MA MASONRY <br />MA-1)LOAD BEARING, NON-LOAD BEARING, AND BACKUP WALL CONCRETE MASONRY <br />CONSTRUCTION SHALL CONFORM TO THE FOLLOWING MATERIAL STANDARDS: <br />CONCRETE BLOCK: ASTM C90, LIGHTWEIGHT (105 PCF) (MINIMUM 28 <br />DAY COMPRESSIVE STRENGTH 1900 PSI FOR S OR <br />M OR 2150 PSI FOR N) <br />MORTAR: ASTM C270, TYPE S, M OR N PORTLAND CEMENT / <br />LIME ONLY BY PROPORTION <br />MORTAR USAGE <br />(UON ON DRAWINGS): USE TYPE S OR M MORTAR WHEN MASONRY IS IN <br />DIRECT CONTACT WITH SOIL; USE TYPE S MORTAR <br />FOR ALL EXTERIOR AND INTERIOR LOAD-BEARING <br />WALLS; USE TYPE N MORTAR FOR ALL EXTERIOR <br />AND INTERIOR NON-LOAD-BEARING WALLS <br />GROUT: ASTM C476 BY PROPORTION (MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH 2000 PSI) <br />REINFORCEMENT: ASTM A615, GRADE 60 <br />JOINT REINFORCEMENT: ASTM A1064, TRUSS OR LADDER TYPE <br />EXTERIOR JT REINF: GALVANIZE PER ASTM A153 <br />INTERIOR JT REINF: <br />TYPICAL GALVANIZE PER ASTM A641 <br />RELATIVE HUMIDITY >75% GALVANIZE PER ASTM A153 <br />ADHESIVE ANCHORS: HILTI HIT-HY 70 <br />MA-2)THE MINIMUM COMPRESSIVE STRENGTH OF THE MASONRY (f' m) SHALL BE 1,800 <br />PSI UON, VERIFIED BY THE UNIT STRENGTH METHOD IN ACCORDANCE WITH THE ABOVE <br />REFERENCED SPECIFICATIONS. <br />MA-3)CALCIUM CHLORIDE SHALL NOT BE USED IN MORTAR OR GROUT. <br />MA-4)PROVIDE FULL FACE SHELL MORTAR COVERAGE ON MASONRY UNIT HORIZONTAL <br />AND VERTICAL (BED AND HEAD) FACE SHELL JOINTS. <br />MA-5)PROVIDE FULL MORTAR COVERAGE ON WEBS AROUND ALL GROUTED CELLS. <br />MA-6)LAY MASONRY UNITS IN RUNNING BOND UON WITH UNITS DESIGNED TO ALIGN <br />WITH WEBS IN EACH COURSE. <br />MA-7)REFER TO PLANS AND DETAILS FOR BONDED JOINT REQUIREMENTS AT WALL <br />CORNERS AND INTERSECTIONS. WHERE INDICATED ON DRAWINGS, INTERLOCK WALLS <br />WITH METAL TIES, ANCHORS OR PREFABRICATED JOINT REINFORCEMENT UON ON <br />DRAWINGS OR IN SPECIFICATIONS. <br />MA-8)GROUT SOLID CELLS WITH REINFORCEMENT. GROUT SOLID CELLS IN BELOW <br />GRADE CONSTRUCTION WHERE MASONRY IS IN CONTACT WITH SOIL. <br />MA-9)GROUT MINIMUM OF ONE (1) CELL WITH REINFORCEMENT AT EACH SIDE OF ALL <br />OPENINGS. SEE DRAWINGS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS. <br />MA-10)WHERE STRAP ANCHORS ARE REQUIRED BY DRAWINGS OR SPECIFICATIONS, <br />LOCATE THEM AT DIFFERENT BED JOINTS THAN THOSE RECEIVING HORIZONTAL JOINT <br />REINFORCEMENT. <br />MA-11)WHERE REQUIRED, LAP HORIZONTAL JOINT REINFORCEMENT BY AT LEAST 6 <br />INCHES. <br />MA-12)PLACE GROUT BY THE LOW-LIFT METHOD. MAXIMUM GROUT POUR SHALL BE 4 <br />FEET. <br />SS STRUCTURAL STEEL <br />SS-1)STEEL MATERIALS SHALL CONFORM TO THE FOLLOWING MINIMUM REQUIREMENTS <br />UNLESS OTHERWISE NOTED ON THE CONTRACT DOCUMENTS: <br />ROLLED SHAPES AND CHANNELS: ASTM A572 OR A992, MIN YIELD STRENGTH 50 KSI <br />ANGLES FOR TRUSSES AND BRACES: ASTM A572 OR A529, MIN YIELD STRENGTH 50 KSI <br />MISCELLANEOUS ANGLES: ASTM A572 OR A529, MIN YIELD STRENGTH 50 KSI <br />HOLLOW STRUCTURAL SECTIONS: GRADE C, MIN YIELD STRENGTH 46 KSI FOR <br />ROUND AND 50 KSI FOR RECTANGULAR HSS <br />SEAMLESS PIPE: ASTM A53 GRADE B, TYPE S, MIN YIELD STRENGTH <br />35 KSI. <br />PLATES ASTM A572 OR A529, MIN YIELD STRENGTH 50 KSI <br />SS-2)CONNECTION MATERIAL SHALL CONFORM TO THE FOLLOWING MINIMUM <br />REQUIREMENTS OR AS NEEDED FOR CONNECTION DESIGN: <br />ANGLES: ASTM A572 OR A529, MIN YIELD STRENGTH 50 KSI <br />WTs: ASTM A992 <br />PLATES: ASTM A36, MIN YIELD STRENGTH 36 KSI OR <br />ASTM A572 OR A529, MINIMUM YIELD STRENGTH 50 KSI <br />BOLTS: ASTM A325 OR A490 <br />NUTS: ASTM A563 <br />WASHERS: ASTM F436 <br />ANCHOR RODS: ASTM F1554 GRADE 55 WITH WELDABILITY SUPPLEMENT S1 <br />HEADED STUDS: ASTM A 108, GRADE 1010 THROUGH 1020 HEADED STUD <br />TYPE, COLD-FINISHED CARBON STEEL, AWS D1.1, TYPE B. <br />3/4” DIAMETER UON <br />WELD ELECTRODES: E70XX <br />SS-3)WHERE NO CAMBER IS INDICATED, FABRICATE BEAMS SO THAT ANY NATURAL <br />CAMBER IS UPWARD AFTER ERECTION. <br />SS-4)SPLICES SHALL BE ALLOWED ONLY AT LOCATIONS SPECIFICALLY INDICATED ON THE <br />STRUCTURAL DRAWINGS UNLESS APPROVED OTHERWISE BY THE SER IN WRITING. <br />SS-5)FOR STEEL MEMBERS AND EMBEDMENTS EXPOSED TO WEATHER, PROVIDE HOT- <br />DIPPED GALVANIZED FINISH OR APPROVED ZINC RICH EXTERIOR COATING SYSTEM. <br />SS-6)PROVIDE HOLES IN ALL STEEL AS REQUIRED TO PREVENT ANY ACCUMULATION OF <br />WATER. ALL PENETRATIONS THROUGH MAIN MEMBERS SHALL NOT EXCEED 1 1/8" DIA. <br />AND SHALL BE GROUND SMOOTH. THESE DRAINS MUST BE KEPT CLEAN AND OPEN. <br />SS-7)SHOW ALL COPES, HOLES, OPENINGS AND MODIFICATIONS REQUIRED IN <br />STRUCTURAL STEEL MEMBERS FOR ERECTION OR THE WORK OF OTHER TRADES ON THE <br />SHOP DRAWINGS FOR APPROVAL BY THE DESIGN PROFESSIONALS. <br />SS-8)FIELD MODIFICATION OF STRUCTURAL STEEL IS PROHIBITED WITHOUT PRIOR <br />WRITTEN APPROVAL OF THE DESIGN PROFESSIONALS. <br />SS-9)MINIMUM CHARPY V-NOTCH IMPACT TESTING VALUES FOR STEEL USING COMPLETE <br />JOINT PENETRATION GROOVE WELDS THAT FUSE THROUGH THE THICKNESS OF THE <br />FLANGE OR WEB AND STEEL DESIGNATED AS PART OF THE SEISMIC FORCE RESISTING <br />SYSTEM USING WELDED OR BOLTED CONNECTIONS SHALL BE AS FOLLOWS: <br />A. ASTM A6/A6M HOT-ROLLED SHAPES WITH A FLANGE THICKNESS EXCEEDING 2 <br />INCHES: 20 FT-LB @ 70 DEG F. THIS TESTING TO BE IN ACCORDANCE WITH <br />SUPPLEMENTARY REQUIREMENT S30, CHARPY V-NOTCH IMPACT TEST FOR <br />STRUCTURAL SHAPES – ALTERNATE CORE LOCATION. <br />B. BUILT-UP HEAVY SECTIONS WITH PLATES EXCEEDING 2 INCHES IN THICKNESS: 20 FT- <br />LB @ 70 DEG F. THIS TESTING TO BE PERFORMED AT FREQUENCY P AND IN <br />ACCORDANCE WITH ASTM A673/A673M. <br />C. REGARDLESS OF THICKNESS, ALL TRUSSES, LATERAL SYSTEM MEMBERS (INCLUDING <br />COLUMNS, WIND GIRDERS, BRACES, ETC.): 20 FT-LB @ 70 DEG F. <br />D. STEEL EXPOSED TO TEMPERATURES IN SERVICE BELOW 50 DEG F: 20 FT-LB @ LAST + <br />70 DEG F, 40 DEG F MAX. <br />E. REGARDLESS OF THICKNESS, ALL TRUSSES, LATERAL SYSTEM MEMBERS (INCLUDING <br />COLUMNS, WIND GIRDERS, BRACES, ETC) EXPOSED TO TEMPERATURES IN SERVICE <br />BELOW 50 DEG F: 30 FT-LB @ LAST + 70 DEG F, 40 DEG F MAX. <br />F. WELD METAL: 20 FT-LB @ 0 DEG F AND 40 FT-LB @ 70 DEG F. <br />G. WELD METAL EXPOSED TO TEMPERATURES IN SERVICE BELOW 50 DEG F: 20 FT- LB <br />@ 0 DEG F AND 40 FT-LB @ LAST + 20 DEG F, 40 DEG F MAX. <br />SS-10)STRUCTURAL STEEL MEMBERS AND CONNECTIONS THAT ARE INDICATED AS PART <br />OF THE SEISMIC FORCE RESISTING SYSTEM SHALL COMPLY WITH SPECIFICATION <br />SECTION 051210. <br />SC STRUCTURAL STEEL CONNECTIONS <br />SC-1)ALL STEEL DETAILS AND CONNECTIONS SHALL BE IN ACCORDANCE WITH THE <br />REQUIREMENTS OF "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS”, AISC-LOAD <br />AND RESISTANCE FACTOR DESIGN. <br />SC-2)ALL CONNECTIONS INDICATED ON STRUCTURAL DRAWINGS HAVE BEEN <br />COMPLETELY DESIGNED. <br />SC-3)DETAILS INDICATED ON DRAWINGS DO NOT SHOW ERECTION AIDS. PROVIDE <br />ERECTION AIDS AS REQUIRED AND REMOVE THEM AFTER WORK IS COMPLETE. <br />SC-4) ALTERNATE CONNECTIONS TO THOSE SHOWN ON DRAWINGS WILL BE <br />CONSIDERED AS A SUBSTITUTION REQUEST. SEE PROJECT SPECIFICATIONS. <br />SC-5)FOR CONNECTION DETAILING, SET CONNECTION WORK POINT AT INTERSECTION <br />OF MEMBER CENTERLINES, UON. <br />SC-6)CONNECTION DESIGN FORCES INDICATED ON THE DRAWINGS ARE FACTORED <br />UON. <br />SC-7)USE NO MORE THAN TWO BOLT DIAMETERS, ALL BOLTS OF THE SAME DIAMETER <br />SHALL BE OF THE SAME GRADE, SKIP ONE SIZE BETWEEN DIAMETERS. BOLTS TO BE A <br />MINIMUM OF 3/4-INCH DIAMETER GRADE A325. <br />SC-8)BEAM CONNECTION DESIGN NOTES: <br />EXCEPT WHERE “SNUG TIGHT” INSTALLATION IS SPECIFICALLY PERMITTED ON <br />DRAWINGS OR “SLIP CRITICAL” DETAILING IS REQUIRED, ALL HIGH STRENGTH BOLTS <br />SHALL BE INSTALLED AS FULL PRETENSIONED BOLTS. <br />AT A MINIMUM ALL BOLTED MOMENT AND AXIAL CONNECTION SHALL HAVE <br />PRETENSIONED BOLTS IN STANDARD HOLES. <br />BOLTED MOMENT CONNECTIONS AT CANTILEVERS AND BACKSPANS SHALL USE SLIP <br />CRITICAL BOLTS. <br />DO NOT USE OVERSIZED OR SLOTTED HOLES FOR ANY CONNECTIONS UNLESS <br />SPECIFICALLY INDICATED ON THE DRAWINGS OR APPROVED IN WRITING BY THE SER. <br />SC-9)ALL WELDING SHALL CONFORM TO THE REQUIREMENTS OF THE STRUCTURAL <br />WELDING CODE, ANSI/AWS D1.1, LATEST EDITION. ALL WELD SIZES SHALL BE THE <br />LARGER OF THE SIZE REQUIRED BY CONNECTION FORCES, THE MINIMUM SIZE PER <br />ANSI/AWS D1.1, OR 3/16 INCH MINIMUM FILLET WELD UON. ANY WELD SIZES SHOWN ON <br />THE DESIGN DRAWINGS ARE CONSIDERED EFFECTIVE WELD SIZES AND SHALL BE <br />INCREASED IN ACCORDANCE WITH AWS AS REQUIRED BY GAPS OR SKEWS BETWEEN <br />COMPONENTS. <br />SC-10)USE RUNOFF TABS AT ALL BEVEL AND COMPLETE JOINT PENETRATION WELDS. <br />REMOVE RUNOFF TABS BY NEAT CUTS AFTER WELD IS COMPLETED. GRIND SMOOTH <br />WHERE REQUIRED BY DETAIL. <br />SC-11)WHERE REQUIRED BY DETAIL REMOVE WELD BACK UP BARS AND GRIND SMOOTH <br />AFTER WELD IS COMPLETED. <br />SD STEEL DECK GENERAL REQUIREMENTS <br />SD-1)THE DESIGN, MANUFACTURE AND ERECTION OF STEEL DECK AND ITS ANCHORAGE <br />SHALL, AT A MINIMUM, BE IN ACCORDANCE WITH "DESIGN MANUAL FOR COMPOSITE <br />DECKS, FORM DECKS AND ROOF DECKS" OF THE STEEL DECK INSTITUTE (SDI), CURRENT <br />EDITION AND "SPECIFICATIONS FOR DESIGN OF LIGHT GAGE COLD FORMED STEEL <br />STRUCTURAL MEMBERS" AS PUBLISHED BY THE AMERICAN IRON AND STEEL INSTITUTE <br />(AISI), CURRENT EDITION. <br />SD-2)CONFIGURE ALL STEEL DECK USING THREE SPAN CONTINUOUS LAYOUTS <br />WHEREVER POSSIBLE. <br />SD-3)CONFIGURE ALL STEEL DECK AS SHOWN ON THE DRAWINGS. <br />SD-4)DESIGN STEEL DECK FOR UNSHORED CONDITIONS. <br />DK STEEL COMPOSITE DECK AND FORM DECK <br />DK-1)COMPOSITE DECK AND FORM DECK SHALL CONFORM TO THE FOLLOWING <br />STANDARDS AND MATERIAL PROPERTIES: <br />ASTM A653-HOT-DIPPED GALVANIZED CONFORMING TO ASTM A924 G60, <br />OR <br />ASTM A1008, GRADE C WITH PHOSPHATE TREATED AND BAKED ON RUST-INHIBITIVE <br />PAINT <br />FABRICATE STEEL DECK UNITS AND ACCESSORIES FROM STEEL SHEET CONFORMING <br />TO ASTM A653 STRUCTURAL QUALITY [GRADE 33], WITH A MINIMUM YIELD STRENGTH OF <br />[33 KSI]. <br />DK-2)FASTEN COMPOSITE FLOOR DECK UNITS AS FOLLOWS: <br />A. TO THE STEEL FRAMEWORK AT ENDS OF UNITS AND AT ALL INTERMEDIATE <br />SUPPORTS: BY PUDDLE WELDS NOT LESS THAN 3/4 INCH DIAMETER SPACED AT 12 <br />INCHES ON CENTER MAXIMUM, UON. WHERE PRESENT, A HEADED STUD CAN <br />REPLACE A PUDDLE WELD. <br />B. AT SIDE LAPS OF ADJACENT UNITS BETWEEN SUPPORTS AT INTERVALS NOT <br />EXCEEDING 24 INCHES ON CENTER UON. <br />DK-3)COMPOSITE FLOOR DECK HANGER TABS LOADS SHALL NOT EXCEED [60]LBS PER <br />HANGER TAB. IN ADDITION LOADS ON HANGERS SHALL BE DISTRIBUTED IN SUCH A <br />MANNER THAT THE TRIBUTARY LOADS FOR EACH HANGER SHALL NOT EXCEED 5 <br />POUNDS PER SQUARE FOOT. <br />DK-4)DISTRIBUTE STEEL STUDS UNIFORMLY OVER BEAM SPAN UNLESS OTHERWISE <br />NOTED ON DRAWINGS. MAXIMUM SPACING OF 3/4 INCH HEADED STUDS SHALL NOT <br />EXCEED 12” ON CENTER (ONE STUD PER FOOT) UNLESS OTHERWISE NOTED ON PLAN. <br />DK-5)HEADED SHEAR STUDS SHALL EXTEND A MINIMUM OF 1 ½ INCHES ABOVE THE TOP <br />OF STEEL DECK WITH A MINIMUM CLEAR COVER OF ½ INCH FROM THE TOP OF SLAB. <br />DK-6)STEEL COMPOSITE DECKS ARE TO BE [POURED-TO-THICKNESS] [POURED LEVEL <br />TO COLUMNS] OR AS INDICATED ON THE DRAWINGS. <br />DK-7)DESIGN AND DETAIL COMPOSITE DECK TO SUPPORT SCHEDULED DESIGN LOADS, <br />WORKING AS A PART OF COMPOSITE SLAB. <br />DK-8)DESIGN AND DETAIL STEEL COMPOSITE DECK, FORM DECK, DECK ENCLOSURES, <br />AND DECK ACCESSORIES FOR CONSTRUCTION LOADS. IN DETERMINING <br />CONSTRUCTION LOADING OF FRESH CONCRETE, ACCOUNT FOR RELEVANT FACTORS, <br />INCLUDING BUT NOT LIMITED TO THE FOLLOWING: <br />A. THE PLANNED CONCRETE PLACEMENT METHODS <br />B. ADDITIONAL [5 PSF] CONCRETE WEIGHT DUE TO DECK DEFLECTION <br />C. WHERE DECKS ARE POURED TO LEVEL ADDITIONAL CONCRETE WEIGHT DUE TO <br />CUMULATIVE DEFLECTION OF INDIVIDUAL BEAMS AND GIRDERS EQUAL TO <br />DIAGONAL BAY DIMENSION BETWEEN COLUMNS DIVIDED BY [360] LESS ANY <br />INDICATED CAMBER.] <br />DK-9)THE FIRST SHEET OF STEEL DECK ADJACENT TO AND PARALLEL TO CHORDS, <br />COLLECTORS, BRACED FRAMES, AND MOMENT FRAMES SHALL BE A FULL WIDTH SHEET. <br />RD STEEL ROOF DECK <br />RD-1)STEEL ROOF DECK SHALL CONFORM TO THE FOLLOWING STANDARDS AND <br />MATERIAL PROPERTIES: <br />STEEL FOR DECK ASTM A653, MINIMUM YIELD STRENGTH OF 33 KSI <br />HOT-DIP GALVANIZING ASTM A653 G60 <br />ROOF DECK SHALL BE HOT-DIP GALVANIZED, UON <br />RD-2)PROVIDE STEEL ROOF DECK WITH DEPTH AND MINIMUM GAGE INDICATED ON <br />DRAWINGS. PROVIDE ANCHORAGE TO SUPPORTING MEMBERS AS INDICATED ON <br />DRAWINGS. <br />RD-3)DESIGN AND DETAIL ROOF DECK AND ITS ANCHORAGE TO SUPPORTING MEMBERS <br />TO SUPPORT SCHEDULED DESIGN LOADS, INDICATED DIAPHRAGM SHEAR, AND <br />INDICATED ROOF UPLIFT. ASSUME ROOF DIAPHRAGM LOADS AND ROOF UPLIFT LOADS <br />TO BE APPLIED SIMULTANEOUSLY. <br />RD-4)STEEL ROOF DECK AND ITS ANCHORAGE TO STRUCTURAL FRAMING SHALL BE <br />CAPABLE OF WITHSTANDING THE FOLLOWING MINIMUM LOADING REQUIREMENTS: <br />A. GRAVITY LOAD 30 PSF <br />B. DIAPHRAGM SHEAR DESIGN FORCE 400 PLF <br />C. NET UPLIFT FORCE 10 PSF <br />ASSUME ROOF DIAPHRAGM LOADS AND ROOF UPLIFT LOADS TO BE APPLIED <br />SIMULTANEOUSLY. <br />RD-5)ROOF DECK AND ITS ANCHORAGE TO SUPPORTING MEMBERS SHALL MEET THE <br />FOLLOWING MINIMUM FASTENING REQUIREMENTS <br />A. AT ENDS OF UNITS AND AT ALL INTERMEDIATE SUPPORTS: BY PUDDLE WELDS NOT <br />LESS THAN [5/8]INCH DIAMETER SPACED NOT MORE THAN [12]INCHES ON CENTER <br />MAX. <br />B. SIDE LAPS OF ADJACENT UNITS: SHALL BE FASTENED BY SIDE SEAM WELDING OR <br />SIDELAP SCREWS SPACED PER MANUFACTURERS ENGINEERED CALCULATIONS WITH <br />A MAXIMUM SPACING OF 24 INCHES ON CENTER. ARC SEAM WELDS SHALL BE A <br />MINIMUM OF 1-1/2 INCH BY 1/2 INCH. <br />RD-6)NO LOADS SHALL BE HUNG DIRECTLY FROM STEEL ROOF DECK WITHOUT PRIOR <br />WRITTEN APPROVAL OF THE DECK SUPPLIER AND REVIEW BY THE SER. <br />RD-7)DECKING CONTRACTOR SHALL COORDINATE DECK OPENING SIZES AND <br />LOCATIONS FROM ARCHITECTURAL AND MEP CONTRACT DOCUMENTS, PROVIDE <br />HEADER MEMBERS OR REINFORCEMENT AS REQUIRED BY TYPICAL DETAILS EVEN IF <br />NOT SHOWN ON THE PLANS, AND SUBMIT PROPOSED OPENINGS THROUGH SLAB/DECK <br />FOR REVIEW BY THE DESIGN PROFESSIONALS. <br />SY SURVEYS <br />SY-1)SURVEY OF FLAT PLATE OR FLAT SLAB CONCRETE FLOORS CONSTRUCTION: SEE <br />DETAILS NOTES AND DRAWINGS. <br />SY-2)SURVEY OF VERTICAL OF HIGH RISE CONSTRUCTION. <br />SY-3)SURVEY OF LONG SPAN CONSTRUCTION. <br />SF SURVEY OF FLAT PLATE CONCRETE FLOORS <br />SF-1)SURVEY OF FLAT PLATE OR FLAT SLAB CONCRETE FLOORS DURING <br />CONSTRUCTION, FOR BUILDINGS WITH FOUR FLOORS OR MORE: <br />A. SUBMIT A SURVEYING PLAN FOR INFORMATION 30 DAYS PRIOR TO THE START OF THE <br />FIRST FLAT PLATE/SLAB FLOOR CONSTRUCTION. <br />B. SUBMIT ELEVATION SURVEYS FOR RECORD AT FLOORS B4 THROUGH 34 IMMEDIATELY <br />UPON COMPLETION OF SURVEYS AT THE FOLLOWING STAGES. ALL SURVEYS ARE TO <br />THE BOTTOM OF THE SLAB: <br />1. PRIOR TO THE PLACEMENT OF CONCRETE <br />2. WITHIN ONE DAY OF PLACEMENT <br />3. AT STRIPPING OF SHORING, PRIOR TO INSTALLATION OF RESHORING <br />4. IMMEDIATELY AFTER ALL RESHORING HAS BEEN REMOVED FROM ABOVE AND BELOW <br />THE SLAB <br />C. PROVIDE ELEVATION SURVEYS AT ADDITIONAL FLOORS BASED ON THE DESIGN <br />TEAM’S EVALUATION OF THE INITIAL SURVEY RESULTS. <br />D. FOR EACH SURVEY PROVIDE MEASUREMENTS AT THE FOLLOWING POINTS: <br />1. EACH COLUMN <br />2. EACH WALL AT INTERSECTION WITH COLUMN LINES <br />3. EACH POINT DESIGNATED BY DRAWINGS WITH A CAMBER <br />4. ALONG THE PERIMETER, MIDSPAN OF EACH BAY <br />5. ALONG THE GRID LINES, MIDSPAN OF EACH BAY <br />6. CENTER OF EACH BAY <br />E. BASED ON THE REVIEW OF SURVEY RESULTS, THE STRUCTURAL ENGINEER MAY <br />MODIFY DESIGN CAMBER VALUES AND/OR COMMENT ON CONSTRUCTION METHODS <br />(RESHORING, SEQUENCING, ETC.) <br />SP STRUCTURAL PRECAST CONCRETE <br />SP-1)TYPICAL DETAILS INDICATE GENERAL CRITERIA FOR DESIGN AND DETAILING <br />OF PRECAST CONCRETE. PROVIDE DESIGNS THAT MEET INDICATED CRITERIA AND <br />LISTED CODES AND STANDARDS. <br />SP-2)PROVIDE CONNECTIONS BETWEEN ADJACENT PRECAST UNITS TO TRANSMIT <br />[xxx]POUNDS PER LINEAR FOOT OF DIAPHRAGM LOADS. <br />SP-3)PROVIDE CAMBER TO LIMIT DEFLECTION SUCH THAT NO POINT OF THE <br />DEFLECTED STRUCTURE EXCEEDS [XX]”BELOW THE STATED ELEVATION. <br />CAMBER DESIGN SHALL INCLUDE EFFECTS OF LONG-TERM DEFLECTION, <br />SHRINKAGE, CREEP, AND MAXIMUM ALLOWABLE CONSTRUCTION TOLERANCES. <br />SP-4)DO NOT USE POWER-DRIVEN ANCHORS OR ANCHORS WHICH REQUIRE <br />DRILLING INTO PRESTRESSED UNITS. SUBMIT PROPOSED ANCHOR PROCEDURES <br />FOR PRECAST UNITS TO THE DESIGN PROFESSIONALS AND PRECAST SUPPLIER <br />FOR REVIEW. <br />PT POST-TENSIONED CONCRETE <br />PT-1)POST-TENSIONING STRAND: ASTM A416, GRADE 270, LOW RELAXATION TYPE, <br />1/2-INCH DIAMETER, 7-WIRE STRAND, UNBONDED, UON. <br />PT-2)TENDONS SHALL BE PLASTIC SHEATHED, GREASED, AND RUST PROTECTED. <br />PROVIDE COMPLETE WATERTIGHT ENCAPSULATION SYSTEM FOR PRESTRESSING <br />STEEL, ANCHORAGES, AND COUPLINGS. <br />PT-3)POST-TENSIONING FORCES INDICATED ON THE STRUCTURAL DRAWINGS ARE <br />THE REQUIRED FINAL EFFECTIVE FORCES AFTER ALL IMMEDIATE AND LONG-TERM <br />LOSSES. <br />PT-4)PROPER TENDON LOCATION SHALL HAVE PRIORITY OVER ALL OTHER <br />MATERIALS AND TRADES. RELOCATING TENDONS CAN ONLY BE DONE WITH PRIOR <br />WRITTEN APPROVAL FROM THE SER. <br />PT-5)THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE SER WHERE TENDONS <br />FOR DIFFERENT POST-TENSIONED MEMBERS INTERFERE WITH ONE ANOTHER. <br />RELOCATING TENDONS CAN ONLY BE DONE WITH PRIOR WRITTEN APPROVAL <br />FROM THE SER. <br />PT-6)THE STRESSING OF TENDONS SHALL BE PERMITTED ONLY AFTER THE <br />CONCRETE HAS ATTAINED AT LEAST 75 PERCENT OF THE SPECIFIED COMPRESSIVE <br />STRENGTH / A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI.(MINIMUM 4000PSI <br />COMPRESSIVE STRENGTH REQUIRED AT LEVEL 06+) <br />PT-7)POST-INSTALLED ANCHORS SHALL NOT PENETRATE MORE THAN 3/4- INCH <br />INTO POST-TENSIONED MEMBER UNLESS SPECIAL PRECAUTIONS ARE USED TO <br />INDICATE LOCATIONS OF ALL TENDONS. POST-INSTALLED ANCHORS INTO POST- <br />TENSIONED MEMBERS SHALL NOT BE PERMITTED WITHOUT PRIOR WRITTEN <br />APPROVAL FROM THE SER. <br />PT-8)CORING OF POST-TENSIONED MEMBERS SHALL NOT BE PERMITTED WITHOUT <br />WRITTEN APPROVAL FROM THE SER. <br />PT-9)THE CONTRACTOR SHALL COORDINATE THE LOCATION OF EMBEDDED ITEMS <br />WITH POST-TENSIONING MATERIAL SUPPLIER AND RESOLVE ANY CONFLICTS PRIOR <br />TO INSTALLATION. <br />T: F: <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />301 N. Broadway, Santa Ana, CA <br />707 Wilshire Blvd, Suite 4450 <br />Los Angeles, CA 90017-3618 <br />Thornton Tomasetti, Inc. <br />213.330.7700 213.330.7001 <br />3RD & BROADWAY - <br />RESIDENTIAL <br />12" = 1'-0" <br />11/19/2024 3:19:58 PM <br />R1.S0.03 <br />GENERAL NOTES <br />S21043.00 <br />A 06.10.2022 REISSUE FOR PLAN CHECK <br />B 06.17.2024 REVISION TO PERMIT <br />1/7/25