ACCESS PANEL -PUSH UP <br />INSULATION <br />DOUBLE 2X PER FRAMING <br />PLAN. SEE A3.02 FOR REF. <br />GYPSUM BOARD <br />TRIM <br />AIR-SEAL GASKET <br />6x CEILING JOIST <br />@ 16" O.C. MAX. <br />WALL PER WALL TYPES, <br />TYP. <br />5/8" GYP. BD. CEILING <br />SIMPSON U26 EA. <br />SIDE, TYP. <br />2X LEDGE W/ 3-16D NAILS @ EACH <br />STUD W/ 3-16 D NAIL @ EACH BLKG. <br />2X BLKG. <br />2X4 @ 16" O.C. STUD <br />WIRE MESH <br />6-MIL POLY OR 15LB. FELT, <br />LAP OVER MEMBRANE <br />TILE OVER LATEX-MODIFIED THINSET <br />(N) 4" SHOWER DRAIN, <br />2-PIECE CLAMPING <br />SOLID BLOCKING BETWEEN STUDS <br />EXTEND MEMBRANE 3" ABOVE CURB <br />MORTAR BED OR CEMENT <br />BACKER BOARD <br />2X WALL <br />MORTAR BED <br />40-MIL CPE SHOWER <br />PAN MEMBRANE <br />CRUSHED TILE AROUND <br />WEEP HOLES <br />LATEX-MODIFIED MORTAR <br />SLOPED 1/4" PER FT. <br />15 LB. FELT AND WIRE LATH <br />WOOD FLOOR SUB-BASE, <br />SEE STRUCT. FOR REF. <br />CURB <br />SEALANT WITH BACKER ROD. <br />ALUMINUM TRACK TO BE <br />INSTALLED PER MANF. SPECS. <br />BATHROOM GLASS ENCLOSURE. SEE <br />ENLARGE PLAN FOR SAFETY GLAZING <br />INFORMATION. <br />2 <br />1 <br />3 3 <br />4 <br />5 <br />6 <br />1. 1/2" SISALKRAFT FLASHING <br /> OR EQUIVALENT <br />2. INSTALL SILL FLASHING <br /> FASTEN TOP EDGE ONLY <br />3. INSTALL SIDE FLASHING <br /> LAP OVER SILL FLASHING <br />4. INSTALL FRAME WITH NAILING <br /> FLANGE ON CONT. SEALANT BED <br />5. INSTALL HEAD FLASHING ON <br /> CONT. SEALANT BED OVER <br /> NAILING FLANGE <br />6. INSTALL BUILDING FELT UNDER <br /> SILL FLASHING AND OVER <br /> SIDE AND HEAD FLASHING <br />BEST PRACTICES FOR FUTURE PHOTOVOLTAIC SYSTEM INSTALLATION <br />ELEC. SERVICE PANEL SHALL HAVE <br />RESERVED SPACES TO ALLOW FOR <br />THE INSTALLATION OF DOUBLE <br />POLE CIRCUIT BREAKERS FOR THE <br />FUTURE INSTALLATION OF: <br />1.SOLAR ELECTRIC. (CEnC 110.10 (b)B 4(e)) <br />2.ENERGY STORAGE <br />SYSTEM (CEnC 150.0(s)) <br />3.HEAT PUMP SPACE HEATER(CEnC 150.0(t)) <br />4.ELECT. COOKTOP (CEnC 150.0(u)) <br />5.ELECT. CLOTHES DRYER (CEnC 150.0(v)) <br />RESERVE 36"X36" AREA <br />FOR INVERTER, METER <br />AND DISCONNECT <br />3/4" NON-FLEXIBLE METAL <br />CONDUIT (MIN.) WITH PULL <br />STRING TERMINATED IN 4" <br />SQUARE BOX FOR DC <br />CONDUCTORS APPROX. 36" <br />OFF THE FINISHED FLOOR <br />AND LABELED "RESERVED <br />FOR SOLAR" <br />ELECTRIC PANEL <br />MAIN <br />FINISHED FLOOR <br /> <br />3 <br />6 <br /> <br />" <br /> <br />3 <br />6 <br /> <br />" <br /> 36" <br />SEE FLOOR PLAN <br />0' <br /> <br />- <br /> <br />3 <br />" <br /> <br />T <br />Y <br />P <br />. <br />1'-0" TYP.EQ <br />EQ <br />0' <br /> <br />- <br /> <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />CONCRETE HOUSEKEEPING PAD <br />CHAMFER ALL OUTSIDE CORNERS <br />CONSTRUCTION NOTES: <br />1. PAD DIMENSIONS AND ANCHOR BOLT SIZES TO SUIT EQUIPMENT. <br />REFERENCE EQUIPMENT MANUFACTURER SPECS FOR INSTALLATION <br />REQUIREMENTS. <br />DESIGN NOTES: <br />1. CONSULT WITH EQUIPMENT CUTSHEET TO DETERMINE IF A THICKENED <br />FLOOR SLAB UNDER BASED IS REQUIRED. <br />2. SLAB SURFACE PREPARATION FOR PAD DETERMINED BY WHETHER NEW <br />OR EXISTING. <br />SLAB SURFACE SHALL BE ROUGHENED IN <br />PREPARATION FOR CONCRETE PAD. <br />W.W.F. 6X6 -W4XW4 <br />#4 @12" O.C. ALONG <br />PERIMETER OF PAD <br />AL <br />L <br /> <br />A <br />R <br />O <br />U <br />N <br />D <br />0' <br /> <br />- <br /> <br />1 <br />" <br /> <br />C <br />L <br />E <br />A <br />R <br />(E) FINISH FLOOR0' <br /> <br />- <br /> <br />0 <br /> <br />1 <br />/ <br />2 <br />" <br />0' - 0 1/2" <br />EPOXY DOWEL INTO <br />CONC. SLAB <br />4" MIN. <br />EXTEND EDGE OF PAD <br />4" MIN. BEYOND <br />EQUIP. FRAME, TYP. <br />TOP <br />LANDING <br />BOTTOM <br />LANDING <br />NOTE: <br />FOR TREAD AND RISER DIMENSION REFER TO PLANS AND SECTIONS. <br />STAIRS, REISER AND LANDINGS SHALL BE COORDIANTED BY CONTRACTOR. <br />TW = TREAD WIDTH <br />1-1/4 MAX <br />TW <br />12" MIN <br />12" MIN <br />TW + 1236 <br />" <br /> <br />T <br />Y <br />P <br />TO <br /> <br />F <br />F <br />36 <br />" <br /> <br />T <br />Y <br />P <br />. <br />TOP & BOTTOM TYP <br />1-1/2" OD HANDRAIL <br />WITH RADIUSED RETURNS <br />TO WALL EA END. HANDRAIL <br />MATERIAL TBD. <br />A502 <br />C3 <br />NOTE: <br />THE BOTTOM OF HANDRAIL GRIPPING SURFACES SHALL NOT BE OBSTRUCTED <br />FOR MORE THAN 20% OF THEIR LENGTH. <br />FINISH WALL <br />1-1/2" ∅HANDRAIL <br />1/ <br />8 <br />" <br /> <br />C <br />L <br />E <br />A <br />R <br />1 1/2" <br />1 1/2" MIN <br />1 1/2" <br />1 1/2" MIN <br /> <br /> <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />U. <br />N <br />. <br />O <br />. <br />36 <br />" <br /> <br />M <br />I <br />N <br />. <br />U. <br />N <br />. <br />O <br />. <br />36 <br />" <br /> <br />M <br />I <br />N <br />. <br />WASHER DRYER <br />12 <br />" <br /> <br />M <br />I <br />N <br />. <br />VERTICAL (VER.) VENT <br />BACK DRAFT DAMPER (BDD). <br />SEE FLOOR PLAN FOR VENT <br />DIRECTION / ORIENTATION. <br />HORIZONTAL (HRZ.) VENT <br />DIRECT TO EXTERIOR (14 <br />FEET MAX). SEE FLOOR PLAN <br />FOR VENT DIRECTION / <br />ORIENTATION. <br />VE <br />R <br />. <br /> <br />V <br />E <br />N <br />T <br />HRZ. VENT <br />DRYER VENT INLET <br />GFI QUAD OUTLET <br />HOT & COLD WATER <br />SUPPLY <br />DRAIN <br />GAS POINT OF <br />CONNECTION <br />18 <br />" <br /> <br />T <br />Y <br />P <br />. <br />CLOTHES DRYERS -DOMESTIC MOISTURE EXHAUST DUCTS PER CMC SECTION 504 <br />• DUCT SHALL TERMINATE ON THE OUTSIDE OF BUILDING AND BE EQUIPPED WITH <br />BACK-DRAFT DAMPER. <br />• NO SCREENS SHALL BE INSTALLED AT DUCT TERMINATION <br />• DUCT SHALL NOT BE CONNECTED BY SHEET METAL SCREWS OR OTHER <br />OBSTRUCTIVE FASTENERS. <br />• DUCT SHALL NOT BE CONNECTED TO GAS VENT CONNECTOR, GAS VENT, OR <br />CHIMNEY AND SHALL ONLY SERVE CLOTHS DRYERS. <br />• DUCTS UNDER POSITIVE PRESSURE SHALL NOT EXTEND INTO OR THROUGH DUCT OR <br />PLENUMS. <br />• A FLEXIBLE DUCT CANNOT EXTEND MORE THAN 6 FT AND CANNOT BE CONCEALED. <br />• VENTS SHALL BE INSTALLED TO EXTEND AT MIN. 12" ABOVE FINISHED ROOF <br />SURFACE. <br />• <br />DOMESTIC CLOTHES DRYERS <br />WHEN A COMPARTMENT OR SPACE FOR DOMESTIC TYPE 1 CLOTHS DRYER IS PROVIDED, <br />THE FOLLOWING RESTRICTIONS APPLY: <br />• MINIMUM 4-INCH DIAMETER MOISTURE EXHAUST DUCT APPROVED MATERIAL SHALL <br />BE INSTALLED. <br />• DUCTS SHALL BE INSULATED THROUGH ATTIC ND CRAWL SPACE WITH 1 3/4" POUND <br />FIBERGLASS DUCT WRAP. <br />• DOMESTIC CLOTHES DRYER VENTS SHALL BE MADE OF METAL AND HAVE SMOOTH <br />INTERIOR SURFACE. <br />• TRANSITION DUCTS USE TO CONNECT THE DRYER TO THE EXHAUST DUCT SHALL BE <br />LISTED AND LABELED IN ACCORDANCE WITH UL 2158A. <br />LENGTH LIMITATION <br />• UNLESS OTHERWISE PERMITTED OR REQUIRED BY THE DRYER MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS, AND APPROVED BY THE BUILDING OFFICIAL, DOMESTIC <br />DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED <br />HORIZONTAL AND VERTICAL LENGTH OF 14 FT, INCLUDING TWO 90-DEGREE ELBOWS. <br />• TWO FEET SHALL BE DEDUCTED FOR EACH 90-DEGREE ELBOW IN EXCESS OF TWO. <br />EXCEPTION: WHERE AN EXHAUST DUCT POWER VENTILATOR, IN ACCORDANCE WITH <br />SECTION 504.4.2.3, I USED, THE MAXIMUM LENGTH OF THE DRYER EXHAUST DUCT SHALL BE <br />PERMITTED TO BE IN ACCORDANCE WITH THE DRYER EXHAUST DUCT POWER VENTILATOR <br />MANUFACTURER'S INSTALLATIONS INSTRUCTIONS. <br />EXHAUST DUCT POWER VENTILATORS <br />• DRYER EXHAUST DUCT POWER VENTILATORS FOR SINGLE RESIDENTIAL CLOTHES <br />DRYERS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 705 AND <br />INSTALLED IN ACCORDANCE WITH THE MANUFACTURE'S INSTALLATION <br />INSTRUCTIONS. <br />TERMINATION OF ENVIRONMENTAL AIR DUCTS <br />• DUCT SHALL TERMINATE A MINIMUM OF 3 FT FROM PROPERTY LINE AND 3 FT FROM <br />OPENINGS INTO THE BUILDING. <br />PROVISIONS FOR MAKEUP AIR <br />• WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN <br />OPENING OF NO LESS THAN 100 SQUARE INCHES FOR MAKEUP AIR SHALL BE <br />PROVIDED IN THE DOOR OR BY OTHER APPROVED MEANS. <br />INTERIOR ELEVATION <br />ISSUED <br />DATE: <br />REVISIONS <br />DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS <br />INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE <br />DRAFTER/DESIGNER WHETHER THE PROJECT FOR <br />WHICH THEY ARE MADE BE EXECUTED OR NOT, AND <br />THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN <br />THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY <br />AGREEMENT IN WRITING. <br />NO <br />. <br /> <br />D <br />E <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br /> <br />D <br />A <br />T <br />E <br />DRAFTER/DESIGNER: <br />LUIS N OROZCO <br />562.661.9281 <br />LUIS.OROZCO.A@LIVE.COM <br />DATE: <br />A502 <br />DETAILS - CONSTRUCTION <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />O <br />W <br />N <br />E <br />R <br />: <br /> <br />S <br />I <br />L <br />V <br />I <br />A <br /> <br />T <br />O <br />R <br />R <br />E <br />S <br />15 <br />1 <br />1 <br /> <br />S <br />. <br /> <br />B <br />I <br />R <br />C <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />0 <br />7 <br />2 <br />7 <br />GA <br />R <br />A <br />G <br />E <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />A <br />N <br />AC <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />U <br />N <br />I <br />T <br />09/10/2024 <br />Scale:3" = 1'-0"A2 INT - ATTIC ACCESS PANEL <br />Scale:1 1/2" = 1'-0"A3 <br />INT - WOOD FRAME TYPICAL <br />CEILING <br />Scale:3" = 1'-0"B1 INT - SHOWER PAN - WOOD FLOORS <br />Scale:3" = 1'-0"B3 WD - PERIMETER FLASHING <br />Scale:3" = 1'-0"B2 EXT - ELEC. SVC PANEL- FUTURE PV <br />Scale:3" = 1'-0"C1 EXT - HVAC HOUSEKEEPING PAD <br />Scale:1/4" = 1'-0"C2 INT - STAIR RAILING <br />Scale:1 1/2" = 1'-0"C3 INT - RAILING REQUIREMENT <br />Scale:3" = 1'-0"D1 INT - DOMESTIC CLOTHES DRYER <br />NOT USED <br />NOT USED