My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
26 Civic Center Plz - REV 6 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Civic Center Plz
>
26 Civic Center Plz
>
26 Civic Center Plz - REV 6 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2026 1:27:25 PM
Creation date
2/25/2026 1:26:58 PM
Metadata
Fields
Template:
Plan
Permit Number
20181364
20184057
30146548
40138556
40139543
101117272
101117273
101117274
101117275
101117276
101117286
101120941
101121751
Full Address
26 Civic Center Plz
Street Number
26
Street Name
Civic Center
Street Suffix
Plz
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
City of Santa Ana Public Library Renovation <br />Smith, Fause & McDonald Inc.Group 4 Architecture Research + Planning, Inc. <br />Conform SetASI #026 – August 72, 20254 Group 4 Project No. 22575-01 <br />SECTION 27 4116-66 INTEGRATED AUDIOVISUAL SYSTEMS AND EQUIPMENT <br />E.Make all connections to screw-type barrier blocks with insulated crimp-type spade lugs. Lugs <br />are not required at captive compression terminal type blocks. Provide permanent designation <br />strips designed for use with the terminal blocks provided. Make neat, intelligible markings <br />with indelible markers equivalent to "Sharpie". <br />F.Tin terminated shield drain wires and insulate with heat shrinkable tubing. <br />G.Use only rosin core 60/40 tin/lead solder for all solder connections. <br />H.Dress, lace or harness all wire and cable to prevent mechanical stress on electrical <br />connections. No wire or cable shall be supported by a connection point. Provide service <br />loops where harnesses of different classes cross, or where hinged panels are to be <br />interconnected. <br />I.Termination and buildout resistors and related circuit correction components shall be visible. <br />Do not install in connector shells or internally modify equipment. Show locations on Record <br />Drawings. <br />J.Correct any and all of the following unacceptable wiring conditions: <br />1.Deformed, brittle or cracked insulation. <br />2.Insulation shrunken or stripped further than 1/8" away from the actual point of <br />connection within a connector, or on a punch block. <br />3.Cold solder joints. <br />4.Flux joints. <br />5.Solder splatter. <br />6.Ungrommeted, unbushed, or uninsulated wire or cable entries. <br />7.Deformation or improper radius of wire or cable. <br />3.7 FINISHES <br />A.Finishes and materials for Contractor fabricated assemblies such as racks, custom control <br />panels, brackets, blank panels, equipment mounting in furniture or casework, speaker baffles, <br />speaker grille material and in general any item or component herein which is visible shall <br />adhere to the following: <br />1.Finish shall be as directed by the City's Representative. <br />2.In the event that the City's Representative provides no direction as to finish, finish <br />shall match exactly the surrounding and adjacent surfaces. <br />3.Wooden speaker back boxes and baffles shall be painted flat black if not otherwise <br />finished or stained. <br />3.8 EQUIPMENT ENCLOSURE (RACK) AND EQUIPMENT FABRICATION <br />A.Combustible material, other than incidental trim of indicated equipment, is prohibited within <br />equipment racks. <br />B.Within each equipment enclosure, provide a full-height multi-circuit ground outlet strip with <br />branch circuit count as shown on drawings; locate on the left side of the equipment <br />enclosure, as viewed from the rear. In each enclosure provide number of receptacles <br />required by present and future equipment indicated on drawings, plus at least two spare <br />receptacles. Provide flexible steel raceway and junction box for connection of power service. <br />Bond internal raceway to rack frame.
The URL can be used to link to this page
Your browser does not support the video tag.