Laserfiche WebLink
STATE & ADMINISTRATIVE REQUIREMENTS <br />A. AT THE TIME OF PERMIT ISSUANCE, CONTRACTOR SHALL SHOW THEIR VALID <br />WORKERS' COMPENSATION INSURANCE CERTIFICATE. <br />B. ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF STATE OF CALIFORNIA <br />TITLE 24 REGARDLESS OF THE INFORMATION INDICATED ON THESE PLANS. IT IS <br />THE RESPONSIBILITY OF THE INDIVIDUAL SUPERVISING THE CONSTRUCTION TO <br />ENSURE THAT THE WORK IS DONE IN ACCORDANCE WITH CODE REQUIREMENTS <br />PRIOR TO REQUESTING INSPECTION. <br />C. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR <br />ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN <br />CONCRETE WASTES ON SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE. <br />D. THE ISSUANCE OF A PERMIT SHALL NOT PREVENT THE BUILDING OFFICIAL FROM <br />REQUIRING THE CORRECTION OF ERRORS ON THESE PLANS OR FROM <br />PREVENTING ANY VIOLATION OF THE CODES ADOPTED BY THE CITY, RELEVANT <br />LAWS, ORDINANCES, RULES AND/OR REGULATIONS <br />E. SEPARATE PERMIT SHALL FIRST BE OBTAINED FROM THE CITY PUBLIC WORKS <br />DEPARTMENT PRIOR TO PLACEMENT OF ANY CONSTRUCTION MATERIALS OR <br />EQUIPMENT IN THE PUBLIC RIGHT OF WAY. <br />F. SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) SHALL BE NOTIFIED <br />IN ACCORDANCE WITH CALIFORNIA STATE LAW PRIOR TO START OF ANY <br />DEMOLITION, ADDITION, AND/OR REMODEL WORK. THE SOUTH COAST AIR QUALITY <br />MANAGEMENT DISTRICT OFFICE IS LOCATED AT 21865 COPLEY DRIVE IN DIAMOND <br />BAR, PHONE NO. (909) 396-2000. BE ADVISED,SCAQMD MAY REQUIRE A 10-DAY WAIT <br />PERIOD PRIOR TO START OF WORK. <br />G. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY <br />VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE <br />STABILIZED TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY. <br />ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE <br />WASHED DOWN BY RAIN OR OTHER MEANS. <br />H. STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE <br />PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND <br />OR WATER. <br />I. TRASH AND CONSTRUCTION RELATED SOLID WASTES MUST BE DEPOSITED INTO A <br />COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND <br />DISPERSAL BY WIND. <br />J. FUELS, OILS, SOLVENTS, AND OTHER TOXIC MATERIALS MUST BE STORED IN <br />ACCORDANCE WITH THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND <br />SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED <br />FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED <br />OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE <br />SYSTEM. <br />K. THE PROJECT SITE SHALL BE KEPT CONTINUOUSLY FENCED IN ACCORDANCE UNTIL <br />THE PROJECT IS FINALED OR APPROVAL TO REMOVE THE FENCE HAS BEEN <br />OBTAINED FROM THE CITY BUILDING DIVISION. 24 HOUR SECURITY SHALL BE <br />PROVIDED ANY TIME THE FENCE CANNOT BE MAINTAINED INTACT. THIS APPLIES <br />IFTHE DWELLING IS GOING TO BE VACANT DURING CONSTRUCTION. <br />L. DUE TO THE POSSIBLE PRESENCE OF LEAD-BASED PAINT, LEAD-SAFE WORK <br />PRACTICES ARE REQUIRED FOR ALL REPAIRS THAT DISTURB THE PAINT IN <br />PRE-1979 BUILDINGS. FAILURE TO DO SO COULD CREATE LEAD HAZARDS THAT <br />VIOLATE CALIFORNIA HEALTH & SAFETY CODE, SECTIONS 17920.10 AND 105256 WITH <br />POTENTIAL FINES FOR VIOLATIONS UP TO$5,000 (SECTION (d) AMENDED) OR <br />IMPRISONMENT FOR NOT MORE THAN 6 MONTHS IN THE COUNTY JAIL OR BOTH. <br />M. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS <br />PROHIBITED. NO SOLID WASTE, PETROLEUM BY-PRODUCTS, SOIL PARTICULATE, <br />CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON <br />CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, <br />CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN <br />SYSTEM. <br />ISSUED <br />DATE: <br />REVISIONS <br />DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS <br />INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE <br />DRAFTER/DESIGNER WHETHER THE PROJECT FOR <br />WHICH THEY ARE MADE BE EXECUTED OR NOT, AND <br />THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN <br />THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY <br />AGREEMENT IN WRITING. <br />NO <br />. <br /> <br />D <br />E <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br /> <br />D <br />A <br />T <br />E <br />DRAFTER/DESIGNER: <br />LUIS N OROZCO <br />562.661.9281 <br />LUIS.OROZCO.A@LIVE.COM <br />DATE: <br />G103 <br />GENERAL NOTES <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />O <br />W <br />N <br />E <br />R <br />: <br /> <br />S <br />I <br />L <br />V <br />I <br />A <br /> <br />T <br />O <br />R <br />R <br />E <br />S <br />15 <br />1 <br />1 <br /> <br />S <br />. <br /> <br />B <br />I <br />R <br />C <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />0 <br />7 <br />2 <br />7 <br />GA <br />R <br />A <br />G <br />E <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />A <br />N <br />AC <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />U <br />N <br />I <br />T <br />09/10/2024 <br />FINISH HARDWARE SHALL BE SELECTED BY THE DESIGNER. CONTRACTOR SHALL <br />PROVIDE SOLID BLOCKING AT ALL TOWEL BARS, TOILET PAPER HOLDERS, ETC. <br />CONTRACTOR SHALL PROVIDE AN ALLOWANCE FOR ALL HARDWARE FOR BIDDING <br />PURPOSES (U.N.O.). <br />EXTERIOR FINISH MATERIALS SHALL BE APPLIED OVER REQUIRED APPROVED <br />WATERPROOFING AS SPECIFIED BELOW. <br />PAINTED WOOD SURFACES SHALL BE SEALED, SANDED, SHOP PRIMED (U.N.O.) TO <br />RECEIVE FINISH PAINT COAT. <br />INTERIOR TRIM AND MILLWORK SHALL BE FURNISHED AND PROPERLY INSTALLED AS <br />SPECIFIED AND DETAILED ON THE PLANS. RUBBERIZED MOULDINGS SHALL BE SPECIAL <br />ORDERED WHEN REQUIRED FOR RADUIS AND/OR CURVED SURFACES AND ELEMENTS. <br />FLASHING <br />ALL PLUMBING PIPES SHALL BE FULLY INSULATED <br />FLASHING MATERIAL SHALL BE MINIMUM 26 GAUGE GALVANIZED STEEL. <br />FLASH AND COUNTER FLASH ALL ROOF TO WALL CONDITIONS. FLASH AND CAULK ALL <br />VERTICAL TO HORIZONTAL JOINTS AND PLANE VARIATIATIONS. WOOD BEAMS, <br />CORBELS, OUTLOOKERS, PROJECTIING THROUGH EXTERIOR WALLS, FLOORS, ROOF <br />SURFACES AND/OR BALCONY, VERTICLE PIPES ETC. SHALL BE FLASHED AND <br />CAULKED. <br />GALVANIZED FLASHING SHALL BE CLEARED OF ALL FLUX AND SHOP PAINTED AS <br />SPECIFIED UNDER PAINTING. <br />EXTERIOR OPENINGS SHALL BE PROPERLY FLASHED WITH APPROVED WATER <br />PROOFING MATERIALS. <br />JOINTS AROUND DOORS, WINDOWS, MUDSILLS, WEEP SCREEDS, TRIM <br />INTERSECTIONS AND ALL EXTERIOR OPENINGS SHALL BE COMPLETELY SEALED WITH <br />THE HIGHEST GRADE OF NON-HARDENING, NON-STAINING ELASTIC COMPOUND <br />CAULKING AFTER INSTALLATION OF SURROUNDING WORK IN A QUICK AND TIMELY <br />MANNER (AS SOON AS POSSIBLE). <br />EXTERIOR CEMENT PLASTER SHALL BE UNDERLAIN WITH A MINIMUM OF TWO LAYERS <br />GRADE D PAPER AND MESH GALVANIZED SELF-FURRING METAL LATH 1.75 #/CU.FT. OR <br />EQUIVALENT WITH 15# SATURATED BUILDING FELT AT PLYW OOD. <br />WEEP SCREEDS SHALL BE INSTALLED AT THE FOUNDATION SILL LINE ON ALL <br />EXTERIOR WALLS AND AS SHOWN ON DRAWINGS. WEEP SCREED SHALL HAVE A DRIP <br />LINE FOR DRAINING TRAPPED WATER TO THE EXTERIOR OF THE BUILDING. <br />FLASHIING, CORNER BEADS, SCREEDS, ETC., SHALL BE INSTALLED PROPERLY AS <br />APPROPRIATE TO CONDITION AND AS SPECIFIED <br />THERMAL AND MOISTURE PROTECTION <br />ALL WORK SHALL COMPLY WITH TITLE 24 REQUIREMENTS <br />INSULATION SHALL BE FIBERGLASS BATTS WITH KRAFT PAPER BACKING AND SHALL <br />CONFORM TO FEDERAL SPECIFICATIONS. <br />MINERAL FIBER INSULATION SHALL BE INSTALLED IN JOIST SPACES WHENEVER A <br />PLUMBING PIPE OR DUCT PENETRATES A FLOOR-CEILING ASSEMBLY AND/OR WHEN <br />THEY PASS THROUGH THE PLANE OF THE FLOOR-CEILING ASSEMBLY FROM A WALL. <br />INSULATION SHALL EXTEND 12" PAST THE DUCTING AND/OR THE PIPING. <br />THE CERTIFICATE OF COMPLIANCE SHALL BE SIGNED BY THE INSULATING SUB- <br />CONTRACTOR AND GENERAL CONTRACTOR AND SHALL BE PROMINATELY POSTED ON <br />THE CONSTRUCTION SITE. <br />ALL INSULATION MATERIALS SHALL BE CERTIFIED BY THE MANUFACTURER AND <br />COMPLY WITH THE CALIFORNIA QUALITY STANDARDS FOR INSULATING MATERIALS. <br />R-3 INSULATION OR GREATER SHALL BE INSTALLED ON WATER INLET AND OUTLET <br />PIPES FOR THE FIRST 5 FEET OF UNCONDITIONED SPACE U.N.O. (SEE TITLE 24 <br />CALCULATIONS) <br />FINISH CARPENTRY <br />WOOD TRIM SHALL BE IN SINGLE LENGTHS WHEN POSSIBLE <br />MITER INTERIOR TRIM AT JOINTS <br />KERF OR BACK CUT FLAT TRIM MEMBERS AS REQUIRED TO PREVENT WARPING. <br />SET NAIL HEADS TO RECEIVE PUTTY. <br />BASE MOULD SHALL MATCH EXISTING HOUSE <br />DOOR AND WINDOW CASINGS AND DRYWALL BULLNOSE FINISH SHALL MATCH <br />EXISTING OR BE PER SPECS. <br />DOORS SHALL BE HUNG IN TRUE VERTICAL PLANE WITHOUT WARP OR WIND AND BE <br />FITTED SO AS TO HAVE 1/16" CLEARANCE ABOVE THRESHOLDS WHERE DOORS OPEN <br />INTO ROOMS. OTHERWISE, CLEARANCE SHALL BE 3/8" ABOVE THE FLOORS FOR <br />INTERIOR DOORS. THE CLEARANCE AT THE HEAD AND JAMB SHALL BE 3/32". EXTERIOR <br />DOORS SHALL BE FULLY WEATHERSTRIPPED. <br />DOORKNOBS SHALL BE 36" ABOVE THE FINISHED FLOOR. LOCATION OF DOOR PULLS <br />AND DEAD BOLTS SHALL BE LOCATED BY OWNERS. HANDICAPPED REQUIREMENTS <br />SHALL APPLY AS REQUIRED IN HANDICAPPED SPACES AS REQUIRED BY ADA <br />STANDARDS. <br />PAINT <br />PAINTER SHALL FURNISH MATERIALS, EQUIPMENT AND PERFORM ALL LABOR <br />REQUIRED TO COMPLETE "PAINTING" WORK IN THE BEST METHOD AND STANDARDS <br />OF THE TRADE - ALL INTERIOR AND EXTERIOR SURFACES, EXCLUDING THOSE ITEMS <br />OR AREAS WITH FACTORY APPLIED FINISHES OR AS DIRECTED. <br />THE CONTRACTOR SHALL INSURE EVEN APPLICATION PROPER CONSISTENCY DURING <br />FAVORABLE WEATHER CONDITIONS. <br />PROPER CLEANING AND SURFACE PREPARATION SHALL PRECEDE APPLICATION OF <br />PRIMER COAT PLUS TWO FINISH COATS. PRIMER SHALL BE COLORED TO MATCH <br />FINISH COLOR. <br />WITH THE EXCEPTION OF TRIM AND TOUCH-UP WORK, PAINT SHALL BE BATCHED IN 5 <br />GALLON CONTAINERS PRIOR TO APPLICATION. <br />ALL UNPAINTED SURFACES SHALL BE ADEQUATELY PROTECTED FROM PAINT OR <br />DAMAGE. <br />CONTRACTOR SHALL PROVIDE (6) SIX DIFFERENT INTERIOR COLORS THROUGHOUT <br />THE ENTIRE PROJECT NEW AND OR EXISTING. PAINT AND/OR STAIN COLORS SHALL BE <br />SPECIFIED BY DESIGNER. <br />CONTRACTORS SHALL PROVIDE (2) TWO DIFFERENT EXTERIOR COLORS AT THE <br />EXTERIOR, NEW AND EXISTING. PAINT AND STAIN COLORS SHALL BE SPECIFIED BY <br />DESIGNER. <br />CONTRACTORS SHALL PROVIDE OWNERS WITH (3) THREE COLOR SAMPLES OF EACH <br />COLOR, APPROXIMATELY 3'-0" X 3'-0" COLOR SAMPLE, PRIOR TO WORK BEING <br />PERFORMED. <br />GRADING NOTES <br />ALL FOOTINGS SHALL BE FOUNDED IN UNDISTURBED NATURAL SOIL PER CODE. <br />IN THE EVENT EXCAVATIONS REVEAL UNFAVORABLE CONDITIONS, THE SERVICES OF A <br />SOILS ENGINEER AND/OR GEOLOGIST MAY BE REQUIRED. CONTACT THE DESIGNER <br />IMMEDIATELY. <br />ALL CONCENTRATED DRAINAGE, INCLUDING ROOF WATER, SHALL BE CONDUCTED, VIA <br />GRAVITTY TO THE STREET OR AN APPROVED LOCATION AT A 2% MINIMUM. <br />ALL FILL OR BACKFILL SHALL BE COMPACTED BY MECHANICAL MEANS TO A MINIMUM <br />90% RELATIVE COMPACTION AS DETERMINED BY ASTM METHOD D-1557. SUBDRAINS <br />SHALL BE PROVIDED WHERE REQUIRED BY CODE. <br />MISCELLANEOUS DOOR & WINDOW NOTES <br />1. ALL GLASS WITHIN 18" OF THE FINISHED FLOOR SHALL BE FULL TEMPERED. <br />TEMPERED GLASS REQ'S PERMANENT ETCHED LABEL EXC. SPANDREL GLASS <br />REMOVABLE PAPER LABEL OK PER SECTION 2406.2 UBC 2001. <br />2. ALL EGRESS OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL BE PROVIDED <br />WITH A MINIMUM CLEAR OPENING OF 5.7 SQUARE FEET WITH THE MINIMUM NET <br />WIDTH DIMENSION OF THE OPENING NOT LESS THAN 20". WHERE WINDOWS ARE <br />PROVIDED AS A MEANS OF EGRESS OR RESCUE. THEY SHALL HAVE A FINISHED <br />SILL HEIGHT OF NOT MORE THAN 44' ABOVE THE ADJACENT FINISHED FLOOR. <br />3. ALL EXTERIOR DOORS AND WINDOWS SHALL COMPLY WITH THE BUILDING CODE <br />SECURITY REQUIREMENTS AS ADOPTED BY THE LOCAL BUILDING DEPARTMENT <br />AND SPECIFIED ELSEWHERE ON THIS SHEET. <br />4. FRENCH DOORS AND WINDOWS USED AS A MEANS TO PROVIDE MINIMUM <br />VENTILATION REQUIREMENTS SHALL BE OPEN-ABLE AND SHALL BE PROVIDED <br />WITH SCREENS UNLESS NOTED OTHERWISE ON THE PLANS AND SPECIFICATIONS. <br />ALL SUCH DOORS AND WINDOWS SHALL BE EQUIPPED WITH A MECHANICAL HOLD <br />OPEN DEVICE. <br />5. CONTRACTOR SHALL VERIFY EXACT ROUGH OPENING HEIGHT AND WIDTH OF ALL <br />DOORS AND WINDOWS WITH DOOR AND WINDOW MANUFACTURER PRIOR TO <br />START OF ROUGH FRAMING. ROUGH FRAMING SUB-CONTRACTOR IS <br />RESPONSIBLE FOR PROVIDING ALL FRAMING NAILERS AND FILLERS AS SHOWN ON <br />WINDOW AND DOOR DETAILS, MANUFACTURE'S STANDARD DETAILS AND AS MAY <br />OTHERWISE BE REQUIRED FOR THE PROPER INSTALLATION OF ALL DOORS AND <br />WINDOWS. <br />6. ALL PANEL TYPE DOORS SHALL BE UNITS MANUFACTURED BY T.M. COBB CO. <br />PANEL TYPE DOORS SHALL BE F-66 TYPE UNLESS NOTED OTHERWISE ON PLANS. <br />7. ALL WINDOWS ARE BASED ON MILGARD ALUMINUM SERIES. FRENCH WINDOWS <br />SHALL BE PROVIDED WITH FULLY TEMPERED GLASS. WINDOW UNITS SHALL BE <br />PROVIDED WITH CLEAR DBL. GLAZING UNLESS NOTED OTHERWISE ON PLANS. <br />PROVIDE FULLY TEMPERED GLASS AT CERTAIN WINDOWS AS SPECIFIED ON <br />WINDOW SCHEDULE. <br />8. WINDOW UNITS SHALL BE FULLY ASSEMBLED UNITS CONSTRUCTED PER <br />SPECIFICATIONS <br />9. WINDOW UNITS SHALL BE HINGED AS INDICATED ON EXTERIOR ELEVATIONS <br />AND/OR PLANS. <br />10. WINDOW UNITS SHALL BE DELIVERED TO THE JOB SITE WITH ALL HARDWARE <br />SUCH AS OPERATORS, CRANK, OPERATOR ARM, LOCK, ETC. <br />11. OWNER SHALL PROVIDE ALL NECESSARY HARDWARE NOT INCLUDED IN <br />MANUFACTURED UNIT CONTRACTOR TO INSTALL ALL HARDWARE. <br />12. ALL DOOR HARDWARE SHALL BE PROVIDED BY OWNER AND INSTALLED BY <br />CONTRACTOR. <br />13. ALL DOOR UNITS AND THEIR RESPECTIVE FRAMES SHALL BE PAINT GRADE. <br />14. SAMPLE WINDOW TO BE APPROVED WITH SIGNED SHOP DRAWINGS BY OWNER/ <br />DESIGNER. <br />15. UNLESS NOTED OTHERWISE, ALL EXTERIOR SWING DOORS TO BE SUPPLIED WITH <br />MILL FINISHED EXTRUDED BRONZE PEMPO THRESHOLDS 114 B OR 145 B/ WITH 16 <br />oz. COPPER DRAIN PAN. THRESHOLDS TO BE POLISHED TO REMOVE MILL <br />MARKINGS. PEMKO SPRING BRONZE WEATHER STRIPPING @ HEAD AND JAMBS. <br />16. CAULK ALL INTERIOR/ EXTERIOR PLASTER JOINTS. <br />17. ALL GLAZING ON DOORS AND WINDOWS TO BE DBL GLAZE 'LOW E' INSULATED <br />GLASS. <br />SECURITY NOTES (WHERE APPLICABLE): <br />1. ALL EXTERIOR DOOR AND WINDOW OPENINGS ARE SECURITY OPENINGS, AND ALL <br />NOTES SHALL APPLY. <br />2. WOOD FLUSH-TYPE DOORS SHALL BE 1 3/4" THICK MINIMUM AND SHALL BE OF <br />SOLID CORE CONSTRUCTION. <br />3. HOLLOW CORE DOORS OR DOORS LESS THAN 1 3/4" IN THICKNESS SHALL BE <br />COVERED ON THE INSIDE FACE WITH 16 OZ SHEET METAL ATTACHED WITH <br />SCREWS AT 6" O/C AROUND THE PERIMETER, OR EQUIVALENT. <br />4. GLAZED OPENINGS WITHIN 4" OF THE DOOR LOCK, WHEN THE DOOR IS IN THE <br />CLOSED POSITION. SHALL BE FULLY TEMPERED GLASS OR APPROVED BURGLARY <br />RESISTANT MATERIAL, OR SHALL BE PROTECTED BY METAL BARS, SCREENS OR <br />GRILLES HAVING A MAXIMUM OPENING OF 2". THE PROVISIONS OF THIS SECTION <br />SHALL NOT APPLY TO VIEW PORTS OR WINDOWS, WHICH DO NOT EXCEED 2" IN <br />THEIR GREATEST DIMENSION. <br />5. GLASS DOORS SHALL HAVE FULLY TEMPERED GLASS . TEMPERED GLASS REQ'S <br />PERMANENT ETCHED LABEL EXC. SPANDREL GLASS REMOVABLE PAPER LABEL <br />OK PER SECTION 2406.2 UBC 2001. <br />6. DOORSTOPS OF IN-SWINGING DOORS SHALL BE OF ONE-PIECE CONSTRUCTION <br />WITH THE JAMB, OR JOINED BY RABBET TO THE JAMB. <br />7. ALL PIN-TYPE HINGES WHICH ARE ACCESSIBLE FROM OUTSIDE THE SECURED <br />AREA WHEN THE DOOR IS CLOSED SHALL HAVE NON-REMOVABLE HINGE PINS. IN <br />ADDITION THEY SHALL HAVE MINIMUM ¼" DIAMETER STEEL JAMB STUD WITH ¼" <br />MINIMUM PROJECTION UNLESS THE HINGES ARE SHAPED TO PREVENT REMOVAL <br />OF THE DOOR IF THE HINGE PINS ARE REMOVED. <br />8. THE STRIKE PLATE FOR LATCHES AND THE HOLDING DEVICE FOR PROJECTION <br />DEAD BOLTS IN WOOD CONSTRUCTION SHALL BE SECURED TO THE JAMB AND <br />THE WALL FRAMING WITH SCREWS NOT LESS THAN 2 1/1" IN LENGTH. <br />9. DEAD BOLTS SHALL HAVE HARDENED INSERTS; PROVIDE DEADLOCKING LATCH <br />KEY OPERATED LOCKS ON THE EXTERIOR; LOCKS SHALL BE OPENABLE WITH OUT <br />KEY, SPECIAL KNOWLEDGE OR SPECIAL EFFORT FROM THE INTERIOR. <br />10. STRAIGHT DEAD BOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN <br />EMBEDMENT OF NOT LESS THAN 5/8". <br />11. A HOOK SHAPED OR AN EXPANDING-LUG DEAD BOLT SHALL HAVE A MINIMUM <br />THROW OF 3/4". <br />12. CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDERS LOCKS WHENEVER <br />THE CYLINDER PROJECTS BEYOND THE FACE OF THE DOOR OR IS OTHERWISE <br />ACCESSIBLE TO GRIPPING TOOLS. <br />13. SLIDING GLASS DOORS AND WINDOWS SHALL BE EQUIPPED WITH LOCKING <br />DEVICES AND SHALL BE SO CONSTRUCTED AND INSTALLED THAT THEY REMAIN <br />INTACT AND ENGAGED WHEN SUBJECTED TO THE TESTS SPECIFIED IN SECTIONS <br />91.6731 AND 91.6732. <br />14. SLIDING GLASS DOORS AND WINDOWS SHALL BE PROVIDED WITH A DEVICE IN <br />THE UPPER CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND <br />REMOVING OF THE MOVING PANEL IN THE CLOSED OR PARTIALLY OPEN POSITION. <br />15. SCREENS, BARRICADES, OR FENCES MADE OF MATERIAL WHICH PRECLUDES <br />HUMAN CLIMBING SHALL BE PROVIDED AT EVERY PORTION OF EVERY ROOF, <br />BALCONY, OR SIMILAR SURFACE WHICH IS WITHIN 8' OF A UTILITY POLE OR <br />SIMILAR STRUCTURE. <br />16. PROVIDE SAFETY GLAZING IN THE FOLLOWING LOCATIONS PER CODE. TEMPERED <br />GLASS REQ'S PERMANENT ETCHED LABEL EXC. SPANDREL GLASS REMOVABLE <br />PAPER LABEL OK PER CODE <br />SLIDING OR SWINGING DOORS <br />1. TUB AND/OR SHOWER ENCLOSURES AND GLAZING IN WALLS LESS THAN 60" <br />ABOVE THE STANDING SURFACE OF TUBS OR SHOWERS. <br />2. GLAZING WITHIN A 24" ARC OF A DOOR. <br />CONCRETE <br />NOTE: STRUCTURAL AND GEOLOGICAL NOTES AND DRAWING SHALL SUPERSEDE THE <br />FOLLOWING <br />WATER FOR CONCRETE MIXING SHALL BE FRESH, CLEAN AND SUITABLE FOR <br />DOMESTIC PURPOSES. <br />ALL EMBEDDED HARDWARE SHALL BE ICBO APPROVED. REINFORCEMENT, BOLTS, <br />ANCHORS, SLEEVES, HOLD DOWNS ETC. SHALL BE FREE OF DIRT AND RUST PRIOR TO <br />POURING OF CONCRETE. <br />ALL SHOT PINS, REDHEADS AND MISCELLANEOUS HARDWARE SHALL BE ICBO <br />APPROVED <br />ALL WOOD SHALL BE A MINIMUM OF 6" ABOVE FINISHED GRADE <br />SILL PLATES SHALL BE INSTALLED WITH FULL BEARING ON FOOTING WALL OR MORTAR <br />BED. ALL WOOD CONTACTING CONCRETE SHALL BE PRESSURE TREATED. <br />ALL WORK SHALL BE PLUMB, SQUARE ACCORDING TO THE PLANS, U.N.O. <br />EXPOSED CONCRETE SURFACES SHALL HAVE A BROOM FINISH PROVIDING A NON-SLIP <br />SURFACE U.N.O.. <br />ALL FOOTINGS SHALL SET ON FIRM NATURAL SOIL OR APPROVED COMPACTED FILL. <br />REFER TO SOILS REPORT. LOAD BEARING FOOTINGS SHALL EXTEND BELOW NATURAL <br />GRADE. <br />REMOVE ALL WATER FROM TRENCHES AND FOUNDATION PRIOR TO POURING THE <br />CONCRETE . FORMS SHALL BE WETTED. <br />CONCRETE SHALL BE PLACED AS QUICKLY AS POSSIBLE TO PREVENT SEPARATION <br />OF MATTER. <br />CONCRETE SLABS SHALL BE 3 1/2" MINIMUM (U.N.O.) OVER 4" COURSE AGGREGATE <br />BASE OR SAND BASE WITH MOISTURE BARRIER. PROVIDE "VISQUEEN" OR EQUIVALENT <br />VAPOR BARRIER BETWEEN SLAB AND BASE. (VERIFY WITH STRUCTURAL PLANS AND <br />NOTES ) <br />CONTRACTOR WILL REPLACE AND/OR REPAIR EXISTING DRIVEWAY, PATIOS , <br />WALKWAYS ETC. WHICH MAY BE DAMAGED DURING CONSTRUCTION. <br />MASONRY <br />STRUCTURAL NOTES AND DRAWING SHALL SUPERSEDE THE FOLLOWING: <br />MASONRY SHALL BE SET IN RUNNING BOND PATTERN U.N.O. <br />MASONRY SHALL MEET THE REQUIREMENTS FOR "HOLLOW LOAD BEARING CONCRETE <br />MASONRY UNITS", ASTM C-90 AND COMPLY WITH LATEST EDITION OF THE UNIFORM <br />BUILDING CODE. <br />MORTAR AND GROUT SHALL BE OF FLUID CONSISTENCY AND RETEMPERING IS NOT <br />ALLOWED. <br />WALLS SHALL BE TRUE AND PLUMB. ALL JOINTS SHALL BE FULL FLUSH, BROOM FINISH. <br />ALL CELLS CONTAINING REINFORCEMENT SHALL BE FILLED SOLID WITH GROUT. WHEN <br />TOTAL GROUT POUR EXCEED 8 FEET IN HEIGHT, THE GROUT SHALL BE PLACED IN 4 <br />FOOT LIFTS AND SPECIAL INSPECTION SHALL BE PROVIDED AS REQUIRED. <br />ALL MASONRY WORK SHALL BE LEFT CLEAN, FREE FROM EXCESS CEMENT AND <br />EFFLORESCENCE AND IN A CONDITION SUITABLE FOR PAINTING, CEMENT PLASTER OR <br />NO FINISH. <br />METALS <br />STRUCTURAL NOTES AND DRAWING SHALL SUPERSEDE THE FOLLOWING: <br />CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR AND MATERIAL NECESSARY <br />TO MAKE ALL FLASHING, VALLEYS, CHIMNEYS, RIDGES, SADDLES, CONDUCTORS AND <br />ALL CONNECTIONS WATERTIGHT. <br />ALL GALVANIZED STEEL SHALL BE 24 GAUGE MINIMUM U.N.O. <br />ALL WORK SHALL BE SHOP PRE-FABRICATED WHEN POSSIBLE TO LIMIT SOLDERING <br />JOINTS WHEN INSTALLED. <br />ALL EXPOSED STEEL SHALL BE DOUBLE GALVANIZED. <br />PROVIDE AND SET ALL IRON AND STEEL BEAMS, PIPE COLUMNS, ANCHORS AND <br />MISCELLANEOUS ETC., AS SHOWN ON DRAWINGS. <br />PROVIDE AND INSTALL ALL FRAMING HARDWARE REQUIRED FOR POSTS, BEAMS, <br />RAFTERS, JOISTS AND OTHER FRAMING MEMBERS AS REQUIRED. <br />PROVIDE AND INSTALL ALL ROOF AND DECK DRAINS AND INTERIOR DOWNSPOUTS AS <br />MAY BE REQUIRED TO DRAIN ALL ROOF AND DECK WATER AND CONDUCT IT THROUGH <br />ENCLOSED PIPING AND TO THE STREET. <br />WOOD, PLASTIC & CARPENTRY <br />STRUCTURAL NOTES AND DRAWING SHALL SUPERSEDE THE FOLLOWING: <br />ALL WORK SHALL CONFORM TO GENERAL CONSTRUCTION REQUIREMENTS AND <br />CONSTRUCTION PROVISIONS OF THE LATEST EDITION UBC. ALL WORK PERFORMED <br />SHALL BE OF HIGH QUALITY WORKMANSHIP. <br />DOOR FRAMES SHALL BE A SUITABLE DEPTH TO RECEIVE WALL FINISHED AS SHOWN <br />ON DETAILS <br />GALVANIZED NAILS SHALL BE USED FOR ALL EXTERIOR WOOD <br />ALL FINISH WOOD, EXTERIOR AND INTERIOR SHALL BE NAILED WITH FINISH NAILS AND <br />COUNTERSUNK. <br />GLUE AND NAIL PLYWOOD SUB-FLOORING. (SEE STRUCTURAL PLANS AND DRAWINGS) <br />ALL BOLTS AND NUTS BEARING ON WOOD SHALL HAVE WASHERS. (SEE STRUCTURAL <br />PLANS AND DRAWINGS) <br />CROSS BRIDGE OR SOLID BLOCK FLOOR JOISTS EVERY 8 FEET MAX. AND SOLID BLOCK <br />AT SUPPORTS. BLOCK AT PLYWOOD SUB-FLOOR EDGES. <br />WOOD TRIM SHALL BE IN SINGLE LENGTHS WHEN POSSIBLE. <br />MITER INTERIOR TRIM AT JOINTS <br />KERF OR BACK CUT FLAT TRIM MEMBERS AS REQUIRED TO PREVENT WARPING <br />WORK SHALL BE INSTALLED AND SANDED AND NAIL HEADS SET TO RECEIVE PUTTY <br />READY FOR PAINTING OR STAINING. <br />WOOD CASINGS, BASE AND CROWN MOULDS, WINDOW STOOL AND APRONS, RUNNING <br />TRIM AND CABINETS SHALL BE AS DETAILED AND SPECIFIED. <br />QUARTER ROUND BASE SHOE AT WOOD FLOORS SHALL MATCH EXISTING <br />FRAMING SHALL BE PERFORMED IN A PROFESSIONAL MANNER BY SKILLED <br />CRAFTSPERSONS. <br />ALL WOODWORK, BLOCKING, GROUNDS, ROUGH BUCKS AND MISC. FIRE BLOCKING <br />SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS OR <br />ORDINANCES. <br />THE FRAMING SUB-CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND <br />FITTING OF WOOD MEMBERS AS REQUIRED BY PLUMBING, ELECTRICAL, HEATING AND <br />MECHANICAL CONTRACTORS. <br />ALL GROUNDS AND/OR NAILERS SHALL BE PROVIDED AND INSTALLED AS REQUIRED <br />FOR PLASTERING, DRYWALL WORK, WOOD BASES AND TRIMS AND SO FORTH AS <br />REQUIRED. FURR AND BLOCK AS REQUIRED FOR ARCHITECTURAL FEATURES. <br />FURNISH ALL ROUGH AND FINISH HARDWARE AS REQUIRED TO COMPLETE <br />CONSTRUCTION OF THE JOB WITH HIGH QUALITY CRAFTSMANSHIP.