STATE & ADMINISTRATIVE REQUIREMENTS
<br />A. AT THE TIME OF PERMIT ISSUANCE, CONTRACTOR SHALL SHOW THEIR VALID
<br />WORKERS' COMPENSATION INSURANCE CERTIFICATE.
<br />B. ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF STATE OF CALIFORNIA
<br />TITLE 24 REGARDLESS OF THE INFORMATION INDICATED ON THESE PLANS. IT IS
<br />THE RESPONSIBILITY OF THE INDIVIDUAL SUPERVISING THE CONSTRUCTION TO
<br />ENSURE THAT THE WORK IS DONE IN ACCORDANCE WITH CODE REQUIREMENTS
<br />PRIOR TO REQUESTING INSPECTION.
<br />C. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR
<br />ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN
<br />CONCRETE WASTES ON SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE.
<br />D. THE ISSUANCE OF A PERMIT SHALL NOT PREVENT THE BUILDING OFFICIAL FROM
<br />REQUIRING THE CORRECTION OF ERRORS ON THESE PLANS OR FROM
<br />PREVENTING ANY VIOLATION OF THE CODES ADOPTED BY THE CITY, RELEVANT
<br />LAWS, ORDINANCES, RULES AND/OR REGULATIONS
<br />E. SEPARATE PERMIT SHALL FIRST BE OBTAINED FROM THE CITY PUBLIC WORKS
<br />DEPARTMENT PRIOR TO PLACEMENT OF ANY CONSTRUCTION MATERIALS OR
<br />EQUIPMENT IN THE PUBLIC RIGHT OF WAY.
<br />F. SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) SHALL BE NOTIFIED
<br />IN ACCORDANCE WITH CALIFORNIA STATE LAW PRIOR TO START OF ANY
<br />DEMOLITION, ADDITION, AND/OR REMODEL WORK. THE SOUTH COAST AIR QUALITY
<br />MANAGEMENT DISTRICT OFFICE IS LOCATED AT 21865 COPLEY DRIVE IN DIAMOND
<br />BAR, PHONE NO. (909) 396-2000. BE ADVISED,SCAQMD MAY REQUIRE A 10-DAY WAIT
<br />PERIOD PRIOR TO START OF WORK.
<br />G. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY
<br />VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE
<br />STABILIZED TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY.
<br />ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE
<br />WASHED DOWN BY RAIN OR OTHER MEANS.
<br />H. STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE
<br />PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND
<br />OR WATER.
<br />I. TRASH AND CONSTRUCTION RELATED SOLID WASTES MUST BE DEPOSITED INTO A
<br />COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND
<br />DISPERSAL BY WIND.
<br />J. FUELS, OILS, SOLVENTS, AND OTHER TOXIC MATERIALS MUST BE STORED IN
<br />ACCORDANCE WITH THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND
<br />SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED
<br />FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED
<br />OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE
<br />SYSTEM.
<br />K. THE PROJECT SITE SHALL BE KEPT CONTINUOUSLY FENCED IN ACCORDANCE UNTIL
<br />THE PROJECT IS FINALED OR APPROVAL TO REMOVE THE FENCE HAS BEEN
<br />OBTAINED FROM THE CITY BUILDING DIVISION. 24 HOUR SECURITY SHALL BE
<br />PROVIDED ANY TIME THE FENCE CANNOT BE MAINTAINED INTACT. THIS APPLIES
<br />IFTHE DWELLING IS GOING TO BE VACANT DURING CONSTRUCTION.
<br />L. DUE TO THE POSSIBLE PRESENCE OF LEAD-BASED PAINT, LEAD-SAFE WORK
<br />PRACTICES ARE REQUIRED FOR ALL REPAIRS THAT DISTURB THE PAINT IN
<br />PRE-1979 BUILDINGS. FAILURE TO DO SO COULD CREATE LEAD HAZARDS THAT
<br />VIOLATE CALIFORNIA HEALTH & SAFETY CODE, SECTIONS 17920.10 AND 105256 WITH
<br />POTENTIAL FINES FOR VIOLATIONS UP TO$5,000 (SECTION (d) AMENDED) OR
<br />IMPRISONMENT FOR NOT MORE THAN 6 MONTHS IN THE COUNTY JAIL OR BOTH.
<br />M. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS
<br />PROHIBITED. NO SOLID WASTE, PETROLEUM BY-PRODUCTS, SOIL PARTICULATE,
<br />CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON
<br />CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED,
<br />CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN
<br />SYSTEM.
<br />ISSUED
<br />DATE:
<br />REVISIONS
<br />DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
<br />INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
<br />DRAFTER/DESIGNER WHETHER THE PROJECT FOR
<br />WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
<br />THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
<br />THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
<br />AGREEMENT IN WRITING.
<br />NO
<br />.
<br />
<br />D
<br />E
<br />S
<br />C
<br />R
<br />I
<br />P
<br />T
<br />I
<br />O
<br />N
<br />
<br />D
<br />A
<br />T
<br />E
<br />DRAFTER/DESIGNER:
<br />LUIS N OROZCO
<br />562.661.9281
<br />LUIS.OROZCO.A@LIVE.COM
<br />DATE:
<br />G103
<br />GENERAL NOTES
<br />PR
<br />O
<br />P
<br />E
<br />R
<br />T
<br />Y
<br />
<br />O
<br />W
<br />N
<br />E
<br />R
<br />:
<br />
<br />S
<br />I
<br />L
<br />V
<br />I
<br />A
<br />
<br />T
<br />O
<br />R
<br />R
<br />E
<br />S
<br />15
<br />1
<br />1
<br />
<br />S
<br />.
<br />
<br />B
<br />I
<br />R
<br />C
<br />H
<br />
<br />S
<br />T
<br />.
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />0
<br />7
<br />2
<br />7
<br />GA
<br />R
<br />A
<br />G
<br />E
<br />
<br />C
<br />O
<br />N
<br />V
<br />E
<br />R
<br />S
<br />I
<br />O
<br />N
<br />
<br />T
<br />O
<br />
<br />A
<br />N
<br />AC
<br />C
<br />E
<br />S
<br />S
<br />O
<br />R
<br />Y
<br />
<br />D
<br />W
<br />E
<br />L
<br />L
<br />I
<br />N
<br />G
<br />
<br />U
<br />N
<br />I
<br />T
<br />09/10/2024
<br />FINISH HARDWARE SHALL BE SELECTED BY THE DESIGNER. CONTRACTOR SHALL
<br />PROVIDE SOLID BLOCKING AT ALL TOWEL BARS, TOILET PAPER HOLDERS, ETC.
<br />CONTRACTOR SHALL PROVIDE AN ALLOWANCE FOR ALL HARDWARE FOR BIDDING
<br />PURPOSES (U.N.O.).
<br />EXTERIOR FINISH MATERIALS SHALL BE APPLIED OVER REQUIRED APPROVED
<br />WATERPROOFING AS SPECIFIED BELOW.
<br />PAINTED WOOD SURFACES SHALL BE SEALED, SANDED, SHOP PRIMED (U.N.O.) TO
<br />RECEIVE FINISH PAINT COAT.
<br />INTERIOR TRIM AND MILLWORK SHALL BE FURNISHED AND PROPERLY INSTALLED AS
<br />SPECIFIED AND DETAILED ON THE PLANS. RUBBERIZED MOULDINGS SHALL BE SPECIAL
<br />ORDERED WHEN REQUIRED FOR RADUIS AND/OR CURVED SURFACES AND ELEMENTS.
<br />FLASHING
<br />ALL PLUMBING PIPES SHALL BE FULLY INSULATED
<br />FLASHING MATERIAL SHALL BE MINIMUM 26 GAUGE GALVANIZED STEEL.
<br />FLASH AND COUNTER FLASH ALL ROOF TO WALL CONDITIONS. FLASH AND CAULK ALL
<br />VERTICAL TO HORIZONTAL JOINTS AND PLANE VARIATIATIONS. WOOD BEAMS,
<br />CORBELS, OUTLOOKERS, PROJECTIING THROUGH EXTERIOR WALLS, FLOORS, ROOF
<br />SURFACES AND/OR BALCONY, VERTICLE PIPES ETC. SHALL BE FLASHED AND
<br />CAULKED.
<br />GALVANIZED FLASHING SHALL BE CLEARED OF ALL FLUX AND SHOP PAINTED AS
<br />SPECIFIED UNDER PAINTING.
<br />EXTERIOR OPENINGS SHALL BE PROPERLY FLASHED WITH APPROVED WATER
<br />PROOFING MATERIALS.
<br />JOINTS AROUND DOORS, WINDOWS, MUDSILLS, WEEP SCREEDS, TRIM
<br />INTERSECTIONS AND ALL EXTERIOR OPENINGS SHALL BE COMPLETELY SEALED WITH
<br />THE HIGHEST GRADE OF NON-HARDENING, NON-STAINING ELASTIC COMPOUND
<br />CAULKING AFTER INSTALLATION OF SURROUNDING WORK IN A QUICK AND TIMELY
<br />MANNER (AS SOON AS POSSIBLE).
<br />EXTERIOR CEMENT PLASTER SHALL BE UNDERLAIN WITH A MINIMUM OF TWO LAYERS
<br />GRADE D PAPER AND MESH GALVANIZED SELF-FURRING METAL LATH 1.75 #/CU.FT. OR
<br />EQUIVALENT WITH 15# SATURATED BUILDING FELT AT PLYW OOD.
<br />WEEP SCREEDS SHALL BE INSTALLED AT THE FOUNDATION SILL LINE ON ALL
<br />EXTERIOR WALLS AND AS SHOWN ON DRAWINGS. WEEP SCREED SHALL HAVE A DRIP
<br />LINE FOR DRAINING TRAPPED WATER TO THE EXTERIOR OF THE BUILDING.
<br />FLASHIING, CORNER BEADS, SCREEDS, ETC., SHALL BE INSTALLED PROPERLY AS
<br />APPROPRIATE TO CONDITION AND AS SPECIFIED
<br />THERMAL AND MOISTURE PROTECTION
<br />ALL WORK SHALL COMPLY WITH TITLE 24 REQUIREMENTS
<br />INSULATION SHALL BE FIBERGLASS BATTS WITH KRAFT PAPER BACKING AND SHALL
<br />CONFORM TO FEDERAL SPECIFICATIONS.
<br />MINERAL FIBER INSULATION SHALL BE INSTALLED IN JOIST SPACES WHENEVER A
<br />PLUMBING PIPE OR DUCT PENETRATES A FLOOR-CEILING ASSEMBLY AND/OR WHEN
<br />THEY PASS THROUGH THE PLANE OF THE FLOOR-CEILING ASSEMBLY FROM A WALL.
<br />INSULATION SHALL EXTEND 12" PAST THE DUCTING AND/OR THE PIPING.
<br />THE CERTIFICATE OF COMPLIANCE SHALL BE SIGNED BY THE INSULATING SUB-
<br />CONTRACTOR AND GENERAL CONTRACTOR AND SHALL BE PROMINATELY POSTED ON
<br />THE CONSTRUCTION SITE.
<br />ALL INSULATION MATERIALS SHALL BE CERTIFIED BY THE MANUFACTURER AND
<br />COMPLY WITH THE CALIFORNIA QUALITY STANDARDS FOR INSULATING MATERIALS.
<br />R-3 INSULATION OR GREATER SHALL BE INSTALLED ON WATER INLET AND OUTLET
<br />PIPES FOR THE FIRST 5 FEET OF UNCONDITIONED SPACE U.N.O. (SEE TITLE 24
<br />CALCULATIONS)
<br />FINISH CARPENTRY
<br />WOOD TRIM SHALL BE IN SINGLE LENGTHS WHEN POSSIBLE
<br />MITER INTERIOR TRIM AT JOINTS
<br />KERF OR BACK CUT FLAT TRIM MEMBERS AS REQUIRED TO PREVENT WARPING.
<br />SET NAIL HEADS TO RECEIVE PUTTY.
<br />BASE MOULD SHALL MATCH EXISTING HOUSE
<br />DOOR AND WINDOW CASINGS AND DRYWALL BULLNOSE FINISH SHALL MATCH
<br />EXISTING OR BE PER SPECS.
<br />DOORS SHALL BE HUNG IN TRUE VERTICAL PLANE WITHOUT WARP OR WIND AND BE
<br />FITTED SO AS TO HAVE 1/16" CLEARANCE ABOVE THRESHOLDS WHERE DOORS OPEN
<br />INTO ROOMS. OTHERWISE, CLEARANCE SHALL BE 3/8" ABOVE THE FLOORS FOR
<br />INTERIOR DOORS. THE CLEARANCE AT THE HEAD AND JAMB SHALL BE 3/32". EXTERIOR
<br />DOORS SHALL BE FULLY WEATHERSTRIPPED.
<br />DOORKNOBS SHALL BE 36" ABOVE THE FINISHED FLOOR. LOCATION OF DOOR PULLS
<br />AND DEAD BOLTS SHALL BE LOCATED BY OWNERS. HANDICAPPED REQUIREMENTS
<br />SHALL APPLY AS REQUIRED IN HANDICAPPED SPACES AS REQUIRED BY ADA
<br />STANDARDS.
<br />PAINT
<br />PAINTER SHALL FURNISH MATERIALS, EQUIPMENT AND PERFORM ALL LABOR
<br />REQUIRED TO COMPLETE "PAINTING" WORK IN THE BEST METHOD AND STANDARDS
<br />OF THE TRADE - ALL INTERIOR AND EXTERIOR SURFACES, EXCLUDING THOSE ITEMS
<br />OR AREAS WITH FACTORY APPLIED FINISHES OR AS DIRECTED.
<br />THE CONTRACTOR SHALL INSURE EVEN APPLICATION PROPER CONSISTENCY DURING
<br />FAVORABLE WEATHER CONDITIONS.
<br />PROPER CLEANING AND SURFACE PREPARATION SHALL PRECEDE APPLICATION OF
<br />PRIMER COAT PLUS TWO FINISH COATS. PRIMER SHALL BE COLORED TO MATCH
<br />FINISH COLOR.
<br />WITH THE EXCEPTION OF TRIM AND TOUCH-UP WORK, PAINT SHALL BE BATCHED IN 5
<br />GALLON CONTAINERS PRIOR TO APPLICATION.
<br />ALL UNPAINTED SURFACES SHALL BE ADEQUATELY PROTECTED FROM PAINT OR
<br />DAMAGE.
<br />CONTRACTOR SHALL PROVIDE (6) SIX DIFFERENT INTERIOR COLORS THROUGHOUT
<br />THE ENTIRE PROJECT NEW AND OR EXISTING. PAINT AND/OR STAIN COLORS SHALL BE
<br />SPECIFIED BY DESIGNER.
<br />CONTRACTORS SHALL PROVIDE (2) TWO DIFFERENT EXTERIOR COLORS AT THE
<br />EXTERIOR, NEW AND EXISTING. PAINT AND STAIN COLORS SHALL BE SPECIFIED BY
<br />DESIGNER.
<br />CONTRACTORS SHALL PROVIDE OWNERS WITH (3) THREE COLOR SAMPLES OF EACH
<br />COLOR, APPROXIMATELY 3'-0" X 3'-0" COLOR SAMPLE, PRIOR TO WORK BEING
<br />PERFORMED.
<br />GRADING NOTES
<br />ALL FOOTINGS SHALL BE FOUNDED IN UNDISTURBED NATURAL SOIL PER CODE.
<br />IN THE EVENT EXCAVATIONS REVEAL UNFAVORABLE CONDITIONS, THE SERVICES OF A
<br />SOILS ENGINEER AND/OR GEOLOGIST MAY BE REQUIRED. CONTACT THE DESIGNER
<br />IMMEDIATELY.
<br />ALL CONCENTRATED DRAINAGE, INCLUDING ROOF WATER, SHALL BE CONDUCTED, VIA
<br />GRAVITTY TO THE STREET OR AN APPROVED LOCATION AT A 2% MINIMUM.
<br />ALL FILL OR BACKFILL SHALL BE COMPACTED BY MECHANICAL MEANS TO A MINIMUM
<br />90% RELATIVE COMPACTION AS DETERMINED BY ASTM METHOD D-1557. SUBDRAINS
<br />SHALL BE PROVIDED WHERE REQUIRED BY CODE.
<br />MISCELLANEOUS DOOR & WINDOW NOTES
<br />1. ALL GLASS WITHIN 18" OF THE FINISHED FLOOR SHALL BE FULL TEMPERED.
<br />TEMPERED GLASS REQ'S PERMANENT ETCHED LABEL EXC. SPANDREL GLASS
<br />REMOVABLE PAPER LABEL OK PER SECTION 2406.2 UBC 2001.
<br />2. ALL EGRESS OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL BE PROVIDED
<br />WITH A MINIMUM CLEAR OPENING OF 5.7 SQUARE FEET WITH THE MINIMUM NET
<br />WIDTH DIMENSION OF THE OPENING NOT LESS THAN 20". WHERE WINDOWS ARE
<br />PROVIDED AS A MEANS OF EGRESS OR RESCUE. THEY SHALL HAVE A FINISHED
<br />SILL HEIGHT OF NOT MORE THAN 44' ABOVE THE ADJACENT FINISHED FLOOR.
<br />3. ALL EXTERIOR DOORS AND WINDOWS SHALL COMPLY WITH THE BUILDING CODE
<br />SECURITY REQUIREMENTS AS ADOPTED BY THE LOCAL BUILDING DEPARTMENT
<br />AND SPECIFIED ELSEWHERE ON THIS SHEET.
<br />4. FRENCH DOORS AND WINDOWS USED AS A MEANS TO PROVIDE MINIMUM
<br />VENTILATION REQUIREMENTS SHALL BE OPEN-ABLE AND SHALL BE PROVIDED
<br />WITH SCREENS UNLESS NOTED OTHERWISE ON THE PLANS AND SPECIFICATIONS.
<br />ALL SUCH DOORS AND WINDOWS SHALL BE EQUIPPED WITH A MECHANICAL HOLD
<br />OPEN DEVICE.
<br />5. CONTRACTOR SHALL VERIFY EXACT ROUGH OPENING HEIGHT AND WIDTH OF ALL
<br />DOORS AND WINDOWS WITH DOOR AND WINDOW MANUFACTURER PRIOR TO
<br />START OF ROUGH FRAMING. ROUGH FRAMING SUB-CONTRACTOR IS
<br />RESPONSIBLE FOR PROVIDING ALL FRAMING NAILERS AND FILLERS AS SHOWN ON
<br />WINDOW AND DOOR DETAILS, MANUFACTURE'S STANDARD DETAILS AND AS MAY
<br />OTHERWISE BE REQUIRED FOR THE PROPER INSTALLATION OF ALL DOORS AND
<br />WINDOWS.
<br />6. ALL PANEL TYPE DOORS SHALL BE UNITS MANUFACTURED BY T.M. COBB CO.
<br />PANEL TYPE DOORS SHALL BE F-66 TYPE UNLESS NOTED OTHERWISE ON PLANS.
<br />7. ALL WINDOWS ARE BASED ON MILGARD ALUMINUM SERIES. FRENCH WINDOWS
<br />SHALL BE PROVIDED WITH FULLY TEMPERED GLASS. WINDOW UNITS SHALL BE
<br />PROVIDED WITH CLEAR DBL. GLAZING UNLESS NOTED OTHERWISE ON PLANS.
<br />PROVIDE FULLY TEMPERED GLASS AT CERTAIN WINDOWS AS SPECIFIED ON
<br />WINDOW SCHEDULE.
<br />8. WINDOW UNITS SHALL BE FULLY ASSEMBLED UNITS CONSTRUCTED PER
<br />SPECIFICATIONS
<br />9. WINDOW UNITS SHALL BE HINGED AS INDICATED ON EXTERIOR ELEVATIONS
<br />AND/OR PLANS.
<br />10. WINDOW UNITS SHALL BE DELIVERED TO THE JOB SITE WITH ALL HARDWARE
<br />SUCH AS OPERATORS, CRANK, OPERATOR ARM, LOCK, ETC.
<br />11. OWNER SHALL PROVIDE ALL NECESSARY HARDWARE NOT INCLUDED IN
<br />MANUFACTURED UNIT CONTRACTOR TO INSTALL ALL HARDWARE.
<br />12. ALL DOOR HARDWARE SHALL BE PROVIDED BY OWNER AND INSTALLED BY
<br />CONTRACTOR.
<br />13. ALL DOOR UNITS AND THEIR RESPECTIVE FRAMES SHALL BE PAINT GRADE.
<br />14. SAMPLE WINDOW TO BE APPROVED WITH SIGNED SHOP DRAWINGS BY OWNER/
<br />DESIGNER.
<br />15. UNLESS NOTED OTHERWISE, ALL EXTERIOR SWING DOORS TO BE SUPPLIED WITH
<br />MILL FINISHED EXTRUDED BRONZE PEMPO THRESHOLDS 114 B OR 145 B/ WITH 16
<br />oz. COPPER DRAIN PAN. THRESHOLDS TO BE POLISHED TO REMOVE MILL
<br />MARKINGS. PEMKO SPRING BRONZE WEATHER STRIPPING @ HEAD AND JAMBS.
<br />16. CAULK ALL INTERIOR/ EXTERIOR PLASTER JOINTS.
<br />17. ALL GLAZING ON DOORS AND WINDOWS TO BE DBL GLAZE 'LOW E' INSULATED
<br />GLASS.
<br />SECURITY NOTES (WHERE APPLICABLE):
<br />1. ALL EXTERIOR DOOR AND WINDOW OPENINGS ARE SECURITY OPENINGS, AND ALL
<br />NOTES SHALL APPLY.
<br />2. WOOD FLUSH-TYPE DOORS SHALL BE 1 3/4" THICK MINIMUM AND SHALL BE OF
<br />SOLID CORE CONSTRUCTION.
<br />3. HOLLOW CORE DOORS OR DOORS LESS THAN 1 3/4" IN THICKNESS SHALL BE
<br />COVERED ON THE INSIDE FACE WITH 16 OZ SHEET METAL ATTACHED WITH
<br />SCREWS AT 6" O/C AROUND THE PERIMETER, OR EQUIVALENT.
<br />4. GLAZED OPENINGS WITHIN 4" OF THE DOOR LOCK, WHEN THE DOOR IS IN THE
<br />CLOSED POSITION. SHALL BE FULLY TEMPERED GLASS OR APPROVED BURGLARY
<br />RESISTANT MATERIAL, OR SHALL BE PROTECTED BY METAL BARS, SCREENS OR
<br />GRILLES HAVING A MAXIMUM OPENING OF 2". THE PROVISIONS OF THIS SECTION
<br />SHALL NOT APPLY TO VIEW PORTS OR WINDOWS, WHICH DO NOT EXCEED 2" IN
<br />THEIR GREATEST DIMENSION.
<br />5. GLASS DOORS SHALL HAVE FULLY TEMPERED GLASS . TEMPERED GLASS REQ'S
<br />PERMANENT ETCHED LABEL EXC. SPANDREL GLASS REMOVABLE PAPER LABEL
<br />OK PER SECTION 2406.2 UBC 2001.
<br />6. DOORSTOPS OF IN-SWINGING DOORS SHALL BE OF ONE-PIECE CONSTRUCTION
<br />WITH THE JAMB, OR JOINED BY RABBET TO THE JAMB.
<br />7. ALL PIN-TYPE HINGES WHICH ARE ACCESSIBLE FROM OUTSIDE THE SECURED
<br />AREA WHEN THE DOOR IS CLOSED SHALL HAVE NON-REMOVABLE HINGE PINS. IN
<br />ADDITION THEY SHALL HAVE MINIMUM ¼" DIAMETER STEEL JAMB STUD WITH ¼"
<br />MINIMUM PROJECTION UNLESS THE HINGES ARE SHAPED TO PREVENT REMOVAL
<br />OF THE DOOR IF THE HINGE PINS ARE REMOVED.
<br />8. THE STRIKE PLATE FOR LATCHES AND THE HOLDING DEVICE FOR PROJECTION
<br />DEAD BOLTS IN WOOD CONSTRUCTION SHALL BE SECURED TO THE JAMB AND
<br />THE WALL FRAMING WITH SCREWS NOT LESS THAN 2 1/1" IN LENGTH.
<br />9. DEAD BOLTS SHALL HAVE HARDENED INSERTS; PROVIDE DEADLOCKING LATCH
<br />KEY OPERATED LOCKS ON THE EXTERIOR; LOCKS SHALL BE OPENABLE WITH OUT
<br />KEY, SPECIAL KNOWLEDGE OR SPECIAL EFFORT FROM THE INTERIOR.
<br />10. STRAIGHT DEAD BOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN
<br />EMBEDMENT OF NOT LESS THAN 5/8".
<br />11. A HOOK SHAPED OR AN EXPANDING-LUG DEAD BOLT SHALL HAVE A MINIMUM
<br />THROW OF 3/4".
<br />12. CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDERS LOCKS WHENEVER
<br />THE CYLINDER PROJECTS BEYOND THE FACE OF THE DOOR OR IS OTHERWISE
<br />ACCESSIBLE TO GRIPPING TOOLS.
<br />13. SLIDING GLASS DOORS AND WINDOWS SHALL BE EQUIPPED WITH LOCKING
<br />DEVICES AND SHALL BE SO CONSTRUCTED AND INSTALLED THAT THEY REMAIN
<br />INTACT AND ENGAGED WHEN SUBJECTED TO THE TESTS SPECIFIED IN SECTIONS
<br />91.6731 AND 91.6732.
<br />14. SLIDING GLASS DOORS AND WINDOWS SHALL BE PROVIDED WITH A DEVICE IN
<br />THE UPPER CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND
<br />REMOVING OF THE MOVING PANEL IN THE CLOSED OR PARTIALLY OPEN POSITION.
<br />15. SCREENS, BARRICADES, OR FENCES MADE OF MATERIAL WHICH PRECLUDES
<br />HUMAN CLIMBING SHALL BE PROVIDED AT EVERY PORTION OF EVERY ROOF,
<br />BALCONY, OR SIMILAR SURFACE WHICH IS WITHIN 8' OF A UTILITY POLE OR
<br />SIMILAR STRUCTURE.
<br />16. PROVIDE SAFETY GLAZING IN THE FOLLOWING LOCATIONS PER CODE. TEMPERED
<br />GLASS REQ'S PERMANENT ETCHED LABEL EXC. SPANDREL GLASS REMOVABLE
<br />PAPER LABEL OK PER CODE
<br />SLIDING OR SWINGING DOORS
<br />1. TUB AND/OR SHOWER ENCLOSURES AND GLAZING IN WALLS LESS THAN 60"
<br />ABOVE THE STANDING SURFACE OF TUBS OR SHOWERS.
<br />2. GLAZING WITHIN A 24" ARC OF A DOOR.
<br />CONCRETE
<br />NOTE: STRUCTURAL AND GEOLOGICAL NOTES AND DRAWING SHALL SUPERSEDE THE
<br />FOLLOWING
<br />WATER FOR CONCRETE MIXING SHALL BE FRESH, CLEAN AND SUITABLE FOR
<br />DOMESTIC PURPOSES.
<br />ALL EMBEDDED HARDWARE SHALL BE ICBO APPROVED. REINFORCEMENT, BOLTS,
<br />ANCHORS, SLEEVES, HOLD DOWNS ETC. SHALL BE FREE OF DIRT AND RUST PRIOR TO
<br />POURING OF CONCRETE.
<br />ALL SHOT PINS, REDHEADS AND MISCELLANEOUS HARDWARE SHALL BE ICBO
<br />APPROVED
<br />ALL WOOD SHALL BE A MINIMUM OF 6" ABOVE FINISHED GRADE
<br />SILL PLATES SHALL BE INSTALLED WITH FULL BEARING ON FOOTING WALL OR MORTAR
<br />BED. ALL WOOD CONTACTING CONCRETE SHALL BE PRESSURE TREATED.
<br />ALL WORK SHALL BE PLUMB, SQUARE ACCORDING TO THE PLANS, U.N.O.
<br />EXPOSED CONCRETE SURFACES SHALL HAVE A BROOM FINISH PROVIDING A NON-SLIP
<br />SURFACE U.N.O..
<br />ALL FOOTINGS SHALL SET ON FIRM NATURAL SOIL OR APPROVED COMPACTED FILL.
<br />REFER TO SOILS REPORT. LOAD BEARING FOOTINGS SHALL EXTEND BELOW NATURAL
<br />GRADE.
<br />REMOVE ALL WATER FROM TRENCHES AND FOUNDATION PRIOR TO POURING THE
<br />CONCRETE . FORMS SHALL BE WETTED.
<br />CONCRETE SHALL BE PLACED AS QUICKLY AS POSSIBLE TO PREVENT SEPARATION
<br />OF MATTER.
<br />CONCRETE SLABS SHALL BE 3 1/2" MINIMUM (U.N.O.) OVER 4" COURSE AGGREGATE
<br />BASE OR SAND BASE WITH MOISTURE BARRIER. PROVIDE "VISQUEEN" OR EQUIVALENT
<br />VAPOR BARRIER BETWEEN SLAB AND BASE. (VERIFY WITH STRUCTURAL PLANS AND
<br />NOTES )
<br />CONTRACTOR WILL REPLACE AND/OR REPAIR EXISTING DRIVEWAY, PATIOS ,
<br />WALKWAYS ETC. WHICH MAY BE DAMAGED DURING CONSTRUCTION.
<br />MASONRY
<br />STRUCTURAL NOTES AND DRAWING SHALL SUPERSEDE THE FOLLOWING:
<br />MASONRY SHALL BE SET IN RUNNING BOND PATTERN U.N.O.
<br />MASONRY SHALL MEET THE REQUIREMENTS FOR "HOLLOW LOAD BEARING CONCRETE
<br />MASONRY UNITS", ASTM C-90 AND COMPLY WITH LATEST EDITION OF THE UNIFORM
<br />BUILDING CODE.
<br />MORTAR AND GROUT SHALL BE OF FLUID CONSISTENCY AND RETEMPERING IS NOT
<br />ALLOWED.
<br />WALLS SHALL BE TRUE AND PLUMB. ALL JOINTS SHALL BE FULL FLUSH, BROOM FINISH.
<br />ALL CELLS CONTAINING REINFORCEMENT SHALL BE FILLED SOLID WITH GROUT. WHEN
<br />TOTAL GROUT POUR EXCEED 8 FEET IN HEIGHT, THE GROUT SHALL BE PLACED IN 4
<br />FOOT LIFTS AND SPECIAL INSPECTION SHALL BE PROVIDED AS REQUIRED.
<br />ALL MASONRY WORK SHALL BE LEFT CLEAN, FREE FROM EXCESS CEMENT AND
<br />EFFLORESCENCE AND IN A CONDITION SUITABLE FOR PAINTING, CEMENT PLASTER OR
<br />NO FINISH.
<br />METALS
<br />STRUCTURAL NOTES AND DRAWING SHALL SUPERSEDE THE FOLLOWING:
<br />CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR AND MATERIAL NECESSARY
<br />TO MAKE ALL FLASHING, VALLEYS, CHIMNEYS, RIDGES, SADDLES, CONDUCTORS AND
<br />ALL CONNECTIONS WATERTIGHT.
<br />ALL GALVANIZED STEEL SHALL BE 24 GAUGE MINIMUM U.N.O.
<br />ALL WORK SHALL BE SHOP PRE-FABRICATED WHEN POSSIBLE TO LIMIT SOLDERING
<br />JOINTS WHEN INSTALLED.
<br />ALL EXPOSED STEEL SHALL BE DOUBLE GALVANIZED.
<br />PROVIDE AND SET ALL IRON AND STEEL BEAMS, PIPE COLUMNS, ANCHORS AND
<br />MISCELLANEOUS ETC., AS SHOWN ON DRAWINGS.
<br />PROVIDE AND INSTALL ALL FRAMING HARDWARE REQUIRED FOR POSTS, BEAMS,
<br />RAFTERS, JOISTS AND OTHER FRAMING MEMBERS AS REQUIRED.
<br />PROVIDE AND INSTALL ALL ROOF AND DECK DRAINS AND INTERIOR DOWNSPOUTS AS
<br />MAY BE REQUIRED TO DRAIN ALL ROOF AND DECK WATER AND CONDUCT IT THROUGH
<br />ENCLOSED PIPING AND TO THE STREET.
<br />WOOD, PLASTIC & CARPENTRY
<br />STRUCTURAL NOTES AND DRAWING SHALL SUPERSEDE THE FOLLOWING:
<br />ALL WORK SHALL CONFORM TO GENERAL CONSTRUCTION REQUIREMENTS AND
<br />CONSTRUCTION PROVISIONS OF THE LATEST EDITION UBC. ALL WORK PERFORMED
<br />SHALL BE OF HIGH QUALITY WORKMANSHIP.
<br />DOOR FRAMES SHALL BE A SUITABLE DEPTH TO RECEIVE WALL FINISHED AS SHOWN
<br />ON DETAILS
<br />GALVANIZED NAILS SHALL BE USED FOR ALL EXTERIOR WOOD
<br />ALL FINISH WOOD, EXTERIOR AND INTERIOR SHALL BE NAILED WITH FINISH NAILS AND
<br />COUNTERSUNK.
<br />GLUE AND NAIL PLYWOOD SUB-FLOORING. (SEE STRUCTURAL PLANS AND DRAWINGS)
<br />ALL BOLTS AND NUTS BEARING ON WOOD SHALL HAVE WASHERS. (SEE STRUCTURAL
<br />PLANS AND DRAWINGS)
<br />CROSS BRIDGE OR SOLID BLOCK FLOOR JOISTS EVERY 8 FEET MAX. AND SOLID BLOCK
<br />AT SUPPORTS. BLOCK AT PLYWOOD SUB-FLOOR EDGES.
<br />WOOD TRIM SHALL BE IN SINGLE LENGTHS WHEN POSSIBLE.
<br />MITER INTERIOR TRIM AT JOINTS
<br />KERF OR BACK CUT FLAT TRIM MEMBERS AS REQUIRED TO PREVENT WARPING
<br />WORK SHALL BE INSTALLED AND SANDED AND NAIL HEADS SET TO RECEIVE PUTTY
<br />READY FOR PAINTING OR STAINING.
<br />WOOD CASINGS, BASE AND CROWN MOULDS, WINDOW STOOL AND APRONS, RUNNING
<br />TRIM AND CABINETS SHALL BE AS DETAILED AND SPECIFIED.
<br />QUARTER ROUND BASE SHOE AT WOOD FLOORS SHALL MATCH EXISTING
<br />FRAMING SHALL BE PERFORMED IN A PROFESSIONAL MANNER BY SKILLED
<br />CRAFTSPERSONS.
<br />ALL WOODWORK, BLOCKING, GROUNDS, ROUGH BUCKS AND MISC. FIRE BLOCKING
<br />SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS OR
<br />ORDINANCES.
<br />THE FRAMING SUB-CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND
<br />FITTING OF WOOD MEMBERS AS REQUIRED BY PLUMBING, ELECTRICAL, HEATING AND
<br />MECHANICAL CONTRACTORS.
<br />ALL GROUNDS AND/OR NAILERS SHALL BE PROVIDED AND INSTALLED AS REQUIRED
<br />FOR PLASTERING, DRYWALL WORK, WOOD BASES AND TRIMS AND SO FORTH AS
<br />REQUIRED. FURR AND BLOCK AS REQUIRED FOR ARCHITECTURAL FEATURES.
<br />FURNISH ALL ROUGH AND FINISH HARDWARE AS REQUIRED TO COMPLETE
<br />CONSTRUCTION OF THE JOB WITH HIGH QUALITY CRAFTSMANSHIP.
|