GENERAL NOTES (CONT.)GENERAL NOTES <br />1.PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM <br />ALL LABOR REQUIRED TO INSTALL COMPLETE AND <br />OPERABLE PLUMBING SYSTEMS AS INDICATED ON THE <br />DRAWINGS, AS SPECIFIED, PER MANUFACTURER’S <br />RECOMMENDATIONS, AND IN ACCORDANCE WITH ALL <br />APPLICABLE CODES, ORDINANCES, LAWS, AND PERMITS. <br />SUCH ITEMS INCLUDE BUT ARE NOT LIMITED TO THOSE <br />LISTED IN THE "APPLICABLE CODES" TABLE ON THIS SHEET. <br />2.WHERE THERE IS A CONFLICT BETWEEN THE DRAWINGS <br />AND SPECIFICATIONS, THE MORE STRINGENT REQUIREMENT <br />SHALL APPLY. <br />3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE <br />ACCURATE PLACEMENT OF ALL NEW CONSTRUCTION ON <br />THE SITE. <br />4.THE CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND <br />DIMENSIONS, AND EXACT LOCATIONS AND ELEVATIONS OF <br />PIPING BEFORE STARTING WORK. SHOULD A DISCREPANCY <br />APPEAR IN THE CONTRACT DOCUMENTS, OR BETWEEN THE <br />CONTRACT DOCUMENTS AND EXISTING CONDITIONS, <br />NOTIFY THE ARCHITECT AT ONCE FOR INSTRUCTION ON <br />HOW TO PROCEED. <br />5.THE CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND <br />DIMENSIONS, AND VERIFY EXACT LOCATIONS AND <br />ELEVATIONS OF PIPING POINTS OF CONNECTION BY MEANS <br />OF PHYSICAL EXCAVATION AND SELECTIVE DEMOLITION <br />BEFORE STARTING WORK. SHOULD A DISCREPANCY <br />APPEAR IN THE CONTRACT DOCUMENTS, OR BETWEEN THE <br />CONTRACT DOCUMENTS AND EXISTING CONDITIONS, <br />NOTIFY THE ARCHITECT OR OWNER’S REPRESENTATIVE AT <br />ONCE FOR INSTRUCTION ON HOW TO PROCEED. <br />6.ALL EXCAVATION AND TRENCHING SHALL BE PERFORMED IN <br />STRICT COMPLIANCE WITH THE REGULATIONS OF THE <br />OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION <br />(OSHA). <br />7.ALL PIPING SHALL BE KEPT CLEARED FROM LOAD BEARING <br />FOOTINGS. SEE STRUCTURAL DRAWINGS AND <br />SPECIFICATIONS FOR ADDITIONAL INFORMATION. <br />8.SEWER, WATER, AND STORM DRAIN SYSTEMS INDICATED IN <br />THESE DRAWINGS SHALL EXTEND TO PLUMBING/CIVIL <br />POINTS OF CONNECTION AT 5'-0" OUTSIDE OF THE <br />BUILDING(S) UNLESS OTHERWISE INDICATED. <br />CONTINUATION OF SUCH PIPING SYSTEMS ARE INDICATED <br />ON THE CIVIL DRAWINGS WITH CORRESPONDING <br />ASSOCIATED MATERIALS SPECIFIED UNDER A SEPARATE <br />SECTION OF THE PROJECT SPECIFICATIONS. ALL SUCH <br />PIPING SHALL BE INSTALLED IN A MANNER TO PROVIDE <br />PROPER CONNECTION TO INVERT ELEVATIONS INDICATED <br />ON CIVIL DRAWINGS. WHERE SIZES DIFFER BETWEEN <br />PLUMBING AND CIVIL DRAWINGS, CONTRACTOR SHALL <br />PROVIDE TRANSITION FITTINGS AS NECESSARY TO ALLOW <br />FOR PROPER CONNECTION. <br />9.HORIZONTAL WASTE PIPING WITHIN THE BUILDING SHALL BE <br />INSTALLED CONCEALED WITHIN WALLS, BELOW FINISH <br />FLOOR, OR BELOW FINISH SLAB AS APPLICABLE UNLESS <br />NOTED OTHERWISE. ALL OTHER HORIZONTAL PIPING WITHIN <br />THE BUILDING SHALL BE INSTALLED CONCEALED ABOVE <br />CEILING OR WITHIN WALLS AS APPLICABLE UNLESS NOTED <br />OTHERWISE. ALL VERTICAL PIPING SHALL BE INSTALLED <br />CONCEALED WITHIN WALLS UNLESS NOTED OTHERWISE. NO <br />PIPING SHALL BE INSTALLED IN EXPOSED LOCATIONS <br />UNLESS SPECIFICALLY NOTED AS SUCH ON PLANS. <br />10.REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS, <br />ROUGH IN DIMENSIONS, AND MOUNTING HEIGHTS OF ALL <br />EXPOSED ELEMENTS. SUCH ITEMS INCLUDE, BUT ARE NOT <br />LIMITED TO PLUMBING FIXTURES AND EQUIPMENT, ACCESS <br />PANELS, HOSE BIBBS, RECESSED HOSE BIBBS, AND <br />OVERFLOW DRAIN TERMINATION POINTS. WHERE <br />DIMENSIONS ARE NOT INDICATED, SEEK ARCHITECT'S <br />DIRECTION AND/OR APPROVAL PRIOR TO INSTALLATION. <br />11.WATER HAMMER ARRESTOR SIZES SHALL CORRESPOND TO <br />PLUMBING & DRAINAGE INSTITUTE (PDI) WATER HAMMER <br />ARRESTERS STANDARD PDI-WH 201 CURRENT EDITION <br />SIZING RECOMMENDATIONS. <br />12.HOSE BIBBS SHALL BE EQUIPPED WITH AN APPROVED NON <br />REMOVABLE VACUUM BREAKER. <br />13.PROVIDE ACCESS PANELS IN WALLS AND HARD SUSPENDED <br />CEILINGS WHERE REQUIRED TO SERVICE TRAPS, <br />CLEANOUTS, VALVES, MIXING VALVES, TRAP PRIMERS, <br />WATER HAMMER ARRESTORS AND OTHER CONCEALED <br />PLUMBING APPURTENANCES. WHERE POSSIBLE, USE SAME <br />ACCESS PANEL TO SERVICE MORE THAN ONE ITEM WHEN <br />LOCATED DIRECTLY ADJACENT IN SAME IMMEDIATE <br />VICINITY. REFER TO SPECIFICATIONS FOR ACCESS PANEL <br />REQUIREMENTS. <br />14.REFER TO DETAILS FOR ADDITIONAL COORDINATION, SHOP <br />DRAWING, AND INSTALLATION REQUIREMENTS FOR TYPICAL <br />EXPOSED PLUMBING ELEMENTS IN RESTROOMS. <br />15.ACCESS PANELS. <br />A.WHERE POSSIBLE, USE SAME ACCESS PANEL FOR <br />SHUT-OFF VALVES, MIXING VALVES, TRAP PRIMERS <br />AND WATER HAMMER ARRESTORS AND/OR OTHER <br />INTERIOR WALL COMPONENTS WHEN LOCATED <br />DIRECTLY ADJACENT IN SAME IMMEDIATE VICINITY. <br />SEE ARCHITECTURAL DRAWINGS FOR MOUNTING <br />HEIGHTS. <br />B.SEE SPECIFICATIONS FOR ACCESS PANEL <br />REQUIREMENTS. <br />21.CLEANOUTS. <br />A.INTERIOR CLEANOUTS SHALL BE WALL CLEANOUTS <br />RATHER THAN FLOOR CLEANOUTS UNLESS <br />OTHERWISE INDICATED, SHALL BE READILY <br />ACCESSIBLE, AND SHALL BE CAREFULLY <br />COORDINATED WITH CASEWORK, EQUIPMENT, AND <br />OTHER ITEMS TO AVOID CONFLICT AND MAINTAIN <br />SERVICE CLEARANCE. NOT ALL REQUIRED <br />CLEANOUTS ARE INDICATED ON PLANS. CLEANOUTS <br />SHALL BE PROVIDED AND INSTALLED IN <br />ACCORDANCE WITH SECTION 707 AND SECTION 719 <br />OF THE 2022 CALIFORNIA PLUMBING CODE. SEE <br />SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. <br />B.WHERE POSSIBLE, CLEANOUTS SHALL BE LOCATED <br />IN UNFINISHED AREAS SUCH AS STORAGE ROOMS, <br />CLOSETS, AND JANITORS CLOSETS, ETC. <br />C.PROVIDE ACCESSIBLE CLEANOUTS AT THE BASE OF <br />ALL SOIL/WASTE STACKS. <br />D.EXTERIOR YARD BOXES AND CLEANOUTS SHALL BE <br />INSTALLED IN EXACT LOCATIONS INDICATED ON <br />PLANS. IN THE EVENT OF A CONFLICT OR <br />DISCREPANCY, NOTIFY THE ARCHITECT AT ONCE <br />FOR INSTRUCTION ON HOW TO PROCEED. <br />22.EXTERIOR WATER SHUT-OFF VALVES SHALL BE INSTALLED <br />WITHIN CONCRETE YARD BOXES. YARD BOX COVERS SHALL <br />BE CLEARLY STAMPED WITH "WATER", OR "GAS", AS <br />APPLICABLE. ALL YARD BOXES AND CLEANOUT COVERS <br />SHALL ALIGN WITH SCORED HARDSCAPE JOINTS PER <br />LANDSCAPE PLANS. SEWER CLEANOUT COVERS SHALL BE <br />BRASS, YARD BOX COVERS SHALL BE CONCRETE. REFER TO <br />SPECIFICATIONS FOR ADDITIONAL INFORMATION. <br />23.DRAWINGS ARE DIAGRAMMATIC AND MAY NOT INDICATE ALL <br />REQUIRED OFFSETS, TRANSITIONS AND FITTINGS. PROVIDE <br />ADDITIONAL OFFSETS, TRANSITIONS AND FITTINGS AS <br />REQUIRED IN COORDINATION WITH OTHER TRADES. <br />24.COORDINATE CONSTRUCTION OF ALL PLUMBING WORK <br />WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, <br />ELECTRICAL, CIVIL, AND OTHER DISCIPLINES' WORK SHOWN <br />ON OTHER CONTRACT DOCUMENTS. <br />25.CAREFULLY COORDINATE ALL WORK WITH THE WORK OF <br />OTHER CONTRACTORS AND TRADES PRIOR TO ORDERING <br />OF MATERIALS AND/OR INSTALLATION. IF CONTRACTOR IS IN <br />THE PROCESS OF INSTALLING NEW WORK, AND CONFLICTS <br />WITH EXISTING CONDITIONS OR OTHER TRADES ARISE, <br />NOTIFY THE OWNER’S REPRESENTATIVE AT ONCE FOR <br />INSTRUCTION ON HOW TO PROCEED. <br />26.LOCATIONS SHOWN FOR POINTS OF CONNECTION TO <br />MECHANICAL UNITS AND EQUIPMENT INSTALLED BY OTHER <br />TRADES ARE APPROXIMATE. USING MANUFACTURER’S <br />CERTIFIED DRAWINGS, VERIFY WITH THE INSTALLING <br />CONTRACTOR EXACT PLUMBING REQUIREMENTS, ROUGH-IN <br />LOCATIONS AND CONNECTION POINTS OF ALL EQUIPMENT <br />REQUIRING PLUMBING CONNECTIONS. WHERE PLANS <br />INDICATE ASSOCIATED PLUMBING SERVICE PIPING <br />PENETRATING THROUGH ADJACENT ROOF OR STRUCTURE, <br />MAKE ADJUSTMENT TO PENETRATION LOCATIONS AS <br />NECESSARY TO LIMIT EXPOSED HORIZONTAL PIPING <br />DISTANCE TO MAXIMUM 3’-0” BETWEEN THE PENETRATION <br />LOCATION AND POINT OF CONNECTION TO THE EQUIPMENT. <br />27.ALL VALVES AND STRAINERS SHALL BE FULL SIZE OF PIPE <br />BEFORE REDUCING SIZE TO MAKE CONNECTIONS TO <br />EQUIPMENT. COORDINATE AND PROVIDE ALL PIPING <br />TRANSITIONS REQUIRED FOR FINAL EQUIPMENT <br />CONNECTIONS TO FURNISHED EQUIPMENT. <br />28.CONCRETE HOUSEKEEPING PADS SHALL BE PROVIDED AT <br />ALL OCCURRENCES OF FLOOR MOUNTED EQUIPMENT, <br />INCLUDING BUT NOT LIMITED TO WATER HEATERS, HEAT <br />EXCHANGERS, BOILERS, STORAGE TANKS, PUMPS, AIR <br />COMPRESSORS, AND VACUUM PUMPS. CONCRETE <br />HOUSEKEEPING PADS SHALL BE SIZED AND LOCATED BY <br />THE PLUMBING CONTRACTOR. MINIMUM CONCRETE PAD <br />THICKNESS SHALL BE 4 INCHES. PADS SHALL EXTEND <br />BEYOND THE EQUIPMENT A MINIMUM OF 6 INCHES ON EACH <br />SIDE OR AS INDICATED IN STRUCTURAL DRAWINGS AND <br />SPECIFICATIONS. IT SHALL BE THE RESPONSIBILITY OF THE <br />PLUMBING CONTRACTOR TO COORDINATE SIZE AND <br />LOCATION OF ALL REQUIRED HOUSEKEEPING PADS WITH <br />THE GENERAL CONTRACTOR PRIOR TO BID. SEE <br />STRUCTURAL DRAWINGS AND SPECIFICATIONS FOR <br />ADDITIONAL INFORMATION. <br />29.REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF <br />ALL FIRE RATED ASSEMBLIES. PROVIDE FIRESTOPPING AT <br />ALL PENETRATIONS THROUGH FIRE RETARDANT <br />CONSTRUCTION IN ACCORDANCE WITH SPECIFICATIONS. <br />30.HORIZONTAL SANITARY DRAINAGE PIPING SHALL SLOPE AT <br />1/4" PER FOOT UNLESS OTHERWISE INDICATED. WHERE IT IS <br />IMPRACTICAL TO SLOPE AT 1/4" PER FOOT, PIPING 4" AND <br />GREATER IN SIZE MAY BE INSTALLED AT 1/8" PER FOOT <br />WHEN FIRST APPROVED BY THE ADMINISTRATIVE <br />AUTHORITY. <br />31.HORIZONTAL SANITARY VENT PIPING SHALL BE GRADED TO <br />DRIP BACK BY GRAVITY TO THE WASTE PIPE WHICH IT <br />SERVES. <br />32.HORIZONTAL CONDENSATE PIPING SHALL SLOPE AT 1/8" PER <br />FOOT UNLESS OTHERWISE INDICATED. <br />33.DOMESTIC WATER PIPING AND COMPONENTS SHALL BE <br />PROVIDED AND INSTALLED IN COMPLIANCE WITH <br />CALIFORNIA AB 1953 LEGISLATION (EFFECTIVE JANUARY 1, <br />WHICH LIMITS THE ALLOWABLE LEAD CONTENT IN CERTAIN <br />DOMESTIC WATER SYSTEM COMPONENTS. <br />34.INDUSTRIAL HOT AND COLD WATER MATERIALS AND <br />INSTALLATION, INCLUDING BUT NOT LIMITED TO PIPING, <br />VALVES, INSULATION, COMPONENTS, HANGERS, SEISMIC <br />RESTRAINT, AND DISINFECTION SHALL BE AS SPECIFIED FOR <br />DOMESTIC HOT AND COLD WATER SYSTEMS, <br />RESPECTIVELY. <br />35.DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE <br />GENERAL LOCATION AND ARRANGEMENT OF PIPING. <br />INDICATED LOCATIONS AND ARRANGEMENTS ARE USED TO <br />SIZE PIPE AND CALCULATE FRICTION LOSS, EXPANSION, <br />AND OTHER DESIGN CONSIDERATIONS. INSTALL PIPING AS <br />INDICATED UNLESS DEVIATIONS TO LAYOUT ARE APPROVED <br />ON COORDINATION DRAWINGS. <br />36.PIPING BETWEEN EACH PLUMBING FIXTURE AND THE <br />NEAREST BRANCH OR MAIN PIPING RUN SHALL BE SIZED TO <br />MATCH THE CORRESPONDING FIXTURE SCHEDULE <br />CONNECTION SIZE AT A MINIMUM UNLESS NOTED AS A <br />LARGER SIZE ON PLANS. PIPE HEADERS IN WALLS SERVING <br />BANKS OF FIXTURES SHALL BE FULL LINE SIZE FROM THE <br />UPSTREAM END OF THE BRANCH LINE TO THE END <br />TERMINAL UNLESS OTHERWISE INDICATED. <br />37.PROVIDE SHUTOFF VALVES IN ALL DOMESTIC WATER PIPING <br />SYSTEM BRANCHES IN WHICH BRANCH PIPING SERVES ONE <br />OR MORE FIXTURES. <br />38.ALL EXPOSED PIPING AT WATER HEATING EQUIPMENT <br />(INCLUDING SUPPLIES) SHALL BE INSULATED. <br />39.SHUTOFF VALVES, SHUT-OFF COCKS, WATER CONTROL <br />DEVICES, CLEANOUTS, AND OTHER PIPING <br />APPURTENANCES SHALL BE THE SAME SIZE AS PIPING <br />SERVED UNLESS OTHERWISE INDICATED. <br />40.PLUMBING PIPING SHALL NOT BE RUN THROUGH OR WITHIN <br />CEILING SPACE ABOVE ELECTRICAL ROOMS, <br />TELECOMMUNICATIONS ROOMS, OR ELEVATOR MACHINE <br />ROOMS, EXCEPT FOR BRANCH PIPING SERVING EQUIPMENT <br />IN THESE ROOMS. <br />41.INSTALL PIPING CONCEALED FROM VIEW AND PROTECTED <br />FROM PHYSICAL CONTACT BY BUILDING OCCUPANTS <br />UNLESS OTHERWISE INDICATED. NO PIPING SHALL BE <br />INSTALLED IN EXPOSED LOCATIONS UNLESS SPECIFICALLY <br />NOTED AS SUCH ON PLANS. <br />42.INSTALL PIPING IN A NEAT ORGANIZED LAYOUT <br />COORDINATING WITH OTHER TRADES. <br />43.PROVIDE HANGERS, CLAMPS, ANCHORS AND GUIDES <br />ACCORDING TO SPECIFICATIONS TO PREVENT STRESS ON <br />PIPING. <br />44.INSTALL PIPING SO THAT ALL VALVES, STRAINERS, UNIONS, <br />TRAPS, FLANGES, AND OTHER APPURTENANCES REQUIRING <br />ACCESS ARE ACCESSIBLE. <br />45.UNIONS OR FLANGES SHALL BE INSTALLED AT EACH PIECE <br />OF EQUIPMENT, IN BYPASSES, AND IN LONG PIPING RUNS <br />(100 FEET OR MORE) TO PERMIT DISASSEMBLY FOR <br />ALTERATION AND REPAIRS. <br />46.PROVIDE FLEXIBLE CONNECTORS IN ALL PIPING SYSTEMS <br />WHICH CONNECT TO PUMPS OR OTHER EQUIPMENT WHICH <br />REQUIRE VIBRATION ISOLATION. FLEXIBLE CONNECTIONS <br />SHALL BE PROVIDED AS CLOSE TO THE EQUIPMENT AS <br />POSSIBLE. <br />47.PROVIDE SLEEVES FOR PIPING PENETRATIONS THROUGH <br />CONCRETE OR MASONRY WALLS, FOOTINGS, GRADE BEAMS <br />OR OTHER SIMILAR STRUCTURAL ELEMENTS. SLEEVES <br />SHALL BE MINIMUM 2 INCHES DIAMETER LARGER THAN THE <br />PIPING SERVED. <br />48.PROVIDE EXPANSION LOOPS ON NATURAL GAS AND WATER <br />PIPING AND EXPANSION FITTINGS ON MEDICAL GAS PIPING <br />CROSSING STRUCTURAL EXPANSION JOINTS. <br />49.ALL OUTLETS FOR FUTURE CONNECTIONS SHALL BE <br />INSTALLED SO AS TO PERMIT EASY CONNECTION. ALL <br />PLUGGED OR CAPPED WASTE OUTLETS FOR FUTURE <br />CONNECTIONS SHALL BE INSTALLED AS LOW AS POSSIBLE <br />IN CEILING SPACES. ALL PLUGGED OR CAPPED VENT <br />OUTLETS FOR FUTURE CONNECTIONS SHALL BE INSTALLED <br />AS HIGH AS POSSIBLE IN CEILING SPACES. <br />50.PROVIDE ALL NECESSARY TEMPORARY OR PERMANENT <br />CAPS OR PLUGS FOR PIPING. DO NOT LEAVE PIPING OPEN <br />ENDED. <br />51.NEW POTABLE WATER SYSTEMS SHALL BE DISINFECTED <br />PRIOR TO USE IN ACCORDANCE WITH SECTION 609.9 OF THE <br />2022 CALIFORNIA PLUMBING CODE AND SPECIFICATIONS. <br />52.LAVATORIES IN PUBLIC RESTROOMS SHALL HAVE HOT <br />WATER CONTROLS THAT COMPLY WITH THE FOLLOWING <br />REQUIREMENTS: <br />A.ADA LAVATORIES AND SINKS SHALL BE PROVIDED <br />WITH ADA INSULATED TRAP AND SUPPLY COVERS AS <br />SPECIFIED. <br />57.ADA WATER CLOSETS SHALL BE INSTALLED WITH FLUSH <br />VALVE ACTUATOR HANDLE LOCATED ON THE WHEEL CHAIR <br />ACCESS SIDE OF THE FIXTURE. <br />58.CONTRACTOR SHALL COORDINATE SPECIFIED COUNTER <br />SINKS WITH MILLWORK CONSTRUCTION DRAWINGS PRIOR <br />TO PURCHASE OF ANY PLUMBING FIXTURES, AND SUBMIT <br />MILLWORK SHOP DRAWINGS WITH FIXTURE SHOP <br />DRAWINGS FOR REVIEW AND APPROVAL. <br />ABBREVIATIONS <br />ABV ABOVE <br />AFF ABOVE FINISHED FLOOR <br />AP ACCESS PANEL <br />AW ACID WASTE <br />AV ACID VENT <br />AHJ AUTHORITY HAVING JURISDICTION <br />ATV ATMOSPHERIC VENT <br />CA COMPRESSED AIR <br />CD CONDENSATE DRAIN <br />CX COMMISSIONING <br />CW DOMESTIC COLD WATER <br />DN DOWN <br />ELEC ELECTRICAL <br />(E)EXISTING <br />FCO FLOOR CLEANOUT <br />FD FLOOR DRAIN <br />F.F.E.FINISHED FLOOR ELEVATION <br />FT FOOT, FEET <br />F.U.FIXTURE UNIT(S) <br />F FIRE <br />FS FIRE SPRINKLER <br />G GAS <br />GPM GALLONS PER MINUTE <br />GPH GALLONS PER HOUR <br />HP HORSEPOWER <br />HW DOMESTIC HOT WATER <br />HWR DOMESTIC HOT WATER RETURN <br />HZ HERTZ <br />I.E.INVERT ELEVATION <br />ICW INDUSTRIAL COLD WATER <br />IHW INDUSTRIAL HOT WATER <br />IN WC INCHES WATER COLUMN <br />KW KILOWATT <br />LAV LAVATORY <br />LBS POUNDS <br />MG MEDIUM PRESSURE GAS <br />MIN MINIMUM <br />MAX MAXIMUM <br />NPSHR NET POSITIVE SUCTION HEAD <br />NIC NOT IN CONTRACT <br />NTS NOT TO SCALE <br />OD OVERFLOW DRAIN <br />POC POINT OF CONNECTION <br />POD POINT OF DISCONNECT <br />PRV PRESSURE REDUCING VALVE <br />PSI POUNDS PER SQUARE INCH <br />PCD PUMPED CONDENSATE DRAIN <br />RD ROOF DRAIN <br />SD STORM DRAIN <br />SS SANITARY SEWER <br />SOV SHUT-OFF VALVE <br />▲T DELTA T <br />TDH TOTAL DYNAMIC HEAD <br />TEMP TEMPERATURE <br />TP TRAP PRIMER <br />TYP.TYPICAL <br />UR URINAL <br />VAC VACUUM <br />V VENT <br />VTR VENT THROUGH ROOF <br />W WATER <br />WC WATER CLOSET <br />WCO WALL CLEANOUT <br />NEW EQUIPMENT <br />EXISTING VACUUM <br />EXISTING GAS <br />NEW COLD WATER <br />NEW VACUUM <br />NEW CARBON DIOXIDE <br />NEW ACID VENT <br />NEW HOT WATER <br />NEW SANITARY SEWER <br />NEW SANITARY VENT <br />EXISTING NITROGEN <br />NEW GAS <br />NEW NITROGEN <br />NEW STORM DRAIN <br />NEW OVERFLOW DRAINOD <br />SD <br />SCD <br />NEW GREASE WASTE <br />GW <br />GW <br />NEW NITROUS OXIDE <br />NEW MEDICAL AIR <br />NEW MEDICAL VACUUM <br />N₂O <br />N₂ <br />CO₂ <br />WAGD <br />MV <br />MA <br />VAC <br />CA <br />DI <br />RO <br />G <br />MG <br />IHWR <br />IHW <br />ICW <br />(E)WAGD <br />(E)MV <br />(E)MA <br />(E)N₂O <br />(E)N₂ <br />(E)CO₂ <br />(E)VAC <br />(E)CA <br />(E)DI <br />(E)RO <br />(E)G <br />(E)MG <br />(E)IHWR <br />(E)IHW <br />(E)ICW <br />(E)HWR <br />(E)HW <br />(E)CW <br />(E)V <br />(E)OD <br />(E)SD <br />(E)GW <br />(E)SS <br />SPD <br />PCD <br />CD <br />NEW TRAP PRIMERTP <br />NEW EQUIPMENT <br />(HIDDEN) <br />PIPE OR EQUIPMENT <br />TO BE DEMOLISHED <br />EXISTING (SCREENED <br />BACKGROUND) <br />EXISTING HIDDEN <br />(SCREENED BACKGROUND) <br />EXISTING SANITARY <br />SEWER <br />EXISTING GREASE WASTE <br />EXISTING STORM DRAIN <br />EXISTING OVERFLOW DRAIN <br />EXISTING SANITARY VENT <br />EXISTING COLD WATER <br />EXISTING HOT WATER <br />EXISTING HOT WATER <br />RETURN <br />EXISTING INDUSTRIAL <br />COLD WATER <br />EXISTING INDUSTRIAL <br />HOT WATER <br />EXISTING INDUSTRIAL <br />HOT WATER RETURN <br />EXISTING MEDIUM <br />PRESSURE GAS <br />EXISTING REVERSE <br />OSMOSIS <br />EXISTING DEIONIZED <br />WATER <br />EXISTING COMPRESSED AIR <br />EXISTING CARBON DIOXIDE <br />EXISTING NITROUS OXIDE <br />EXISTING MEDICAL AIR <br />EXISTING MEDICAL VACUUM <br />EXISTING WASTE <br />ANESTHETIC GAS DISPOSAL <br />NEW SANITARY SEWER <br />BELOW GRADE <br />NEW GREASE WASTE <br />BELOW GRADE <br />NEW SUMP PUMP <br />DISCHARGE <br />NEW CONDENSATE DRAIN <br />NEW PUMPED <br />CONDENSATE DRAIN <br />NEW SECONDARY <br />CONDENSATE DRAIN <br />NEW ACID WASTE BELOW <br />GRADE <br />NEW HOT WATER RETURN <br />NEW INDUSTRIAL COLD <br />WATER <br />NEW INDUSTRIAL HOT <br />WATER <br />NEW INDUSTRIAL HOT <br />WATER RETURN <br />NEW MEDIUM PRESSURE <br />GAS <br />NEW REVERSE OSMOSIS <br />NEW DEIONIZED WATER <br />NEW COMPRESSED AIR <br />WASTE ANESTHETIC <br />GAS DISPOSAL <br />LINE TYPES <br />REVISION <br />DETAIL <br />CONTINUATION <br />ENLARGED PLAN <br />REVISED AREA <br />REVISION TAG <br />ANNOTATION SYMBOLS <br />PIPE SIZE <br />4" SS <br />TYP OF 2 <br /> SEE FOR CONT <br />TYP <br />SEE <br />RECONSTRUCTION KEY NOTE <br />DEMOLITION KEY NOTE <br />POINT OF CONNECTION <br />POINT OF DISCONNECTION <br />P0.1 <br />1 <br />P0.1 <br />1 <br />P0.1 <br />1 <br />1 <br />MISCELLANEOUS <br />FIXT-1 <br />EQUIPMENT/FIXTURE CALLOUT <br />PLUMBING SYMBOLS <br />EXISTING ACID VENT <br />EXISTING ACID WASTE(E)AW <br />(E)AV <br />APPLICABLE STANDARDS <br />2022 CALIFORNIA ELECTRICAL CODE (CEC: PART 3 , TITLE 24 , CCR) <br />2022 CALIFORNIA BUILDING CODE (CBC: PART 1 & PART 2 , TITLE 24 , CCR) <br />2022 CALIFORNIA MECHANICAL CODE (CMC: PART 4 , TITLE 24 , CCR) <br />2022 CALIFORNIA PLUMBING CODE (CPC: PART 5 , TITLE 24 , CCR) <br />2022 CALIFORNIA FIRE CODE (CFC: PART 9, TITLE 24, CCR) <br />2022 CALIFORNIA ENERGY CODE (CEC: PART 6, TITLE 24, CCR) <br />2022 CALIFORNIA GREEN BUILDING STANDARDS (PART 11, TITLE 24, CCR) <br />TITLE 19 C.R.R PUBLIC SAFETY STATE FIRE MARSHAL REGULATIONS <br />THE PROJECT SHALL ALSO COMPLY WITH THE APPLICABLE CODES AND <br />STANDARDS OF THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), <br />AND FM GLOBAL REQUIREMENTS. <br />1 <br />1 <br />NEW ACID WASTEAW <br />AW <br />AV <br />FLOOR SINK <br />FLOOR CLEANOUT <br />WATER CLOSET <br />FIXTURE OUTLET <br />URINAL <br />WALL CLEANOUT <br />METER <br />BACK FLOW PREVENTER <br />PUMP <br />CHECK VALVE <br />BALL VALVE <br />UNION <br />BALANCING VALVE <br />GATE VALVE <br />CONTINUATION <br />GAS SHUT-OFF VALVE <br />DIRECTION OF FLOW <br />SLOPE OF PIPE <br />INSTANTANEOUS WATER HEATER <br />SHUT-OFF VALVE <br />SEISMIC JOINT <br />TEMPERATURE AND PRESSURE <br />RELIEF VALVE <br />FLOOR DRAIN <br />MIXING VALVE <br />2% <br />BFP <br />M <br />NEW ARGONAR <br />EXISTING ARGON(E)AR <br />EXISTING OXYGEN(E)O₂ <br />NEW OXYGENO₂ <br />UTILITY TYPE <br />SIZE <br />EQUIPMENT/FIXTURE IDENTIFICATION <br />EQUIPMENT/FIXTURE TYPE <br />OCCURENCE <br />SHEET WHERE PLAN IS DRAWN <br />PLAN IDENTIFICATION <br />PLAN IDENTIFICATION <br />SHEET PLAN DETAIL IS DRAWN <br />DETAIL IDENTIFICATION <br />SHEET WHERE DETAIL IS DRAWN <br />OCCURANCE <br />NEW PIPE FITTING <br />PRESSURE REDUCING VALVE <br />Sheet No. <br />Project <br />Agency Plan Check / Permit No. <br />Petersen Design Project No. <br />Consultant <br />5082.1 <br />652 East Dyer Drive <br />Santa Ana, CA 92705 <br />DYER WAREHOUSE <br />Staging & Set-Up Space <br />Tenant Improvements <br />Sheet Title <br />Revision / Submittal History <br />Scale <br />Status <br />. <br />architecture + planning <br />Agency Approval <br />Petersen Design Architects, Inc. <br />17582 Fiesta Way, Tustin, CA 92780 <br />M: 714.904.6720 E: mike@mpdarch.com <br />www.mpdarch.com <br />Architect's Stamp <br />. <br />255 E. Rincon St., Suite 301 <br />Corona, CA 92879 <br />P 951.340.1977 | F 951.340.1090 <br />www.gossengineering.com <br />CALOFI <br />GI <br />RE <br />NG <br />A <br />E <br />S <br />A <br />M <br />ET <br />SAT E HC A <br />F <br />NIC L <br />ORNI <br />EPR <br />ET <br />RED <br />OF ONAL <br />SSI <br />NE <br />RE <br />I <br />No. M36781 <br />Exp. 3-31-26 <br />YRNEGA.WAHS <br />T <br />Project Number: 125-09-07 <br />Date Signed 10-30-25 <br />Symbols, Designation <br />and Abbreviations <br />P0.1