Laserfiche WebLink
City of Santa Ana Public Library Renovation <br />Group 4 Architecture Research + Planning, Inc.Smith, Fause & McDonald Inc. <br />Group 4 Project No. 22575-01 Conform Set – August 2, 2024Bid Set Addendum-03 – June 05 <br />INTEGRATED AUDIOVISUAL SYSTEMS AND EQUIPMENT SECTION 27 4116-57 <br />b)Pair 2 White/Orange Orange <br />c)Pair 3 White/Green Green <br />d)Pair 4 White/Brown Brown <br />e.No shield in the sheath. <br />f.Jacket <br />1)Thermoplastic jacket <br />2)Color: Blue unless otherwise indicated. <br />3)Cable imprinted with manufacturers name or identifier, flammability <br />rating, gauge of conductor, transmission performance rating <br />(category designation) at regular intervals not to exceed 2 feet. <br />4)The word "FEET" or the abbreviation "FT" shall appear after each <br />length marking. <br />5)Provide communications general purpose (CM or CMG), <br />communications plenum (CMP) or communications riser (CMR) <br />rated cabling in accordance with NFPA 70. <br />6)Type CMP and CMR may be substituted for type CM or CMG and <br />type CMP may be substituted for type CMR in accordance with <br />NFPA 70. <br />3.Certification <br />a.Warrantied by the manufacturer to provide Category 6 performance when <br />installed in accordance with applicable EIA/TIA standards and when <br />terminated with the jacks supplied by the Contractor for this Project. <br />4.Performance <br />a.Assembly electrically meets or exceeds EIA ANSI/TIA/EIA-568-B.2 Category <br />6 performance standards <br />5.Manufacturers: <br />a.Berk-Tek LANmark-6 <br />b.Belden/CDT <br />c.Berk-Tek <br />d.Commscope/Systimax <br />e.Commscope/Uniprise <br />f.General Cable <br />g.Mohawk/CDT <br />h.Superior/Essex <br />i.Or equal <br />2.14 CONTROL MEDIA CABLING <br />A.General <br />1.Provide cable with electrical conductors of soft drawn annealed copper, bare or <br />tinned, solid or concentric stranded as applies, conductivity not less than 98 percent <br />of pure copper. <br />2.Comply with applicable Code for insulation, jacket, marking and listing for applicable <br />use. <br />a.Refer to National Electrical Code, Table 725-61. Cable Uses and Permitted <br />Substitutions. <br />b.Manufacturer part number specified is for a Listed Type CM construction to <br />indicate intended cable construction and quality. <br />3.Code requirements take precedence. <br />a.Provide type required by 2016 CEC at no additional cost to the City. <br />B.Low Speed Audiovisual Cabling <br />1.Drawing Reference: AVNet <br />2.1 cable equivalent to a 1 pair, 18 gauge cable suitable for RS-485 (A/V Net) signaling <br />and remote device powering.