THE INTENT OF ARCHITECTURAL DETAILING IS TO REPRESENT THE ARCHITECTURAL ELEMENTS - I.E.
<br />WATERPROOFING, FENESTRATION, AND FINISHES, ETC. NON-STRUCTURAL FRAMING ELEMENTS
<br />SHOWN IN OUR DETAILS SERVE AS A BASIS FOR CREATING A SHAPE OR FORM AND/OR BACKING. IT
<br />IS THE DISCRETION OF THE FRAMER TO CONSTRUCT THE SUB-FRAMING AS THEY FEEL FIT FOR
<br />EFFICIENCY. ANY STRUCTURAL ELEMENTS ARE TO BE PER THE STRUCTURAL DRAWINGS AND
<br />DETAILS - I.E. FRAMING, ANCHORAGE, AND CONNECTIONS AND SUPPORT, ETC. IF THE
<br />ARCHITECTURAL AND STRUCTURAL DETAILS DIFFER, THE STRUCTURAL DRAWINGS AND DETAILS
<br />TAKES PRECEDENCE. STRUCTURAL SHEAR PANELS ARE NOT SHOWN AND MAY OCCUR AT ANY
<br />CONDITION.
<br />IT IS THE RESPONSIBILITY OF THE CLIENT / CONTRACTOR TO NOTIFY THE ARCHITECT IN WRITING,
<br />PRIOR TO THE COMMENCEMENT OF CONSTRUCTION OR FABRICATION OF MATERIALS OR PRODUCTS
<br />OF ANY DISCOVERY OF ERROR, OMISSION OR CONFLICT WHICH MAY OCCUR IN THE CONSTRUCTION
<br />DOCUMENTS.
<br />1.
<br />THE ARCHITECTURAL DETAILING GRAPHICS ARE SLIGHTLY EXAGGERATED TO HELP DELINEATE
<br />TYPICAL FLASHING, BUILDING PAPER, BITUMINOUS PAPER AND WINDOW / DOOR FLASHING, ETC..
<br />2.
<br />WALL / ATTIC INSULATION SHOWN ON DETAILS OCCURS ONLY WHERE REQUIRED BY CODE.
<br />INSULATION MAY NOT BE SHOWN AT ALL CONDITIONS. PROVIDE INSULATION AS NEEDED PER CODE.
<br />4.
<br />ALL WOOD TRIM, - WHERE OCCURS - INCLUDING BUT NOT LIMITED TO, FASCIA'S CORBELS, TRELLIS
<br />MEMBERS, OPEN DECKS, AND OTHER FINISH WORK, ETC., SHALL BE PRE-PRIMED ON ALL SURFACES,
<br />INCLUDING NON-EXPOSED SURFACES, PRIOR TO INSTALLATION. FULLY SEAL AND PRIME ALL CUT
<br />ENDS OF WOOD MEMBERS IN CONTACT WITH OTHER WOOD MEMBERS.
<br />5.
<br />CURRENT DATE: 01/18/18
<br />THE ARCHITECTURAL DETAILS MAY DIFFER SLIGHTLY FROM THE PLANS / EXTERIOR ELEVATIONS,
<br />ETC. GRAPHICALLY SINCE THOSE AREAS ARE AT A REDUCED SCALE AND MAY NOT ACCURATELY
<br />DEPICT DETAIL CONDITIONS. THE ENLARGED DETAIL TAKES PRECEDENCE.
<br />3.
<br />SCALE:N.T.S.
<br />TYPICAL ARCHITECTURAL DETAIL NOTES
<br />00.1.01
<br />SCALE:3" = 1'-0"
<br />1-HOUR INTERIOR PARTY WALL
<br />02.9.10
<br />1"
<br />1 LAYER 5/8" TYPE 'X' GYP. BD. EACH SIDE
<br />SHEAR PANEL - SEE STRUCTURAL
<br />DRAWINGS
<br />3 1/2" THICK SOUND ATTENUATION
<br />BLANKETS IN BOTH STUD CAVITIES
<br />DOUBLE ROW OF 2x4 OR 2X6 WOOD STUDS
<br />AT 16" O.C.
<br />WALL ASSEMBLY: ONE HOUR FIRE RATING
<br />AND STC RATING OF 50-54 GIVEN BY
<br />GYPSUM ASSOC. INSTALL PER GA FILE NO.
<br />WP 3370
<br />SCALE:3" = 1'-0"
<br />1-HOUR CORRIDOR WALL W/ STC 50 TO 54
<br />02.9.24
<br />ONE LAYER 5/8" TYPE "X" GYPSUM BOARD
<br />OVER 2x STUD FRAMING AT 16" O.C.
<br />INSULATION PER ENERGY CALCULATIONS.
<br />WALL ASSEMBLY: ONE HOUR FIRE RATING
<br />AND STC RATING OF 50 TO 54 GIVEN BY
<br />GYPSUM ASSOC. INSTALL PER GA FILE NO.
<br />WP 3242
<br />RESILIENT CHANNELS
<br />CORRIDORUNIT
<br />SCALE:3" = 1'-0"
<br />1-HOUR EXTERIOR WALL ASSEMBLY
<br />02.9.25
<br />2 X 6 FRAMING AT 16" O.C.
<br />INSULATION NOT REQUIRED WHERE
<br />ENCLOSING UN- CONDITONED SPACE
<br />7/8" EXTERIOR PLASTER APPLIED IN
<br />3-COATS, SCRATCH, BROWN AND FINISH.
<br />FINISH SHALL HAVE INTEGRAL COLOR.
<br />PLYWOOD WHERE OCCURS
<br />5/8" TYPE "X" GYPSUM WALLBOARD
<br />ONE HOUR FIRE RATED WALL ASSEMBLY
<br />PER CBC TABLE 7-B 15-1.14EXTERIOR SIDEUNIT
<br />SIDE
<br />SCALE:3" = 1'-0"
<br />1-HOUR EXT. WALL ASSEMBLY
<br />02.9.27
<br />SHEAR PANEL AS OCCUR
<br />2X6 FRAMING AT 16" O.C.
<br />INSULATION NOT REQUIRED WHERE
<br />ENCLOSING UN- CONDITONED SPACE
<br />TYPICAL GYP-BOARD
<br />1 LAYERS - 5/8" TYPE "X" GYPSUM
<br />WALLBOARD
<br />WALL ASSEMBLY: ONE HOUR FIRE RATING
<br />GIVEN BY C.B.C. TABLE 7-B ASSEMBLY
<br />#15-1.14
<br />FOR ADDITIONAL INFORMATION SEE
<br />MECHANICAL DRAWINGS
<br />EXTERIOR FINISH MATERIAL. SEE ELEV.
<br />EXTERIOR SIDE UNIT SIDE
<br />SCALE:1 1/2" = 1'-0"
<br />TYP. 1-HOUR PARTY WALL - PARALLEL
<br />02.9.07
<br />1/4" MIN. GAP BETWEEN BASE AND
<br />FLOOR
<br />FILL 1/4" GAP WITH ACOUSTICAL
<br />SEALANT BOTH SIDES OF WALL
<br />CUT RC CHANNEL SHORT TO PROVIDE
<br />1" MIN. GAP
<br />FILL 1/4" GAP WITH ACOUSTICAL
<br />SEALANT BOTH SIDES OF WALL
<br />1- LAYERS 5/8" TYPE "X"
<br />PERPENDICULARPARALLEL
<br />UNITUNIT
<br />UNITUNIT
<br />RESILIENT CHANNELS FORM No. 25
<br />MSG GALV. STEEL AND SHAPED AS
<br />SHOWN, SPACED 24 IN. O.C.
<br />PERPENDICULAR TO JOIST.
<br />1/2" EXACOR UNDERLAYMENT ON TOP
<br />OF PLYWOOD STRUCTURAL PANEL.
<br />INSTALL PER MANUF. SPEC'S
<br />1/2" EXACOR UNDERLAYMENT ON TOP
<br />OF PLYWOOD STRUCTURAL PANEL.
<br />INSTALL PER MANUF. SPEC'S
<br />4
<br />D0.2
<br />6.8mm LUXURY VINYL WITH ATTACHED
<br />PAD
<br />6.8mm LUXURY VINYL WITH ATTACHED
<br />PAD
<br />SCALE:1 1/2" = 1'-0"
<br />1 HOUR 2X ROOF WITH RIPPINGS
<br />RF Detail 01
<br />1 - LAYER 5/8" TYPE "X" GYP BD.
<br />MIN. 23/32" WOOD STRUCTURAL PANEL
<br />ROOF SHEATHING. SEE STRUCTURAL
<br />PLANS
<br />MIN. 2X10 ROOF JOISTS AT 16" O.C.
<br />SEE STRUCTURAL PLANS
<br />2X RIPPINGS. SPLOPED PER ROOF
<br />PLAN. MIN. HEIGHT 1-1/2"
<br />1 HOUR RATED PER C.B.C. 2022 TABLE 721.1 (3). ITEM 13.1.4
<br />OPEN CELL SPRAYFOAM UNDER PLYWOOD
<br />SHEATHING. INSTALLED PER MANUF.
<br />CLOSE CELL SPRAYFOAM OVER
<br />PLYWOOD SHEATHING.
<br />INSTALLED PER MANUF.
<br />SCALE:1 1/2" = 1'-0"
<br />1 HR STC 58 2X FLR ASSEMBLY W/ INSULATION
<br />RF Detail 02 A
<br />RESILIENT CHANNELS FORM No. 25 MSG
<br />GALV. STEEL AND SHAPED AS SHOWN,
<br />SPACED 24 IN. O.C. PERPENDICULAR TO
<br />JOIST. CHANNELS OVERLAPPED 4" ST
<br />SPLINCES AND SECURED TO EACH JOIST
<br />WITH ONE 6d COMMOM NAIL. MIN. END
<br />SCLEARANCE OF CHANNELS TO WALL TO BE
<br />1/2". ADDITIONAL RESILIENT CHANNELS
<br />POSITIONED SO AS TO COINCIDE WITH END
<br />JOINTS OF GYPSUM BOARD. ADDITIONAL
<br />CHANNELS SHALL EXTEND MIN. 6" BEYOND
<br />EACH SIDE EDGE OF BOARD.
<br />1/2" EXACOR UNDERLAYMENT ON TOP OF
<br />PLYWOOD STRUCTURAL PANEL. INSTALL
<br />PER MANUF. SPEC'S
<br />MIN. R-21 BATT INSULATION PER THERMAL
<br />REQUIREMENTS
<br />MIN. 2X10 ROOF JOISTS AT 16" O.C.
<br />SEE STRUCTURAL PLANS
<br />1 HOUR RATED PER UL DESIGN No. L502 (SUBFLOORING SYSTEM No. 24) STC 58
<br />AND IIIC 73 PER CALIFORNIA OFFICE OF NOISE CONTROL ASSEMBLY No.
<br />2.1.4.2.1.1
<br />MIN. 23/32" THICK WOOD STRUCTURAL
<br />PANEL, SHEATHING. FACE GRAIN OF
<br />PLYWOOD.
<br />MIN. 2X10 ROOF JOISTS AT 16" O.C. WITH
<br />FIREBLOCKING. PER LOCAL CODES. SEE
<br />STRUCTURAL PLANS
<br />1-LAYER 5/8" THICK 4 FT. WIDE GYPSUM
<br />BOARD. WHEN RESILIENT CHANNELS ARE
<br />USED. GYPSUM BOARD INSTALLED WITH
<br />LONG DIMENSION PERPENDICULAR TO
<br />RESILIENT CHANNELS AND SIDE JOINTS OF
<br />SHEET LOCATED BETWEEN JOISTS. NOM 1"
<br />LONG TYPE S BUGLE HEAD SCREWS ARE
<br />DRIVEN THROUGH CHANNEL SPACED 8" O.C.
<br />END JOINTS OF GYPSUM BOARD SIMILARLY
<br />FASTENED TO ADDITIONAL RESILIENT
<br />CHANNELS POSITIONED AT END JOINT
<br />LOCATIONS.
<br />6.8mm LUXURY VINYL WITH ATTACHED
<br />PAD
<br />SCALE:1 1/2" = 1'-0"
<br />1-HOUR PARTY WALL - PLAN
<br />D5 1HRW
<br />2'
<br />-
<br />0
<br />"
<br />
<br />(
<br />3
<br />'
<br />-
<br />0
<br />"
<br />
<br />P
<br />R
<br />E
<br />F
<br />E
<br />R
<br />R
<br />E
<br />D
<br />)
<br />OR
<br />
<br />2
<br />
<br />S
<br />T
<br />U
<br />D
<br />
<br />B
<br />A
<br />Y
<br />S
<br />,
<br />
<br />M
<br />I
<br />N
<br />.
<br />FIREBLOCKING: MINERAL FIBER OR GLASS
<br />FIBER BLANKETS OR OTHER APPROVED
<br />FLEXIBLE MATERIAL SECURELY RETAINED
<br />IN PLACE AT MAX. 10 FOOT INTERVALS BOTH
<br />VERT. AND HORIZ. AND AT FLOOR AND
<br />CEILING PER C.B.C. 718.2
<br />(1) LAYER 5/8" TYPE-'X' GYP. BD.
<br />ELECTRICAL, TELEPHONE OR CABLE TV
<br />OUTLET BOXES NOT TO EXCEED 16 SQ. IN.
<br />PER C.B.C. SEC. 712 OR NON-METALLIC
<br />OUTLET BOXES WITH AN EQUAL OR
<br />GREATER RATING THAN THE WALL
<br />ASSEMBLY. REFER TO ACOUSTICAL
<br />REPORT. PROVIDE 1/4" - 1/2" JOINT FILLED
<br />WITH BEAD OF 3M - CP 25N/S CAULK FACE
<br />FLANGE - DRYWALL OR PLASTER OVERLAPS
<br />FLANGE.
<br />TYP. BATT INSULATION.
<br />1"
<br />1 - LAYER "HILTI" CP 617 FIRESTOP PUTTY
<br />PADS WRAP AROUND METALLIC OUT
<br />BOXES
<br />TYP. METAL OR WOOD STUD WALLS
<br />UNIT UNIT
<br />11
<br />12
<br />10
<br />9
<br />8
<br />7 1
<br />2
<br />3
<br />4
<br />5
<br />6
<br />32
<br />2
<br />
<br />N
<br />.
<br />
<br />H
<br />A
<br />R
<br />B
<br />O
<br />R
<br />
<br />
<br />B
<br />L
<br />V
<br />D
<br />.
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />3
<br />SHEET NUMBER
<br />2 0 2 4 0 1 0
<br />SHEET TITLE
<br />PROJECT NUMBER
<br />REVISIONS
<br />NO.DATE NO.DATE
<br />HANNOUCHE ARCHITECTS
<br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT
<br />AND OTHER PROPERTY RIGHTS INHERENT IN
<br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES,
<br />FIELD NOTES AND ASSOCIATED DOCUMENTS
<br />ARE INSTRUMENTS OF SERVICE AND ARE THE
<br />PROPERTY OF HANNOUCHE ARCHITECTS.
<br />ALL INFORMATION CONTAINED IN THESE DRAWINGS,
<br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED
<br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT
<br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED,
<br />OR USED OTHERWISE IN ANY FORM OR MANNER
<br />WHATSOEVER, WITHOUT FIRST OBTAINING THE
<br />EXPRESSED WRITTEN PERMISSION AND CONSENT
<br />OF HANNOUCHE ARCHITECTS.
<br />HANNOUCHE ARCHITECT c 2021
<br />HANNOUCHE
<br />ARCHITECTS
<br />949.261.2070
<br />SAMIR HANNOUCHE, ARCHITECT
<br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660
<br />May 9, 2025
<br />1 CORR
<br />12/10/24
<br />BLDG
<br />A CORR
<br />3/18/25
<br />OCFA
<br />2 CORR
<br />4/09/25
<br />BLDG
<br />DATE SIGNED2
<br />3 CORR
<br />5/09/25
<br />BLDG
<br />D0.2
<br />ARCHITECTURAL
<br />RATED WALL
<br />DETAILS
<br />VARIES
<br />SCALE:1 1/2" = 1'-0"
<br />RECESS CAN
<br />REC CAN_01
<br />MIN. 2X10 ROOF JOISTS AT 16" O.C.
<br />SEE STRUCTURAL PLANS
<br />1-LAYER 5/8" THICK 4 FT. WIDE GYPSUM
<br />BOARD. WHEN RESILIENT CHANNELS ARE
<br />USED. GYPSUM BOARD INSTALLED WITH
<br />LONG DIMENSION PERPENDICULAR TO
<br />RESILIENT CHANNELS AND SIDE JOINTS OF
<br />SHEET LOCATED BETWEEN JOISTS. NOM 1"
<br />LONG TYPE S BUGLE HEAD SCREWS ARE
<br />DRIVEN THROUGH CHANNEL SPACED 8" O.C.
<br />END JOINTS OF GYPSUM BOARD SIMILARLY
<br />FASTENED TO ADDITIONAL RESILIENT
<br />CHANNELS POSITIONED AT END JOINT
<br />LOCATIONS.
<br />2-HR FIRE RATED DOWNLIGHT RAZOR,
<br />BY NDR LIGHTING. INSTALLED PER
<br />MANUF. SPECS. NO SUBSTITUTE
<br />ALLOWED AND MUST BE CERTIFIED
<br />FOR 1-HR RATED SYSTEM.
<br />THE RAZOR FIRE RATED: UL L505, L511,
<br />L538, L541, L556, L577, M500, M510,
<br />M521 AND M543.
<br />1/2" EXACOR UNDERLAYMENT ON TOP OF
<br />PLYWOOD STRUCTURAL PANEL. INSTALL
<br />PER MANUF. SPEC'S
<br />MIN. 23/32" THICK WOOD STRUCTURAL
<br />PANEL, SHEATHING. FACE GRAIN OF
<br />PLYWOOD.
<br />1 HOUR RATED PER UL DESIGN No. L502 (SUBFLOORING SYSTEM No. 24) STC 58
<br />AND IIIC 73 PER CALIFORNIA OFFICE OF NOISE CONTROL ASSEMBLY No.
<br />2.1.4.2.1.1
<br />RESILIENT CHANNELS FORM No. 25 MSG
<br />GALV. STEEL AND SHAPED AS SHOWN,
<br />SPACED 24 IN. O.C. PERPENDICULAR TO
<br />JOIST. CHANNELS OVERLAPPED 4" ST
<br />SPLINCES AND SECURED TO EACH JOIST
<br />WITH ONE 6d COMMOM NAIL. MIN. END
<br />SCLEARANCE OF CHANNELS TO WALL TO BE
<br />1/2". ADDITIONAL RESILIENT CHANNELS
<br />POSITIONED SO AS TO COINCIDE WITH END
<br />JOINTS OF GYPSUM BOARD. ADDITIONAL
<br />CHANNELS SHALL EXTEND MIN. 6" BEYOND
<br />EACH SIDE EDGE OF BOARD.
<br />6.8mm LUXURY VINYL WITH ATTACHED
<br />PAD
<br />SCALE:1 1/2" = 1'-0"
<br />MECHANICAL SOFFIT
<br />02.13.01_A
<br />FLOOR FRAMING SYSTEM.
<br />SEE STRUCTURAL PLANS
<br />FINISH FLOOR MATERIAL, SEE DETAIL 4/D0.2
<br />FLOOR PLYWOOD SHEATHING
<br />BATT INSULATION PER
<br />TITLE 24 REPORT
<br />2X SOFFIT FRAMING
<br />UNIMAST RC DELUXE RESILIENT
<br />CHANNEL PERP. TO FLOOR JOIST 24"
<br />O.C.
<br />CUT RC CHANNEL SHORT TO PROVIDE
<br />1" MIN. GAP
<br />1- LAYERS 5/8" TYPE "X"
<br />2X FRAMING
<br />PARALLELPERPENDICULAR
<br />UNIT
<br />UNIT
<br />UNIT
<br />UNIT
<br />SCALE:1 1/2" = 1'-0"
<br />FIRE EXTINGUSHER DETAIL
<br />23.01.01
<br />2 HOUR RATED FIRE BARRIER
<br />FIRE EXTINGUISHER
<br />1 HOUR RATED CORRIDOR WALL
<br />FIRE EXTINGUISHER
<br />FIRE EXTINGUISHER 2 HR. WALL
<br />FIRE EXTINGUISHER 1-HR. WALL
<br />SEMI-RECESSED FIRE RATED FIRE
<br />EXTINGUSHER CABINET
<br />2 LAYERS 5/8" THK TYPE 'X' GYP.
<br />TO MAINTAIN 2-HR. FIRE RATING
<br />5/8" THK TYPE 'X' GYP. BD. TO MAINTAIN
<br />1-HR. FIRE RATING
<br />SEMI-RECESSED FIRE RATED FIRE
<br />EXTINGUISHER CABINET
<br />PANEL ACCESS
<br />PANEL ACCESS
<br />FIRE EXTINGUISHER
|