My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
26 Civic Center Plz - REV 6 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Civic Center Plz
>
26 Civic Center Plz
>
26 Civic Center Plz - REV 6 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2026 1:27:25 PM
Creation date
2/25/2026 1:26:58 PM
Metadata
Fields
Template:
Plan
Permit Number
20181364
20184057
30146548
40138556
40139543
101117272
101117273
101117274
101117275
101117276
101117286
101120941
101121751
Full Address
26 Civic Center Plz
Street Number
26
Street Name
Civic Center
Street Suffix
Plz
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
City of Santa Ana Public Library Renovation <br />Smith, Fause & McDonald Inc.Group 4 Architecture Research + Planning, Inc. <br />Conform SetASI #026 – August 72, 20254 Group 4 Project No. 22575-01 <br />SECTION 27 4116-64 INTEGRATED AUDIOVISUAL SYSTEMS AND EQUIPMENT <br />2.Type V-2: Synchronization and switching pulse wiring 4 volts peak-to-peak into 75 <br />ohms, 15.62 to 15.75 kHz. <br />3.Type V-3: Color subcarrier wiring 0 to 4 volts peak-to-peak into 75 ohms, 3.57 to <br />4.43 MHz. <br />4.Type V-4: MATV system wiring 0.1 to 1000 uV peak-to-peak into 50 or 75 ohms, 47 <br />to 890 MHz. <br />C.Control Signal Wiring Classifications: <br />1.Type C-1: DC control wiring 0 to 50 volts. <br />2.Type C-2: Synchronous control or data wiring 0 to 40 volts, peak-to-peak. <br />3.Type C-3: AC control wiring 0 to 48 volts, 60 Hz. <br />D.Additional Wiring Classifications: <br />1.Type M-1: DC power wiring 0 to 48 volts. <br />2.Type M-2: AC power wiring greater than 50 volts, 60 Hz. <br />E.Wiring Combinations: <br />1.Except as indicated herein, conduit, wireways and cable bundles shall contain only <br />wiring of a single classification. The following combinations are acceptable in <br />conduit, or cable harnesses. Additional acceptable combinations may be indicated <br />on the Contract Drawings. <br />a.Types A-1, C-1, and M-1. <br />b.Types A-2, C-l, C-2, and M-l, runs less than twenty (20) feet. <br />c.Types A-2, C-1, and M-1. <br />d.Types A-3, C-1, C-2, and M-1. <br />e.Types A-2, V-1, and V-3. <br />f.Types V-1, V-2, V-3, and C-1. <br />g.Types M-2 and C-3. <br />3.4 WIRE AND CABLE INSTALLATION <br />A.Provide permanent identification of run destination at all raceway terminations. <br />B.All wire and cable shall be continuous and splice-free for the entire length of run between <br />designated connections or terminations. <br />C.All shielded cables shall be insulated. Do not permit shields to contact conduit, raceway, <br />boxes, panels or equipment enclosures. <br />D.Within buildings, make splices only in designated terminal cabinets and/or on designated <br />equipment backboards. Outside buildings, make splices only in designated manholes and/or <br />handholes. Protect splices outside of buildings with splicing kits equivalent to Scotchcast Re- <br />enterable. Make splices only with connectors or terminal devices specified herein. <br />Document all splices on Record Drawings. <br />E.Verify that all raceway has been de-burred and properly joined, coupled, and terminated prior <br />to installation of cables. Verify that all raceway is clear of foreign matter and substances prior <br />to installation of wire or cable. <br />F.Inspect all conduit bends to verify proper radius. Comply with Code for minimum permissible <br />radius and maximum permissible deformation.
The URL can be used to link to this page
Your browser does not support the video tag.