My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HOLD - 1511 & 1513 S Birch St - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Birch St
>
1511 S Birch St
>
HOLD - 1511 & 1513 S Birch St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2026 5:00:16 AM
Creation date
3/4/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
102122346
102122347
Full Address
1511 S Birch St
1513 S Birch St
Street Number
1513
Street Direction
S
Street Name
Birch
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
GYPSUM BOARD <br />DOOR AS SCHEDULED, SEE <br />FLOOR PLANS FOR DOOR <br />SWING <br />WALL PER WALL <br />TYPES. <br />WOOD FRAMING <br />HEADER, TYP. <br />5/ <br />8 <br />" <br />2" <br />22 GAGE GALV. SHEET <br />METAL DRIP EDGE <br />CONT. BACKER ROD <br />& SEALANT, TYP. <br />SELF-ADHERED FLEXIBLE <br />FLASHING, TYP. <br />2"2" <br />1/2" <br />7/8" EXTERIOR PLASTER <br />OVER METAL LATH OVER <br />(2) LAYERS OF GRADE D. <br />60 MIN. ASPHALTIC PAPER <br />CONT. PLASTER HEAD <br />FLASHING. PAINTED TO <br />MATCH EXTERIOR FINISH. <br />EXTERIOR DOOR PER SCHEDULE, SEE FLOOR <br />PLANS FOR DOOR SWING <br />FINISH FLOOR PER <br />OWNER <br />ALUMINUM THRESHOLD, SET <br />IN FULL BED OF MASTIC <br />LINE OF DOORSTOP BEYOND <br />LINE OF FRAME <br />BEYOND <br />2 <br />1 MAX. <br />ANCHOR @ 24" O.C. 6"@ <br />ENDS, 2" MIN. EMBEDMENT <br />EXTERIOR <br />CONCRETE <br />EL <br />E <br />V <br />. <br />SE <br />E <br /> <br />E <br />X <br />T <br />. <br />ALLOW PROPER AIR VENTILATION. <br />PROVIDE INSECT SCREEN WITH <br />STAGGERED PERFORATIONS. <br />PROVIDE 1" SPACE BETWEEN <br />INSULATION AND ROOF SHEETHING <br />WALL PER WALL TYPES. <br />15/32" WOOD STR. PANEL, REF. STRUC. <br />DRAWINGS <br />2X RAFTER PER STRUCTURAL <br />DRAWINGS <br />(2) 2X4 TOP PLATE <br />EDGE NAIL <br />UPLIFT FRAMING CLIP PER <br />TABLE R802.11 <br />1/2" CDX PLY SHEATHING W/8d @ <br />6"/6"/12" O.C. (COMMON NAILS) <br />REFERENCE STRUCTURAL DRAWINGS. <br />SIMPSON TIE PER STRUCTURAL <br />DRAWINGS <br />2X BLKG. <br />B.N. 8D @ 6" O.C. <br />2X FASCIA W/ 2# 10X 3" LONG <br />WOOD SCREWS @ EACH RAFTER <br />(8) 16D NAILS MIN. <br />FLASHING W/ <br />CAULKING <br />SELF-ADHERED <br />FLEXIBLE FLASHING <br />5/8" GYP. BD. <br />(2) LAYERS OF GRADE D <br />BLDG PAPER, TYP. EXT. <br />PLYWOOD SHEATHING. <br />GALV. SHEET METAL <br />WEEP SCREED - <br />PROVIDE MIN. 3 1/2" <br />ATTACHMENT FLANGE <br />2X P.T. SILL W/ 1/2" X 10" ANCHOR <br />BOLTS @ 6' O.C. & <br />0.229" X 3" X 3" PLATE WASHERS <br />EXT.FINISHED <br />GRADE. SLOPE <br />TO DRAIN. <br />7/8" EXTERIOR <br />PLASTER OVER <br />METAL LATH <br />PLASTER NOTE: <br />EXTERIOR PLASTER (STUCCO) WALL SHALL <br />BE PROVIDED WITH A CORROSION <br />RESISTANT WEEP SCREED COMPLYING <br />WITH SECTION R703.7.2.1 <br />TEXTURED <br />TERMINATION TAPE <br />UNDERSLAB VAPOR <br />BARRIER (10 MIL <br />VISQUEEN) <br />2" SAND OVER <br />6 MIL VISQUEEN CONT. URETHANE <br />SEALANT <br />SEALANT AND <br />BACKER ROD <br />BATT. INSULATION <br />GC TO PROVIDE MOISTURE <br />BARRIER COATING WHERE 6 MIL <br />VISQUEEN IS NOT ABLE TO BE <br />CONFIRMED. <br />GC. TO CONFIRM (E) CONC. CURB <br />WD. BASE BOARD <br />8" <br /> <br />M <br />I <br />N <br />. <br />24 <br />" <br /> <br />T <br />Y <br />P <br />12" MIN. <br />(2) -#4 BAR, TOP <br />(2) -#4 BAR, BOTTOM <br />3" <br /> <br />C <br />L <br />R <br />. <br />3-1/2" CONC. SLAB, #4 DEFORMED <br />REINF. @16" O.C. EA WAY <br />FOOTING NOTE: <br />GC TO FIELD VERIFIED EXISTING FOOTING <br />CONDITION FOR OVERALL COMPLIANCE, ADJUST <br />AS REQ. SEE STRUCTURAL DRAWINGS AND <br />DETAILS FOR FURTHER INFORMATION. <br />5/8" GYP BD. <br />WOOD HEADER, <br />PER STRUCTURAL <br />WINDOW FRAME. <br />CONT. SEALANT & <br />BACKER ROD, TYP. <br />SELF-ADHERED FLEXIBLE <br />FLASHING, TYP. <br />24 GA. SHEET METAL <br />DRIP, SET IN A CONT. <br />BED OF SEALANT. TYP. <br />GLAZING PER <br />WINDOW TYPES, TYP. <br />J-MOLD, <br />TYP. <br />V.I.F. <br />7/8" CEMENT PLASTER <br />OVER MTL LATH OVER (2) <br />LAYERS OF GRADE D <br />BLDG PAPER, TYP. <br />INT. WINDOW FASCIA TRIM <br />PER MFG. <br />1/2" TYP. <br />BATT INSULATION <br />NOTE: <br />1. CONTRACTOR SHALL VERIFY COMPATIBILITY BETWEEN MATERIALS PRIOR TO <br />INSTALLATION OF ANY WATERPROOFING OR WATER BARRIER MATERIALS. <br />2. SEE DETAIL NO.7 FOR TYPICAL WINDOW FLASHING. G.C. SHALL COORDINATE AS REQUIRED <br />CONT. BACKER ROD & <br />SEALANT <br />GYP. BD. <br />GALV. SHEET METAL WEEP <br />SCREED -PROVIDE MIN. 3 <br />1/2" ATTACHMENT FLANGE <br />2X P.T. SILL W/ ANCHOR BOLTS <br />AND PLATE WASHERS <br />2X RIM JOIST <br />CONC. STEM WALL <br />PLASTER NOTE: <br />EXTERIOR PLASTER (STUCCO) <br />WALL SHALL BE PROVIDED WITH A <br />CORROSION RESISTANT WEEP <br />SCREED COMPLYING WITH SECTION <br />R703.7.2.1 <br />FOOTING NOTE: <br />1. SEE STRUCTURAL <br />DRAWINGS AND DETAILS FOR <br />FURTHER INFORMATION. <br />2. WEEP SCREED FOR EXT. <br />PLASTER SHALL BE 4" MIN. <br />ABOVE EARTH OR 2" ABOVE <br />PAVED AREAS. INSTALL AS <br />REQ. <br />(2) LAYERS OF GRADE D BLDG <br />PAPER, TYP. EXT. PLYWOOD <br />SHEATHING. <br />7/8" EXTERIOR PLASTER OVER <br />METAL LATH <br />TEXTURED TERMINATION TAPE <br />SEALANT AND BACKER ROD <br />FLASHING W/ CAULKING <br />EXT.FINISHED GRADE. <br />SLOPE TO DRAIN. <br />CONT. URETHANE SEALANT <br />SELF-ADHERED <br />FLEXIBLE FLASHING <br />4" <br /> <br />M <br />I <br />N <br />. <br />UNDERFLOOR VENTS BEYOND EXTERIOR <br />DOOR PER SCHEDULE, SEE FLOOR <br />PLANS FOR DOOR SWING <br />FINISH FLOOR PER <br />OWNER <br />ALUMINUM THRESHOLD, SET <br />IN FULL BED OF MASTIC <br />LINE OF DOORSTOP BEYOND <br />LINE OF FRAME <br />BEYOND <br />2 <br />1 MAX. <br />ANCHOR @ 24" O.C. 6"@ <br />ENDS, 2" MIN. EMBEDMENT <br />EXTERIOR <br />LANDING <br />1/ <br />4 <br />" <br />3/ <br />4 <br />" <br />5/8" GYP BD. <br />WOOD STUD, PER <br />STRUCTURAL <br />WINDOW FRAME. <br />CONT. SEALANT & <br />BACKER ROD, TYP. <br />SELF-ADHERED FLEXIBLE <br />FLASHING, TYP. <br />GLAZING PER <br />WINDOW TYPES, TYP.V.I.F. <br />7/8" CEMENT PLASTER <br />OVER MTL LATH OVER (2) <br />LAYERS OF GRADE D <br />BLDG PAPER, TYP. <br />INT. WINDOW FASCIA TRIM <br />PER MFG. <br />1/2" TYP. <br />BATT INSULATION <br />NOTE: <br />1. CONTRACTOR SHALL VERIFY COMPATIBILITY BETWEEN MATERIALS PRIOR TO <br />INSTALLATION OF ANY WATERPROOFING OR WATER BARRIER MATERIALS. <br />2. SEE DETAIL NO.7 FOR TYPICAL WINDOW FLASHING. G.C. SHALL COORDINATE AS REQUIRED <br />MANUFACTURER APPROVED <br />WEATHER BARRIER <br />SIDING NOTES: <br />-BLIND NAIL ATTACHMENT <br />-STAGGER JOINTS ON ALL WALLS LESS THAN 11'-0" IN <br />LENGTH (ALLOW FOR MITER AT ALL CORNERS) <br />-INSTALL JOINT FLASHING AT ALL JOINTS INCLUDING <br />BUTT JOINTS AND LAP JOINT AT END OF PLANKS, PER <br />MANUFACTURE'S WRITTEN RECOMMENDATIONS. <br />-MAINTAIN MIN. CLEAR GAP OF 1/4" BETWEEN WEEP <br />SCREED FLASHING & BOTTOM OF HARDIE PLANK <br />-SHIM FURRING TO MAINTAIN STRAIGHTNESS OF <br />SIDING APPLICATION. <br />TY <br />P <br />. <br />1 <br />1 <br />/ <br />4 <br />" <br /> <br />M <br />I <br />N <br />. <br />TY <br />P <br />. <br />1 <br />1 <br />/ <br />4 <br />" <br /> <br />M <br />I <br />N <br />. <br />TY <br />P <br />. <br />1 <br />1 <br />/ <br />4 <br />" <br /> <br />M <br />I <br />N <br />. <br />6" HARDIE PLANK SIDING OR EQUAL <br />5/8" FIBER CEMENT LAP SIDING <br />ATTACHED W/ (RIBBED WAFER- <br />HEAD No. 8 0.375" X 1 1/4" @ 16" O.C.) <br />TY <br />P <br />. <br />3/ <br />4 <br />" <br />1-HR RATED SOFFIT <br />7/8" EXTERIOR PLASTER ON METAL <br />LATH OVER (2) LAYERS BLDG PAPER <br />OVER 1/2" EXT. PLYWOOD SHEATHING <br />STARTER BLOCK <br />SHT. MTL. FLASHING <br />J-MOLDING <br />RIDGE BOARD. NAILING <br />PATTER PER FRAMING PLAN <br />SLOPE -SEE <br />ROOF SHEATHING <br />2 LAYERS OF <br />TYPE 15 FELT <br />FOOR RIDGE STRAP <br />ROOF ASPHALT SHINGLES <br />NOTES: <br />1. ROOF SLOPE-COMP SHINGLES (R905.2) <br />2. RIDGE (R802.3) NAILS (TABLE R602.3(1)) <br />ROOF PLAN <br />SLOPE -SEE <br />ROOF SHEATHING <br />2 LAYERS OF <br />TYPE 15 FELT <br />ROOF ASPHALT <br />SHINGLES <br />NOTES: <br />1. ROOF SLOPE-COMP SHINGLES (R905.2) <br />ROOF PLAN <br />SELF-ADHERED FLEXIBLE <br />FLASHING, TYP. <br />(2) LAYERS OF GRADE D BLDG PAPER, <br />TYP. EXT. PLYWOOD SHEATHING. <br />7/8" EXTERIOR PLASTER OVER <br />METAL LATH <br />8" MIN. SAFF <br />8" <br /> <br />M <br />I <br />N <br />. <br /> <br />S <br />A <br />F <br />F <br />4" <br /> <br />M <br />I <br />N <br />. <br />GALV. SHEET METAL FLASHING. <br />PAINT TO MATCH EXT. TRIM. <br />26 GA. GALV. WEEP SCREED 2X RAFTER PER STRUCTURAL <br />DRAWINGS <br />1/2" CDX PLY SHEATHING W/8d @ <br />6"/6"/12" O.C. (COMMON NAILS) <br />REFERENCE STRUCTURAL DRAWINGS. <br />2X BLKG. <br />B.N. 8D @ 6" O.C. <br />(8) 16D NAILS MIN. <br />NOTE: <br />1. 1 HR RATED WALL <br />WHERE NOTED, SEE <br />FLOOR PLAN <br />2. NO SOFFIT VENTS <br />ON 1 HR OVERHANG <br />1-HR RATED WALL PER WALL TYPES. <br />1/2" WOOD STR. PANEL, <br />REF. STRUC. DRAWINGS <br />(2) 2X4 TOP PLATE <br />1-HR RATED SOFFIT <br />7/8" EXTERIOR PLASTER ON METAL <br />LATH OVER (2) LAYERS BLDG PAPER <br />OVER 1/2" EXT. PLYWOOD SHEATHING <br />UPLIFT FRAMING CLIP PER TABLE R802.11 <br />SIMPSON TIE PER STRUCTURAL <br />DRAWINGS <br />2X FASCIA W/ 2# 10X 3" LONG WOOD <br />SCREWS @ EACH RAFTER <br />EDGE NAIL <br />SHT. MTL. FLASHING <br />2 LAYERS OF 15# FELT <br />W/ 19" OVERLAP. <br />ROOF SHEATHING <br />ROOF ASPHALT SHINGLES <br />SELF-ADHERE FLEXIBLE <br />FLASHING AT ROOF <br />TRANSITION <br />(N) FLASHING TAPE <br />20 G.A. SHEET METAL <br />FLASHING WITH <br />INTEGRATED DRIP EDGE <br />7/8" CEMENT PLASTER <br />OVER MTL LATH OVER (2) <br />LAYERS OF GRADE D <br />BLDG PAPER, TYP. <br />8" S.A.F.F. <br />A35 @ 12" O.C. <br />(E) CEILING JOIST <br />CEILING GYP. BD. <br />5/8" TYPE X GYP. BD. <br />WOOD BLOCKING <br /> S <br />E <br />A <br />L <br />A <br />N <br />T <br />1/ <br />2 <br />" <br /> <br />F <br />I <br />R <br />E <br />PACK BATT INSULATION <br />WITHIN CAVITY <br />ROOF UNDERLAYMENT <br />NOTE: <br />1. 1 HR RATED WALL <br />WHERE NOTED, SEE <br />FLOOR PLAN <br />2. NO SOFFIT VENTS ON <br />1 HR OVERHANG <br />ISSUED <br />DATE: <br />REVISIONS <br />DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS <br />INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE <br />DRAFTER/DESIGNER WHETHER THE PROJECT FOR <br />WHICH THEY ARE MADE BE EXECUTED OR NOT, AND <br />THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN <br />THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY <br />AGREEMENT IN WRITING. <br />NO <br />. <br /> <br />D <br />E <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br /> <br />D <br />A <br />T <br />E <br />DRAFTER/DESIGNER: <br />LUIS N OROZCO <br />562.661.9281 <br />LUIS.OROZCO.A@LIVE.COM <br />DATE: <br />04/24/25 <br />A501 <br />DETAILS - CONSTRUCTION <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />O <br />W <br />N <br />E <br />R <br />: <br /> <br />S <br />I <br />L <br />V <br />I <br />A <br /> <br />T <br />O <br />R <br />R <br />E <br />S <br />15 <br />1 <br />1 <br /> <br />S <br />. <br /> <br />B <br />I <br />R <br />C <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />0 <br />7 <br />2 <br />7 <br />GA <br />R <br />A <br />G <br />E <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />A <br />N <br />AC <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />U <br />N <br />I <br />T <br />09/10/2024 <br />Scale:3" = 1'-0"C3 DR - EXTERIOR DOOR HEAD <br />Scale:3" = 1'-0"C1 DR - EXTERIOR DOOR - THRESHOLD <br />Scale:1 1/2" = 1'-0"B1 RF - EAVE & VENT <br />Scale:3" = 1'-0"A1 EXT - WALL FOOTING - SOG <br />Scale:3" = 1'-0"D2 WD - WINDOW HEAD <br />Scale:3" = 1'-0"A2 EXT - WALL FOOTING - RAISED <br />Scale:3" = 1'-0"C2 <br />DR - EXTERIOR DOOR - <br />THRESHOLD.W <br />Scale:3" = 1'-0"D1 WD - WINDOW SILL <br />NOT USED <br />Scale:3" = 1'-0"A3 EXT - WALL - CLADING <br />Scale:3" = 1'-0"F1 RF - T.O. RIDGE <br />NOT USED <br />Scale:3" = 1'-0"F2 RF - ROOF TO WALL <br />3 <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br /> <br /># <br />2 <br /> <br />0 <br />4 <br />/ <br />2 <br />4 <br />/ <br />2 <br />5 <br />Scale:1 1/2" = 1'-0"B2 RF - RATED EAVE & VENT <br />NOT USED <br />Scale:3" = 1'-0"B3 <br />EXT - WALL & ROOF FLUSH <br />TRANSITION <br />3
The URL can be used to link to this page
Your browser does not support the video tag.