURAL DETAILING GRAPHICS ARE SLIGHTLY EXAGGERATED TO HELP DELINEATE <br />TYPICAL FLASHING, BUILDING PAPER, BITUMINOUS PAPER AND WINDOW / DOOR FLASHING, ETC.. <br />2. <br />WALL / ATTIC INSULATION SHOWN ON DETAILS OCCURS ONLY WHERE REQUIRED BY CODE. <br />INSULATION MAY NOT BE SHOWN AT ALL CONDITIONS. PROVIDE INSULATION AS NEEDED PER CODE. <br />4. <br />ALL WOOD TRIM, - WHERE OCCURS - INCLUDING BUT NOT LIMITED TO, FASCIA'S CORBELS, TRELLIS <br />MEMBERS, OPEN DECKS, AND OTHER FINISH WORK, ETC., SHALL BE PRE-PRIMED ON ALL SURFACES, <br />INCLUDING NON-EXPOSED SURFACES, PRIOR TO INSTALLATION. FULLY SEAL AND PRIME ALL CUT <br />ENDS OF WOOD MEMBERS IN CONTACT WITH OTHER WOOD MEMBERS. <br />5. <br />CURRENT DATE: 01/18/18 <br />THE ARCHITECTURAL DETAILS MAY DIFFER SLIGHTLY FROM THE PLANS / EXTERIOR ELEVATIONS, <br />ETC. GRAPHICALLY SINCE THOSE AREAS ARE AT A REDUCED SCALE AND MAY NOT ACCURATELY <br />DEPICT DETAIL CONDITIONS. THE ENLARGED DETAIL TAKES PRECEDENCE. <br />3. <br />SCALE:N.T.S. <br />TYPICAL ARCHITECTURAL DETAIL NOTES <br />00.1.01 <br />SCALE:3" = 1'-0" <br />1-HOUR INTERIOR PARTY WALL <br />02.9.10 <br />1" <br />1 LAYER 5/8" TYPE 'X' GYP. BD. EACH SIDE <br />SHEAR PANEL - SEE STRUCTURAL <br />DRAWINGS <br />3 1/2" THICK SOUND ATTENUATION <br />BLANKETS IN BOTH STUD CAVITIES <br />DOUBLE ROW OF 2x4 OR 2X6 WOOD STUDS <br />AT 16" O.C. <br />WALL ASSEMBLY: ONE HOUR FIRE RATING <br />AND STC RATING OF 50-54 GIVEN BY <br />GYPSUM ASSOC. INSTALL PER GA FILE NO. <br />WP 3370 <br />SCALE:3" = 1'-0" <br />1-HOUR CORRIDOR WALL W/ STC 50 TO 54 <br />02.9.24 <br />ONE LAYER 5/8" TYPE "X" GYPSUM BOARD <br />OVER 2x STUD FRAMING AT 16" O.C. <br />INSULATION PER ENERGY CALCULATIONS. <br />WALL ASSEMBLY: ONE HOUR FIRE RATING <br />AND STC RATING OF 50 TO 54 GIVEN BY <br />GYPSUM ASSOC. INSTALL PER GA FILE NO. <br />WP 3242 <br />RESILIENT CHANNELS <br />CORRIDORUNIT <br />SCALE:3" = 1'-0" <br />1-HOUR EXTERIOR WALL ASSEMBLY <br />02.9.25 <br />2 X 6 FRAMING AT 16" O.C. <br />INSULATION NOT REQUIRED WHERE <br />ENCLOSING UN- CONDITONED SPACE <br />7/8" EXTERIOR PLASTER APPLIED IN <br />3-COATS, SCRATCH, BROWN AND FINISH. <br />FINISH SHALL HAVE INTEGRAL COLOR. <br />PLYWOOD WHERE OCCURS <br />5/8" TYPE "X" GYPSUM WALLBOARD <br />ONE HOUR FIRE RATED WALL ASSEMBLY <br />PER CBC TABLE 7-B 15-1.14EXTERIOR SIDEUNIT <br />SIDE <br />SCALE:3" = 1'-0" <br />1-HOUR EXT. WALL ASSEMBLY <br />02.9.27 <br />SHEAR PANEL AS OCCUR <br />2X6 FRAMING AT 16" O.C. <br />INSULATION NOT REQUIRED WHERE <br />ENCLOSING UN- CONDITONED SPACE <br />TYPICAL GYP-BOARD <br />1 LAYERS - 5/8" TYPE "X" GYPSUM <br />WALLBOARD <br />WALL ASSEMBLY: ONE HOUR FIRE RATING <br />GIVEN BY C.B.C. TABLE 7-B ASSEMBLY <br />#15-1.14 <br />FOR ADDITIONAL INFORMATION SEE <br />MECHANICAL DRAWINGS <br />EXTERIOR FINISH MATERIAL. SEE ELEV. <br />EXTERIOR SIDE UNIT SIDE <br />SCALE:1 1/2" = 1'-0" <br />TYP. 1-HOUR PARTY WALL - PARALLEL <br />02.9.07 <br />1/4" MIN. GAP BETWEEN BASE AND <br />FLOOR <br />FILL 1/4" GAP WITH ACOUSTICAL <br />SEALANT BOTH SIDES OF WALL <br />CUT RC CHANNEL SHORT TO PROVIDE <br />1" MIN. GAP <br />FILL 1/4" GAP WITH ACOUSTICAL <br />SEALANT BOTH SIDES OF WALL <br />1- LAYERS 5/8" TYPE "X" <br />PERPENDICULARPARALLEL <br />UNITUNIT <br />UNITUNIT <br />RESILIENT CHANNELS FORM No. 25 <br />MSG GALV. STEEL AND SHAPED AS <br />SHOWN, SPACED 24 IN. O.C. <br />PERPENDICULAR TO JOIST. <br />1/2" EXACOR UNDERLAYMENT ON TOP <br />OF PLYWOOD STRUCTURAL PANEL. <br />INSTALL PER MANUF. SPEC'S <br />1/2" EXACOR UNDERLAYMENT ON TOP <br />OF PLYWOOD STRUCTURAL PANEL. <br />INSTALL PER MANUF. SPEC'S <br />4 <br />D0.2 <br />6.8mm LUXURY VINYL WITH ATTACHED <br />PAD <br />6.8mm LUXURY VINYL WITH ATTACHED <br />PAD <br />SCALE:1 1/2" = 1'-0" <br />1 HOUR 2X ROOF WITH RIPPINGS <br />RF Detail 01 <br />1 - LAYER 5/8" TYPE "X" GYP BD. <br />MIN. 23/32" WOOD STRUCTURAL PANEL <br />ROOF SHEATHING. SEE STRUCTURAL <br />PLANS <br />MIN. 2X10 ROOF JOISTS AT 16" O.C. <br />SEE STRUCTURAL PLANS <br />2X RIPPINGS. SPLOPED PER ROOF <br />PLAN. MIN. HEIGHT 1-1/2" <br />1 HOUR RATED PER C.B.C. 2022 TABLE 721.1 (3). ITEM 13.1.4 <br />OPEN CELL SPRAYFOAM UNDER PLYWOOD <br />SHEATHING. INSTALLED PER MANUF. <br />CLOSE CELL SPRAYFOAM OVER <br />PLYWOOD SHEATHING. <br />INSTALLED PER MANUF. <br />SCALE:1 1/2" = 1'-0" <br />1 HR STC 58 2X FLR ASSEMBLY W/ INSULATION <br />RF Detail 02 A <br />RESILIENT CHANNELS FORM No. 25 MSG <br />GALV. STEEL AND SHAPED AS SHOWN, <br />SPACED 24 IN. O.C. PERPENDICULAR TO <br />JOIST. CHANNELS OVERLAPPED 4" ST <br />SPLINCES AND SECURED TO EACH JOIST <br />WITH ONE 6d COMMOM NAIL. MIN. END <br />SCLEARANCE OF CHANNELS TO WALL TO BE <br />1/2". ADDITIONAL RESILIENT CHANNELS <br />POSITIONED SO AS TO COINCIDE WITH END <br />JOINTS OF GYPSUM BOARD. ADDITIONAL <br />CHANNELS SHALL EXTEND MIN. 6" BEYOND <br />EACH SIDE EDGE OF BOARD. <br />1/2" EXACOR UNDERLAYMENT ON TOP OF <br />PLYWOOD STRUCTURAL PANEL. INSTALL <br />PER MANUF. SPEC'S <br />MIN. R-21 BATT INSULATION PER THERMAL <br />REQUIREMENTS <br />MIN. 2X10 ROOF JOISTS AT 16" O.C. <br />SEE STRUCTURAL PLANS <br />1 HOUR RATED PER UL DESIGN No. L502 (SUBFLOORING SYSTEM No. 24) STC 58 <br />AND IIIC 73 PER CALIFORNIA OFFICE OF NOISE CONTROL ASSEMBLY No. <br />2.1.4.2.1.1 <br />MIN. 23/32" THICK WOOD STRUCTURAL <br />PANEL, SHEATHING. FACE GRAIN OF <br />PLYWOOD. <br />MIN. 2X10 ROOF JOISTS AT 16" O.C. WITH <br />FIREBLOCKING. PER LOCAL CODES. SEE <br />STRUCTURAL PLANS <br />1-LAYER 5/8" THICK 4 FT. WIDE GYPSUM <br />BOARD. WHEN RESILIENT CHANNELS ARE <br />USED. GYPSUM BOARD INSTALLED WITH <br />LONG DIMENSION PERPENDICULAR TO <br />RESILIENT CHANNELS AND SIDE JOINTS OF <br />SHEET LOCATED BETWEEN JOISTS. NOM 1" <br />LONG TYPE S BUGLE HEAD SCREWS ARE <br />DRIVEN THROUGH CHANNEL SPACED 8" O.C. <br />END JOINTS OF GYPSUM BOARD SIMILARLY <br />FASTENED TO ADDITIONAL RESILIENT <br />CHANNELS POSITIONED AT END JOINT <br />LOCATIONS. <br />6.8mm LUXURY VINYL WITH ATTACHED <br />PAD <br />SCALE:1 1/2" = 1'-0" <br />1-HOUR PARTY WALL - PLAN <br />D5 1HRW <br />2' <br />- <br />0 <br />" <br /> <br />( <br />3 <br />' <br />- <br />0 <br />" <br /> <br />P <br />R <br />E <br />F <br />E <br />R <br />R <br />E <br />D <br />) <br />OR <br /> <br />2 <br /> <br />S <br />T <br />U <br />D <br /> <br />B <br />A <br />Y <br />S <br />, <br /> <br />M <br />I <br />N <br />. <br />FIREBLOCKING: MINERAL FIBER OR GLASS <br />FIBER BLANKETS OR OTHER APPROVED <br />FLEXIBLE MATERIAL SECURELY RETAINED <br />IN PLACE AT MAX. 10 FOOT INTERVALS BOTH <br />VERT. AND HORIZ. AND AT FLOOR AND <br />CEILING PER C.B.C. 718.2 <br />(1) LAYER 5/8" TYPE-'X' GYP. BD. <br />ELECTRICAL, TELEPHONE OR CABLE TV <br />OUTLET BOXES NOT TO EXCEED 16 SQ. IN. <br />PER C.B.C. SEC. 712 OR NON-METALLIC <br />OUTLET BOXES WITH AN EQUAL OR <br />GREATER RATING THAN THE WALL <br />ASSEMBLY. REFER TO ACOUSTICAL <br />REPORT. PROVIDE 1/4" - 1/2" JOINT FILLED <br />WITH BEAD OF 3M - CP 25N/S CAULK FACE <br />FLANGE - DRYWALL OR PLASTER OVERLAPS <br />FLANGE. <br />TYP. BATT INSULATION. <br />1" <br />1 - LAYER "HILTI" CP 617 FIRESTOP PUTTY <br />PADS WRAP AROUND METALLIC OUT <br />BOXES <br />TYP. METAL OR WOOD STUD WALLS <br />UNIT UNIT <br />11 <br />12 <br />10 <br />9 <br />8 <br />7 1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG <br />D0.2 <br />ARCHITECTURAL <br />RATED WALL <br />DETAILS <br />VARIES <br />SCALE:1 1/2" = 1'-0" <br />RECESS CAN <br />REC CAN_01 <br />MIN. 2X10 ROOF JOISTS AT 16" O.C. <br />SEE STRUCTURAL PLANS <br />1-LAYER 5/8" THICK 4 FT. WIDE GYPSUM <br />BOARD. WHEN RESILIENT CHANNELS ARE <br />USED. GYPSUM BOARD INSTALLED WITH <br />LONG DIMENSION PERPENDICULAR TO <br />RESILIENT CHANNELS AND SIDE JOINTS OF <br />SHEET LOCATED BETWEEN JOISTS. NOM 1" <br />LONG TYPE S BUGLE HEAD SCREWS ARE <br />DRIVEN THROUGH CHANNEL SPACED 8" O.C. <br />END JOINTS OF GYPSUM BOARD SIMILARLY <br />FASTENED TO ADDITIONAL RESILIENT <br />CHANNELS POSITIONED AT END JOINT <br />LOCATIONS. <br />2-HR FIRE RATED DOWNLIGHT RAZOR, <br />BY NDR LIGHTING. INSTALLED PER <br />MANUF. SPECS. NO SUBSTITUTE <br />ALLOWED AND MUST BE CERTIFIED <br />FOR 1-HR RATED SYSTEM. <br />THE RAZOR FIRE RATED: UL L505, L511, <br />L538, L541, L556, L577, M500, M510, <br />M521 AND M543. <br />1/2" EXACOR UNDERLAYMENT ON TOP OF <br />PLYWOOD STRUCTURAL PANEL. INSTALL <br />PER MANUF. SPEC'S <br />MIN. 23/32" THICK WOOD STRUCTURAL <br />PANEL, SHEATHING. FACE GRAIN OF <br />PLYWOOD. <br />1 HOUR RATED PER UL DESIGN No. L502 (SUBFLOORING SYSTEM No. 24) STC 58 <br />AND IIIC 73 PER CALIFORNIA OFFICE OF NOISE CONTROL ASSEMBLY No. <br />2.1.4.2.1.1 <br />RESILIENT CHANNELS FORM No. 25 MSG <br />GALV. STEEL AND SHAPED AS SHOWN, <br />SPACED 24 IN. O.C. PERPENDICULAR TO <br />JOIST. CHANNELS OVERLAPPED 4" ST <br />SPLINCES AND SECURED TO EACH JOIST <br />WITH ONE 6d COMMOM NAIL. MIN. END <br />SCLEARANCE OF CHANNELS TO WALL TO BE <br />1/2". ADDITIONAL RESILIENT CHANNELS <br />POSITIONED SO AS TO COINCIDE WITH END <br />JOINTS OF GYPSUM BOARD. ADDITIONAL <br />CHANNELS SHALL EXTEND MIN. 6" BEYOND <br />EACH SIDE EDGE OF BOARD. <br />6.8mm LUXURY VINYL WITH ATTACHED <br />PAD <br />SCALE:1 1/2" = 1'-0" <br />MECHANICAL SOFFIT <br />02.13.01_A <br />FLOOR FRAMING SYSTEM. <br />SEE STRUCTURAL PLANS <br />FINISH FLOOR MATERIAL, SEE DETAIL 4/D0.2 <br />FLOOR PLYWOOD SHEATHING <br />BATT INSULATION PER <br />TITLE 24 REPORT <br />2X SOFFIT FRAMING <br />UNIMAST RC DELUXE RESILIENT <br />CHANNEL PERP. TO FLOOR JOIST 24" <br />O.C. <br />CUT RC CHANNEL SHORT TO PROVIDE <br />1" MIN. GAP <br />1- LAYERS 5/8" TYPE "X" <br />2X FRAMING <br />PARALLELPERPENDICULAR <br />UNIT <br />UNIT <br />UNIT <br />UNIT <br />SCALE:1 1/2" = 1'-0" <br />FIRE EXTINGUSHER DETAIL <br />23.01.01 <br />2 HOUR RATED FIRE BARRIER <br />FIRE EXTINGUISHER <br />1 HOUR RATED CORRIDOR WALL <br />FIRE EXTINGUISHER <br />FIRE EXTINGUISHER 2 HR. WALL <br />FIRE EXTINGUISHER 1-HR. WALL <br />SEMI-RECESSED FIRE RATED FIRE <br />EXTINGUSHER CABINET <br />2 LAYERS 5/8" THK TYPE 'X' GYP. <br />TO MAINTAIN 2-HR. FIRE RATING <br />5/8" THK TYPE 'X' GYP. BD. TO MAINTAIN <br />1-HR. FIRE RATING <br />SEMI-RECESSED FIRE RATED FIRE <br />EXTINGUISHER CABINET <br />PANEL ACCESS <br />PANEL ACCESS <br />FIRE EXTINGUISHER