My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2109 & 2111 N Poinsettia St - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Poinsettia St
>
2111 N Poinsettia St
>
2109 & 2111 N Poinsettia St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2026 5:00:11 AM
Creation date
3/3/2026 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
101125320
Full Address
2111 N Poinsettia St
Street Number
2111
Street Direction
N
Street Name
Poinsettia
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1/2" GYPSUM BOARD <br />INTERIOR FINISH BY <br />INTERIOR DESIGN,U.N.O <br />INTERIOR INTERIOR <br />WOOD/COMPOSITE/METAL SIDING <br />GRADE "D" BUILDING PAPER <br />(VAPOR BARRIER) <br />PLYWOOD SHEATHING (PER <br />STRUCTURAL DESIGN) MIN. <br />MIN. 3/8" CDX PLYWOOD <br />2X FRAMING <br />INSULATION PER T-24 <br />1/2" GYPSUM BOARD <br />INTERIOR FINISH BY <br />INTERIOR DESIGN,U.N.O <br />EXTERIOR INTERIOR <br />GRAVEL BASE <br />10 MIL POLY VAPOR <br />DIFFUSION RETARDER IS <br />EXTENTED UNDER FOOTING <br />MORTAR BED 3/4" TO 1 1/4" <br />CONCRETE SLAB <br />BOND COAT <br />CERAMIC TILE <br />BOTTOM OF OVERFLOW <br />TO BE 2" ABOVE LOWEST <br />POINT OF DECK TYPICAL <br />2"Ø ABS DOWNSPOUT <br />WHERE OCCURS <br />OVERFLOW SCUPPER 3X <br />AREA OF ROOF DRAIN <br />WATERPROOF DECK <br />SLOPE MIN. 1/4"/FT. <br />TYPICAL <br />DECK DRAIN, 3"Ø <br />4' <br />' <br />* <br />WHEN WALL IS SHEATHED ON THE <br />EXTERIOR, LAP BOTH LAYERS OF <br />BUILDING PAPER OVER THE WEEP <br />SCREED FLANGE <br />EXPOSED EARTH <br />MIN. 26 GA. G.S. PLASTER WEEP <br />SCREED W/ 3-1/2" VERTICAL <br />NAILING FLANGE <br />SIDING OVER 1 <br />LAYERS GRADE 'D' <br />PAPER <br />PRESSURE TREATED WOOD PLATE <br />SEAL TO CONCRETE W/ CONT. <br />BEAD OF SEALANT <br />WHEN WALL IS SHEATHED ON THE <br />EXTERIOR, LAP BOTH LAYERS OF <br />BUILDING PAPER OVER THE WEEP <br />SCREED FLANGE <br />CONC. SLAB <br />FOOTING OR <br />CURB <br />CONCRETE OR IMPERVIOUS <br />SURFACE <br />MIN. 26 GA. G.S. PLASTER WEEP <br />SCREED W/ 3-1/2" VERTICAL <br />NAILING FLANGE <br />SIDING OVER 1 <br />LAYERS GRADE 'D' <br />PAPER <br />PRESSURE TREATED WOOD PLATE <br />SEAL TO CONCRETE W/ CONT. BEAD <br />OF SEALANT <br />CONC. SLAB <br />FOOTING OR <br />CURB <br />5% <br />4' <br />' <br /> <br />M <br />I <br />N <br />. <br />TO <br /> <br />F <br />I <br />N <br />. <br /> <br />N <br />AT <br />U <br />R <br />A <br />L <br /> <br />G <br />R <br />A <br />D <br />E <br />8" <br />. <br />2' <br />' <br /> <br />M <br />I <br />N <br />. <br />2% <br />8" <br />. <br />FLOOR FINISH, SEE <br />SCHEDULE <br />SEE STRUCT. DWGS FOR <br />SLAB UNDER LAYER <br />FACE OF STUD <br />PORCH SLAB <br /> <br /> <br />1/ <br />2 <br />' <br />' <br />ISOLATED SLAB FROM <br />CONC. SEE STRUCT. <br />ROOF JOIST, SEE <br />STRUCC T.FOR MORE <br />INFORMATIONS. <br />ROOFING <br />30# BUILDING PAPER OVER <br />PLYWOOD SHEATHING OVER <br />RADIANT BARRIER OVER <br />RAFTERS PER STRUCTURAL DWGS <br />RIDGE/HIP CAP <br />RIDGE/HIP BEAM <br />NOTE: <br />REFER TO ROOF TILE MANUFACTURES SPECIFICATIONS <br />FOR INSTALLATION OF TILE <br />ROOF JOIST, SEE <br />STRUCT.FOR MORE <br />INFORMATIONS. <br />12" LENGTH ROOF SHEATHING <br />SWEAT SHEET <br />CONT. METAL VALLEY <br />FLASHING PER TILE <br />MANUFACTURE <br />ROOF TILE <br />METAL CLEATS <br />AT 12" O.C. <br />NOTE: <br />THE VALLEY FLASHING MUST HAVE A SPLASH DIVERTER <br />RIB NOT LESS THAN 1" HIGHT AT THE FLOW LINE, <br />FORMED AS PART OF THE FLASHING MUST HAVE AN <br />OVERLAP OF NOT LESS THAN 4 INCHES <br />PENETRATIONS & INTERUPTIONS AT METAL VALLEY <br />FLASHING NOT PERMITTED. METAL CLEATS AT 12" O.C. <br />REFER TO ROOF TILE MANUFACTURES SPECIFICATIONS <br />FOR INSTALLATION OF TILE <br />26-GUAGE MINIMUM GALVANIZED ROOF FLASHING. (CRC <br />R903.2) <br />ROOF UNDERLAYMENT <br />AIR BAFFLE <br />1/2" GYPSUM <br />CEILING BOARD <br />GUTTER & DOWNSPOUT <br />26 GA. GALV. PRIMED <br />& PAINTED <br />2 LAYERS 30# FELT OVER <br />PLYWOOD SHEATHING <br />ROOF SHEATHING <br />MIN. 1" AIR SPACE <br />2X ROOF RAFTER <br />SOFFIT VENT <br />(3)-3"ø SCREEN VENTS <br />BETWEEN RAFTER <br />RES-2025-1703-SCND <br />JUL 05, 2025 <br />©2025Sheet No. <br />Rev. <br />Application No: <br />Date <br />Design by <br />TRINH HA <br />Date Rev. <br />Pr <br />o <br />j <br />e <br />c <br />t <br />: <br />1 12-17-2025 BLDG comments <br />01-A-300 <br />PO <br />I <br />N <br />S <br />E <br />T <br />T <br />I <br />A <br /> <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />MA <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br /> <br />2 <br />1 <br />0 <br />9 <br /> <br />N <br /> <br />P <br />o <br />i <br />n <br />s <br />e <br />t <br />t <br />i <br />a <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />DE <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br /> <br />2 <br />1 <br />1 <br />1 <br /> <br />N <br /> <br />P <br />o <br />i <br />n <br />s <br />e <br />t <br />t <br />i <br />a <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />na <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />ARCHITECTURAL <br />DETAILS <br />3INTERIOR WALL <br />2EXTERIOR WALL <br />4DOOR HEAD/JAM <br />5DOOR JAM AT EXT. WALL <br />6WINDOW HEAD-STUCCO <br />7WINDOW JAM-STUCCO <br />8WINDOW SILL -STUCCO-TRIM <br />9WINDOW SILL-SHOWER <br />10CERAMIC TILE / CONCRETE <br />11DECK DRAIN <br />1WEEP SCREET12HOUSE TO PORCH <br />13RIDGE / HIP DETAIL <br />14ROOF VALLEY DETAIL <br />1" = 1'-0"15VENT THROUGH ROOF
The URL can be used to link to this page
Your browser does not support the video tag.