My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2109 & 2111 N Poinsettia St - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Poinsettia St
>
2111 N Poinsettia St
>
2109 & 2111 N Poinsettia St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2026 5:00:11 AM
Creation date
3/3/2026 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
101125320
Full Address
2111 N Poinsettia St
Street Number
2111
Street Direction
N
Street Name
Poinsettia
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1. PROVIDE FIRE BLOCKING IN CONCEALED SPACES 10' O.C. HORIZONTAL, VERTICALLY AT THE <br />CEILING AND FLOOR LEVELS, CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES, <br />CONCEALED SPACES BETWEEN STAIR AND LANDING, OPENINGS AROUND VENTS, PIPES, DUCTS, <br />CABLES, WIRES, CHIMNEYS AND FIREPLACES, CRC R302.11. <br />2. ALL WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR <br />FOUNDATION WALLS AND ARE LESS THAN 8" TO THE EXPOSED GROUND SHALL BE PRESSURE <br />TREATED OR NATURALLY DURABLE TO DECAY, CRC R317.2(2). <br />3. ALL WALLS TO BE SMOOTH FINISH U.N.O. <br />4. CONTRACTOR TO INCLUDE ALL FINISH AND COLOR SPECIFIED BY OWNER AND INTERIOR <br />DESIGNER. <br />5. CONTRACTOR TO VERIFY W/ OWNER'S INTERIOR DESIGNER FOR MATERIAL SELECTION AND <br />COLOR PRIOR TO FINAL PRICING AND CONSTRUCTION. <br />6. MIN. 3/8" CDX PLYWOOD THROUGH-OUT @ OUTSIDE FACE OF WALL. <br />7. CONTRACTOR TO INCLUDE INSULATION OF CLOSET ORGANIZER. (SELECTED BY OWNER). <br />8. CONTRACTOR TO VERIFY ALL OWNER'S APPLIANCE MANUAL SPEC. PRIOR TO CONSTRUCTION. <br />9. DESIGN BUILT CABINET TO FIT. <br />10. ALL INTERIOR, DOOR, WINDOW SIDE, HEAD AND SILL TO BE MOLDING. <br />11. EXTERIOR CONCRETE LANDING TO COMPLY 2022 CRC R311.3 <br />A. THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE <br />WIDTH OF EACH LANDING SHALL BE NOT LESS THAN THE DOOR <br />SERVED. EVERY LANDING SHALL HAVE A DIMENSION OF NOT LESS THAN 36 INCHES MEASURED <br />IN THE DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR <br />LANDINGS SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS HORIZONTAL (2 <br />PERCENT). <br />B. LANDINGS AT THE REQUIRED DOOR SHALL NOT MORE THAN 1 1/2 INCHES LOWER THAN <br />THE TOP OF THE THRESHOLD. EXCEPTION: THE LANDING SHALL BE <br />NOT MORE THAN 7 3/4 INCHES BELOW THE TOP OF THE THRESHOLD PROVIDED <br />THE DOOR DOES NOT SWING OVER THE LANDING <br />12. GROUND ADJACENT TO THE FOUNDATION SHALL FALL A MINIMUN OF 8 INCHES WITHIN THE <br />FIRST 10 FEET MEASURE PERPENDICULAR TO THE FACE OF THE FOUNDATION WALL. (CRC <br />R401.3) <br />13. BOTH ADU AND PRIMARY DWELLING ROOF MUST MATCH AND BE SUBSTANTIALLY SIMILAR IN <br />DESIGN, PITCH, COLOR, MATERIAL AND TEXTURE. <br />14. NEW FASCIAS OF ADU/JADU TO MATCH EXISTING ONES. <br />GRADE <br />0' -0" <br />ADU 1ST. F.F <br />1' -0" <br />ADU 1ST. TOP PL. <br />10' -0" <br />ADU APPX. HEIGHT <br />14' -6" <br />BU <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />M <br />A <br />X <br />. <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />14 <br />' <br />- <br />6 <br />" <br />1' <br />- <br />0 <br />" <br />ATTIC <br />6 <br />01-A-201 <br />6 <br />01-A-201 <br />R15 INSULATION <br />PER T24 <br />TYP. <br />(N)ADU -BATH #2 <br />9'-0" CL'G <br />TILE <br />(N)ADU -LIVING AREA <br />VAULTED CEILING <br />WOOD <br />F.A.U.R38 INSULATION <br />PER T24 <br />R21 INSULATION <br />PER T24 <br />VAULTED CEILING <br />(N)ADU -HALLWAY <br />9'-0" CL'G <br />WOOD <br />85 <br />86 <br />R15 INSULATION <br />PER T24 <br />84 <br />85 <br />30" <br />N-C <br />N-D <br />N-1 30 <br />861'-6" <br />1'-6" <br />87 88 <br />89 7090 <br />36 <br />GRADE <br />0' -0" <br />ADU 1ST. F.F <br />1' -0" <br />ADU 1ST. TOP PL. <br />10' -0" <br />ADU APPX. HEIGHT <br />14' -6" <br />5 <br />01-A-201 <br />5 <br />01-A-201 <br />EE&ROBU <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />M <br />A <br />X <br />. <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />14 <br />' <br />- <br />6 <br />" <br />1' <br />- <br />0 <br />" <br />TYP. <br />TYP. <br />(N) SKYLIGHT <br />EVALUATION <br />REPORT NUMBER <br />199 OR EQUAL <br />1'-6"1'-6" <br />36 <br />38 TYP. <br />70 <br />71 <br />N-A <br />N-C N-C <br />N-A <br />73 <br />72 <br />1.1 1.2 <br />1.4 1.5 <br />6'-0" <br />3' <br />- <br />6 <br />" <br />3' <br />- <br />6 <br />" <br />3' <br />- <br />6 <br />" <br />3' <br />- <br />6 <br />" <br />6'-0" <br />7676 <br />5' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />3'-0"3'-0" <br />5' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />4:12 <br />4:12 <br />4: <br />1 <br />2 <br />4: <br />1 <br />2 <br />GRADE <br />0' -0" <br />ADU 1ST. F.F <br />1' -0" <br />ADU 1ST. TOP PL. <br />10' -0" <br />ADU APPX. HEIGHT <br />14' -6" <br />6 <br />01-A-201 <br />6 <br />01-A-201 <br />(N) SKYLIGHT <br />EVALUATION <br />REPORT NUMBER <br />199 OR EQUAL <br />TYP. <br />BU <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />M <br />A <br />X <br />. <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />14 <br />' <br />- <br />6 <br />" <br />1' <br />- <br />0 <br />" <br />TYP. <br />EE&RO <br />16.1 <br />30 <br />73 <br />71 <br />72 <br />1.4 <br />1.1 <br />1'-6" <br />1'-6" <br />7' <br />- <br />0 <br />" <br />2'-4" <br />N-D N-D <br />N-8 <br />3' <br />- <br />6 <br />" <br />3' <br />- <br />6 <br />" <br />5'-0" <br />3' <br />- <br />6 <br />" <br />3' <br />- <br />6 <br />" <br />5'-0" <br />4: <br />1 <br />2 <br />38 <br />36TYP. <br />70 <br />3:12 <br />GRADE <br />0' -0" <br />ADU 1ST. F.F <br />1' -0" <br />ADU 1ST. TOP PL. <br />10' -0" <br />ADU APPX. HEIGHT <br />14' -6" <br />BU <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />M <br />A <br />X <br />. <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />14 <br />' <br />- <br />6 <br />" <br />1' <br />- <br />0 <br />" <br />6 <br />01-A-201 <br />6 <br />01-A-201 <br />(N) SKYLIGHT <br />EVALUATION <br />REPORT NUMBER <br />199 OR EQUAL <br />SOLAR PANEL <br />TYP. <br />1 <br />13637TYP. <br />38 <br />1'-6"1'-6"1'-6" <br />1.5 <br />7' <br />- <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />7'-0"8'-0" <br />7' <br />- <br />0 <br />" <br />30 <br />16.116.1 <br />71 <br />4:124:12 <br />4: <br />1 <br />2 <br />4:12 <br />GRADE <br />0' -0" <br />ADU 1ST. F.F <br />1' -0" <br />ADU 1ST. TOP PL. <br />10' -0" <br />ADU APPX. HEIGHT <br />14' -6" <br />5 <br />01-A-201 <br />5 <br />01-A-201 <br />BU <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />M <br />A <br />X <br />. <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />14 <br />' <br />- <br />6 <br />" <br />(N) SKYLIGHT <br />EVALUATION <br />REPORT NUMBER <br />199 OR EQUAL <br />1' <br />- <br />0 <br />" <br />TYP. <br />TYP. <br />36 38 TYP. <br />70 <br />71 <br />1'-6"1'-6"1'-6" <br />16.1 <br />30 <br />73 <br />72 <br />N-1 <br />N-B <br />N-3 <br />2'-6" <br />4' <br />- <br />0 <br />" <br />3' <br />- <br />0 <br />" <br />7' <br />- <br />0 <br />" <br />3'-0" <br />75 <br />16.1 16.1 <br />4: <br />1 <br />2 <br />4:12 4:12 <br />75 <br />72 <br />GRADE <br />0' -0" <br />ADU 1ST. F.F <br />1' -0" <br />ADU 1ST. TOP PL. <br />10' -0" <br />ADU APPX. HEIGHT <br />14' -6" <br />5 <br />01-A-201 <br />5 <br />01-A-201 <br />BU <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />M <br />A <br />X <br />. <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />14 <br />' <br />- <br />6 <br />" <br />1' <br />- <br />0 <br />" <br />84 <br />86 <br />86 <br />R15 INSULATION <br />PER T24R15 INSULATION <br />PER T24 <br />85 <br />858585 <br />ATTIC <br />(N)ADU -BEDROOM #1 <br />VAULTED CEILING <br />WOOD <br />(N)ADU -BATH #1 <br />9'-0" CL'G <br />TILE <br />(N)ADU -BEDROOM #2 <br />VAULTED CEILING <br />WOOD <br />R38 INSULATION <br />PER T24 <br />R21 INSULATION <br />PER T24 <br />VAULTED CEILINGVAULTED CEILING <br />85 <br />N-A N-A N-D <br />1'-6"1'-6" <br />38 7089 90 <br />87 88 <br />80808081 <br />(N)ADU -BATH #2 <br />9'-0" CL'G <br />TILE <br />CLOSET <br />RES-2025-1703-SCND <br />JUL 05, 2025 <br />©2025Sheet No. <br />Rev. <br />Application No: <br />Date <br />Design by <br />TRINH HA <br />Date Rev. <br />Pr <br />o <br />j <br />e <br />c <br />t <br />: <br />1 12-17-2025 BLDG comments <br />01-A-201 <br />PO <br />I <br />N <br />S <br />E <br />T <br />T <br />I <br />A <br /> <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />MA <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br /> <br />2 <br />1 <br />0 <br />9 <br /> <br />N <br /> <br />P <br />o <br />i <br />n <br />s <br />e <br />t <br />t <br />i <br />a <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />DE <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br /> <br />2 <br />1 <br />1 <br />1 <br /> <br />N <br /> <br />P <br />o <br />i <br />n <br />s <br />e <br />t <br />t <br />i <br />a <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />na <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />DETACHED ADU - <br />ELEVATIONS & <br />SECTIONS <br />ELEVATION & SECTION NOTES <br />ELEVATION & SECTION KEYNOTES <br />1.1 RELOCATED (E) ELECTRICAL METER FOR MAIN HOUSE, 200 AMP, WITH 225 AMP BUS-RATING <br />1.2 (N) ELECTRICAL METER FOR DETACHED ADU, 200 AMP, WITH 225 AMP BUS-RATING <br />1.4 (N) ELECTRICAL SUB PANEL DETACHED ADU, 200 AMP. WITH 225 AMP BUS-RATING <br />1.5 (N) 60AMP SUBPANEL FOR ADU ESS SYSTEM <br />16.1 (N) LANDING. 1 1/2" BELOW THRESHOLD.MINIMUM 36" IN DEPTH. MIN. 2% SLOPE AWAY <br />FROM BUILDING. <br />30 (N) AC UNIT ON 3" THIK. CONCRETE PAD PER T-24. (SHALL BE VERIFIED AND APPROVED BY <br />THE BUILDING INSPECTOR PRIOR TO INSTALLATION) <br />36 O'HAGIN ROOF VENT <br />37 SOLAR PANELS LOCATION, DESIGN BY OTHER, SEE T-24 <br />38 (N) SKYLIGHT EVALUATION REPORT NUMBER 199 <br />70 (N) ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY CERTAINTEED ICC-ESR# <br />3537. COLOR & TEXTURE TO MATCH EXISTING HOUSE. EQUAL. <br />71 (N) FASCIA & TRIMMING - PAINT TO MATCH EXISTING HOUSE <br />72 STUCCO WALL & PAINT TO MATCH EXISTING <br />73 (N) 2 1/2" VINYL MOLDING TRIM FOR ALL WINDOWS TO MATCH EXISTING, TYP. <br />75 TEMPERED GLASS <br />76 TEMPERED, OBSCURED GLASS <br />80 (N) FOOTING PER STRUCT. <br />81 (N) CONCRETE SLAB PER STRUCT. <br />84 WEEP SCREED FOR STUCCO OR DRIP CAP FLASHING FOR SIDING, 2'' MIN. ABOVE PAVED <br />AREAS, 8'' MIN. ABOVE NATURAL GRADE. <br />85 (N) 2x STUD WALL PER STRUCT. <br />86 WALL INSULATION PER T-24 <br />87 (N) CEILING JOISTS PER STRUCT. <br />88 CEILING INSULATION PER T-24 <br />89 (N) ROOF RAFTER PER STRUCT. <br />90 ROOF INSULATION PER T-24 <br />1/4" = 1'-0"5(N) ADU SECTION A-A <br />1/4" = 1'-0"4ADU - EAST ELEVATION 1/4" = 1'-0"2ADU - SOUTH ELEVATION <br />1/4" = 1'-0"1ADU - NORTH ELEVATION1/4" = 1'-0"3ADU - WEST ELEVATION <br />1/4" = 1'-0"6(N) ADU SECTION B-B