p r o j e c t d e s c r i p t i o n
<br />1.
<br />2.
<br />3.
<br />4.
<br />5.
<br />6.
<br />TENANT IMPROVEMENT OF SINGLE ACCOMMODATION RESTROOMS, CIRCULATION SPACES AS WELL AS
<br />DEPARTMENTAL RECEPTION AND WAITING AREAS BOTH FLOORS OF THIS 2 -STORY MEDICAL OFFICE BUILDING.
<br />THE WORK INCLUDES:.
<br />SELECTIVE DEMOLITION OF NON-BEARING PARTITIONS, FLOOR TILE, WALL TILE, PLUMBING FIXTURES, LIGHT
<br />FIXTURES, TOILET PARTITIONS AND LAMINATED WALL PANELS.
<br />PATCHING OF EXISTING PARTITIONS, CEILINGS, FL00R TILE, WALL TILE, NEW PLUMBING FIXTURES, AND NEW
<br />ADA COMPLIANT LAVATORY AND TOILET ACCESSORIES
<br />PLUMBING SCOPE TO INCLUDE REPLACEMENT OF EXISTING WATER CLOSETS, URINALS, AND LAVS.
<br />EXISTING PLUMBING FIXTURE COUNTS HAVE BEEN MAINTAINED.
<br />NO CHANGE IN USE TO THE EXISTING BUILDING.
<br />THIS BUILDING IS NOT AN OSHPD-3 BUILDING.
<br />v i c i n i t y m a p
<br />SITE PARKING
<br />E 4TH ST
<br />CA
<br />B
<br />R
<br />I
<br />L
<br />L
<br />O
<br />
<br />P
<br />A
<br />R
<br />K
<br />
<br />D
<br />R
<br />N
<br />G
<br />O
<br />L
<br />D
<br />E
<br />N
<br />
<br />C
<br />I
<br />R
<br />
<br />D
<br />R
<br />SITE
<br />p r o j e c t d a t a
<br />PROJECT ADDRESS:
<br />CONSTRUCTION TYPE:
<br />NUMBER OF STORIES:
<br />OCCUPANCY:
<br />BUILDING AREA:
<br />ASSESSOR'S PARCEL NUMBER:
<br />LEGAL DESCRIPTION:
<br />FIRE HAZARD SEVERITY ZONE:
<br />1900 EAST 4TH STREET
<br />SANTA ANA, CA 92710
<br />TYPE IIIB, FULLY SPRINKLERED
<br />2
<br />GROUP B - OFFICE
<br />BUILDING TOTAL AREA: 71,544 SF
<br />REFERENCE A001 AND A002
<br />PERMIT COSMETIC ONLY NO WORK FLOOR TOTAL
<br />FIRST FLOOR 1,269 SF 7,124 SF 26,898 SF 35,291 SF
<br />SECOND FLOOR 370 SF 5,301 SF 30,582 SF 36,253 SF
<br />_____________________________________________________________________________________
<br />TOTALS 1,639 SF 12,425 SF 57,480 SF 71,544SF
<br />PERMIT = TOTAL AREA OF T.I. SUBMITTED FOR PERMIT, REQUIRING DEMOLITION, NEW CONSTRUCTION, ELECTRICAL
<br />AND/OR PLUMBING WORK
<br />COSMETIC ONLY = TOTAL AREA OF T.I. FOR COSMETIC FINISHES ONLY
<br />NO WORK = TOTAL AREA NOT IN SCOPE (NO WORK)
<br />FLOOR TOTAL = TOTAL SQUARE FOOTAGE ON EACH FLOOR
<br />400-031-22
<br />P BK 98 P6 33 PAR 1
<br />NONE
<br />d e f e r r e d a p p r o v a l s
<br />1.NO PROPOSED DEFERRED APPROVALS
<br />a d d i t i v e a l t e r n a t e s
<br />PROVIDE PRICING FOR THE FOLLOWING ADDITIVE ALTERNATE SCOPE ITEMS AS REFERENCED ON THE
<br />DRAWINGS
<br />ADDITIVE ALTERNATE #1:
<br />NOT USED
<br />ADDITIVE ALTERNATE #2:
<br />DEMOLITION AND REMOVAL OF EXISTING WALL SCONCE LIGHT FIXTURES
<br />PROVISION AND INSTALLATION OF NEW WALL SCONCE LIGHT FIXTURES
<br />ADDITIVE ALTERNATE #3:
<br />DEMOLITION AND REMOVAL OF EXISTING WOOD PANEL AT WALLS AND SOFFITS.
<br />PREPARATION AND REPAIR OF EXISTING SUBSTRATE TO RECEIVE NEW FINISH.
<br />REMOVAL, REPAIR AND REINSTALLATION OF EXISTING DECORATIVE WOOD TRIM.
<br />PROVISION ON NEW PAINT FINISH ON DECORATIVE WOOD TRIM
<br />0 5'
<br />GRAPHIC SCALES:
<br />Issue Date
<br />1/16" = 1'-0"
<br />50'
<br />1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0"
<br />0 5'25'0 1'12'0 1'6'0 4'0 3'1'0 2'0 1'
<br />Chckd By
<br />Drwn By
<br />Scale
<br />Building ID:
<br />KP Proj. No.
<br />Permit No.
<br />Sheet
<br />SheetsOf
<br />Sheet Title
<br />Project
<br />Facility
<br />This document is the property of the Owner and is
<br />Project Architect Approval:
<br />Architect/Engineer Of Record:
<br />IF THIS SHEET IS NOT 30"x42" , IT IS
<br />A REDUCED PRINT - SCALE ACCORDINGLY
<br />National Facilities Services
<br />Post Office Box 12916
<br />Oakland California 94604
<br />not to be used without owner's written permission.
<br />Floor Lev:Section:
<br />Revisions
<br />By Appr.
<br />HGW Proj. No.
<br />©
<br />A
<br />R
<br />C
<br />H
<br />I
<br />T
<br />E
<br />C
<br />T
<br />S
<br />
<br />h
<br />a
<br />n
<br />n
<br />a
<br />
<br />g
<br />a
<br />b
<br />r
<br />i
<br />e
<br />l
<br />
<br />w
<br />e
<br />l
<br />l
<br />s
<br />,
<br />
<br />a
<br />l
<br />l
<br />
<br />r
<br />i
<br />g
<br />h
<br />t
<br />s
<br />
<br />r
<br />e
<br />s
<br />e
<br />r
<br />v
<br />e
<br />d
<br />.
<br />
<br />
<br />A
<br />n
<br />y
<br />
<br />u
<br />s
<br />e
<br /> w
<br />i
<br />t
<br />h
<br />o
<br />u
<br />t
<br />
<br />p
<br />e
<br />r
<br />m
<br />i
<br />s
<br />s
<br />i
<br />o
<br />n
<br />
<br />i
<br />s
<br />
<br />e
<br />x
<br />p
<br />r
<br />e
<br />s
<br />s
<br />l
<br />y
<br />
<br />p
<br />r
<br />o
<br />h
<br />i
<br />b
<br />i
<br />t
<br />e
<br />d
<br />.
<br />
<br />
<br />P
<br />l
<br />o
<br />t
<br />t
<br />e
<br />d
<br />1955 Bacon Street. San Diego, CA 92107
<br />Office 619 523 8487
<br />www.hgwarchitecture.com
<br />KAISER PERMANENTE
<br />BUILDINGS ON BRAND
<br /> 12" = 1'-0"
<br />1/
<br />2
<br />6
<br />/
<br />2
<br />0
<br />2
<br />6
<br />
<br />1
<br />0
<br />:
<br />1
<br />4
<br />:
<br />0
<br />2
<br />
<br />A
<br />M
<br />01/22/2026
<br />Checker
<br />Author
<br />CAP030945
<br />T001
<br />TITLE SHEET
<br />Santa Ana Medical Offices
<br />1900 E. 4th Street
<br />Santa Ana, CA, 92701
<br />PL
<br />A
<br />N
<br />
<br />C
<br />H
<br />E
<br />C
<br />K
<br />
<br />S
<br />U
<br />B
<br />M
<br />I
<br />T
<br />T
<br />A
<br />L
<br />2505
<br />EXTERIOR SIGNAGE - SANTA ANA
<br />i n d e x
<br />TITLE
<br />T001 TITLE SHEET
<br />T002 TYPICAL PROJECT NOTES, ABBREVIATIONS, SYMBOLS & LEGEND
<br />T100 CALGREEN - NONRESIDENTIAL MANDATORY MEASURES
<br />T101 CALGREEN - NONRESIDENTIAL MANDATORY MEASURES
<br />T150 ACCESSIBILITY NOTES
<br />T151 ACCESSIBILITY NOTES
<br />T152 ACCESSIBILITY NOTES
<br />T153 ACCESSIBILITY NOTES
<br />T154 ACCESSIBILITY DETAILS
<br />T201 1ST FLOOR EGRESS PLAN
<br />T300 SITE ACCESSIBILITY PLAN
<br />ARCHITECTURAL
<br />A001 1ST AND 2ND FLOOR INDEX PLAN
<br />A111 1ST FLOOR - AREA A1 - ENLARGED DEMO PLAN, NEW FLOOR PLAN AND FINISH PLAN
<br />A112 1ST FLOOR - AREA B1 - ENLARGED DEMO PLAN, NEW FLOOR PLAN AND FINISH PLAN
<br />A113 1ST FLOOR - AREA C1 - ENLARGED DEMO PLAN, NEW FLOOR PLAN AND FINISH PLAN
<br />A114 1ST FLOOR - AREA D1 - ENLARGED DEMO PLAN , NEW FLOOR PLAN AND FINISH PLAN
<br />A115 2ND FLOOR - AREA A2 - ENLARGED DEMO PLAN, NEW FLOOR PLAN AND FINISH PLAN
<br />A116 2ND FLOOR - AREA B2 - ENLARGED PLAN DEMO PLAN, NEW FLOOR PLAN AND FINISH PLAN
<br />A117 2ND FLOOR - AREA C2 - ENLARGED DEMO PLAN, NEW FLOOR PLAN AND FINISH PLAN
<br />A118 2ND FLOOR - AREA D2 - ENLARGED DEMO PLAN, NEW FLOOR PLAN AND FINISH PLAN
<br />A119 ENLARGED STAIR TILE & BASE LAYOUT - ST01 & ST02
<br />A121 1ST FLOOR - ENLARGED PLANS - RESTROOMS 1154 AND 1155
<br />A122 1ST FLOOR - ELEVATIONS - RESTROOMS 1154 AND 1155
<br />A123 1ST FLOOR - PLANS AND ELEVATIONS - RESTROOM 1518
<br />A124 1ST FLOOR - PLANS AND ELEVATIONS - RESTROOM 1622
<br />A125 1ST FLOOR - ENLARGED PLANS AND ELEVATIONS - RESTROOM 1713
<br />A126 2ND FLOOR - ENLARGED PLANS - RESTROOMS 2015 AND 2016
<br />A127 2ND FLOOR - ELEVATIONS - RESTROOMS 2015 - 2016 RESTROOMS
<br />A128 2ND FLOOR - ENLARGED PLANS AND ELEVATIONS - RESTROOMS 2636
<br />A161 1ST FLOOR - AREA A1 - ENLARGED DEMO AND NEW REFLECTED CEILING PLANS
<br />A162 1ST FLOOR - AREA B1 - ENLARGED DEMO AND NEW REFLECTED CEILING PLANS
<br />A163 1ST FLOOR - AREA C1 - ENLARGED DEMO AND NEW RELFECTED CEILING PLANS
<br />A164 1ST FLOOR - AREA D1 - ENLARGED DEMO AND NEW REFLECTED CEILING PLANS
<br />A165 2ND FLOOR - AREA A2 - ENLARGED DEMO AND NEW REFLECTED CEILING PLAN
<br />A166 2ND FLOOR - AREA B2 - ENLARGED DEMO AND NEW REFLECTED CEILING PLANS
<br />A167 2ND FLOOR - AREA C2 - ENLARGED DEMO AND NEW REFLECTED CEILING PLANS
<br />A168 2ND FLOOR - AREA D2 - ENLARGED DEMO AND NEW REFLECTED CEILING PLANS
<br />A700 FINISH SCHEDULE
<br />A722 1ST FLOOR - AREA B1 - ENLARGED DEMO & NEW FURNITURE PLAN
<br />A723 1ST FLOOR - AREA C1 - ENLARGED DEMO & NEW FURNITURE PLAN
<br />A724 1ST FLOOR - AREA D1 - ENLARGED DEMO & NEW FURNITURE PLAN
<br />A725 2ND FLOOR - AREA A2 - ENLARGED DEMO & NEW FURNITURE PLAN
<br />A726 2ND FLOOR - AREA B2 - ENLARGED DEMO & NEW FURNITURE PLAN
<br />A727 2ND FLOOR - AREA C2 - ENLARGED DEMO & NEW FURNITURE PLAN
<br />A728 2ND FLOOR - AREA D2 - ENLARGED DEMO & NEW FURNITURE PLAN
<br />A740 INTERIOR ELEVATIONS
<br />A741 INTERIOR ELEVATIONS
<br />A742 INTERIOR ELEVATIONS
<br />A743 INTERIOR ELEVATIONS
<br />A744 INTERIOR ELEVATIONS
<br />A745 INTERIOR ELEVATIONS
<br />A746 INTERIOR ELEVATIONS
<br />A747 INTERIOR ELEVATIONS
<br />A748 INTERIOR ELEVATIONS
<br />A749 INTERIOR ELEVATIONS
<br />A800 PARTITION DETAILS
<br />A801 TYPICAL PARTITION DETAILS
<br />A802 TYPICAL PARTITION DETAILS
<br />A820 TYPICAL CEILING DETAILS
<br />A821 TYPICAL CEILING DETAILS
<br />A840 TYPICAL INTERIOR DETAILS
<br />A841 TYPICAL INTERIOR DETAILS
<br />A850 CASEWORK DETAILS
<br />o w n e r / p e r m i t t e e :
<br />KAISER PERMANENTE
<br />74 NORTH PASADENA AVENUE, 8TH FLOOR
<br />PASADENA, CA 91103
<br />WORK: (626)372-4258
<br />AGNES C. HERRERA (Agnes.C.Herrera@kp.org)
<br />-
<br />-
<br />-
<br />a r c h i t e c t :
<br />HGW ARCHITECTURE
<br />1955 BACON STREET
<br />SAN DIEGO, CA 92107
<br />WORK: 619.523.8485
<br />RANDY HANNA (randy@hgwarchitecture.com)
<br />ERIC WENDLANDT (eric@hgwarchitecture.com)
<br />d i r e c t o r y
<br />f i r e d e p t . n o t e s
<br />ALL REQUIRED PERMITS MUST BE OBTAINED FROM FIRE PLAN CHECK BEFORE THE BUILDING IS OCCUPIED.
<br />STANDPIPE SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF CBC SEC. 905
<br />PLANS FOR AUTOMATIC FIRE SPRINKLER SYSTEMS & CLASS I STANDPIPES MUST BE SUBMITTED AND
<br />APPROVED BY FIRE PLAN CHECK BEFORE THIS EQUIPMENT IS INSTALLED.
<br />VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLER SYSTEMS, PUMPS, TANKS, WATER
<br />LEVELS AND TEMPERATURES, CRITICAL AIR PRESSURES AND WATERFLOW SWITCHES ON ALL SPRINKLER
<br />SYSTEMS SHALL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM CONTROL UNIT. (CBC SEC. 903.4)
<br />AN APPROVED AUDIBLE SPRINKLER FLOW ALARM SHALL BE PROVIDED ON THE EXTERIOR OF THE BUILDING
<br />IN AN APPROVED LOCATION PER (CBC SEC. 903.4.2). AN APPROVED AUDIBLE SPRINKLER FLOW ALARM TO
<br />ALERT THE OCCUPANTS SHALL BE INSTALLED IN THE INTERIORS IN A NORMALLY OCCUPIED LOCATION PER
<br />(CBC SEC. 904.3.4)
<br />PROVIDE TEMPORARY OR PERMANENT WATER SUPPLY FOR FIRE PROTECTION AS SOON AS COMBUSTIBLE
<br />MATERIALS ARRIVE ON SITE, AS REQUIRED AND APPROVED BY CORRESPONDANT FIRE DEPARTMENT
<br />FIRE PROTECTION, INCLUDING FIRE APPARATUS ACCESS ROADS AND WATER SUPPLIES FOR FIRE
<br />PROTECTION, SHALL BE INSTALLED AND MADE SERVICEABLE PRIOR TO AND DURING TIME OF
<br />CONSTRUCTION. (CFC 501.4)
<br />BUILDINGS UNDERGOING CONSTRUCTION ALTERATION OR DEMOLITION SHALL BE IN ACCORDANCE WITH CFC
<br />CHAPTER 33; CBC CHAPTER 33.
<br />ADDRESSES SHALL BE PROVIDED FOR ALL NEW AND EXISTING BUILDINGS IN A POSITION AS TO BE PLAINLY
<br />VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY.
<br />DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME RETARDANT CONDITION. (CODE REGS. TIT. 19,
<br />SEC. 3.08, 3.21, CFC 807)
<br />AT LEAST ONE FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2-A-10B:C SHALL BE PROVIDED WITHIN 75
<br />FEET MAXIMUM TRAVEL DISTANCE FOR EACH 6,000 S.F. OR PORTION THEREOF ON EACH FLOOR. (CFC 1002,
<br />UFC STANDARD 10-1, CAL. CODE REGS, TIT. 19, SEC. 3.29)
<br />AT LEAST ONE FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2-A-10B:C SHALL BE PROVIDED WITHIN 75
<br />FEET MAXIMUM TRAVEL DISTANCE PER CALIFORNIA CODE OF REGULATIONS, TITLE 19, DIVISION 1, SECTION
<br />568, TABLE 2. (CFC 906.3)
<br />COMPLETE PLANS AND SPECIFICATIONS FOR ALL FIRE ALARM SYSTEMS, FIRE EXTINGUISHING SYSTEMS,
<br />INCLUDING AUTOMATIC SPRINKLERS AND WET DRY STANDPIPES, HALON SYSTEMS AND OTHER SPECIAL
<br />TYPES OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS, BASEMENT PIPE INLETS AND OTHER FIRE PROTECTION
<br />SYSTEMS AND APPURTENANCES THERETO SHALL BE SUBMITTED TO FIRE AND SAFETY FOR REVIEW AND
<br />APPROVAL PRIOR TO INSTALLATION. (CFC 901.2)
<br />FIRE EXTINGUISHING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH CBC SEC. 906 AND COMPLY
<br />WITH STANDARDS 9-1 AND 9-2.
<br />INSTALLATION OF FIRE ALARM SYSTEMS SHALL BE IN ACCORDANCE WITH CFC SEC. 907 WITH NOT LESS
<br />THAN ONE STANDPIPE FOR USE DURING CONSTRUCTION INSTALLED IN ACCORDANCE WITH CBC SEC. 3314
<br />COMPLETE SITE SAFETY PLANS AND SPECIFICATIONS AT THE PROJECT SITE APPLICABLE THROUGHOUT ALL
<br />PHASES OF THE CONSTRUCTION, REPAIR, ALTERATION OR DEMOLITION WORK SHALL BE SUBMITTED TO FIRE
<br />AND LIFE SAFETY DEPARTMENT FOR REVIEW AND APPROVAL BUILDING PERMIT IS ISSUE CFC SEC. 3303
<br />FIRE HYDRANT LOCATIONS SHALL COMPLY WITH FIRE AND LIFE SAFETY FPB POLICY F-96-01 FOR ON SITE
<br />FIRE HYDRANTS
<br />FIRE HYDRANTS SHALL BE IDENTIFIED BY THE INSTALLATION OF REFLECTIVE MARKERS
<br />1.
<br />2.
<br />3.
<br />4.
<br />5.
<br />6.
<br />7.
<br />8.
<br />9.
<br />10.
<br />11.
<br />12.
<br />13.
<br />14.
<br />15.
<br />16.
<br />17.
<br />18.
<br />m e p e n g i n e e r :
<br />MA ENGINEERS
<br />5160 Carroll Canyon Road
<br />San Diego, CA 92121
<br />WORK: (858) 200-0030
<br />ERIC LEFTWICH (eleftwich@ma-engr.com)
<br />g o v e r n i n g c o d e s
<br />ALL WORK SHALL CONFORM TO THE CURRENT EDITIONS OF NATIONAL, STATE, AND LOCAL CODES, AND OTHER
<br />REGULATING AGENCIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK. ALL CONTRACTORS AND
<br />SUBCONTRACTORS PERFORMING GENERAL CONSTRUCTION, MECHANICAL, ELECTRICAL, PLUMBING, OR RELATED
<br />WORK, SHALL COMPLY WITH APPLICABLE SECTIONS OF THE CODES THAT HAVE JURISDICTION.
<br />APPLICABLE CODES:
<br />2022 CALIFORNIA BUILDING CODE (CBC) PART 1, PART 2, TITLE 24, CCR
<br />2022 CALIFORNIA PLUMBING CODE PART 5, TITLE 24, CCR
<br />2022 CALIFORNIA MECHANICAL CODE PART 4, TITLE 24, CCR
<br />2022 CALIFORNIA FIRE CODE PART 9, TITLE 24, CCR
<br />2022 NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
<br />2022 BUILDING STANDARDS ADMINISTRATIVE CODE PART 1, TITLE 24, CCR
<br />2022 CALIFORNIA ELECTRICAL CODE PART 3, TITLE 24, CCR
<br />2022 CALIFORNIA ENERGY CODE PART 6, TITLE 24, CCR
<br />2022 CALIFORNIA GREEN BUILDING STANDARDS (CALGreen), PART 11, TITLE 24 CCR
<br />2022 CALIFORNIA REFERENCED STANDARDS, PART 12, TITLE 24, CCR
<br />2022 CALIFORNIA EXISTING BUILDING CODE (CEBC)
<br />2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
<br />1900 EAST 4TH STREET1900 EAST 4TH STREET
<br />SANTA ANA, CA 92710SANTA ANA, CA 92710
<br />MECHANICAL
<br />M001 MECHANICAL LEGEND AND GENERAL NOTES
<br />M002 MECHANICAL SCHEDULES
<br />M112 MECHANICAL 1ST FLOOR-AREA B1-ENLARGED DEMO AND NEW FLOOR PLAN
<br />M114 MECHANICAL 1ST FLOOR-AREA D1-ENLARGED DEMO PLAN AND NEW FLOOR PLAN
<br />M125 MECHANICAL 1ST FLOOR-ENLARGED DEMO AND NEW FLOOR PLANS-RESTROOM 1713
<br />M500 MECHANICAL DETAILS
<br />PLUMBING
<br />P001 PLUMBING LEGEND AND GENERAL NOTES
<br />P002 PLUMBING SCHEDULES
<br />P111 PLUMBING 1ST FLOOR-AREA A1-ENLARGED DEMO PLAN
<br />P112 PLUMBING 1ST FLOOR-AREA B1-ENLARGED DEMO PLAN
<br />P113 PLUMBING 1ST FLOOR-AREA D1-ENLARGED DEMO PLAN
<br />P114 PLUMBING 2ND FLOOR-AREA A2-ENLARGED DEMO PLAN
<br />P118 PLUMBING 2ND FLOOR-AREA D2-ENLARGED DEMO PLAN
<br />P211 PLUMBINGH 1ST FLOOR-AREA A1-ENLARGED NEW WORK PLAN
<br />P212 PLUMBING 1ST FLOOR-AREA B1-ENLARGED NEW WORK PLAN
<br />P213 PLUMBING 1ST FLOOR-AREA D1-ENLARGED NEW WORK PLAN
<br />P214 PLUMBING 2ND FLOOR-AREA A2-ENLARGED NEW WORK PLAN
<br />P215 PLUMBING 2ND FLOOR-AREA D2-ENLARGED NEW WORK PLAN
<br />ELECTRICAL
<br />E000 ELECTRICAL TITLE SHEET
<br />E001 LUMINAIRE SCHEDULE
<br />E101 1ST FLOOR OVERALL PLAN
<br />E102 2ND FLOOR OVERALL PLAN
<br />ED202 1ST FLOOR DEMO POWER PLAN - AREA B1
<br />ED301 1ST FLOOR DEMO LIGHTING PLAN - AREA A1
<br />ED302 1ST FLOOR DEMO LIGHTING PLAN - AREA B1
<br />ED303 1ST FLOOR DEMO LIGHTING PLAN - AREA C1
<br />ED304 1ST FLOOR DEMO LIGHTING PLAN - AREA D1
<br />ED305 2ND FLOOR DEMO LIGHTING PLAN - AREA A2
<br />ED307 2ND FLOOR DEMO LIGHTING PLAN - AREA C2
<br />E201 1ST FLOOR POWER PLAN - AREA A1
<br />E202 1ST FLOOR POWER PLAN - AREA B1
<br />E203 1ST FLOOR POWER PLAN - AREA C1
<br />E204 1ST FLOOR POWER PLAN - AREA D1
<br />E205 2ND FLOOR POWER PLAN - AREA A2
<br />E208 2ND FLOOR POWER PLAN - AREA D2
<br />E301 1ST FLOOR LIGHTING PLAN - AREA A1
<br />E302 1ST FLOOR LIGHTING PLAN - AREA B1
<br />E303 1ST FLOOR LIGHTING PLAN - AREA C1
<br />E304 1ST FLOOR LIGHTING PLAN - AREA D1
<br />E305 2ND FLOOR LIGHTING PLAN - AREA A2
<br />E307 2ND FLOOR LIGHTING PLAN - AREA C2
<br />E401 ENLARGED PLANS
<br />E501 SINGLE LINE DIAGRAMS
<br />E601 PANEL SCHEDULES
<br />SIGNAGE & GRAPHICS
<br />SG100 INTERIOR SIGNAGE
<br />SG101 INTERIOR SIGNAGE
<br />SG102 INTERIOR SIGNAGE
<br />SG103 INTERIOR SIGNAGE
<br />SG111 1ST FLOOR -AREA A1 - SIGNAGE LOCAITON PLAN
<br />SG112 1ST FLOOR - AREA B1 - SIGNAGE LOCATION PLAN
<br />SG113 1ST FLOOR - AREA C1 - SIGNAGE LOCATION PLAN
<br />SG114 1ST FLOOR - AREA D1 - SIGNAGE LOCATION PLAN
<br />SG115 2ND FLOOR - AREA A2 - SIGNAGE LOCATION PLAN
<br />SG116 2ND FLOOR - AREA B2 - SIGNAGE LOCATION PLAN
<br />SG117 2ND FLOOR - AREA C2 - SIGNAGE LOCATION PLAN
<br />SG118 2ND FLOOR - AREA D2 -SIGNAGE LOCATION PLAN
<br />No.Revisions Date
<br />1 SD Set 06/05/2025
<br />2 DD Set 07/03/2025
<br />3 90% CD Set 08/14/2025
<br />4 Plan Check Submittal 09/19/2025
<br />KAISER PERMANENTE
<br />BUILDINGS ON BRAND
<br />SANTA ANA
<br />PL
<br />A
<br />N
<br />
<br />C
<br />H
<br />E
<br />C
<br />K
<br />
<br />R
<br />E
<br />S
<br />U
<br />B
<br />M
<br />I
<br />T
<br />T
<br />A
<br />L
<br />09-2027
|