F.A.U <br />W/H <br />EP <br />GD <br />W/D <br />El <br />e <br />c <br />. <br />REF <br />30" <br />CLR. <br />30" <br />CLR. <br />GD <br />1. PROVIDE HOUSE STREET NUMBER VISIBLE AND LEGIBLE FROM STREET <br />2. PROVIDE MIN. 2% SLOPE AT FLAT ROOF AND DECK. <br />3. FINISH END WALLS OF CABINETS FLANKING OPENING TO MATCH CABINET FACE. PRIME & <br />PAINT EXPOSED GYP. BD. WALL TO MATCH WALLS. INSTALL MATCHING BASE BD. <br />4. EXTEND FLOORING UNDER APPLIANCES RESTING ON FLOOR. <br />5. SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUB WITH SHOWER HEADS SHALL BE <br />FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 6 FEET <br />ABOVE FLOOR. <br />6. WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED EQUAL TO 70 INCHES <br />ABOVE DRAIN INLET AT SHOWERS OR TUB WITH SHOWERS. PROVIDE APPROVED SHATTER- <br />RESISTANT MATERIALS FOR SHOWER ENCLOSURE AND WINDOWS IF SILL IS LESS THAN 5'-0" <br />ABOVE TUB OR SHOWER FLOOR. <br />7. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL, UNO. <br />8. CEILING HEIGHTS INDICATED ARE MEASURED FROM FINISH FLOOR TO BOTTOM OF CEILING <br />FINISH. <br />9. SMOKE DETECTORS WILL BE PROVIDED PER CHAPTER 3 CRC. THE SMOKE DETECTOR WILL BE <br />HARD WIRED WITH BATTERY BACK-UP AND LOCATED (1) IN EACH BEDROOM, HALLWAYS <br />OUTSIDE BEDROOMS, AND ON EACH STORY. SMOKE DETECTOR ALARM SOUND MUST BE <br />AUDIBLE IN SLEEPING AREAS WHICH MAY REQUIRE INTERCONNECTED SMOKE DETECTORS <br />WITHIN THE UNIT. SEE UTILITY PLANS FOR LOCATIONS. INSTALL AND LOCATE PER MFGR. <br />LISTED REQUIREMENTS. <br />10. SMOKE DETECTOR SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARM <br />WILL ACTIVATE ALL ALARMS. <br />11. SMOKE ALARM AND DETECTORS WILL BE INSTALLED AND MAINTAINED ACCORDING TO <br />MANUFACTURER'S INSTRUCTIONS. <br />12. PROVIDE CARBON MONOXIDE DETECTOR ALARMS ON CEILINGS OR WALLS OUTSIDE <br />SLEEPING ROOMS PER CHAPTER 3 CRC. A DETECTOR IS REQUIRED ON EACH FLOOR <br />13. BATHROOM FANS MUST BE ENERGY STAR W/ HUMIDISTAT CONTROLLER AND MUST BE <br />DUCTED TO THE EXTERIOR OF THE BUILDING <br />14. ALL NEW WINDOWS TO BE DUAL PANES TO MEET CURRENT ENERGY STANDARD <br />REQUIREMENTS. <br />15. ALL WALL ARE 2X4 @16" O.C. U.N.O. <br />16. PROVIDE BACKING FOR ALL ACCESSORIES, FIXTURES AND WINDOW COVERINGS. <br />17. NO HEATING, COOLING, OR INSULATION IN GARAGE. <br />18. PROVIDE TWO LAYERS OF GRADE DOOR 60-MINUTE GRADE D PAPER OVER ALL WOOD <br />BASE SHEATHING AT EXTERIOR WALLS. <br />19. A MINIMUM 26 GAUGE, CORROSION RESISTANT OR PLASTIC WEEP SCREED WITH A <br />MINIMUM VERTICAL FLANGE OF 3½ INCHES SHALL BE PROVIDED AT OR BELOW <br />FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS. SCREED SHALL BE A MINIMUM OF 4 <br />INCHES ABOVE EARTH OR 2 INCHES ABOVE PAVED AREAS. (CRC R703.7.2.1) <br />20. CEILING SHALL NOT BE USED FOR STORAGE PURPOSES <br />21. BOTH ADU AND PRIMARY DWELLING ROOF MUST MATCH AND BE SUBSTANTIALLY <br />SIMILAR IN DESIGN, PITCH, COLOR, MATERIAL AND TEXTURE. <br />22. PER SECTION 301.1.1 CALGREEN AND CIVIL CODE 1101.3(C), ALL NON-COMPLIANT <br />PLUMBING FIXTURES WITHIN THIS RESIDENCE SHALL BE REPLACED WITH WATER- <br />CONSERVING PLUMBING FIXTURES. <br />23. THE HPWH WILL BE INSTALLED ACCORDING TO MANUFACTURER’S REQUIREMENTS <br />24. PRESCRIPTIVE INSTALLATIONS SHALL BE INDOORS AND ON A RIGID R-10 INSULATED <br />SURFACE. HPWH MUST MEET NEEA TIER3ORHIGHER. [150.2(B)1HIII] <br />XX DOOR TYPE, SEE SCHEDULE ON A4.00 <br />WINDOW TYPE, SEE SCHEDULE ON A4.00 <br />XX KEY NOTE PER SCHEDULE <br />FLOOR DEPRESSION <br />XX <br />LEGEND <br />WALL TYPE, SEE SCHEDULE ON A4.00NWX <br />KITCHEN EXHAUST FAN MIN. 100 CFM SHALL BE DUCTED TO <br />OUTSIDE THROUGH ROOF/EXTERIOR WALL <br />2X4 WALL / INFILL WITH INSULATION PER T-24 <br />EXHAUST FAN SHALL BE ENERGY STAR RATED. CEILING <br />MOUNTED LIGHT w/ VENT 50 CFM MIN. INTERMITTENT W/ <br />HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50%-80% <br />SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR <br />WALL <br />RESIDENCE IAQ FAN: 80 CFM <br />SEE T24 FOR SELECTION <br />HB <br />3/4" HOSE BIBB WITH BACK-FLOW PREVENTOR <br />SMOKE DETECTOR HARDWIRED w/ BATTERY BACK UPSD <br />CARBON MONOXIDE DETECTOR ALARM HARDWIRED w/ <br />BATTERY BACK UPCD <br />ATTIC FURNACE <br />AC CONDENSER UNIT ON PAD 3" MIN. <br />50 GAL HEATPUMP INDOOR WATER <br />HEATER <br />2X4 1-HOUR FIRE RATED WALL <br />LAUNDRY DRYER EXHAUST <br />ELECTRICAL PANEL/METER PER KEYNOTE <br />CEILING AIR DIFFUSER <br />GARBAGE DISPOSAL <br />9FT CEILING HEIGHT PER STRUCTURE <br />VAULTED CEILING PER STRUCTURE <br />R327.1.1 REINFORCEMENT FOR GRAB BARS: <br />AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH <br />REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. WHERE THERE IS NO <br />BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD <br />FLOOR OF THE DWELLING SHALL COMPLY WITH THIS SECTION. <br />1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS <br />APPROVED BY TH REINFORCING AGENCY. <br />2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH (51 MM BY 203 MM) <br />NOMINAL LUMBER. [11/2 INCH BY 71/4 INCH (38 MM BY 184 MM) ACTUAL <br />DIMENTION] OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND <br />LOAD CAPACITY. REINFORMENT SHALL BE LOCATED BETWEEN 32 INCHES (812.8 MM) <br />AND 39 1/4 INCHES (997 MM) ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL <br />FRAMING. <br />3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE <br />FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. <br />4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS <br />PROVIDED. <br />5. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE <br />CONTTINUOS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, <br />BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE <br />BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES (152.4 MM) ABOVE THE BATHTUB <br />RIM. <br />EXCEPTIONS: <br />1. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL <br />CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE <br />PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY OR <br />SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE <br />ENFORCING AGENCY. <br />2. REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR <br />PREFABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS <br />WITH INTEGRAL FACTORY-INSTALLED GRAB BARS OR WHEN FACTORY- <br />INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. <br />3. SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF <br />REINFORCEMENT AND /OR GRAB BARS SHALL BE PERMITTED, PROVIDED <br />REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR <br />AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />4. BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO <br />NOT PERMIT THE INSTALLATION OF REINFORCEMENT SHALL BE <br />PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR - <br />MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE <br />METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />5. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS <br />AND WATER CLOSETS INSTALLED ON CONCRETE SLAB FLOORS. <br />R327.1.2 ELECTRICAL RECEPTACLE OUTLET, <br />SWITCH AND CONTROL HEIGHTS: <br />ELECTRICAL RECEPTACLE OUTLETS, SWITCHES <br />AND CONTROLS (INCLUDING CONTROLS FOR <br />HEATING, VENTILATION AND AIR CONDITIONING) <br />INTENDED TO BE USED BY OCCUPANTS SHALL BE <br />LOCATED NO MORE THAN 48 INCHES (1219.2 MM) <br />MEASURED FROM THE TOP OF THE OUTLET BOX <br />AND NOT LESS THAN 15 INCHES (381 MM) <br />MEASURED FROM THE BOTTOM OF THE OUTLET <br />BOX ABOVE THE FINISH FLOOR. <br />EXCEPTIONS: <br />1. DEDICATED RECEPTACLE OUTLETS; FLOOR <br />RECEPTACLE OUTLETS; CONTROLS MOUNTED <br />ON CEILING FANS AND CEILING LIGHTS; AND <br />CONTROLS LOCATED ON APPLIANCES. <br />2. RECEPTACLE OUTLETS REQUIRED BY THE <br />CALIFORNIA ELECTRICAL CODE ON A WALL <br />SPACE WHERE THE DISTANCE BETWEEN THE <br />FINISHEDFLOOR AND A BUILT-IN FEATURE <br />ABOVE THE FINISH FLOOR , SUCH AS A <br />WINDOW, IS LESS THAN 15 INCHES (381 MM) <br />R327.1.3 INTERIOR DOORS <br />EFFECTIVE JULY 1, 2024, AT LEAST ONE BATHROOM AND ONE <br />BEDROOM ON THE ENTRY LEVEL SHALL PROVIDE A <br />DOORWAY WITH A NET CLEAR OPENING OF NOT LESS THAN <br />32 INCHES (812.8 MM), MEASURED WITH THE DOOR <br />POSITIONED AT AN ANGLE OF 90 DEGREES FROM THE <br />CLOSED POSITION; OR, IN THE CASE OF A TWOOR THREE- <br />STORY SINGLE FAMILY DWELLING, ON THE SECOND OR <br />THIRD FLOOR OF THE DWELLING IF A BATHROOM OR <br />BEDROOM IS NOT LOCATED ON THE ENTRY LEVEL. <br />R327.1.4 DOORBELL BUTTONS: <br />DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED <br />SHALL NOT EXCEED 48 INCHES (1219.2 MM) ABOVE <br />EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP <br />OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL <br />BUTTONS INTEGRATED WITH OTHER FEATURES ARE <br />REQUIRED TO BE INSTALLED ABOVE 48 INCHES (1219.2 MM) <br />MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A <br />STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE <br />PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES (1219.2 <br />MM) ABOVE EXTERIOR FLOOR OR LADING, MEASURED FROM <br />THE TOP OF THE DOORBELL BUTTON OR CONTROL. <br />1. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED <br />DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH <br />SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR <br />SNOW. VENTILATION OPENINGS SHALL HAVE AT LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. <br />VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE PROVIDED <br />W/. CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, OR SIMILAR <br />MATERIAL WITH OPENINGS HAVING A LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. OPENINGS IN <br />ROOF FRAMING MEMBERS SHALL CONFORM TO THE REQ'TS. OF CRC R802.7. REQUIRED <br />VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR. <br />2. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE <br />SPACE VENTILATED. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/300 IF ONE <br />OR MORE OF THE FOLLOWING ARE MET; 1. IN CLIMATE ZONES 14 & 16, A CLASS I OR II VAPOR <br />RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. 2. AT LEAST 40% <br />AND MORE THAN 50% OF THE REQUIRED VENTILATING ARE IS PROVIDED BY VENTILATORS <br />LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS <br />SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE <br />SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF TEH REQUIRED VANTILATION <br />PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING <br />MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE <br />THAN 3 FEET BELOW THE RIDGE OR HIGHEST OF THE SPACE SHALL BE PERMITTED. <br />3. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE <br />FLOW OF AIR. A MIN. OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE <br />ROOF SHT'G. AND AT THE LOCATION OF THE VENT. <br />4. VENTILATORS SHALL BE INSTALLED IN ACCORDANCE WITH MFR'G.'S INSTALLATION <br />INSTRUCTIONS. INSTALLATION OF VENTILATORS IN ROOF SYSTEMS SHALL BE IN ACCORDANCE <br />W/. THE REQ'TS. OF SECTION R903. INSTALLATION OF VENTILATORS IN WALL SYSTEMS SHALL <br />BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R703.1. <br />5. UNVENTED ATTIC ASSEMBLIES (SPACES BETWEEN THE CEILING JOISTS OF THE TOP STORY <br />AND THE ROOF RAFTERS) AND UNVENTED ENCLOSED RAFTER ASSEMBLIES (SPACES <br />BETWEEN CEILINGS THAT ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING <br />MEMBER/RAFTERS AND THE STRUCTURAL ROOF SHT'G. AT THE TOP OF THE ROOF FRAMING <br />MEMBERS/RAFTERS) SHALL BE PERMITTED IF ALL OF THE FOLLOWING CONDITIONS ARE MET: <br />1. THE UNVENTED ATTIC SPACE IS COMPLETELY CONTAINED WITHIN THE BUILDING THERMAL <br />ENVELOPE. <br />2. NO INTERIOR CLASS I VAPOR RETARDERS ARE INSTALLED ON THE CEILING SIDE (ATTIC <br />FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED <br />ENCLOSED RAFTER ASEEMBLY. <br />3. WHERE WOOD SHINGLES OF SHAKES ARE USED, A MIN. 1/4" VENTED AIR SPACE SEPARATES <br />THE SHINGLES OR SHAKES AND THE ROOFING UNDERLAYMENT ABOVE THE STRUCTURAL SHT'G. <br />4. IN CALIFORNIA CLIMATE ZONES 14 & 16, ANY AIR-IMPERMEABLE INSULATION SHALL BE A <br />CLASS II VAPOR RETARDER, OR SHALL HAVE A CLASS III VAPOR RETARDER COATING OR <br />COVERING IN DIRECT CONTACT W/. THE UNDERSIDE OF THE INSULATION (SEE TITLE 24, PART 6, <br />FIG. 100.1-A) <br />5. EITHER ITEMS 5.1, 5.2 OR 5.3 SHALL BE MET, DEPENDING ON THE AIR PERMEABILITY OF THE <br />INSULATION DIRECTLY UNDER THE STRUCTURAL ROOF SHT'G. (NO INSULATION SHALL BE <br />REQ'D. WHEN ROOF TILES, WOOD SHINGLES OR WOOD SHAKES, OR ANY OTHER ROOFING <br />SYSTEM USING BATTENS AND NO CONT. UNDERLAYMENT IS INSTALLED. A CONT. LAYER SHALL <br />BE CONSIDERED TO EXIST IF SHT'G., ROOFING PAPER OR ANY CONT. LAYER WHICH HAS A PERM <br />RATE OF NO MORE THAN ONE PERM UNDER THE DRY CUP METHOD.); <br />5.1. AIR-IMPERMEABLE INSULATION ONLY. INSULATION SHALL BE APPLIED IN DIRECT <br />CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. <br />5.2. AIR-PERMEABLE INSULATION ONLY. IN ADDITION TO THE AIR-PERMEABLE INSULATION <br />INSTALLED DIRECTLY BELOW THE STRUCTURAL SHT'G., RIDGE BOARD OR SHEET <br />INSULATION W/. AN R-VALUE OR R-4 SHALL BE INSTALLED DIRECTLY ABOVE THE <br />STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. <br />5.3. AIR-IMPERMEABLE AND AIR-PERMEABLE INSULATION. THE AIR-IMPERMEABLE <br />INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE <br />STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. THE AIR-PERMEABLE <br />INSULATION SHALL BE INSTALLED DIRECTLY UNDER TH AIR-PERMEABLE INSULATION. <br />5.4. WHERE PREFORMED INSULATION BOARD IS USED AS THE AIR0IMPERMEABLE <br />INSULATION LAYER, IT SHALL BE SEALED AT THE PERIMETER OF EACH INDIVIDUAL SHEET <br />INTERIOR SURFACE TO FORM A CONT. LAYER. <br />1. (N) ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY CERTAINTEED ICC-ESR# 3537 <br />OR EQUAL. THE INSTALLATION OF ROOF COVERING SHALL BE IN ACCORDANCE WITH <br />MANUFACTURER'S SPECIFICATIONS. <br />2. PROJECTIONS LESS THAN 3'-0" (HOUSE WITH SPRINKLER) OR 5'-0" (HOUSE WITH NO <br />SPRINKLER) TO PROPERTY LINE TO BE 1-HOUR CONSTRUCTION, TYP. <br />3. PROVIDE MIN. 2% SLOPE AT FLAT ROOF AND DECK (IF OCCUR). <br />4. BOTH ADU AND PRIMARY DWELLING ROOF MUST MATCH AND BE SUBSTANTIALLY SIMILAR IN <br />DESIGN, PITCH, COLOR, MATERIAL AND TEXTURE. <br />5. INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURER’S <br />SPECIFICATIONS. <br />(N) DETACHED ADU ATTIC AREA: 694 SF <br />NET VENT AREA REQUIRE: 694/150 x 144SQ.IN = 666 SQ.IN <br />USE 10 O'HAGIN 72 SQ. IN/UNIT, SEE SPEC. <br />5 <br />01-A-201 <br />5 <br />01-A-201 <br />01 <br />-A-20 <br />1 <br />4 <br />01-A-201 <br />2 <br />01-A-201 <br />1 <br />01 <br />-A-20 <br />1 <br />3 <br />6 <br />01-A-201 <br />6 <br />01-A-201 <br />(N <br />) <br /> <br />C <br />A <br />B <br />I <br />N <br />E <br />T <br />(N)ADU -KITCHEN <br />VAULTED CEILING <br />WOOD <br />(N)ADU -LIVING AREA <br />VAULTED CEILING <br />WOOD <br />(N)ADU -BEDROOM #2 <br />VAULTED CEILING <br />WOOD <br />(N)ADU -BATH #2 <br />9'-0" CL'G <br />TILE <br />PA <br />N <br />T <br />R <br />Y <br />(N)ADU -BATH #1 <br />9'-0" CL'G <br />TILE <br />(N)ADU -CLOSET <br />(N)ADU -BEDROOM #1 <br />VAULTED CEILING <br />WOOD <br />EE&RO <br />EE <br />& <br />R <br />O <br />MIN. 10FT FOR PHOTO-ELECTRIC SD <br />12'-9" <br />CL <br />O <br />S <br />E <br />T <br />(N <br />) <br /> <br />C <br />A <br />B <br />I <br />N <br />E <br />T <br />(N) PAVING CONCRETE AREA <br />FAU <br />(N)ADU -HALLWAY <br />9'-0" CL'G <br />WOOD <br />1. <br />5 <br />' <br />' <br />1.5" <br />SD <br />CDSD <br />SD <br />5. <br />2 <br />5 <br />' <br />' <br />5.25'' <br />30 <br />51 <br />(N <br />) <br /> <br />C <br />A <br />B <br />I <br />N <br />E <br />T <br />50 <br />MIN. <br />3'-0" <br />N-A <br />N-A <br />N-2 <br />N-B <br />N-1 <br />N-3 <br />N-8 <br />N-9 <br />N-6 <br />N-6 <br />N-9 <br />N-6 <br />N-5 <br />N-7 <br />N-C <br />N-C <br />N-3 <br />N-DN-D <br />N-10 <br />N-5 <br />3'-0"5'-11 1/2"2'-0" <br />2' <br />- <br />8 <br />" <br />5' <br />- <br />4 <br />" <br />2' <br />- <br />0 <br />" <br />52 <br />16.1 <br />33 <br />27'-0" <br />38 <br />' <br />- <br />6 <br />" <br />4' <br />- <br />1 <br />0 <br />" <br />10 <br />' <br />- <br />8 <br />" <br />23 <br />' <br />- <br />0 <br />" <br />11'-9 1/2"2'-10"2'-9"9'-7 1/2" <br />6'-3"5'-6 1/2" 1'-5''1'-5"5'-11 1/2"3'-8" <br />2'-0"9'-2" <br />3' <br />- <br />0 <br />" <br />6' <br />- <br />7 <br /> <br />1 <br />/ <br />2 <br />" <br />59 <br />75 <br />55 <br />38 <br />' <br />- <br />6 <br />" <br />4' <br />- <br />1 <br />0 <br />" <br />10 <br />' <br />- <br />1 <br />" <br />2' <br />- <br />9 <br />" <br />5' <br />- <br />0 <br />" <br />5' <br />- <br />9 <br />" <br />10 <br />' <br />- <br />1 <br />" <br />2' <br />- <br />1 <br />0 <br /> <br />1 <br />/ <br />2 <br />" <br />2' <br />- <br />1 <br />0 <br /> <br />1 <br />/ <br />2 <br />" <br />4' <br />- <br />1 <br />0 <br />" <br />5' <br />- <br />3 <br /> <br />1 <br />/ <br />2 <br />" <br />2' <br />- <br />6 <br />" <br />2' <br />- <br />6 <br />" <br />5' <br />- <br />3 <br /> <br />1 <br />/ <br />2 <br />" <br />4' <br />- <br />1 <br />0 <br />" <br />27'-0" <br />15'-0"12'-0" <br />2' <br />- <br />2 <br /> <br />1 <br />/ <br />2 <br />" <br />7' <br />- <br />8 <br /> <br />1 <br />/ <br />2 <br />" <br />13 <br />' <br />- <br />1 <br />" <br />6'-6"8'-6 1/2" <br />6'-0"6'-0" <br />3'-0" <br />4' <br />- <br />2 <br />" <br />12'-0 1/2" <br />12 <br />' <br />- <br />1 <br />" <br />2'-10" <br />3' <br />- <br />0 <br />" <br />54 <br />55 <br />59 <br />60 <br />16.1 <br />16.1 <br />1. <br />5 <br />" <br />5' <br />- <br />0 <br />" <br />5' <br />- <br />0 <br />" <br />8'-9 1/2" <br />8'-1"3'-0" <br />9' <br />- <br />7 <br /> <br />1 <br />/ <br />2 <br />" <br />2' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />4'-6" <br />7' <br />- <br />1 <br />" <br />1' <br />- <br />1 <br />0 <br />" <br />11'-1" <br />1.5 <br />1.4 <br />1.2 <br />1.1 <br />76 <br />76 <br />5' <br />- <br />4 <br />" <br />5' <br />- <br />4 <br />" <br />3' <br />- <br />2 <br />" <br />TYPICAL <br />O'HAGIN VENTILATION <br />TYPICAL <br />(N) SKYLIGHT EVALUATION <br />REPORT NUMBER 199 OR EQUAL <br />(N) ROOF MATERIAL COVERING CLASS "A" <br />ASPHALT SHINGLES BY CERTAINTEED ICC <br />ESR# 3537 OR EQUAL. OVER PLYWOOD <br />SHEATING OVER RADIANT BARRIER OVER <br />RAFTERS PWE STRUCTURAL DWGS. ROOF <br />COLOR AND MATERIAL TO MATCH WITH <br />EXISTING BUILDING, EQUAL. <br />5 <br />01-A-201 <br />5 <br />01-A-201 <br />WALL LINE BELOW <br />WALL LINE BELOW <br />WA <br />L <br />L <br /> <br />L <br />I <br />N <br />E <br /> <br />B <br />E <br />L <br />O <br />W <br />WA <br />L <br />L <br /> <br />L <br />I <br />N <br />E <br /> <br />B <br />E <br />L <br />O <br />W <br />01 <br />-A-20 <br />1 <br />4 <br />01-A-201 <br />2 <br />01-A-201 <br />1 <br />01 <br />-A-20 <br />1 <br />3 <br />6 <br />01-A-201 <br />6 <br />01-A-201 <br />TYPICAL <br />(N) SKYLIGHT EVALUATION <br />REPORT NUMBER 199 OR EQUAL <br />WA <br />L <br />L <br /> <br />L <br />I <br />N <br />E <br /> <br />B <br />E <br />L <br />O <br />W <br />SOLAR AREA DESIGN BY OTHER <br />LAUNDRY VENT EXHAUST <br />THROUGH ROOF <br />N-E N-E <br />N-E <br />4: <br />1 <br />2 <br />4: <br />1 <br />2 <br />4:12 <br />4:12 <br />36TYP. <br />38 TYP. <br />1' <br />- <br />6 <br />" <br />1'-6" <br />1' <br />- <br />6 <br />" <br />1'-6" <br />1' <br />- <br />6 <br />" <br />4:12 <br />1'-6" <br />1'-6" <br />4'-4 1/2" <br />RES-2025-1703-SCND <br />JUL 05, 2025 <br />©2025Sheet No. <br />Rev. <br />Application No: <br />Date <br />Design by <br />TRINH HA <br />Date Rev. <br />Pr <br />o <br />j <br />e <br />c <br />t <br />: <br />1 12-17-2025 BLDG comments <br />01-A-200 <br />PO <br />I <br />N <br />S <br />E <br />T <br />T <br />I <br />A <br /> <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />MA <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br /> <br />2 <br />1 <br />0 <br />9 <br /> <br />N <br /> <br />P <br />o <br />i <br />n <br />s <br />e <br />t <br />t <br />i <br />a <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />DE <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br /> <br />2 <br />1 <br />1 <br />1 <br /> <br />N <br /> <br />P <br />o <br />i <br />n <br />s <br />e <br />t <br />t <br />i <br />a <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />na <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />DETACHED ADU - <br />1ST FLOOR PLAN & <br />ROOF PLAN <br />1.1 RELOCATED (E) ELECTRICAL METER FOR MAIN HOUSE, 200 AMP, WITH 225 AMP BUS-RATING <br />1.2 (N) ELECTRICAL METER FOR DETACHED ADU, 200 AMP, WITH 225 AMP BUS-RATING <br />1.4 (N) ELECTRICAL SUB PANEL DETACHED ADU, 200 AMP. WITH 225 AMP BUS-RATING <br />1.5 (N) 60AMP SUBPANEL FOR ADU ESS SYSTEM <br />16.1 (N) LANDING. 1 1/2" BELOW THRESHOLD.MINIMUM 36" IN DEPTH. MIN. 2% SLOPE AWAY FROM <br />BUILDING. <br />30 (N) AC UNIT ON 3" THIK. CONCRETE PAD PER T-24. (SHALL BE VERIFIED AND APPROVED BY THE <br />BUILDING INSPECTOR PRIOR TO INSTALLATION) <br />33 (N) HEAT PUMP WATER HEATERS PER T-24 <br />36 O'HAGIN ROOF VENT <br />38 (N) SKYLIGHT EVALUATION REPORT NUMBER 199 <br />50 (N) 22"X30" ATTIC ACCESS <br />51 <br />(N) 30" INDUCTION RANGE WITH OVEN. PROVIDE EXHAUST HOOD WITH LIGHT AND FAN VENT TO <br />OUTSIDE AIR (280 CFM) WITH 8" DUCT. VERIFY DIMENSIONS AND POWER REQUIREMENTS WITH <br />MANUFACTURER'S SPECIFICATIONS. <br />52 THIS SWITCH CONTROLS THE INDOOR AIR QUALITY VENTILATION FOR THE HOME. LEAVE SWITCH IN <br />THE 'ON' POSITION AT ALL TIMES UNLESS THE OUTDOOR AIR QUALITY IS VERYPOOR."[150.0(O)J] <br />54 <br />MIN. 4" DIA. TO THE OUTSIDE, EQUIPPED WITH A BACK DRAFT DAMPER. DUCT LENGTH OR SIZES AS <br />PERMITTED OR REQUIRED BY MANUFACTURERS INSTALLATIONS AND APPROVED BY THE BUILDING <br />OFFICIAL (EXHAUST THROUGH ROOF) SEE DETAIL ON SHEET AD.1 <br />55 <br />EXHAUST FAN FOR BATHROOM SHALL BE ENERGY STAR RATED. CEILING MOUNTED LIGHT W/ VENT <br />50CFM MIN. INTERMITTENT W/HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50-80% SHALL BE <br />DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL <br />59 32" MIN. CLEARANCE INTERIOR DOOR <br />60 FUTURE INSTALLED FLOOR MOUNTED FOLDABLE GRAB BAR <br />75 TEMPERED GLASS <br />76 TEMPERED, OBSCURED GLASS <br />FLOOR PLAN NOTESAGING-IN PLACE NOTES:FLOOR PLAN LEGENDS <br />FLOOR PLAN KEYNOTES <br />ROOF PLAN GENERAL NOTES <br />VENTILATION NOTES <br />ATTIC & RAFTER CAVITY VENTILATION <br />1/4" = 1'-0"1DETACHED ADU - 1ST FLOOR PLAN1/4" = 1'-0"2DETACHED ADU - ROOF PLAN