Laserfiche WebLink
BUILDING AREA NOT <br />IN PROJECT SCOPE <br />BUILDING AREA NOT <br />IN PROJECT SCOPE <br />BUILDING AREA NOT <br />IN PROJECT SCOPE <br />GYP. BOARD CEILING - PAINTED <br />EXISTING METAL CEILING <br />TO REMAIN <br />BUILDING AREA NOT <br />IN PROJECT SCOPE <br />EXISTING GYP. BOARD CEILING - <br />PAINT PT-1 U.N.O. <br />ACRYLIC BLADE <br />EXISTING ACOUSTIC CEILING <br />TILES TO REMAIN IN PLACE <br />NEW ACOUSTIC CEILING TILES <br />WITHIN EXISTING CEILING GRID <br />NEW GYP. BOARD CEILING - <br />PAINT PT-1 U.N.O. <br />BUILDING AREA NOT <br />IN PROJECT SCOPE <br />BUILDING AREA NOT <br />IN PROJECT SCOPE <br />EXISTING ACOUSTIC CEILING <br />TILES TO REMAIN IN PLACE <br />EXISTING GYP. BOARD CEILING <br />EXISTING METAL CEILING <br />TO REMAIN <br />EXISTING P.LAM PANEL FINISH TO BE <br />REMOVED, PATCH & REPAIR, GYP. BD <br />SUBSTRATE AS REQ. TO RECIEVE NEW FINISH <br />f l o o r p l a n n o t e s <br />1. <br />2. <br />3. <br />4. <br />DIMENSIONS ARE TO FACE OF FINISHED WALL SURFACE, U.N.O. <br />ALL WALL-MOUNTED EQUIPMENT TO HAVE BACKING, U.N.O. REFERENCE TYPICAL BACKING DETAILS 16 & <br />17/A801. <br />PROVIDE CEMENTITIOUS BACKER BOARD (MANUFACTURER: HARDIEBACKER OR DENS ARMOUR PLUS <br />INTERIOR PANELS) AT WALL TILE LOCATIONS. SUBSTRATE VARIANCE TO BE 1/8” OR LESS IN 10’-0”. <br />COMPLY WITH TCNA’S “HANDBOOK FOR CERAMIN, GLASS, AND STONE TILE INSTALLATION” FOR TCNA <br />INSTALLATION METHODS SPECIFIED IN FINISH SCHEDULE. COMPLY WITH PARTS OF THE ANSI A 108 SERIES <br />“SPECIFICATIONS FOR INSTALLATION OF CERAMIC TILE” THAT ARE REFERENCED IN TCNA INSTALLATION <br />METHODS, SPECIFIED IN FINISH SCHEDULE, AND APPLY TO TYPES OF SETTING AND GROUTING MATERIALS <br />USED. <br />r e f l e c t e d c e i l i n g p l a n n o t e s <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />DIMENSIONS ARE TO FACE OF FINISHED WALL SURFACE, U.N.O. <br />PROVIDE BACKING AS REQUIRED FOR NEW LIGHT FIXTURES. <br />PAINT ALL GYP. BOARD CEILINGS AND SOFFITS PT-1, U.N.O. <br />REFER TO FINISH PLANS AND FINISH SCHEDULE FOR FURTHER CLARIFICATIONS AND INFORMATION. <br />CLEAN, PREP AND PAINT EXISTING PAINTED SHEET METAL MECHANICAL DEVICES (GRILLES, REGISTERS, <br />AND DIFFUSERS) AT ALL EXISTING LAY-IN CEILING GRID SYSTEMS TO RECIEVE NEW ACOUSTICAL TILE AND <br />EXISTING GYP. BD. CEILINGS SCHEDULED TO BE PAINT - COLOR TO BE PT-1 (SEMI-GLOSS FINISH). <br />CLEAN EXISTING ANODIZED ALUMINUM OR STAINLESS STEEL MECHANICAL DEVICES (GRILLES, REGISTERS, <br />AND DIFFUSER) – NO PAINT. <br />ALL EXISTING CEILING-MOUNTED DEVICES (SPRINKLERS, SPEAKERS, EXIT SIGNS, ALARM BELLS/STROBES, <br />SENSORS, DATA DEVICES, ETC.) TO REMAIN, U.N.O. <br />8.CLEAN PREP AND PAINT ALL EXISTING CEILING GRID SYSTEMS WHERE ACOUSTICAL TILES ARE BEING <br />REPLACED - COLOR TO BE PT-1F (FLAT FINISH). <br />f i n i s h p l a n n o t e s <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />1. <br />2. <br />3. <br />4. <br />5. <br />1. <br />2. <br />3. <br />4. <br />5. <br />1. <br />2. <br />3. <br />CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISHES FOR ARCHITECT’S APPROVAL PRIOR TO ORDERING <br />MATERIALS AND COMMENCEMENT OF WORK. <br />REFER TO ELEVATIONS, DETAILS, FINISH PLANS, AND FINISH SCHEDULE FOR FURTHER CLARIFICATION AND <br />INFORMATION. <br />INTERIOR FINISH MATERIALS APPLIED TO WALLS AND CEILINGS SHALL BE TESTED AS SPECIFIED IN CBC <br />SECTION 803. <br />ADHESIVES, SEALANTS AND CAULKS, PAINTS AND COATINGS, AND AEROSOL PAINTS AND COATINGS SHALL <br />MEET OR EXCEED THE STANDARDS OUTLINED IN CALGREEN SECTIONS 5.504.4.1, 5.504.4.2, 5.504.4.3 <br />RESPECTIVELY. VERIFICATION OF COMPLIANCE WITH THESE SECTIONS MUST BE PROVIDED AT THE TIME OF <br />INSPECTION. <br />PER CBC 803.13, ALL FINISHES SHALL BE MINIMUM CLASS ‘C’ RATED IN ROOMS AND ENCLOSED SPACES. <br />PROVIDE SCHLUTER METAL CORNER AND TOP TRIM AT WALLS TO RECEIVE NEW TILE FINISH. REFER TO <br />FINISH SCHEDULE FOR FURTHER INFORMATION. <br />F L O O R I N G N O T E SF L O O R I N G N O T E S <br />WHERE DOORS OCCUR, FLOORING MATERIAL TRANSITION SHALL BE CENTERED UNDERNEATH DOORS, <br />U.N.O. <br />CONTINUE ALL FLOORING MATERIALS BENEATH SINKS AND MILLWORK. <br />PATCH ALL AREAS WHERE THE FLOOR IN NOT LEVEL OR IS CRACKED PRIOR TO NEW FLOORING <br />INSTALLATION. <br />PREPARE EXISTING SURFACE AS REQUIRED TO PROVIDE SMOOTH AND LEVEL TRANSITION BETWEEN FINISH <br />FLOOR SURFACES. <br />REFERENCE FINISH PLANS FOR CLARIFICATION ON TILE START POINTS AND ALIGNMENT. <br />P A I N T / W A L L C O V E R I N G N O T E S P A I N T / W A L L C O V E R I N G N O T E S <br />SURFACES TO RECEIVE PAINT SHALL BE PROPERLY SEALED, SANDED, ETC. PRIOR TO APPLICATION. <br />PAINT SHALL BE APPLIED AS RECOMMENDED BY THE MANUFACTURER FOR GIVEN SPACE. PARTITIONS TO <br />BE PAINTED SHALL RECEIVE ONE COAT OF PRIMER PLUS A MINIMUM OF TWO COATS OF PAINT TO <br />COMPLETELY COVER. <br />ALL WALLS TO BE PAINTED PT-1, U.N.O. REFER TO FINISH SCHEDULE AND PLANS FOR ACCENT PAINT <br />COLORS AND LOCATIONS. <br />ALL HOLLOW METAL DOOR AND WINDOW FRAMES TO BE FPT-1, U.N.O. ANY ALUMINUM STOREFRONT <br />FRAMING TO REMAIN AS IS. <br />CONTRACTOR TO PROVIDE LEVEL 5 GYPSUM BOARD WALL FINISH WHERE WALLCOVERINGS OR WALL <br />GRAPHICS ARE TO BE APPLIED. REFER TO FINISH PLANS AND ELEVATIONS FOR LOCATIONS. <br />M I L L W O R K N O T E S M I L L W O R K N O T E S <br />BEFORE MANUFACTURING, THE MILLWORK CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND <br />SUBMIT SHOP DRAWINGS (FOR ALL MILLWORK) TO THE ARCHITECT FOR APPROVAL. <br />REFER TO INTERIOR ELEVATIONS FOR MILLWORK FINISHES. <br />COORDINATE MILLWORK WITH SPECIFIC PLUMBING FIXTURES WHERE APPLICABLE. <br />i n t e r i o r e l e v a t i o n s n o t e s <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />ALL WALL-MOUNTED EQUIPMENT AND ACCESSORIES TO HAVE BACKING, U.N.O. REFERENCE TYPICAL <br />BACKING DETAILS 16 & 17/A801. <br />PROVIDE BOX EXTENSION AT ALL POWER AND DATA OUTLET LOCATIONS WHERE WALL PANELING IS BEING <br />INSTALLED - REFERENCE DETAIL 20/A841 <br />REFERENCE TOILET ACCESSORIES SCHEDULE ON FLOOR PLANS FOR ADDITIONAL INFORMATION. <br />REFERENCE T150 FOR TYPICAL ADA MOUNTING HEIGHTS. <br />REFER TO FINISH PLANS AND FINISH SCHEDULE FOR FURTHER CLARIFICATION AND INFORMATION. <br />COMPLY WITH TCNA’S “HANDBOOK FOR CERAMIN, GLASS, AND STONE TILE INSTALLATION” FOR TCNA <br />INSTALLATION METHODS SPECIFIED IN FINISH SCHEDULE. COMPLY WITH PARTS OF THE ANSI A 108 SERIES <br />“SPECIFICATIONS FOR INSTALLATION OF CERAMIC TILE” THAT ARE REFERENCED IN TCNA INSTALLATION <br />METHODS, SPECIFIED IN FINISH SCHEDULE, AND APPLY TO TYPES OF SETTING AND GROUTING MATERIALS <br />USED. <br />REFERENCE SHEET A841 FOR REQUIRED FLOOR AND WALL TILE, END CAP, EDGE AND TRANSITION TRIM <br />DETAILS <br />REMOVE ALL SIGNAGE AND POSTINGS, U.N.O. PATCH AND REPAIR WALLS AS REQUIRED. <br />REFERENCE DEMOLITION GENERAL NOTES FOR FURTHER INFORMATION AND CLARIFICATION OF ITEMS TO BE <br />REMOVED. <br />d e m o l i t i o n n o t e s <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />14. <br />15. <br />16. <br />17. <br />18. <br />19. <br />20. <br />21. <br />22. <br />23. <br />24. <br />25. <br />26. <br />27. <br />28. <br />29. <br />30. <br />31. <br />DEMOLITION NOTES BELOW ARE APPLICABLE ONLY TO THAT SCOPE DEFINED WITHIN THE LIMIT OF WORK, <br />U.N.O. <br />CONTRACTOR TO NOTIFY OWNER AND ARCHITECT OF ANY DISCREPANCIES BETWEEN EXISTING-TO-REMAIN <br />ACTUAL CONDITIONS AND PLANS PRIOR TO DEMOLITION OF THAT PORTION OF THE BUILDING. <br />ALL DEMOLITION WORK SHALL AT ALL TIMES BE UNDER THE IMMEDIATE SUPERVISION OF A PERSON WITH <br />THE PROPER EXPERIENCE, TRAINING, AND AUTHORITY. <br />CONTRACTOR TO NOTIFY OWNER AND ARCHITECT OF ANY DRY ROT, MOLD, WATER DAMAGE, TERMITES, OR <br />OTHER FRAMING AND/OR STRUCTURAL DAMAGE TO EXISTING BUILDING. <br />ALL REMOVED BUILDING MATERIALS AND FIXTURES MAY BE SALVAGED AT THE OWNER’S DISCRETION. <br />VERIFY WITH OWNER PRIOR TO DEMOLITION WHAT IS TO BE REMOVED WITH CARE, SALVAGED, AND STORED <br />AT A LOCATION DESCRIBED BY OWNER. <br />REMOVE AND HAUL OFF SITE ALL MATERIALS TO BE DISPOSED OF. <br />DEMOLITION CONTRACTOR TO REDIRECT/CONNECT ANY ACTIVE EXISTING UTILITY, DRAINAGE, AND <br />SPRINKLER LINES WHICH ARE DISTURBED BY DEMOLITION. CAP ALL ABANDONDED LINES. <br />ALL RESTROOM ACCESSORIES TO BE REMOVED, U.N.O. CONFIRM ACCESSORIES TO BE SALVAGED FOR <br />REUSE WITH OWNER. <br />REFERENCE FINISH PLANS FOR NEW FINISHES. PREP EXISTING WALLS/FLOORS AS REQUIRED TO RECEIVE <br />NEW FINISHES. <br />REFERENCE FINISH SCHEDULE FOR FURTHER CLARIFICATION AND INFORMATION. <br />WHERE FLOORING IS TO BE REMOVED/REPLACED, THE EXISTING SURFACE SHALL BE MODIFIED AS REQUIRED <br />TO PROVIDE A SMOOTH TRANSITION BETWEEN ADJACENT FINISH FLOOR SURFACES. <br />PATCH AND REPAIR WALLS/FLOORS WHERE ITEMS ARE REMOVED. <br />REMOVE, SALVAGE, AND STORE ALL ARTWORK AT A LOCATION DESCRIBED BY THE OWNER. PATCH AND <br />REPAIR WALLS AS REQUIRED. <br />REMOVE, SALVAGE, AND STORE ALL FURNITURE INDICATED TO BE REMOVED AT A LOCATION DESCRIBED BY <br />THE OWNER. <br />REMOVE, SALVAGE, AND STORE ALL PLANTERS INDICATED TO BE REMOVED AT A LOCATION DESCRIBED BY <br />THE OWNER. <br />REMOVE, SALVAGE, AND STORE ALL BULLETIN BOARDS, BULLETIN BOARD CABINETS, WHITEBOARDS, AND <br />DISPLAY CABINETS AT A LOCATION DESCRIBED BY THE OWNER, U.N.O. PATCH AND REPAIR WALLS AS <br />REQUIRED. <br />REMOVE, SALVAGE, AND STORE ALL FILE HOLDERS, POSTINGS HOLDERS, PAMPHLET HOLDERS, AND <br />MAGAZINE RACKS AT A LOCATION DESCRIBED BY THE OWNER, U.N.O. PATCH AND REPAIR WALLS AS <br />REQUIRED. <br />REMOVE, SALVAGE, AND STORE ALL WALL-MOUNTED HAND SANITIZERS AT A LOCATION DESCRIBED BY THE <br />OWNER, U.N.O. PATCH AND REPAIR WALLS AS REQUIRED. <br />REMOVE ALL SIGNAGE AND POSTINGS, INCLUDING QUEUING STICKERS ON THE FLOOR, U.N.O. PATCH AND <br />REPAIR WALLS AS REQUIRED. <br />REMOVE ALL WALL CLOCKS, U.N.O. PATCH AND REPAIR WALLS AS REQUIRED. <br />EXISTING WALL-MOUNTED SECURITY MIRRORS TO REMAIN, U.N.O. <br />EXISTING WALL BASE TO REMAIN, U.N.O. <br />EXISTING CORNER GUARDS TO REMAIN, U.N.O. <br />REMOVE ALL WALL PROTECTION, U.N.O. PATCH AND REPAIR WALLS AS REQUIRED. <br />REMOVE ALL BRACKETS/WALL MOUNTS WHERE EXISTING TVS ARE INDICATED TO BE REMOVED - PATCH AND <br />REPAIR WALLS AS REQUIRED. EXISTING POWER/DATA RECEPTACLES TO REMAIN, U.N.O. <br />EXISTING SWITCHING DEVICES, POWER RECEPTACLES, DATA RECEPTACLES, THERMOSTATS, CARD <br />READERS, FIRE ALARM DEVICES, AND OTHER WALL MOUNTED DEVICES TO REMAIN, U.N.O. REMOVE COVER <br />PLATES/DEVICE FROM WALL SURFACE PRIOR TO PAINTING OR INSTALLATION OF WALLCOVERINGS OR WALL <br />GRAPHICS AND REINSTALL AFTERWARDS. <br />EXISTING WIFI ROUTERS AND OTHER I.T. DEVICES TO REMAIN, U.N.O. <br />ANY DEVICES INDICATED TO BE RELOCATED THAT REQUIRE DATA SHALL BE COORDINATED WITH THE <br />OWNER’S I.T. CONSULTANT. <br />EXISTING FIRE EXTINGUISHER CABINETS, EXTINGUISHERS, AND HOSE CABINETS TO REMAIN, U.N.O. <br />REFERENCE PLUMBING DRAWINGS FOR EXTENT OF PLUMBING DEMOLITION SCOPE. <br />REFERENCE ELECTRICAL DRAWINGS FOR EXTENT OF ELECTRICAL DEMOLITION SCOPE. <br />EXISTING WALLS <br />d e m o l i t i o n p l a n l e g e n d <br />LIMIT OF WORK <br />WALLS / ITEMS TO BE DEMOLISHED <br />EXISTING FLOORING TO BE <br />REPLACED <br />f l o o r p l a n l e g e n d <br />EXISTING WALLS <br />LIMIT OF WORK <br />NEW WALLS <br />EXISTING CORNER GUARD <br />TO REMAIN <br />NEW CORNER GUARD PER <br />SCHEDULE <br />(E)CG <br />CG <br />r e s t r o o m l e g e n d <br />ROOM NAME <br />?XX FINISH MATERIAL - REFERENCE <br />FINISH SCHEDULE <br />FLOORING TRANSITION - <br />REFERENCE DETAIL 05/A841 <br />XX ACCESSORY TYPE PER SCHEDULE <br />TILE START POINT <br />NAME <br />XXXX <br />1001 <br />XXXX <br />XXXX <br />ROOM NUMBER <br />WALL FINISH <br />BASE FINISH <br />FLOOR FINISH <br />S.P. <br />A WALL TYPE SYMBOL - <br />REFERENCE SHEET A800 <br />r e f l e c t e d c e i l i n g p l a n l e g e n d <br />EXISTING MECHANICAL SUPPY <br />EXISTING MECHANICAL RETURN <br />EXISTING LIGHT FIXTURE <br />NEW LIGHT FIXTURE <br />EXISTING LIGHT FIXTURE <br />TO REMAIN <br />EXISTING WALLS <br />LIMIT OF WORK <br />EXISTING FIRE DEVICE <br />EXISTING SECURITY CAMERA <br />EXISTING SPEAKER <br />EXISTING WI-FI DEVICE <br />(E)FD <br />(E)SC <br />(E)SP <br />(E)WF <br />EXISTING CALL LANTERN(E)CLEXISTING COVER PLATE(E)CP <br />EXISTING FIRE SPRINKLER(E)FS <br />EXISTING OCCUPANCY SENSOR(E)OC <br />NEW OCCUPANCY SENSOR(N)OC <br />NEW FIRE DEVICE(N)FD <br />NEW LIGHT FIXTURE <br />EXISTING LIGHT FIXTURE <br />EXISTING WALLS <br />f i n i s h p l a n l e g e n d <br />LIMIT OF WORK <br />NAME1001 <br />XXXX <br />XXXX <br />XXXX <br />BASE FINISH <br />FLOOR FINISH <br />WALL FINISH <br />ROOM NUMBER <br />ROOM NAME <br />?XX FINISH MATERIAL - REFERENCE <br />FINISH SCHEDULE <br />FLOORING TRANSITION <br />TILE START POINTS.P. <br />PATTERN/GRAIN DIRECTION <br />s y m b o l s <br />1 <br />000a <br />100M <br />24 <br />______01 <br />A200 <br />A740 <br />01A <br />? <br />W408a <br />01 <br />ASI <br /> <br />0 <br />2 <br />3 <br />01 <br />DOOR SYMBOL <br />WINDOW TYPE <br />FINISH SYMBOL <br />CASEWORK SYMBOL <br />BUILDING ELEVATION <br />INTERIOR ELEVATION(S) <br />KEYNOTE (SHEET SPECIFIC) <br />KEYNOTE (PROJECT-WIDE)0330 01 <br />REVISION <br />WALL TYPE <br />ROOM NAME <br />ROOM NUMBER <br />1 <br />01 <br />A300 <br />______01 <br />A300 <br />______ <br />______ <br />A500 <br />01 <br />01 <br />A300 <br />______ <br />BUILDING SECTIONS <br />WALL SECTIONS <br />DETAIL CUTS <br />GRID LINES <br />ELEVATION <br />01 drawing title <br />1/8" = 1'-0"DRAWING TITLE <br />1ST FLR. <br />+0'-0" <br />DETAIL CALLOUT <br />A <br />?CPT-01 <br />Aa <br />ALIGN <br />office <br />A000B 10000 SF <br />r e f l e c t e d c e i l i n g d e m o p l a n l e g e n d <br />EXISTING MECHANICAL SUPPY <br />EXISTING MECHANICAL RETURN <br />EXISTING WALLS <br />LIMIT OF WORK <br />WALLS / ITEMS TO BE DEMOLISHED <br />EXISTING ACOUSTIC CEILING <br />TILES TO BE REPLACED - CEILING <br />GRID TO REMAIN IN PLACE, U.N.O <br />EXISTING LIGHT FIXTURE <br />TO BE REPLACED <br />EXISTING LIGHT FIXTURE <br />TO REMAIN <br />EXISTING LIGHT FIXTURE <br />EXISTING SECURITY CAMERA <br />EXISTING SPEAKER <br />EXISTING WI-FI DEVICE <br />(E)FS <br />(E)SC <br />(E)SP <br />(E)WF <br />EXISTING CALL LANTERN <br />(E)CP <br />EXISTING FIRE SPRINKLER <br />EXISTING COVER PLATE <br />(E)CL(E)FD EXISTING FIRE DEVICE <br />(E)OC EXISTING OCCUPANCY SENSOR <br />(D)OC DEMO (E) OCCUPANCY SENSOR <br />DEMO (E) LIGHT FIXTURE <br />(D)FD DEMO (E) FIRE DEVICE <br />EXISTING LIGHT FIXTURE <br />TO BE REPLACED - REF. ADDITIVE ALTERNATES <br />NEW LIGHT FIXTURE <br />EXISTING LIGHT FIXTURE <br />TO REMAIN <br />EXISTING LIGHT FIXTURE <br />TO BE REPLACED <br />0 5' <br />GRAPHIC SCALES: <br />Issue Date <br />1/16" = 1'-0" <br />50' <br />1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" <br />0 5'25'0 1'12'0 1'6'0 4'0 3'1'0 2'0 1' <br />Chckd By <br />Drwn By <br />Scale <br />Building ID: <br />KP Proj. No. <br />Permit No. <br />Sheet <br />SheetsOf <br />Sheet Title <br />Project <br />Facility <br />This document is the property of the Owner and is <br />Project Architect Approval: <br />Architect/Engineer Of Record: <br />IF THIS SHEET IS NOT 30"x42" , IT IS <br />A REDUCED PRINT - SCALE ACCORDINGLY <br />National Facilities Services <br />Post Office Box 12916 <br />Oakland California 94604 <br />not to be used without owner's written permission. <br />Floor Lev:Section: <br />Revisions <br />By Appr. <br />HGW Proj. No. <br />© <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br /> <br />h <br />a <br />n <br />n <br />a <br /> <br />g <br />a <br />b <br />r <br />i <br />e <br />l <br /> <br />w <br />e <br />l <br />l <br />s <br />, <br /> <br />a <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br /> <br /> <br />A <br />n <br />y <br /> <br />u <br />s <br />e <br /> w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />i <br />s <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br />l <br />y <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br /> <br /> <br />P <br />l <br />o <br />t <br />t <br />e <br />d <br />1955 Bacon Street. San Diego, CA 92107 <br />Office 619 523 8487 <br />www.hgwarchitecture.com <br />KAISER PERMANENTE <br />BUILDINGS ON BRAND <br />As indicated <br />1/ <br />2 <br />1 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />5 <br />: <br />2 <br />3 <br />: <br />5 <br />0 <br /> <br />P <br />M <br />01/23/2026 <br />Checker <br />Author <br />CAP030945 <br />T002 <br />TYPICAL PROJECT NOTES, <br />ABBREVIATIONS, SYMBOLS & LEGEND <br />Santa Ana Medical Offices <br />1900 E. 4th Street <br />Santa Ana, CA, 92701 <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />R <br />E <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />2505 <br />SANTA ANA <br />ANCHOR BOLT <br />ASPHALTIC CONCRETE <br />OR AIR CONDITIONING <br />ACOUSTIC <br />ACCESS DOOR <br />ADDENDUM <br />ADJUSTABLE <br />ABOVE FINISH FLOOR <br />ALUMINUM <br />ALTERNATIVE <br />ANODIZED <br />ARCHITECTURAL <br />ASPHALT <br />AT <br />BOARD <br />BETWEEN <br />BOTTOM OF FOOTING <br />BUILDING <br />BLOCKING <br />BEAM <br />BOUNDARY NAIL <br />BEARING <br />BASEMENT <br />BUILT UP <br />CABINET <br />CENTERLINE <br />CERAMIC <br />CONTROL JOINT <br />CEILING <br />CONCRETE MASONRY <br />UNIT <br />COLUMN <br />CONCRETE <br />CONSTRUCTION <br />CONTINUOUS <br />COORDINATE <br />CORRIDOR <br />COUNTERSINK <br />CENTER <br />CHANNEL <br />PENNY (NAIL) <br />DOUBLE <br />DETAIL <br />DIAMETER <br />DIAGONAL <br />DIAPHRAGM <br />DRINKING FOUNTAIN <br />OR DOUGLAS FIR <br />DIMENSION <br />DEAD LOAD <br />DOWN <br />DOWNSPOUT <br />DRAWING <br />DOWELS <br />DRAWER <br />EAST <br />EACH <br />EXPANSION BOLT <br />EXPANSION JOINT <br />ELEVATOR <br />ELEVATION <br />ELECTRIC(AL) <br />EDGE NAIL <br />ENCLOSURE <br />EQUAL <br />EACH WAY <br />EXTERIOR <br />EXISTING <br />FLAT BAR <br />FLOOR DRAIN <br />FINISH FLOOR <br />FOUNDATION <br />FIRE EXTINGUISHER <br />FIRE EXTINGUISHER <br />CABINET <br />A.B. <br />A.C. <br />ACOUS. <br />A.D. <br />ADD. <br />ADJ. <br />A.F.F. <br />AL., ALUM. <br />ALT. <br />ANOD. <br />ARCH. <br />ASPH. <br />@ <br />BD., BO. <br />BET. <br />B.F. <br />BLDG. <br />BLKG. <br />BM. <br />B.N. <br />BRG. <br />BSMT. <br />B.U. <br />CAB. <br />CL <br />CER. <br />C.J. <br />CLG. <br />CMU <br />COL. <br />CONC. <br />CONSTR. <br />CONT. <br />COOR'D. <br />CORR. <br />CSK. <br />CTR. <br />C <br />d <br />DBL. <br />DET. <br />DIA., <br />DIAG. <br />DIAPH. <br />D.F. <br />DIM. <br />D.L. <br />DN. <br />D.S. <br />DWG. <br />DWLS. <br />DWR. <br />E. <br />EA. <br />E.B. <br />E.J. <br />EL. <br />ELEV. <br />ELEC. <br />E.N. <br />ENC. <br />EQ. <br />E.W. <br />EXT. <br />EXST. <br />F.B. <br />F.D. <br />F.F. <br />FDN. <br />F.E. <br />F.E.C. <br />FINISH FLOOR ELEVATION <br />FINISH <br />FLOOR <br />FLUORESCENT <br />FIELD NAIL <br />FACE OF (ITEM) <br />FACE OF BRICK <br />FACE OF CONCRETE <br />FACE OF FINISH <br />FACE OF MASONRY <br />FACE OF STUD <br />FIREPROOFING <br />FOOT OR FEET <br />FLOOR SINK <br />FIELD VERIFY <br />GAUGE <br />GALVANIZED <br />GALVANIZED IRON <br />GLASS <br />GLUE LAMINATED BEAM <br />GYPSUM BOARD <br />HOSE BIBB <br />HOLLOW CORE <br />HEADER <br />HARDWARE <br />HANGER <br />HOLLOW METAL <br />HORIZONTAL <br />HEIGHT <br />HEATING, VENTILATING <br />& AIR CONDITIONING <br />HOT WATER <br />INSIDE DIAMETER <br />INCH <br />INCLUDED <br />INVERT ELEVATION <br />INSULATION <br />INTERIOR <br />JANITOR <br />JOIST <br />JOINT <br />KITCHEN <br />LAMINATED <br />LAG BOLTS <br />LIVE LOAD <br />LONG LEG HORIZONTAL <br />LONG LEG VERTICAL <br />LONGITUDINAL <br />LOW POINT <br />LIGHT WEIGHT CONCRETE <br />MASONRY <br />MATERIAL <br />MAXIMUM <br />MECHANICAL <br />MEMBRANE <br />METAL <br />MANUFACTURER <br />MINIMUM <br />MISCELLANEOUS <br />NORTH <br />NOT IN CONTRACT <br />NUMBER <br />NOT TO SCALE <br />NON-COMBUSTIBLE <br />NON-RATED <br />OVER <br />ON CENTER <br />OUTSIDE DIAMETER <br />OVERFLOW OR <br />OUTSIDE FACE <br />OPPOSITE HAND <br />F.F.E. <br />FIN. <br />FLR. <br />FLUOR. <br />F.N. <br />F.O. <br />F.O.B. <br />F.O.C. <br />F.O.F. <br />F.O.M. <br />F.O.S. <br />F.P. <br />FT. <br />F.S. <br />F.V. <br />GA. <br />GALV. <br />G.I. <br />GL. <br />GLB. <br />GYP. BD. <br />H.B. <br />H.C. <br />HDR. <br />HDWR. <br />HGR. <br />H.M. <br />HORIZ. <br />HT. <br />H.V.A.C. <br />H.W. <br />I.D. <br />IN. <br />INCL. <br />I.E. <br />INSUL. <br />INT. <br />JAN. <br />JST. <br />JT. <br />KIT. <br />LAM. <br />L.G. <br />L.L. <br />LLH <br />LLV <br />LONGIT. <br />L.P. <br />L.W.C. <br />MAS. <br />MAT'L. <br />MAX. <br />MECH. <br />MEMB. <br />MET., MTL. <br />MFR. <br />MIN. <br />MISC. <br />N. <br />N.I.C. <br />NO. <br />N.T.S. <br />NC <br />NR <br />O/ <br />O.C. <br />O.D. <br />O.F. <br />O.H. <br />OPENING <br />OPPOSITE <br />OVERHEAD <br />PROPERTY LINE <br />PLYWOOD <br />POUNDS PER SQ. FOOT <br />POUNDS PER SQ. INCH <br />PRESSURE TREATED <br />PAINTED <br />POST TENSIONED SLAB <br />PERIMETER <br />PERPENDICULAR <br />PLASTER <br />PLASTIC <br />RISE <br />ROOF DRAIN <br />REFERENCE <br />REINFORCING <br />RESILIENT <br />RETAIN(ING) <br />REQUIRE(D) <br />REQUIREMENTS <br />ROOM <br />ROUGH OPENING <br />RADIUS POINT <br />SOUTH <br />SOLID CORE <br />SCHEDULE <br />SHEET <br />SQUARE FEET <br />SIMILAR <br />STAND PIPE <br />SPACING <br />SPECIFICATION <br />SQUARE <br />STAINLESS STEEL <br />STAGGERED <br />STANDARD <br />STIFFENED <br />STRUCTURAL <br />STEEL <br />TREAD <br />TOP OF CURB OR <br />TOP OF CONCRETE <br />TONGUE AND GROOVE <br />THRESHOLD <br />TOOLED JOINT <br />TOENAIL <br />TOP OF (ITEM) <br />TOP OF FOOTING <br />TOP OF SLAB <br />TOP OF WALL <br />TRANSVERSE <br />TYPICAL <br />UNLESS NOTED <br />OTHERWISE <br />UNIFORM BUILDING CODE <br />VAPOR BARRIER <br />VENTILATION <br />VERTICAL <br />WEST <br />WITH <br />WOOD <br />WATER HEATER <br />WITHOUT <br />WATERPROOF(ING) <br />WEAKENED PLANE JOINT <br />WATER RESISTANT <br />WEIGHT <br />WELDED WIRE FABRIC <br />YARD <br />OPG. <br />OPP. <br />OHD. <br />PL <br />PWD. <br />P.S.F. <br />P.S.I. <br />P.T. <br />PTD. <br />P.T.S. <br />PERIM. <br />, PERP. <br />PLAS. <br />PLAST. <br />R. <br />R.D. <br />REF. <br />REINF. <br />RESIL. <br />RET. <br />REQ.('D) <br />REQMTS. <br />RM. <br />R.O. <br />R.P. <br />S. <br />S.C. <br />SCHED. <br />SHT. <br />S.F. <br />SIM. <br />S.P. <br />SP'G. <br />SPEC. <br />SQ. <br />S.S. <br />STAGG. <br />STD. <br />STIFF. <br />STR. OR <br />STRUCT. <br />ST. <br />T. <br />T.C. <br />T & G <br />THR. <br />T.J. <br />T.N. <br />T.O. <br />T.O.F. <br />T.O.S. <br />T.O.W. <br />TRANS. <br />TYP. <br />U.N.O. <br />U.B.C. <br />V.B. <br />VENT. <br />VERT. <br />W. <br />W/ <br />WD. <br />W.H. <br />W/O <br />WP. <br />W.P.J. <br />W.R. <br />WT. <br />W.W.F. <br />YD. <br />a b b r e v i a t i o n s <br />No.Revisions Date <br />1 SD Set 06/05/2025 <br />2 DD Set 07/03/2025 <br />3 90% CD Set 08/14/2025 <br />4 Plan Check Submittal 09/19/2025 <br />09-2027