My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
301 N Broadway - Shell & Core - Plan (2)
PBA
>
Building
>
ProjectDox
>
B
>
Broadway
>
301 N Broadway
>
301 N Broadway - Shell & Core - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2026 5:01:29 AM
Creation date
3/10/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
20183592
30147601
40139376
101120309
Full Address
301 N Broadway
Street Number
301
Street Direction
N
Street Name
Broadway
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2081
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
R08R09R10R11R12R13R14R15R16R17 <br />RF <br />RG <br />RH <br />RJ <br />RK <br />RL <br />R07 <br />12 <br />R11' <br />7 7 <br />13 <br />SUPERPOSED DEAD AND LIVE LOAD SCHEDULE <br />DESCRIPTIONDESIGNATION <br />MARK CEILING TYPE <br />5 <br />4 <br />3 <br />7 <br />1 RESIDENTIAL UNITS <br />LOBBIES/CORRIDORS, <br />AND STAIRS <br />MECHANICAL / ELECTRICAL <br />PARKING (GARAGES) <br />RAMPS <br />TOTAL SDL <br />32 <br />12 <br />5 <br />5 <br />5 <br />2 <br />UNFACTORED SUPERIMPOSED DEAD LOAD <br />(PSF UNO) <br />FLOOR FINISHES TOTAL LLPARTITION <br />20 <br />0 <br />40 <br />40* <br />0 <br />0 <br />0 <br />100 <br />125* <br />40* <br />ROOF <br />STORAGE <br />OUTDOOR AMENTITIES <br />8 <br />12 <br />11 <br />10 <br />62.5 <br />20 <br />17.5 <br />0 <br />0 <br />0 <br />100 <br />125* <br />20 <br />105 75 (SLOPE TO DRAIN) <br />25 (PAVER)0 100* <br />GROUND LEVEL <br />RETAIL & LOBBIES <br />6 42.5 0 100*BALL ROOM / INDOOR AMENITY <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />ASSEMBLY AREA <br />7 <br />37.5 <br />37.5 <br />0 <br />0 <br />0 <br />7 <br />12.5 <br />15 <br />2 RESIDENTIAL BALCONIES <br />(STACKED)10 2 0 605 <br />RESIDENTIAL <br />9 530 0 40WATER TANK 2 <br />ROOF MECHANICAL13 20 0 125*2 15 <br />POOL14 410 0 100*2 <br />STAFF / OFFICE15 20 5027 <br />KITCHEN / DINNING16 0 150*2 7 <br />32 <br />12 <br />25 (FINISHES) <br />500 (WATER) <br />250 (4'-0" WATER) <br />150 (SUBFRAMING)ASSEMBLY AREA <br />LIGHTING / MEP <br />UNFACTORED LIVE LOAD <br />(PSF UNO) <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />8 <br />3 <br />3 <br />BALCONIES <br />LIGHT STORAGE <br />GARAGES <br />GARAGES <br />PUBLIC ROOMS <br />CORRIDORS <br />FIRST FLOOR RETAIL <br />LIGHT STORAGE <br />ROOF <br />OFFICES <br />DININGS <br />17 ROADWAY/LANDSCAPE 0 250*5 2752800 ROADWAY <br />SEE NOTE 7 <br />5A ACCESS RAMP 60 0 100255 <br />(5" MAX LWT TOPPING)3 ACCES RAMP <br />LOADING PLAN NOTES: <br />1. SUPERIMPOSED DEAD LOADS ARE IN ADDITION TO THE SELF-WEIGHT OF THE STRUCTURE. <br />2. SEE FRAMING PLANS FOR DESIGN LOAD OF SPECIFIC ITEMS SUCH AS ELEVATORS, ESCALATORS, AND MECHANICAL / ELECTRICAL EQUIPMENT. <br />3. HAND AND GUARDRAIL ASSEMBLY LIVE LOAD IS THE GREATER OF 200LB AND 50LB/FT IN ANY DIRRECTIONS. <br />4. * DENOTES NON-REDUCIBLE LIVE LOADS, TYPE 4 AND 5 (PARKING AND RAMP) ARE 20% REDUCIBLE FOR COLLUMN AND FOUNDATIONS. <br />5. SEE R1.S0.40 , R1.S0.41 & R1.S0.42 FOR COMPONENTS AND CLADDING LOADS. <br />6. SEE R1.S0.20 FOR FINISH FLOOR TYPE SCHEDULE. <br />7. MAXIMUM DESIGNED AXLE LOAD PER AASHTO FOR A DESIGN TANDEM (PAIR OF 25-KIP AXLES SPACED 4'-0" APART, WITH 8-KIP LOAD AT CAB) <br />18 <br />19 <br />20 <br />GREEN ROOF <br />PLANTER (3'-0") <br />PLANTER (4'-0") <br />0 2021053 ROOF <br />0 202385 3 PLANTER <br />0 202 <br />495 <br />+ 2,000LBS TREE <br />3 PLANTER <br />50 (TOPPING) <br />50 (GREEN ROOF SYSTEM) <br />330 (3'-0" MAX SOIL) <br />25 (PAVER) <br />25 (PLANTER) <br />440 (4'-0" MAX SOIL) <br />25 (PAVER) <br />25 (PLANTER) <br />21 <br />22 <br />15A <br />MEDIUM TREE PLANTER <br />HEAVY TREE PLANTER <br />BUILT-UP SLAB OFFICE <br />0 202 <br />495 <br />+ 6,000LBS TREE <br />3 PLANTER <br />440 (4'-0" MAX SOIL) <br />25 (PAVER) <br />25 (PLANTER) <br />440 (4'-0" MAX SOIL) <br />25 (PAVER) <br />25 (PLANTER) <br />272 3 <br />495 <br />2 3 0 20 PLANTER <br />20 507 <br />40 (4" LWT TOPPING)OFFICES <br />12 723 0 100*PUBLIC ROOMSFITNESS CENTER / GYM23 <br />R08R09R10R11R12R13R14R15R16R17 <br />RF <br />RG <br />RH <br />RJ <br />RK <br />RL <br />R07R11' <br />12 12 <br />T: F: <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />301 N. Broadway, Santa Ana, CA <br />707 Wilshire Blvd, Suite 4450 <br />Los Angeles, CA 90017-3618 <br />Thornton Tomasetti, Inc. <br />213.330.7700 213.330.7001 <br />3RD & BROADWAY - <br />RESIDENTIAL <br />As indicated <br />11/19/2024 3:21:04 PM <br />R1.S0.14 <br />LOADING PLANS <br />S21043.00 <br />SCALE: 1" = 20'-0"1 LEVEL ROOF - LOADING PLAN <br />SCALE: 1" = 20'-0"2 TOP OF CORE - LOADING PLAN <br />1 12.10.2021 REISSUE FOR PLAN CHECK <br />A 06.10.2022 REISSUE FOR PLAN CHECK <br />B 06.17.2024 REVISION TO PERMIT <br />C 09.27.2024 REISSUE FOR PLAN CHECK <br />C <br />C <br />1/7/25
The URL can be used to link to this page
Your browser does not support the video tag.