Laserfiche WebLink
City of Santa Ana Public Library Renovation <br />Smith, Fause & McDonald Inc.Group 4 Architecture Research + Planning, Inc. <br />Conform SetASI #026 – August 72, 20254 Group 4 Project No. 22575-01 <br />SECTION 27 4116-56 INTEGRATED AUDIOVISUAL SYSTEMS AND EQUIPMENT <br />1)Number/signal type 1 single link HDMI (or DVI-D*) <br />2)Connectors 1 female HDMI type A <br />d.Interconnection between transmitter and receiver <br />1)Connectors 1 female RJ-45 per unit <br />2)Termination standard ANSI/TIA T568B <br />3)Signal transmission distance Up to 330' (100 m) using <br />manufacturer’s recommended cabling assembly. <br />e.Video output — receiver <br />1)Number/signal type 1 single link HDMI (or DVI-D*) <br />2)Connectors 1 female HDMI type A <br />3.Manufacturer, provide with with manufacturer’s mounting kits and recommended <br />cabling assemblies: <br />a.Kramer <br />b.Hall Research <br />c.Extron <br />d.Crestron <br />e.Altinex <br />f.Liberty Cable <br />g.Or equal. <br />H.VGA Extender <br />1.Drawing Reference: VGA XTD or as required <br />2.Provide as required to maintain signal integrity over required cable length <br />3.Manufacturers: <br />a.Any as specified for HDMI extenders above. <br />2.13 CONTROL AND CONTROL MEDIA CABLING <br />A.General <br />1.Provide cable with electrical conductors of soft drawn annealed copper, bare or <br />tinned, solid or concentric stranded as applies, conductivity not less than 98 percent <br />of pure copper. <br />2.Comply with applicable Code for insulation, jacket, marking and listing for applicable <br />use. <br />a.Refer to California Electrical Code, Table 725-61. Cable Uses and Permitted <br />Substitutions. <br />b.Manufacturer part number specified is for a Listed Type CM construction to <br />indicate intended cable construction and quality. <br />3.Code requirements take precedence. <br />a.Provide type required by Code at no additional cost to the City. <br />B.High Speed, TIA/TIA Category Cabling <br />1.Drawing Reference:** UTP6-4, where ** denotes cable count <br />2.Construction: <br />a.Provide horizontal copper cable in accordance with: <br />1)EIA ANSI/TIA/EIA-568-B.2 <br />2)UL 444, <br />3)NEMA WC 66 (Performance Standard for Category 6 and Category <br />7 100 Ohm Shielded and Unshielded Twisted Pair) <br />4)ICEA S-90-661 <br />b.UTP (unshielded twisted pair), <br />c.100 ohm impedance <br />d.Four each individually twisted pair, 22 or 24 AWG conductors, <br />1)Color code <br />a)Pair 1 White/Blue Blue