My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
652 E Dyer Rd - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Dyer Rd
>
652 E Dyer Rd
>
652 E Dyer Rd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2026 1:09:53 PM
Creation date
2/25/2026 1:09:44 PM
Metadata
Fields
Template:
Plan
Permit Number
20187556
30149702
101125942
Full Address
652 E Dyer Rd
Street Number
652
Street Direction
E
Street Name
Dyer
Street Suffix
Rd
Rectangle
ID:
1
Creator:
Import Agent
Created:
2/25/2026 1:09 PM
Modified:
2/24/2026 3:55 PM
ID:
2
Creator:
Import Agent
Created:
2/25/2026 1:09 PM
Modified:
2/24/2026 3:55 PM
ID:
3
Creator:
Import Agent
Created:
2/25/2026 1:09 PM
Modified:
2/24/2026 3:55 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SCALE <br />TRAPEZE HANGER PIPE SUPPORT 1N.T.S. <br />SCALE <br />BARE PIPE PENETRATION THRU NON-RATED WALL 4N.T.S. <br />SCALE <br />PIPE INSULATION THICKNESS 7N.T.S. <br />SCALE <br />SINGLE PIPE HANGER SUPPORT 2N.T.S. <br />SCALE <br />CONDENSATE DRAIN TO TAILPIECE 5N.T.S. <br />SCALE <br />PIPE W/ INSULATION PENETRATION THRU NON-RATED WALL 3N.T.S. <br />SCALE <br />INTERIOR CLEANOUT 6N.T.S. <br />SCALE <br />VENT THRU ROOF 9N.T.S. <br />SCALE <br />-----N.T.S. <br />3/4" CONDENSATE <br />DRAIN IN WALL FROM <br />MECHANICAL FAN COIL <br />ABOVE <br />3/4" BLACK PLASTIC HOSE <br />CHROME PLATED TAILPIECE <br />WITH DRAIN CONN. <br />HOSE CLAMP (TYP.) <br />"P" TRAP <br />WALL <br />SINK/LAV <br />1. THESE THICKNESS ARE BASED ON ENERGY EFFICIENCY CONSIDERATIONS ONLY. ISSUES SUCH AS WATER VAPOR PERMEABILITY OR SURFACE CONDENSATION <br />SOMETIMES REQUIRED VAPOR RETARDERS OR ADDITIONAL INSULATION. <br />TABLE 120.3-A PIPE INSULATION THICKNESS <br />FLUID OPERATING <br />TEMPERATURE <br />RANGE (°F) <br />INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (IN INCHES) <br />CONDUCTIVITY (In <br />Btu-In/h-ft²-°F) <br />MEAN RATING <br />TEMPERATURE (°F)< 1 1 TO < 1.5 1.5 TO < 4 4 TO < 8 8 AND LARGER <br />SPACE HEATING AND SERVICE WATER HEATING SYSTEM (STEAM, STEAM <br />CONDENSATE, REFRIGERANT, SPACE HEATING, SERVICE HOT WATER)MINIMUM PIPE INSULATION REQUIRED (THICKNESS IN INCHES OR R-VALUE) <br />ABOVE 350 0.32-0.34 250 <br />INCH 4.5 5.0 5.0 5.0 5.0 <br />R-VALUE R-37 R-41 R-37 R-27 R-23 <br />251-350 0.29-0.30 200 <br />INCH 3.0 4.0 4.5 4.5 4.5 <br />R-VALUE R-24 R-34 R-35 R-26 R-22 <br />201-250 0.27-0.30 150 <br />INCH 2.5 2.5 2.5 3.0 3.0 <br />R-VALUE R-21 R-20 R-17.5 R-17 R-14.5 <br />141-200 0.25-0.29 125 <br />INCH 1.5 1.5 2.0 2.0 2.0 <br />R-VALUE R-11.5 R-11 R-14 R-11 R-10 <br />105-140 0.22-0.28 100 <br />INCH 1.0 1.5 1.5 1.5 1.5 <br />R-VALUE R-7.7 R-12.5 R-11 R-9 R-8 <br />FLUID OPERATING <br />TEMPERATURE <br />RANGE (°F) <br />INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (IN INCHES) <br />CONDUCTIVITY (In <br />Btu-In/h-ft²-°F) <br />MEAN RATING <br />TEMPERATURE (°F)< 1 1 TO < 1.5 1.5 TO < 4 4 TO < 8 8 AND LARGER <br />SPACE COOLING SYSTEM (CHILLED WATER, REFRIGERANT AND BRINE)MINIMUM PIPE INSULATION REQUIRED (THICKNESS IN INCHES OR R-VALUE) ¹ <br />40-60 0.21-0.27 75 <br />INCH NONRES <br />0.5 <br />RES <br />0.75 <br />NONRES <br />0.5 <br />RES <br />0.75 1.0 1.0 1.0 <br />R-VALUE NONRES <br />R-3 <br />RES <br />R-6 <br />NONRES <br />R-3 <br />RES <br />R-5 R-7 R-6 R-5 <br />BELOW 40 0.20-0.26 50 <br />INCH 1.0 1.5 1.5 1.5 1.5 <br />R-VALUE R-8.5 R-14 R-12 R-10 R-9 <br />RESILIENT CAULKING FIBERGLASS INSULATION <br />1.5 PCF MAX. 100% FILL <br />PIPE <br />PIPE INSULATION <br />WHERE OCCURS <br />PARTITION, CEILING, <br />WALL, ROOF OR FLOOR <br />CONSTRUCTION VARIES <br />25 GA (MIN.) METAL SLEEVE <br />1.PROVIDE PITCH POCKET CONSTRUCTION, ADDITIONAL FLASHING OR WEATHER CAP AS <br />REQUIRED FOR WATERPROOF CONSTRUCTION. DO NOT MECHANICALLY TIE PIPE TO <br />STRUCTURE IN ANY WAY. <br />2.SPACE BETWEEN PIPE AND SLEEVE SHALL BE FREE OF ANY FOREIGN MATERIALS. <br />3.PIPE SHALL NOT CONTACT STRUCTURE AT ANY TIME. WEDGES SHALL NOT BE USED TO <br />MAINTAIN PIPE IN POSITION. <br />4.PIPE MUST BE APPROXIMATELY CENTERED IN OPENING. PROVIDE ADDITIONAL CLEARING <br />FOR POSITIONAL CHANGE OF PIPING DUE TO LOADING OF SYSTEM OPERATION. <br />NOTES: <br />ATTACHMENT TO STRUCTURE <br />3/8" DIA. <br />ROD SIZE <br />1/2" DIA. <br />UP TO 2" <br />PIPE SIZE <br />2 1/2" THRU 3" <br />LOAD (MAX.) <br />PIPE HANGER ROD SIZE <br />60 LBS <br />110 LBS <br />HORIZONTAL DISTANCE <br />CAST IRON <br />MATERIALS <br />PIPE HANGER SPACING <br />5 FEET, EXCEPT 10 FEET WHERE 10 FOOT <br />LENGTHS ARE INSTALLED. <br />COPPER <br />1-1/2 INCHES AND SMALLER, 6 FEET; 2 INCHES <br />AND LARGER, 10 FEET. <br />HANGERS AND SUPPORTS SCHEDULE <br />ATTACHMENT TO <br />STRUCTURE <br />ROD COUPLING <br />PIPE <br />ADD PIPE SLEEVE THAT <br />HAS AN INSIDE DIAMETER <br />1/4" (+-) LARGER THAN <br />OUTSIDE DIAMETER OF <br />BOLT <br />HEAVY DUTY <br />CLEVIS HANGER <br />HANGER <br />THREADED ROD <br />SADDLE <br />AIRCRAFT CABLE (TYP.) <br />45° <br />NOTES: <br />1.HANGER RODS WITH 6 FEET MAXIMUM <br />SPACING. MINIMUM SIZE 3/8"Ø. <br />2.USE EXISTING TRAPEZE SUPPORTS <br />WHERE AVAILABLE. <br />3.COMBINED WEIGHT OF SUPPORTED <br />PIPES IS 10 LBS/FT MAXIMUM. <br />SECURE TO STRUCTURE ABOVE, <br />SEE BELOW STRUCTURE TYPE <br />CHANNEL COMBINATION UNISTRUT P1001 OR <br />APPROVED EQUAL PER SPECIFICATION <br />CONTINUOUS THREADED ROD GRINNELL FIG. 146 <br />OR APPROVED EQUAL PER SPECIFICATION <br />MAXIMUM LENGTH 48" <br />CONCRETE: <br />ROD HANGER ANCHOR SCREW-SIZED FOR LOAD- HILTI, DEWALT, <br />SIMPSON, SAMMYS OR EQUAL-NO SHOT-FIRED HANGERS. <br />STEEL: <br />NIVENT CADDY ROD HANGER, SAMMYS, MORRIS, JUNIOR BEAM <br />CLAMP, OR EQUAL, SIZED FOR LOAD- NO SHOT-FIRED HANGERS. <br />WOOD: <br />ROD HANGER BY POWERS, SAMMYS OR EQUAL-SIZED FOR LOAD <br />FIRE BARRIER CAULK CP25WBX <br />(UL CLASSIFIED & STATE FIRE <br />MARSHAL LISTED)-(TYPICAL) <br />NOTES : <br />1. INSTALLATION SHALL COMPLY WITH THE U.L. FIRE RESISTANCE DIRECTORY <br />VOL. 2 2011 EDITION, SYSTEM NO. W-L-1000 THROUGH PENETRATION <br />FIRESTOP SYSTEM. <br />"3M BRAND" <br />FIRE RATED WALL <br />PROVIDE A MIN. 1/4"Ø BEAD <br />FIRE BARRIER CAULK CP25WBX <br />(UL CLASSIFIED & STATE FIRE <br />MARSHAL LISTED)-(TYPICAL) <br />4"Ø OR SMALLER STEEL PIPE <br />1/4" MAX. ANNULAR SPACE (TYP.) <br />NOTES : <br />1. INSTALLATION SHALL COMPLY WITH THE U.L. FIRE RESISTANCE DIRECTORY <br />FIRESTOP SYSTEM. <br />"3M BRAND" <br />2. DO NOT CUT WALL STUDS WITHOUT UNIVERSITY REPRESENTATIVES' APPROVAL. <br />CLEANOUT TEE <br />WALL CLEANOUT <br />CHROME PLATED STEEL <br />COVER PLATE WITH <br />SECURING SCREW <br />FINISHED WALL <br />SURFACE <br />THREADED <br />CLEANOUT PLUG <br />NOTE: <br />1.VENTS SHALL BE INSTALLED PER CHAPTER 9, SECTION 906.0 OF THE CPC. <br />VERIFY ROOFING <br />MATERIAL SEE <br />ARCH. PLANS <br />PIPE THRU ROOF <br />FIRE STOP ASSEMBLY AS <br />PIPE PENETRATION PROVIDE <br />ABV. ANY FRESH AIR INTAKE <br />COUNTERFLASH CONNECTIONS <br />REQUIRED. <br />FLASHING <br />TOP OF ROOF <br />MIN. 10 FT. FROM OR 3 FT. <br />(ANCHOR DN. W/SET SCREW) <br />FOR DOMESTIC WASTE VENT <br />VANDAL PROOF VENT CAP <br />12 <br />" <br />- <br /> <br />S <br />T <br />A <br />N <br />D <br />A <br />R <br />D <br />VENT FOR DOMESTIC <br />LOCATION SHALL BE <br />WASTE VENTING NOTE: <br />BREAK <br />SINK <br />COUNTER TOP <br />J-BOX W/DISCONNECT <br />SWITCH ON WALL <br />BELOW COUNTER AS <br />HIGH AS POSSIBLE. <br />PROVIDED & INSTALLED <br />BY ELECTRICAL <br />ZURN LEAD COMPLIANT “XL” <br />MODEL Z8860-XL-12-SS TO <br />Z8860-XL-16-SS BRAIDED <br />STAINLESS STEEL FLEX <br />CONNECTOR ON HW SUPPLY <br />IHW-1 <br />INSTANTANEOUS WATER <br />HEATER ON WALL BELOW <br />COUNTER. MOUNT AS HIGH <br />AS POSSIBLE AND IN <br />ACCORDANCE W/ <br />MANUFACTURER'S <br />RECOMMENDATIONS. SET <br />OUTLET TEMP TO 110° F <br />FOR SINKS <br />PPP #MM-5001FCT WATER <br />HAMMER ARRESTOR ON <br />HOT WATER SUPPLY <br />POWER WIRING BY <br />ELECTRICAL ANGLE STOP WITH PPP <br />#MM-5001FCT WATER <br />HAMMER ARRESTOR ON <br />COLD WATER SUPPLY. <br />ZURN LEAD COMPLIANT “XL” <br />MODEL Z8860-XL-12-SS TO <br />Z8860-XL-16-SS BRAIDED <br />STAINLESS STEEL FLEX <br />CONNECTOR ON CW SUPPLY <br />ZURN LEAD COMPLIANT “XL” <br />MODEL Z8860-XL-12-SS TO <br />Z8860-XL-16-SS BRAIDED <br />STAINLESS STEEL FLEX <br />CONNECTOR ON CW SUPPLY <br />SCALE <br />INSTANTANEOUS WATER HEATER 8N.T.S. <br />SCALE <br />-----N.T.S. <br />Sheet No. <br />Project <br />Agency Plan Check / Permit No. <br />Petersen Design Project No. <br />Consultant <br />5082.1 <br />652 East Dyer Drive <br />Santa Ana, CA 92705 <br />DYER WAREHOUSE <br />Staging & Set-Up Space <br />Tenant Improvements <br />Sheet Title <br />Revision / Submittal History <br />Scale <br />Status <br />. <br />architecture + planning <br />Agency Approval <br />Petersen Design Architects, Inc. <br />17582 Fiesta Way, Tustin, CA 92780 <br />M: 714.904.6720 E: mike@mpdarch.com <br />www.mpdarch.com <br />Architect's Stamp <br />. <br />255 E. Rincon St., Suite 301 <br />Corona, CA 92879 <br />P 951.340.1977 | F 951.340.1090 <br />www.gossengineering.com <br />CALOFI <br />GI <br />RE <br />NG <br />A <br />E <br />S <br />A <br />M <br />ET <br />SAT E HC A <br />F <br />NIC L <br />ORNI <br />EPR <br />ET <br />RED <br />OF ONAL <br />SSI <br />NE <br />RE <br />I <br />No. M36781 <br />Exp. 3-31-26 <br />YRNEGA.WAHS <br />T <br />Project Number: 125-09-07 <br />Date Signed 10-30-25 <br />Plumbing Details <br />P5.1
The URL can be used to link to this page
Your browser does not support the video tag.