21. SUB-CONTRACTORS SHOULD FULLY INFORM THEMSELF WITH THE WORK INVOLVED AND FIELD CONDITIONS. ALL SUBSTRATE <br />PREPARATION AND ANY REQUIRED CEMENTITIOUS FEATHERING / FLOATING SHALL BE INCLUDED. TEST CONCRETE SLAB SUB-STRATES <br />FOR MOISTURE OFF-GASSING PRIOR TO INSTALLATION OF FLOORING AND PROVIDE MANUF. RECOMMENDED SEALANTS WHERE <br />EXCEEDING INDUSTRY AND MANUF. MAX. RECOMMENDED MOISTURE LEVELS. <br />22.WHERE SHEET VINYL INDICATED PROVIDE INTEGRAL COVED BASE. ENSURE TIGHT FIT AT JUNCTION OF FLOOR AND WALLS. <br />PROVIDE 4" RUBBER BASE FOR OTHER TOP-SET INSTALLATIONS AT ALL AREAS SCHEDULED FOR CARPET (WAITING ROOM, <br />HALLWAYS ETC.). <br />STUCCO <br /> 23. APPLY BASE AND TOP COATS EXTERIOR PLASTER ("STUCCO") ON GALVANIZED EXPANDED METAL LATH ON SEALED, TAPED <br />DUPONT TYVEK STUCCO WRAP, PER ICBO RPT. 4000. APPLY 2 LAYERS TYVEK STUCCOWRAP OVER PLYWOOD SHEATHED SHEAR <br />WALLS. APPLY FINISH COLOR ADDITIVE TO ALL FINISH STUCCO MIXES TO ACHIEVE EVEN CONSISTANT FINISH COLOR. USE LA <br />HABRA COLOR STUCCO MIX OR EQUAL APPROVED, IN MANUFACTURER'S STANDARD COLOR, TO BE VERIFIED WITH OWNER. <br />INSTALL STRICTLY PER MANUF.'S INSTRUCTIONS TO ACHIEVE SMOOTH "LIGHT SAND" TEXTURE. USE PRIMERS AS REQUIRED. <br />DIVISION 10 <br />SPECIALTY PRODUCTS <br />1. SCHEDULE OF BATHROOM SPECIALTIES: <br />A.TOILET GRAB BAR 36"x42"x1 1/2" DIA. S/STEEL:BOBRICK B-6897, OR EQUAL (QTY: 2) <br />C.TOILET PAPER HOLDER/SEAT DISPENSER:BOBRICK B-2840, OR EQUAL (QTY: 2) <br />D.LIQUID SOAP DISPENSER:BOBRICK B-306, OR EQUAL (QTY: 2) <br />E.LED MIRROR :BOBRICK B-169 SERIES, OR EQUAL (QTY: 2) <br />F.COMBO TRASH / TOWEL RECEPTACLE:BOBRICK B-36903 (QTY: 2) <br />G.TOWEL DISPENSER:BOBRICK B-4262 (QTY: 6)(CONFIRM LOCN. W/ OWNER) <br />H.LAVATORY TRAPS/ PIPE INSULATION:TRUEBRO INC. PRE-MOULDED PIPE WRAP (WHITE) HANDI LAV-GUARD" #102 <br />(QTY. 5) <br />4. FIRE EXTINGUISHERS / CABINETS: 10 LBS TYPE ABC DRY CHEMICAL, WITH 18 GA. SEMI-RECESSED CABINET WITH PAINTED FINISH, <br />GLASS DOOR AND LOCK, AS POTTER-ROEMER, INC. <br />WINDOW COVERINGS <br />6. PROVIDE VERTICAL WINDOW COVERINGS AT EACH EXISTING EXTERIOR WINDOW AS SPECIFIED BELOW. CONFIRM STYLE, ETC. W/ <br />OWNER PRIOR TO ORDERING: <br />MECHOSHADE THERMOVEIL 1300 SERIES DENSE BASKET WEAVE SHADECLOTH, COLOR: 1320 SHADOW GREY <br />DIVISION 15 <br />PLUMBING NOTES: <br />1. READ W/ MECHANICAL PLUMBING SPECIFICATION DRAWINGS. <br />2. ALL PLUMBING SHALL BE IN ACCORDANCE WITH CPC AND ALL LOCAL CODES AND ORDINANCES. <br />3. CONTRACTOR TO COORDINATE EQUIPMENT CONNECTIONS WITH ALL OTHER TRADES AND <br />SUPPLIERS. INSTALL AND MAKE FINAL CONNECTIONS, FURNISHING CUT-OFF VALVES, P-TRAPS, P.R.V.'S AND PIPING AS REQUIRED. <br />3A. INSTALL SHOCK ABSORBERS IN COLD WATER LINES, AS REQUIRED <br />4. CONNECT TO EXISTING VENT AND WASTE STACKS WHERE POSSIBLE. CAREFULLY COODINATE WORK IN FLOOR WITH LOCATION OF <br />EXISTING UTILITIES. DO NOT DISTURB ADJACENT BUILDINGS DURING WORKING HOURS. <br />5. HOT WATER SUPPLY TO BE CONNECTION TO NEW ELECTRICAL WATER HEATER, OR AS NOTED ON PLUMBING PLANS. <br />6. ALL PIPEWORK SHALL BE CONCEALED IN STUD WALLS ETC. STUB-OUTS SHALL BE MIN. 6" AFF. <br />7. HOT AND COLD WATER PIPING SHALL BE 1/2" DIA. COPPER TYPE "L" PER ASTM B88, INSULATED WITH 1" FIBERGLASS, WITH VAPOUR <br />SEAL ON COLD WATER PIPING. SLEEVE ALL NEW UNDERGROUND PIPING. <br />8. CONDENSATE DRAIN PIPING SHALL BE TYPE "L" COPPER WITH 1" FIBERGLASS INSULATION. <br />9. DRAIN LINES TO BE NO SMALLER THAN STUB-OUT OF FIXTURE ITSELF, OR MIN. 1 1/2" DIA. <br />10. SCREWED PIPE SHALL BE MADE UP WITH PIPE COMPOUND APPLIED TO MALE THREAD, WITH NOT MORE THAN 2 THREADS LEFT <br />EXPOSED. PIPES SHALL BE REAMED AFTER THREADING. <br />11. COPPER JOINTS SHALL BE MADE UP WITH 95-5 SOLDER. <br />12. CLEAN-OUTS SHALL BE AS MANUF. JOSAM ZURN MANUF. CO., OR EQUAL, AND SHALL BE INSTALLED AT ALL BENDS ANGLES AND <br />ENDS OF WASTE AND SEWER LINES. ALL CLEAN-OUTS SHALL BE BROUGHT TO FINISHED FLOOR LEVEL AND SHALL BE PROVIDED WITH <br />SUFFICIENT SPACE FOR RODDING. <br />13. ALL VALVES SHALL BE BRASS, MANUF. BY CRANE, NIBCO, STOCKHAM, LUNKENHEMER, NORDSTRON, GRINNELL OR EQUAL. <br />14. PROVIDE GATE VALVES ON ALL WATER LINES. <br />FIRE SPRINKLER SYSTEM: <br />1. PLANS FOR MODIFICATIONS TO FIXED FIRE PROTECTION EQUIPMENT SHALL BE PREPARED AND SUBMITTED TO THE OWNER & <br />ARCHITECT BY INSTALLING CONTRACTOR AND SHALL BE APPROVED BY THE FIRE PREVENTION BUREAU, OWNER'S INSURANCE <br />ORGANIZATION AND ARCHITECT PRIOR TO INSTALLATION. SPRINKLER CONTRACTOR SHALL BE NOMINATED BY LANDLORD (ONLY). <br />2. COMPLY WITH NFPA 13 AND 24 "STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS. THE BUILDING'S AUTOMATIC <br />SPRINKLER SYSTEM SHALL COMPLY WITH THE U.B.C. STANDARD NO. 38-1, COMBINED SYSTEM. <br />3. COMPLY WITH NFPA 70 "NATIONAL ELECTRICAL CODE" FOR ELECTRICAL CONNECTIONS BETWEEN WIRING AND ELECTRICALLY <br />OPERATED DEVICES. <br />4. VERIFY EXISTING UTILITY LOCATIONS. INSTALL DETECTOR CHECK VALVES AS REQUIRED. COMPLY WITH NFPA 26 FOR DEVICES AND <br />METHODS OF VALVE SUPERVISION. <br />5. INSTALL FULLY CONCEALED HEADS IN ALL AREAS, EXCEPT SEMI-RECESSED CHROME FINISH HEAD WITH WHITE FINISHED <br />ESCUTCHEON MAY BE USED IN ELECTR. UTILITY ROOMS ONLY. <br />DIVISION 16 <br />SEE ELECTRICAL SPECIFICATIONS. ON SEPARATE DRAWINGS <br />1. COORDINATE WITH LANDLORD'S FIRE ALARM SUB-CONTRACTOR. THE FIRE ALARM SYSTEM SHALL CONFORM TO ARTICLE 760 <br />CALIFORNIA ELECTRICAL CODE. <br />DIVISION 16 <br />SEE ELECTRICAL SPECIFICATIONS. ON SEPARATE DRAWINGS <br />LIGHT FIXTURES: <br />UNLESS DIRECTED OTHERISE; 2' X 4' INDIRECT LUMINAIRE, PERFORATED LIGHT SHIELD, CENTERMOUNT CONFIGURATION, STANDARD <br />WHITE - SEE E-SERIES PLAN / SPECS <br />LIGHT SWITCH: LEVITON #5501, WHITE <br />ELECTRICAL WALL OUTLET: <br />1.LEVITON DUPLEX OUTLET #5242, 20A, 120V, WHITE OR RED FOR EMERGENCY POWER OUTLETS <br />ELECTRICAL WALL OUTLET - DEDICATED: <br />1.LEVITON DUPLEX OUTLET #5242, 20A, 120V, WHITE <br />TELEPHONE BACKBOARD: <br />1.4'-0" X 4'-0" ¾" CDX PLYWOOD BACKBOARD <br />2.TELEPHONE FEEDER <br />3.ONE DEDICATED 110V DUPLEX OUTLET <br />1 <br />A5.1 <br />SPECIFICATIONS <br />SCALE: NTS <br />A-5.1 <br />Dr <br />. <br /> <br />K <br />a <br />l <br />a <br />n <br />t <br />a <br />r <br />i <br /> <br />D <br />e <br />n <br />t <br />a <br />l <br /> <br />O <br />f <br />f <br />i <br />c <br />e <br /> <br />SHEET NO. <br />2509 <br />REVISIONS: <br />5/30/2025DATE: <br />PROJECT NO. <br />DE <br />N <br />T <br />A <br />L <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br /> <br />T <br />E <br />N <br />A <br />N <br />T <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br />22 <br />2 <br />2 <br /> <br />S <br />. <br /> <br />B <br />r <br />i <br />s <br />t <br />o <br />l <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />A <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4