Laserfiche WebLink
ECS Pacific, Inc. <br />Project No. 81:1145 <br /> <br />City of Santa Ana Public Library Renovation <br />26 Civic Center Plaza <br />Santa Ana, California 92701 <br /> <br />COLD FLUID-APPLIED WATERPROOFING <br /> <br />07 1416 - 7 <br /> <br /> <br />6. Tensile Strength, ASTM D412, 100-mil sheet: 900 pounds per square inch. <br />7. Extension to Break, ASTM D412: 400 %. <br />8. Recovery from 100 % Extension: <br />a. After 5-minutes: 98 %. <br />b. After 24-hours: 100 %. <br />9. Coating Performance, Crack Bridging: <br />a. 10 Cycles at minus 15°F (minus 26°C): Greater than 1/8-inch. <br />10. After Heat Aging: Greater than 1/4-inch. <br />11. Coating Performance, Weathering, ASTM D822: 5000 hours: no cracking. <br />12. Softening Point, ASTM D36: Greater than 325 ° F (160 ° C). <br />13. Deflection Temperature, ASTM D648: below minus 60 ° (minus 50 ° C). <br />14. Service Temperature: minus 60 ° F to 220 ° F (minus 50 ° C to 105 ° C). <br />15. Hardness, ASTM D2240, Shore A, 77 ° F (25 ° C): 60. <br />16. Permeability to Water Vapor, ASTM E96, Method E, 100 ° F (38 ° C), 100-mil <br />sheet: 0.03 perms. <br />17. Abrasion Resistance, Weight Loss, ASTM D4060: 1.2 mg. <br />18. Adhesion to Concrete, Dry, Elcometer: 350 pounds per square inch. <br />19. Color: Black. <br />C. Primer: <br />1. Solids by Volume: 97% mixed. <br />2. Volatile Organic Compounds (VOC): 20.9 pounds per gallon (36 g/L). <br />D. Bonding agent: <br />1. Solids by Volume: Less than 1 %. <br />2. Volatile Organic Compounds (VOC): 6.4 pounds per gallon (743 g/L). <br />E. Reinforcing scrim: <br />1. Weight: 3 ounces per square yard (100 g/m²). <br />2. Tensile Strength, ASTM D1682: 57.1 pounds (30 kg). <br />3. Elongation, ASTM D1682: 61.65%. <br />4. Mullen Burst Strength, ASTM D3726: 176.8 pounds per square inch (1,215 kPa). <br />5. Trapezoid Tear Strength, ASTM D1117: 16.1 pounds (7.2 kg). <br />PART 3 - EXECUTION <br />3.1 HAZARDOUS MATERIAL ABATEMENT <br />A. Retain industrial hygienist or other consultant to develop plan to remove, contain, <br />capture, collect, and legally dispose of hazardous materials. <br />B. Remove and dispose of hazardous materials in accordance with federal, state, and <br />local restrictions. <br />1. Provide enclosures to contain, capture, and collect hazardous materials. <br />2. Filter hazardous materials from waste water. <br />3. Monitor airborne dust and debris. <br />3.2 EXAMINATION <br />A. Examine substrates, areas, and conditions, with Installer present, for compliance with